Mark Rayner – Analysis SessionCM25, 4 November 20091 Beam characterization by the TOFs Mark Rayner The University of Oxford MICE CM25.

Slides:



Advertisements
Similar presentations
Progress in the construction of the MICE cooling channel and first measurements Adam Dobbs, EPS-HEP, 23 rd July 2011.
Advertisements

1 Simulation Status/Plans Malcolm Ellis Sci Fi Tracker Meeting Imperial College, 10 th September 2004.
1 Progress report on Calorimeter design comparison simulations MICE detector phone conference Rikard Sandström.
Emittance definition and MICE staging U. Bravar Univ. of Oxford 1 Apr Topics: a) Figure of merit for MICE b) Performance of MICE stages.
FIGURE OF MERIT FOR MUON IONIZATION COOLING Ulisse Bravar University of Oxford 28 July 2004.
1 Angular Momentum from diffuser Beam picks up kinetic angular momentum (L kin ) when it sits in a field –Canonical angular momentum (L can ) is conserved.
FODO-based Quadrupole Cooling Channel M. Berz, D. Errede, C. Johnstone, K. Makino, Dave Neuffer, Andy Van Ginneken.
Particle by Particle Emittance Measurement to High Precision Chris Rogers Imperial College/RAL 17th March 2005.
1 Emittance Calculation Progress and Plans Chris Rogers MICE CM 24 September 2005.
1 PID, emittance and cooling measurement Rikard Sandström University of Geneva MICE Analysis phone conference.
Emittance–momentum matrix1 Demonstrating the emittance-momentum matrix Mark Rayner, MICE Video Conference, 21 January Initial 4D.
SLIDE Beam measurements using the MICE TOF counters Analysis meeting, 23 September 2008 Mark Rayner.
1 Downstream PID update Rikard Sandström PID phone conference
1 September 09Mark Rayner – Emittance measurement by The TOFs1 Emittance measurement by the TOFs Via trace space reconstruction of individual muons. Complementary.
Analysis Meeting – – Slide 1 Beam momentum measurement using TOFs: progress report Analysis Meeting, February 2008 Mark Rayner.
1 Downstream scraping and detector sizes Rikard Sandström University of Geneva MICE collaboration meeting CERN.
1 PID Detectors & Emittance Resolution Chris Rogers Rutherford Appleton Laboratory MICE CM17.
1 PID status MICE Analysis phone conference Rikard Sandström.
M.apollonioCM17 -CERN- (22/2 - 25/2 2007)1 Single Particle Amplitude M. Apollonio – University of Oxford.
Chris Rogers, MICE CM16 Wednesday Plenary Progress in Cooling Channel Simulation.
Beam line characterization with the TOFs1 Demonstrating the emittance-momentum matrix Mark Rayner, CM26 California, 24 March Initial.
Diffuser in G4MICE Victoria Blackmore 09/03/10 Analysis Meeting 1/8.
1 OPTICS OF STAGE III Ulisse Bravar University of Oxford 6 October 2004.
1 Losses in the Cooling Channel Malcolm Ellis PID Meeting 1 st March 2005.
Simulated real beam into simulated MICE1 Mark Rayner CM26.
Analysis Meeting 27 Jan 09Beam Characterization with TOFs1 Beam Characterization with the TOFs Mark Rayner.
5 May 2009MICE Analysis - MR1 The December Shifts: Beam Characterization by the Time of Flight System Mark Rayner.
TOF Resolution Required to measure bunch length ~ 0.5 ns RMS from RF Bucket size For 1e-3 emittance measurement resolution of TOF should be
CM23 Harbin January 2009TOF Emittance Measurement1 Beam Characterization with the TOFs Mark Rayner CM23 Harbin.
Mark Rayner, Analysis workshop 4 September ‘08: Use of TOFs for Beam measurement & RF phasing, slide 1 Use of TOFs for Beam measurement & RF phasing Analysis.
18 August 09Mark Rayner – Momentum measurement by The TOFs1 Momentum measurement by the TOFs A correction to an O(4 MeV/c) bias on the current muon momentum.
Chris Rogers, Analysis Parallel, MICE CM17 Progress in Cooling Channel Simulation.
M.apollonio/j.cobbMICE UK meeting- RAL - (9/1/2007) 1 Single Particle Amplitude M. Apollonio – University of Oxford.
Diffuser Studies Chris Rogers, IC/RAL MICE VC 09 March 2005.
Analysis of MICE Chris Rogers 1 Imperial College/RAL Thursday 28 October, With thanks to John Cobb.
1 M. Bonesini - CM 25 RAL 5/11/09 PID status report M. Bonesini Sezione INFN Milano Bicocca.
Emittance measurement: ID muons with time-of-flight Measure x,y and t at TOF0, TOF1 Use momentum-dependent transfer matrices iteratively to determine trace.
Emittance measurement: ID muons with time-of-flight Measure x,y and t at TOF0, TOF1 Use momentum-dependent transfer matrices to map  path Assume straight.
MICE pencil beam raster scan simulation study Andreas Jansson.
Influence of the Third Harmonic Module on the Beam Size Maria Kuhn University of Hamburg Bachelor Thesis Presentation.
Feb 10, 2005 S. Kahn -- Pid Detectors in G4MicePage 1 Pid Detector Implementation in G4Mice Steve Kahn Brookhaven National Lab 10 Feb 2005.
Results from Step I of MICE D Adey 2013 International Workshop on Neutrino Factories, Super-beams and Beta- beams Working Group 3 – Accelerator Topics.
MICE Step 1: First Emittance Results with Particle Physics Detectors Linda R. Coney EuCARD Meeting – 10 May 2011.
1 Calorimeter in G4MICE Berkeley 10 Feb 2005 Rikard Sandström Geneva University.
Mark Rayner 14/8/08Analysis Meeting: Emittance measurement using the TOFs 1 Emittance measurement using the TOFs The question: can we use position measurements.
11 Nov 2008PC Analysis PC Schedule 2008 Tuesdays fortnightly 9 September  23 September  2 October  CM22  11 November  25 November 9 December.
Marco apollonio/J.CobbMICE coll. meeting 16- RAL - (10/10/2006) 1 Transmittance, scraping and maximum radii for MICE STEPVI M. Apollonio – University of.
M. Ellis - MICE Collaboration Meeting - Thursday 28th October Sci-Fi Tracker Performance Software Status –RF background simulation –Beam simulation.
PID simulations Rikard Sandström University of Geneva MICE collaboration meeting RAL.
3 June 2009J. H. Cobb 1 ANALYSIS SUMMARY CM24 Agenda for Analysis parallel session at CM Sunday 31 May 14:00.
PID Detector Requirements for Emittance Measurement Chris Rogers, MICE PID Review, Thursday Oct 12.
Timing measurements at the MICE experiment – 1 The analysis of timing measurements at the Muon Ionization Cooling Experiment Mark Rayner The University.
MCS: Multiple Coulomb Scattering Sophie Middleton.
26 Oct 2010PC Physics Requirements of Software from Chris R ~19 Oct. My.
Analysis meeting: Beam momentum measurements using TOFs Tuesday, 22 January 2008 Slide 1 of 10 Beam momentum measurement using.
18 th March 2008Measuring momentum using the TOFsSlide 1 Measuring momentum using TOF0 and TOF1 Progress report Mark Rayner (Oxford/RAL) Analysis Meeting,
TOF Emittance Pion Emittance Measurement with the TOFs? Mark Rayner 11 December 2008.
Mark Rayner 26/8/08Analysis Meeting: Emittance measurement using the TOFs 1 Measuring emittance with the TOFs Data: –G4MICE has been used to obtain transfer.
M. apollonio 7/7/2010CM27 - RAL11 Beam-Line Analysis …
M. Ellis - MICE Collaboration Meeting - Wednesday 27th October Sci-Fi Tracker Performance Software Status –RF background simulation –Beam simulation.
Monte Carlo simulation of the particle identification (PID) system of the Muon Ionization Cooling Experiment (MICE) Mice is mainly an accelerator physics.
Mark Rayner – Analysis SessionCM25, 4 November The TOF detectors: Beyond particle identification Mark Rayner The University of Oxford MICE CM25.
TOF Emittance Emittance measurements with the TOFs Mark Rayner 4 December 2008.
Brunel University London Field-off LiH Energy Loss Rhys Gardener CM45 – July 28th.
Step IV Physics Paper Readiness
MICE Step IV Lattice Design Based on Genetic Algorithm Optimizations
Field-on measurement of multiple scattering
Step 1 Analysis: Progress Towards the Emittance Paper
TOF Software and Analysis Tools
MICE: First Beam Emittance Results w/Particle Detectors
Presentation transcript:

Mark Rayner – Analysis SessionCM25, 4 November Beam characterization by the TOFs Mark Rayner The University of Oxford MICE CM25

Mark Rayner – Analysis SessionCM25, 4 November Compressed schematic view of the upstream beam line TRP Q7Q8Q9Diffuser x, y, z p x, p y, p z I7I7 I8I8 I9I9 IDID D2 RFAbsorber t 1 x 1, y 1 t 0 x 0, y 0 t ? t ? ? Stages II - VI  x,  y , , , 

Mark Rayner – Analysis SessionCM25, 4 November Beam characterization using the TOFs PID at the diffuser emittance phase ellipse orientation beam size at TOF1 emittance phase ellipse orientation longitudinal momentum path length trans mom z g0g0

Mark Rayner – Analysis SessionCM25, 4 November Momentum measurement by the TOFs ‏Muon energy approximately constant between TOFs  p/E = s/t  s = path length between TOF0 and TOF1 (~8m)  t = time of flight (~29ns at 250 MeV/c) ‏Predicted resolution  4.7 MeV/c at 250 MeV/c ‏Bias on the measurement  Time of flight mis-calibration by 10 ps: 0.57 MeV/c bias  Path length over/underestimation by 10 mm: 2.1 MeV/c bias

Mark Rayner – Analysis SessionCM25, 4 November Digression: positron TOF0 – TOF1 calibration ‏Positrons all travel at c  Used to calibrate TOF0 relative to TOF1:  t=  z/c  However their path exceeds the longitudinal displacement and cannot be individually determined ‏Need a careful Monte Carlo  Input positron calibration beam from G4BL simulation – not yet simulated ‏Instead get a rough idea – uniformly populate phase space  For a paraxial beam in a quadrupole channel, contributions to (s-L) from x and y may be separated… x y pxpx pypy

Mark Rayner – Analysis SessionCM25, 4 November Path length – L as a function of transverse phase space x (mm) y (mm) s - L (mm) p y (MeV/c) p x (MeV/c) y = p y = 0 x = p x = 0

Mark Rayner – Analysis SessionCM25, 4 November Conclusion to the digression ‏Positron path lengths can exceed L by 70mm  (230ps bias on time of flight)  Any more and they are scraped  However the majority of transmitted phase space has (s-L) ~ O(10mm)  [30ps bias] ‏A Monte Carlo simulation is required  Which part of phase space is occupied by the positron beam?

Mark Rayner – Analysis SessionCM25, 4 November Beam characterization using the TOFs PID at the diffuser emittance phase ellipse orientation beam size at TOF1 emittance phase ellipse orientation longitudinal momentum path length trans mom z g0g0

Mark Rayner – Analysis SessionCM25, 4 November Monte Carlo simulation ‏Marco’s  =6mm p absorber =200 MeV/c centre of the e-p matrix beam  Mean Pz = 270 MeV/c at TOF0 (see left histogram) ‏P/E=s/t where s=true path length  Measures true p before TOF1 with RMS error 0.65 MeV/c  See right histogram  Width and bias due to dE/dx in the air between TOF0 and TOF1

Mark Rayner – Analysis SessionCM25, 4 November Should we simply approximate s=  z? ‏P/E=  z/t  RMS error 3.38 MeV/c  Bias MeV/c  Due to the width of the  =s-  z distribution

Mark Rayner – Analysis SessionCM25, 4 November Monte Carlo: Full demonstration of P reconstruction ‏Iterative calculation of increasingly good s=  z+  and P  Begin with P from P/E=  z/t 1 Calculate a linear transfer map at P from TOF0 to TOF1 (top hat quadrupoles) 2 Deduce x 0 ’ and y 0 ’ from x 1 and y 1 3 Integrate ds while tracking the initial trace space vector through the beam line 4 Make a better estimate of P from P/E=s/t 5 Make a small Bethe-Bloch correction for the energy loss in air between the TOFs

Mark Rayner – Analysis SessionCM25, 4 November Result of the full Monte Carlo

Mark Rayner – Analysis SessionCM25, 4 November Momentum measurement conclusion ‏This method eliminates path length bias ‏It is implemented as a G4MICE application  It should replace the current p/E=  z/t automatic momentum reconstruction  Emittance measurement is a natural by-product at minimal extra cost  An online monitoring GUI can be produced to plot p and  in real time ‏It initially requires  Quadrupole currents I 7, I 8 and I 9  Quadrupole and TOF positions z 0, z 7, z 8, z 9, z 1  Eventually easily obtained from from the database ‏For individual muon P measurements it requires  t, x 0, y 0, x 1, y 1, PID ‏This method will not work with positrons  Therefore TOF calibration must use simulation of positron beam

Mark Rayner – Analysis SessionCM25, 4 November TOF0 x mm: x’ radians Truth Reconstruction All Monte Carlos from a realistic G4BeamLine 6mm emittance 200 MeV/c centre of absorber momentum beam simulated in G4MICE Note that this method has also reconstructed x0’ and y0’ We can just as easily deduce (x1’, y1’) from (x0, y0)

Mark Rayner – Analysis SessionCM25, 4 November TOF1 x mm: x’ radians Truth Reconstruction

Mark Rayner – Analysis SessionCM25, 4 November TOF0 y mm: y’ radians Truth Reconstruction

Mark Rayner – Analysis SessionCM25, 4 November TOF1 y mm: y’ radians Truth Reconstruction

Mark Rayner – Analysis SessionCM25, 4 November Work in progress ‏Software  Currently debugging momentum bias correction/emittance measurement with the new data and new calibration  Online reconstruction featuring these innovations  Add TOF0-TOF1 calibration to overall TOF calibration procedure ‏Physics  Extrapolation of beam size at diffuser – easy!   O T  O  Where O is just a drift transfer matrix ‏Simulation  Require positron simulation with TOF calibration optics ‏Shifts  Measure emittance at the elements of the emittance-momentum matrix  Beam size at the diffuser  Compare measured Twiss parameters with the design optics