PIXEL2010. V. Pugatch.1 Metal and Hybrid TimePix Detectors Imaging Beams of Particles M. Campbell, L. Tlustos, X.Llopart, CERN S. Pospisil, IEAP, Prague.

Slides:



Advertisements
Similar presentations
STATUS OF MEDIPIX-3, PLANS FOR TIMEPIX-2 X. Llopart.
Advertisements

Imaging Properties of the Medipix2 System exploiting Single and Dual Energy Thresholds L. Tlustos 1, R. Ballabriga 1, M. Campbell 1, E. Heijne 1, k Kincade.
METAL FOIL DETECTORS AND THEIR APPLICATIONS ABSTRACT To monitor charge particle fluence distribution, various methods have been developed. We report here.
SOIPD Status e prospective for 2012 The SOImager2 is a monolithic pixel sensor produced by OKI in the 0.20 µm Fully Depleted- Silicon On Insulator (FD-SOI)
Radiation Detectors There are a variety of detectors that can be used to measure particles emitted from nuclear reactions. The various materials used in.
The LHCb Inner Tracker LHCb: is a single-arm forward spectrometer dedicated to B-physics acceptance: (250)mrad: The Outer Tracker: covers the large.
experimental platform
Status and outlook of the Medipix3 TSV project
Chapter 8 – Mass Spectrometry. Mass Spectrometry The mass spectrometer can be used for: – Quantitative analysis – as a sophisticated and very sensitive.
Secondary ion mass spectrometry (SIMS)
ITAM CAS, IEAP CTU IWORID 2004Glasgow, th July IWORID 2004 OPTIMIZATION OF X ‑ RAY DYNAMIC DEFECTOSCOPY USING MEDIPIX-2 FOR HIGH FRAME RATE READ-OUT.
V. Pugatch CBM Collaboration Meeting, Dubna, Oct CBM Silicon Tracking System. Results of the pre-prototype detector module test. V.M. Pugatch.
METAL FOIL DETECTORS FOR THE RADIATION AND BEAM POSITION MONITORING ABSTRACT To monitor charge particle fluences distribution various methods have been.
11 th RD50 Workshop, CERN Nov Results with thin and standard p-type detectors after heavy neutron irradiation G. Casse.
Status of the Beamline Simulation A.Somov Jefferson Lab Collaboration Meeting, May 11, 2010.
Tools for Nuclear & Particle Physics Experimental Background.
Scanning Electron Microscope (SEM)
Radioactive ion beam facilities How does they work ? 2012 Student Practice in JINR Fields of Research 9.oct.2012 I. Sivacekflerovlab.jinr.ru.
1 Tehniline ülevaade uusimast füüsikast CERN’is Endel Lippmaa 20. Detsember 2006, TTÜ.
Mass Spectroscopy 1 Mass Spectroscopy (Mass Spec) Applying Atomic Structure Knowledge to Chemical Analysis.
Fully depleted MAPS: Pegasus and MIMOSA 33 Maciej Kachel, Wojciech Duliński PICSEL group, IPHC Strasbourg 1 For low energy X-ray applications.
Munich-Centre for Advanced Photonics A pixel detector system for laser-accelerated ion detection Sabine Reinhardt Fakultät für Physik, Ludwig-Maximilians-Universität.
Advanced semiconductor detectors of neutrons
ARDENT Advanced Radiation Dosimetry European Network Training initiative WP1: Gas Detectors S. Rollet.
Energy calibration of the threshold of Medipix for ATLAS Céline Lebel Université de Montréal presenting for the Institut of Experimental.
Experimental part: Measurement the energy deposition profile for U ions with energies E=100 MeV/u - 1 GeV/u in iron and copper. Measurement the residual.
Beam Tests of 3D Vertically Interconnected Prototypes Matthew Jones (Purdue University) Grzegorz Deptuch, Scott Holm, Ryan Rivera, Lorenzo Uplegger (FNAL)
Novel Semi-Transparent Optical Position Sensors for high-precision alignment monitoring applications Sandra Horvat, F.Bauer, V.Danielyan, H.Kroha Max-Planck-Institute.
Effects of Surrounding Materials on Proton-Induced Energy Deposition in Large Silicon Diode Arrays Christina L. Howe 1, Robert A. Weller 1, Robert A. Reed.
Haga clic para modificar el estilo de texto del patrón Infrared transparent detectors Manuel Lozano G. Pellegrini, E. Cabruja, D. Bassignana, CNM (CSIC)
1 InGrid: the integration of a grid onto a pixel anode by means of Wafer Post Processing technology 16 April 2008 Victor M. Blanco Carballo.
CBM Silicon Tracking System. Microstrip Detector Module Assembly and Test V.M. Pugatch Kiev Institute for Nuclear Research GSI (CBM experiment), Darmstadt.
Nov Beam Catcher in KOPIO (H. Mikata Kaon mini worksyop1 Beam Catcher in the KOPIO experiment Hideki Morii (Kyoto Univ.) for the KOPIO.
Institute of Experimental and Applied Physics Czech Technical University in Prague IEAP – CTU Prague 1 Current status and future development of neutron.
Review of synthesis of super heavy elements: reactions, decays and characterization. Experimental Setup of MASHA. Results of first experiments. study.
Secondary Ion Mass Spectrometry A look at SIMS and Surface Analysis.
Snowmass, August, 2005P. Colas - InGrid1 M. Chefdeville a, P. Colas b, Y. Giomataris b, H. van der Graaf a, E.H.M.Heijne c, S.van der Putten a, C. Salm.
Basics of Ion Beam Analysis
- Performance Studies & Production of the LHCb Silicon Tracker Stefan Koestner (University Zurich) on behalf of the Silicon Tracker Collaboration IT -
The RICH Detectors of the LHCb Experiment Carmelo D’Ambrosio (CERN) on behalf of the LHCb RICH Collaboration LHCb RICH1 and RICH2 The photon detector:
Lecture 3-Building a Detector (cont’d) George K. Parks Space Sciences Laboratory UC Berkeley, Berkeley, CA.
Charles University Prague Charles University Prague Institute of Particle and Nuclear Physics Absolute charge measurements using laser setup Pavel Bažant,
CBM Collaboration Meeting. GSI, Darmstadt CBM Silicon Tracking System. CBM-01 sensors characterization. V.M. Pugatch Kiev Institute for Nuclear.
Tracking in a TPC D. Karlen / U. Victoria & TRIUMF for the LCTPC collaboration.
-1-CERN (11/24/2010)P. Valerio Noise performances of MAPS and Hybrid Detector technology Pierpaolo Valerio.
Neutron production in Pb/U assembly irradiated by deuterons at 1.6 and 2.52 GeV Ondřej Svoboda Nuclear Physics Institute, Academy of Sciences of Czech.
Questions/Problems on SEM microcharacterization Explain why Field Emission Gun (FEG) SEM is preferred in SEM? How is a contrast generated in an SEM? What.
METAL DETECTORS: PERFORMANCES AND APPLICATIONS Oleksandr Okhrimenko Institute for Nuclear Research NAS of Ukraine, Kiev.
Proportional chambers with cathode readout in high particle flux environment Michał Dziewiecki.
Progress with GaAs Pixel Detectors K.M.Smith University of Glasgow Acknowledgements: RD8 & RD19 (CERN Detector R.&D. collaboration) XIMAGE (Aixtron, I.M.C.,
Mass Spectrometry Relative atomic masses and the mass of individual isotopes can be determined using a mass spectrometer. The principle behind mass spectrometry.
Electron Spectrometer: Status July 14 Simon Jolly, Lawrence Deacon 1 st July 2014.
Metal micro-detector TimePix imaging synchrotron radiation beams at the ESRF Bio-Medical Beamline ID17 Andrii Chaus Institute for Nuclear Research National.
P.F.Ermolov SVD-2 status and experimental program VHMP 16 April 2005 SVD-2 status and experimental program 1.SVD history 2.SVD-2 setup 3.Experiment characteristics.
Development of a Single Ion Detector for Radiation Track Structure Studies F. Vasi, M. Casiraghi, R. Schulte, V. Bashkirov.
Hiden Compact SIMS Mass Spectrometry in solid material.
MICRO-STRIP METAL DETECTOR FOR BEAM DIAGNOSTICS PRINCIPLE OF OPERATION Passing through metal strips a beam of charged particles or synchrotron radiation.
February 10, 2009, G-APD Workshop, GSI Darmstadt1 APD Laser Test Setup Charles University, Faculty of Mathematics and Physics, Institute of Particle and.
V.Aulchenko 1,2, L.Shekhtman 1,2, B.Tolochko 3,2, V.Zhulanov 1,2 Budker Institute of Nuclear Physics, , Novosibirsk, Russia Novosibirsk State University,
0 Characterization studies of the detector modules for the CBM Silicon Tracking System J.Heuser 1, V.Kyva 2, H.Malygina 2,3, I.Panasenko 2 V.Pugatch 2,
DEVELOPMENT OF PIXELLATED SEMICONDUCTOR DETECTORS FOR NEUTRON DETECTION Prof. Christer Fröjdh Mid Sweden University.
Progress with GaAs Pixel Detectors
Silicon microstrip detector for imaging of fast processes at high intensity synchrotron radiation beam. Budker INP V.Aulchenko1,2, L.Shekhtman1,2, B.Tolochko3,2,
Development and characterization of the Detectorized Phantom for research in the field of spatial fractionated radiation therapy. D. Ramazanov, V. Pugatch,
V.M. Pugatch Kiev Institute for Nuclear Research
The response function of semiconductor pixel detectors for highly ionizing particles Jan Jakubek, P. Soukup Institute of Experimental and Applied Physics,
Angela Gligorova on behalf of the AEgIS and Medipix collaborations
Development of Gas Electron Multiplier Detectors for Muon Tomography
PERFORMANCE OF THE METAL RADIATION MONITORING SYSTEMS
Gain measurements of Chromium GEM foils
Presentation transcript:

PIXEL2010. V. Pugatch.1 Metal and Hybrid TimePix Detectors Imaging Beams of Particles M. Campbell, L. Tlustos, X.Llopart, CERN S. Pospisil, IEAP, Prague V. Storizhko, V. Eremenko, S. Homenko, A. Shelekhov, IAP NASU, Sumy A. Chaus, O.Kovalchuk, O. Okhrimenko, D. Storozhik, INR NASU, Kiev Valery Pugatch Institute for Nuclear Research National Academy of Sciences Kiev, Ukraine & PIXEL2010. Grindelwald. September 6-10, 2010

PIXEL2010. V. Pugatch.2 Content Introduction Hybrid (Silicon) TimePix measuring and imaging low energy ion beams: –at the focal plane of the laser mass-spectrometer –at the ion source Metal TimePix Detector: –Metal detectors of radiation – physics and technique. –Measuring and imaging low energy ion beams at the focal plane of the laser mass-spectrometer FUTURE - Metal Micro-detectors readout by TimePix for measuring and imaging beams Summary and Outlook.

PIXEL2010. V. Pugatch.3 Nuclear Physics (HEP Department including)Nuclear Physics Atomic Energy Solid-State Physics Plasma Physics Radiobiology and Radioecology Facilities: Isochronous Cyclotron U-240, Tandem ЕSG-10К, Cyclotron U-120, Nuclear Reactor WWR-M.Isochronous Cyclotron U-240Tandem ЕSG-10К Cyclotron U-120Nuclear Reactor WWR-M Isochronous cyclotron beams: Protons up to 100 MeV Deuterons – up to 60 MeV Alpha – 120 MeV Heavy ions (Ne, Ar, Xe) – 120 Z 2 /A MeV/nucleon Institute for Nuclear Research National Academy of Sciences Kiev, Ukraine. 5 Sections:

PIXEL2010. V. Pugatch.4 Introduction Recent years - significant achievements in miniaturization of mass spectrometers. Many areas of science and technology need such devices providing simultaneous measurement of wide mass- spectra in real time. This progress occurred, in particular, due to micro- detectors and readout electronics developments for High Energy Physics experiments. Microstrip as well as micropixel detectors could be applied to create the Electronic Focal Plane (EFP) for mass spectrometers.

PIXEL2010. V. Pugatch.5 EFP - Current status: SEM, MCP, Micro-Faraday cup arrays etc., Requirements: –Large dynamic range: up to 10 7 – 10 8 –Sensitivity to a single ion –Real time data simultaneously over all chemical elements These studies: TimePix evaluation for measuring and imaging low energy ions beams: – at the focal plane of the laser mass-spectrometer – at the ion source : Hybrid & Metal - response over 256 x 256 pixels. Future radiation hard Metal Micro-detectors+TimePix for ion and synchrotron beams Introduction (continued)

PIXEL2010. V. Pugatch.6 The goal of the studies: TimePix response as a function of: 1. Ion energy (3 – 40 keV) 2. Ion mass (H, He, Al, Cu, Zr, Nb, Sn, Ta, Pb) 3. Ion charge (1 +, 2 +, 3 +, 4 + ) 4. Ion beam position over 256 x 256 pixels. Hybrid (Silicon) TimePix measuring and imaging low energy ion beams: at the focal plane of the laser mass-spectrometer at the ion source

PIXEL2010. V. Pugatch.7 Hybrid pixel detector with the n-Silicon sensor chip and the TimePix electronics chip connected via bump bonds. Hybrid (Silicon) TimePix at the focal plane of the laser mass-spectrometer L.Tlustos

PIXEL2010. V. Pugatch.8 Schematics of the ion path in a laser mass-spectrometer. (Institute of Applied Physics NASU, Sumy, Ukraine.) Ions: H – Pb, 1 + <= Z <= 4 +, 3 – 80 keV. 1 – Laser, 2 – Target, 3 – Accelerator, 7 – energy analyzer, 9 – Magnet, 10 – TimePix, 11 – Focal plane The TimePix chip was mounted in a vacuum chamber on a moveable platform at the focal plane of a laser double-focusing mass spectrometer.

PIXEL2010. V. Pugatch.9 Ужгород, травня 2007 TimePix at the focal plane of the Laser Mass Spectrometer.

PIXEL2010. V. Pugatch.10 TimePix at the focal plane of the laser mass-spectrometer Ions beam has been generated at the sample-target by the infrared (1064 nm) laser (15 ns, 50 Hz). Passing through the magnetic sector ions were focused accordingly to their mass over charge ratio in a focal plane (210 mm long) of the mass-spectrometer. For each bunch of ions detected by a pixel a triangular pulse is formed with a height proportional to a number of ions in a bunch. Whenever the new bunch of ions arrives at the pixel its counter content is increased accordingly to the number of ions in the bunch. TimePix chip was readout by the PIXELMAN hardware/software (IEAP, Prague) via USB-connection to PC. Real-time digital information, high speed communication and data transfer are essential features of TimePix chips for a mass- spectrometry.

PIXEL2010. V. Pugatch.11

PIXEL2010. V. Pugatch.12 TimePix at the focal plane of the Laser Mass Spectrometer. TOT mode - For each bunch of ions detected by a pixel a triangular pulse is formed with a height proportional to a number of ions in a bunch. Whenever the new bunch of ions arrives at the pixel its counter content is increased accordingly to the number of ions in the bunch. The effect of the non-linearity at the TOT value lower than 6.5 μs has to be taken into account for obtaining correct mass-spectrum These studies: THL = 390 – 395, Integration – ( 0.1 – 5) s

PIXEL2010. V. Pugatch.13 Studies performed (July 2008 – August 2010) TimePix (Hybrid and Metal) – 2 & 2 samples. Uniformity of response over : – ion energy ( keV) – ion charge (1 + – 4 + ) and mass (H- Pb) – position of an ion beam at the detector surface

PIXEL2010. V. Pugatch.14 Two dimensional data on-line – ‘electronic photo-plate’ – for alignment, focusing, verifying stability of electric and magnetic fields etc.,) A powerful tool in a feedback system for fine tuning of a mass- spectrometer and similar devices. X – axis – along the focal plane (mass-spectrum) Y – axis – along the image of the laser beam spot at the target Z – axis – intensity of the analyzed ions Hybrid (Silicon) TimePix at the focal plane of the laser mass-spectrometer 2D mass spectrum. Position of the TimePix, Accelerating voltage, Magnetic field adjusted – to observe 12 keV 2 + ions of Pb isotopes

PIXEL2010. V. Pugatch.15 Hybrid (Silicon) TimePix at the focal plane of the laser mass-spectrometer Mass-spectra obtained by projection of the 2-D distribution onto the mass axis. Resolution is good enough to separate single mass unit different lead isotopes.

PIXEL2010. V. Pugatch.16 TimePix (Hybrid-1) - response over 256 x 256 pixels. Review of the results measured by two samples of the TimePix (Hybrid) Copper isotope peaks observed at three pixel regions (0.0, 2.8 and 5.6 mm along the focal plane) by increasing the magnetic field. The ratio of 63 Cu/ 65 Cu varies by the order of magnitude (Sample 1)

PIXEL2010. V. Pugatch.17 TimePix (Hybrid-1). Position dependence of the pixels response: 63,65 Cu and Ta single-charged ions. Order of magnitude non-uniformity over different regions of the TimePix chip (Hybrid) – Sample Cu 65 Cu Ta

PIXEL2010. V. Pugatch.18 9 areas - (85 x 85) pixels each: TOP, MIDDLE and BOTTOM part of the TimePix surface TimePix (Hybrid-1) response uniformity Al-ions, 1 +, E = 12.1 keV (Sample 1).

PIXEL2010. V. Pugatch.19 Non-uniform response (Sample 1) dependent on the ion charge and position. Uniformity of the TimePix (Hybrid-1) response. Zr/Nb – isotopes mass-distribution for ions.

PIXEL2010. V. Pugatch.20 Uniformity of the TimePix (Hybrid-1) response. Zr/Nb – isotopes mass-distribution for ions. Uniformity of response is a crucial feature for a sensor imaging mass distribution. Results obtained for the TimePix (Sample1) show irregularity in response by different pixels. Acceleration voltage = 12.1 kV

PIXEL2010. V. Pugatch.21 Irregularities in TimePix (Hybrid-1)- response to 14 C – beta-particles 14C. Depletion voltage – 0 V. Order of magnitude difference in response 14 C. Depletion voltage – 100 V. Factor of 4 – difference in response.

PIXEL2010. V. Pugatch.22 Factor of 3 difference in the response of MEDIPIX-2 (Hybrid) to He and H 2 ions of the same energy. Ion source at the KINR isochronous cyclotron U-240. The response variation over the surface of the detector (Sample 1) exceeds order of magnitude. The most probable reason – varying thickness of the Si-sensor dead layer (0.1 μm - range). Aperture: 3 holes, 1mm diameter separated by 4 mm Energy of ions – 30 keV. Response of MEDIPIX-2 (Hybrid-1) to low energy ions.

PIXEL2010. V. Pugatch.23 Medipix-2 (Hybrid-1) response to a sunlight - affected by the irradiation of ions at U-240 – thin layers of Al – were deposited (~ 50 nm). Preliminary conclusion: non-uniformity of the response is determined by non-uniformity of the dead-layer thickness over the Medipix-2 (hybrid)

PIXEL2010. V. Pugatch.24 TimePix (Hybrid-2) response uniformity TimePix (Hybrid) – Sample 2. Zr - ions, 2 +, E = 19 keV Perfect (+/- 1 %) uniformity of the response ! Table:

PIXEL2010. V. Pugatch.25 TimePix (Hybrid-2) response uniformity TimePix (Hybrid) – Sample 2. Zr - ions, 2 +, E = 25.2 keV +/- 1 % uniformity of the response !

PIXEL2010. V. Pugatch.26 TimePix (Hybrid-2) Response dependence on energy and beam position (Top, Middle, Bottom area of the chip) for Zr – 2 + ions.

PIXEL2010. V. Pugatch.27 TimePix (Hybrid-2) ‘Charge quantum’ dependence on the ion energy. Zr (2 + ).

PIXEL2010. V. Pugatch.28 TimePix – Metal Detector Test of the TimePix readout chip as a metal detector at the focal plane of the laser mass-spectrometer Photo of the individual pixels of the TimePIx chip (55 x 55 μm 2, 256 x 256 pixels) CERN, MEDIPIX Collaboration. Diameter of the area for bonding ~15 μm. A positive voltage has been applied to a mesh over the chip area – to collect Secondary electrons emitted by metal surface of the chip under the impinging low energy ions at the focal plane.

PIXEL2010. V. Pugatch.29 Metal Detectors. Physics principle.

PIXEL2010. V. Pugatch.30 Metal Detector. Technical realization. Metal Foil Detector technology allows for Building any size beam monitoring systems: HERA-B Luminosity monitoring, LHCb Radiation Monitoring system BPM for 21 MeV proton beam (tandem MPIfK) BPM for the LHCb (ST) test beam studies 19 keV Synchrotron BPM at HASYLAB 5 MeV Electron beam BPM - KINR

PIXEL2010. V. Pugatch.31 Radiation Monitoring System Silicon Tracker, LHCb. Metal Detectors at LHCb M.I.P.

PIXEL2010. V. Pugatch.32 TimePix – Metal Detector in a focal plane of the laser mass-spectrometer. TimePix Metal performance for low energy ions 14 th Nov The TimePix (Sample1) was used to improve focusing: the vertical size is ~ 3 times less, now! 20 th May. 2009

PIXEL2010. V. Pugatch.33 X – axis – along the focal plane (mass-spectrum) Y – axis – along the image of the laser beam spot at the target Z – axis – intensity of the analyzed ions TimePix (METAL-1) in a focal plane of the laser mass-spectrometer. 2D mass spectra of sample with Zr 2+ – isotopes. Energy of ions 12,3 keV Two dimensional data on-line – ‘electronic photo-plate’ – for alignment, focusing, testing stability of electric and magnetic fields etc.,) A powerful tool in a feedback system for fine tuning of a mass-spectrometer and similar devices.

PIXEL2010. V. Pugatch.34 TimePix (METAL-1) in a focal plane of the laser mass-spectrometer. 1 % response variation of TimePix (Sample1) different pixels Table: Suppression of the low intensity beam ( 96 Zr) – non-linear TOT operation at low input charge

PIXEL2010. V. Pugatch.35 Response of the TimePix (Metal-1) to Cu isotopes as a function of ion (2 + ) energy

PIXEL2010. V. Pugatch.36 Comparison of the TimePix Hybrid/Metal sensitivity to low energy ions The number of Zr (2 + ) ions per 1 count of the TimePix (Hybrid-2) at 25.2 keV is ~ 6 The number of Zr (2 + ) ions per 1 count of the TimePix (Metal-2) at 25.2 keV is ~ Geometry factor (ratio of active sensor surface) - ~ 30 Thus, Hybrid/Metal factor of sensitivity is ~ 33. Very thin surface layer of the silicon sensor contributes.

PIXEL2010. V. Pugatch.37 TimePix (METAL-2) in the focal plane of the laser mass-spectrometer TimePix (Metal-2) Response at different positions of 2 + ion beams (Superimposed data of three measurements) Mapping isotope population over the sample area by scanning it with laser or charged particle micro-beam might be useful for applications in material technology, microbiology, medical diagnostics etc.

PIXEL2010. V. Pugatch.38 TimePix (METAL-2) in the focal plane of the laser mass-spectrometer TimePix (METAL-2) response at different positions of ion (Charge 2 + and 3 + ) beams and operating voltage (0 and 70 V)

PIXEL2010. V. Pugatch.39 TimePix (METAL-2) in the focal plane of the laser mass-spectrometer Table: Suppression of the low intensity beam ( 96 Zr) – result of the non-linear TOT operation at low input charge U det = 70 V

PIXEL2010. V. Pugatch.40 TimePix(METAL-2) in a focal plane of the laser mass-spectrometer U det = 0 V Suppression of the low intensity beam ( 96 Zr) – the result of the non-linear TOT operation at low input charge Table:

PIXEL2010. V. Pugatch.41 Image of the grid wires Wires diameter – 50 μm TimePix (METAL-2) in the focal plane of the laser mass-spectrometer

PIXEL2010. V. Pugatch.42 Future work Test a prototype of the Electronic focal plane: –5 TpX in collaboration with C. Ponchut (ESRF) –+ MCP. Single ion detection sensitivity at few keV energy 27 Al (1 + ) –ions has been demonstrated for MCP + CMOS active pixel sensors

PIXEL2010. V. Pugatch.43 Future: Electronic Focal Plane. –Metal Strip & Pixel Detectors – – for Beam Profile Monitoring at the submicron level. – Currently available – – 1024 strips metal detector, –60 μm pitch.

PIXEL2010. V. Pugatch.44 Future: Metal Micro Detectors for BPM MMD-64. MMD- 16 sector pixels Advantages of the MMD: High Radiation tolerance ( MGy) Nearly transparent sensor – 1 μm thickness Low operation voltage (20 V) Spatial resolution (5 – 25 μm) Well advanced production technology Commercially available readout hardware and software.

PIXEL2010. V. Pugatch.45 MMD could be helpful in Particle Therapy From : Ken Peach (UK) Summary talk. “ Physics for Health in Europe”. CERN, 2010 MMD – an ideal monitoring device: present in the beam, permanently does not disturb a beam measures X-Y dose distribution provides self-control of functionality operates reliable over high doses

PIXEL2010. V. Pugatch.46 The TimePix (Hybrid and Metal) response to low (3 – 40 keV) energy ions has been studied as a function of ion mass, charge, energy and beam position. The TimePix (Hybrid) chips have demonstrated sample dependence of the pixels response. The pixels response is more uniform (+/- 1 %) for the TimePix (Metal) mode operation. The possibility of building electronic focal plane of the mass- spectrometer based on the TimePix detector operated in a metal mode has been demonstrated. The TimePix (Metal & Hybrid) (5 chips systems) will be evaluated soon as a demonstrator of the 'Electronic Focal Plane'. Metal micro-detectors are on the way to become super-thin (transparent) radiation hard detectors for measurements of intensity distribution of the particles beams. SUMMARY and OUTLOOK

PIXEL2010. V. Pugatch.47 Acknowledgements We would like to thank –MEDIPIX Collaboration – Valkov & Kolessov – KINR, U-240 team. This work was funded partially by the CNCP (UK) project “Microstrip Metal Detectors”.

PIXEL2010. V. Pugatch.48 Thank you for your attention !