Evolution Daikin Chiller Range

Slides:



Advertisements
Similar presentations
Water Source Heat Pump Systems
Advertisements

Refrigeration Systems
ENERGY SAVING Product Offering COMPRESSOR MARKETING OPPORTUNITIES.
Evolution Daikin Chiller Range
Overall issues for adequate design for high-ambient temperature operation by: Samir Hamed Petra Engineering Ind. Co. Rtoc member.
Thermosyphon - Free Cooling
Mammoth Product Training
Aqualean Product Presentation 1 By Laurent Domenget Product Manager, Rooftop & Packaged Air Units.
RLC-CMS002-E4© American Standard Companies, inc All Rights Reserved Concentration of intelligence, High reliability. Series R TM.
McQuay International Residential Commercial Institutional Industrial
 Install new air cooled high efficiency screw chiller (variable speed)  Install new fan coils with ECM motors and low temperature heating coils and proper.
Refrigeration Terms Cooling Load, Cooling Capacity – Q in Compressor Load – W in Condenser Load – Q out Tons of Refrigeration – Rate of Heat Input Refrigerant.
EWWD-MBYNN EWLD-MBYNN
Applied Systems Single Screw Chillers STEPLESS CAPACITY CONTROL.
EWAP-MBYNN Air-cooled Applied Systems Sales.
Perfect solution for large building
Air conditioning – Refreshes your life Mini-Chiller Applied Systems Sales1 EWA(Y)Q-AAV3P Residential Mini-Chiller Heating EWAQ - AA3VP EWYQ - AAV3P Cooling.
Air Conditioning Circuit
EWWD 380-C11 BJYNN Sep-15 Water Cooled Chiller 369 kW ÷ 1050 kW Single Screw Compressor EWWD 380-C11 BJYNN.
Air conditioning – Refreshes your life EWTP MBY Applied Systems Sales1 EWTP-MBYNN Air-cooled Heat Recovery.
Air conditioning – Refreshes your life EWAD MBY Applied Systems Sales1 EWAD-MBYNN Air-cooled.
22-Apr-17 EWWD DJYNN.
22-Apr-17 EWWD340-C19CJYNN.
22-Apr-17 EWAD AJYNN.
EWWD DJYNN Sep-15 Water Cooled Chiller 166 kW ÷ 604 kW Single Screw Compressor EWWD DJYNN.
MCS’S MAGNUM DIAGNOSTICS PACKAGE Visit us at
Heat Transfer Equations For “thin walled” tubes, A i = A o.
© Alfa Laval Pure Cooler R134a r-evolution New high efficiency R134a dedicate evaporator. Pure Cooler Passes (tube side)1 Tube arrangementStraight.
How a Heat Pump Works By: Adam Meeker. What is a Heat Pump? A heat pump is a device which transfers heat energy from one place to another.
AIR-COOLED SCREW CHILLER FAS Air-Cooled Screw Chiller – FAS-E (Low Noise)
The Refrigeration Process
Flooded Screw Chiller FWSF Electronic Expansion Valve Condenser Evaporator Control box compressor Flooded Screw Chiller - FWSF.
/ 1 ERA A chiller to suit everyone. Air cooled water chillers Free-cooling chillers Air/water heat pumps.
Introduction Advanced energy recovery heat pump for the Engineering Science and Research Building (ESRB). ESRB uses 54,000 CFM of 100% make-up air 24 hours.
BCWC Water-cooled water chillers with centrifugal compressor/s
Schneider Electric: Total Cooling Solutions for Data Centers
HEAT PUMPS BY: DINESH BAKTHAVATSALAM ID#: M-I.
1 BREC Air-cooled water chillers BREF Air-cooled water chillers with free-cooling system 1602A A A A A 3202A A A -
MULTISTACK WORLD-WIDE HEADQUARTERS SPARTA, WISCONSIN.
Large Tonnage Chiller WC Screw.
Heat Transfer Equations For “thin walled” tubes, A i = A o.
Air cooled screw chiller Introduction Product line up Features Applications Certifications Reference projects.
Status of the Marco chiller and Marco capacity analyses Bart Verlaat, Lukas Zwalinski, Maciej Osterga, Jan Godlewski MPI Munich,1 March.
B26 The AsyMatrix Condenser for Heat Pumps Powerful, just smaller.
Refrigeration What's Refrigerated? What makes up a system?
2016 Chiller New Products Presentation.
1 Summer Training On Refrigeration and Air Conditioning From:-Amber Enterprises PVT.LTD.
Air Cooled Chillers with High Speed Centrifugal Compressors.
CHIGO HVAC Product Introduction.
Compact line ‘EW*D~J-’ water-cooled chiller range
Book E3 Section 1.4 Air-conditioning
ARAC/H/F Air-cooled water chillers, free-cooling chillers and heat pumps Range: kW.
Chillers for Tomorrow… Today
HVAC EQUIPMENT: COOLING SOURCES (see Chapter 16)
The Basic Direct Expansion Refrigeration Cycle
2016, 9-11 & 13 May RTWF RTHF.
ATLAS Thermosiphon Electrical Distribution and Run Modes
DC Inverter Air-cooled Chiller Aqua Tempo Super II Series
New Air Cooled Scroll Chiller
Air Conditioning System-1
VITALITY Large Splits Johnson Controls PowerPoint Guidelines | July 21, 2009.
Title RTWD Water-Cooled Chillers subtitle START
Dunham Bush Air Cooled Package
NRL NRL - Welcome to the NRL Sales Training Program
NRL NRL - Welcome to the NRL Sales Training Program
Radhey S. Agarwal Member, OORG
NRL NRL - Welcome to the NRL Sales Training Program
NRL NRL - Welcome to the NRK Sales Training Program
NRL NRL - Welcome to the NRL Sales Training Program
Presentation transcript:

Evolution Daikin Chiller Range Daikin branded McQuay products

Not in scope Under realignment Air Cooled Product Range McSmart Minichiller 6 40 Not in scope 5 39 McSmart 48 155 47 145 177 MCENERGY 401 Under Investigation 221 HPI 421 Under realignment Energyplus “B” 363 624 Up to 1920 kW 606 ALS Up to 1729 kW MCPOWER 744 kW 100 200 300 400 500 600 700 800 900 1000 1100 Applied Systems

A/C 50 100 250 500 750 1000 1250 1500 kW R-410a Minichiller: EWA/YQ005-007ABV3P EUWA/Y5-24KZW EWA/YP060-260CAYNN DAIKIN R-407c EWAP110-540MBYNN EWAP800-C18AJYNN EWAD120-600MBYNN EWAD650-DC18BJYNN R-134a EWAD190-360AJYNN McEnergy Screw 177-401kW Extension 400-600kW R-134a MHI 221-421kW McQuay ALS Screw 606-1920kW R-407c McPower Screw 744-1729kW

McQuay Single-Screw Compressor (Frame4) ALS EWAD650-C18BJYNN Frame4 Cooling Range: 606 – 1920 kW McQuay Single-Screw Compressor (Frame4) 2 efficiency versions: Std up to 2,93 and High up to 3,32 (EER) 2 – 3 – 4 truly independent refrigerant circuits DX shell & tube evaporator – One pass refrigerant side 4 noise levels (ST-OPRN-OPLN-Q/Z) down to 65 dB(A) R134a Ecologic Refrigerant Applied Systems

McQuay Single-Screw Compressor (Frame4) MCPOWER EWAP800-C18AJYNN Frame4 Cooling Range: 744 – 1729 kW McQuay Single-Screw Compressor (Frame4) 2 efficiency versions: Std up to 2,34 and High up to 2,69 (EER) 2 – 3 truly independent refrigerant circuits DX shell & tube evaporator – One pass refrigerant side 3 noise levels (ST-OPRN-OPLN) down to 72,5 dB(A) R407C Ecologic Refrigerant @ ISO 3744 Applied Systems

McQuay Single-Screw Compressor (Frame3100) MCENERGY EWAD190-360AJYNN Frame3100 Cooling Range: 177 – 401 kW McQuay Single-Screw Compressor (Frame3100) 2 efficiency versions: Std up to 2,77 and High up to 3,13 (EER) 2 truly independent refrigerant circuits DX shell & tube evaporator – One pass refrigerant side 4 noise levels (ST-OPRN-OPLN-Q/Z) down to 62 dB(A) R134a Ecologic Refrigerant Applied Systems

Under realignment ENERGYPLUS Cooling Range: 363 – 624 kW Frame3200 Cooling Range: 363 – 624 kW McQuay Single-Screw Compressor (Frame3200) 2 efficiency versions: Std up to 2,84 and High up to 3,11 (EER) 2 truly independent refrigerant circuits DX shell & tube evaporator – One pass refrigerant side 4 noise levels (ST-OPRN-OPLN-Q/Z) down to 65 dB(A) R134a Ecologic Refrigerant Under realignment Applied Systems

Not in scope Phasing out Under realignment Not in scope in 1st phase Water Cooled Products Cooling Capacity Range 85 166 WHZ Not in scope Up to 1893 kW WHS 334 Phasing out 344 WHS XE 957 ECOPLUS 166 604 Up to 2192 kW Under realignment 250 Extension PROXIMUS 729 PFS 369 1050 Up to 9000 kW Not in scope in 1st phase 300 WSC - WDC kW 100 200 300 400 500 600 700 800 900 1000 1100

WSC/WDC Centrifugal 300-9000kW W/C 50 100 250 500 750 1000 1250 1500 EWWP014-065KAW1N Scroll R-407C DAIKIN EWWD120-540MBYNN EWWD170-600DJYNN R-134a EWWD340-C19CJYNN EWWD360-C11AAYNN EWWD380-C11BJYNN R-410a EWWQ750-C20AJYNN R-410a Extension 250-700 Proximus 729-2192kW Ecoplus 166-541kW McQuay R-134a WHS 334-1893kW PFS 369-1050kW WSC/WDC Centrifugal 300-9000kW

McQuay Single-Screw Compressor (Frame4) EER range: 4,1 – 4,6 WHS EWWD340-C19CJYNN Frame4 Cooling Range: 334 – 1893 kW McQuay Single-Screw Compressor (Frame4) EER range: 4,1 – 4,6 1 – 2 – 3 – 4 truly independent refrigerant circuits DX shell & tube evaporator – One pass refrigerant side Electronic Expansion device as standard R134a Ecologic Refrigerant Applied Systems

VERY HIGH PART LOAD PERFORMANCE PFS EWWD380-C11BJYNN Frame4 Cooling Range: 369 – 1050 kW McQuay Single-Screw Compressor (Frame4) EER up to 5,8 Very high EER values at part loads condition Flooded Evaporator Expansion valve with liquid level control R134a Ecologic Refrigerant VERY HIGH PART LOAD PERFORMANCE Applied Systems

McQuay Single-Screw Compressor (Frame3200) ECOPLUS EWWD170-600DJYNN Frame3200 Cooling Range: 166 – 604 kW McQuay Single-Screw Compressor (Frame3200) 2 efficiency versions: Std up to 4 and High up to 4,7 (EER) 1 – 2 truly independent refrigerant circuits DX shell & tube evaporator – One pass refrigerant side Electronic Expansion device as standard R134a Ecologic Refrigerant Applied Systems

Under realignment PROXIMUS EWWQ750-C20AJYNN Frame4 Under realignment Cooling Range: 729 – 2192 kW (extension planned down to 250kW) McQuay Single-Screw Compressor (Frame4) 2 efficiency versions: Std up to 4,6 and High up to 5,2 (EER) 1 – 2 truly independent refrigerant circuits Very compact design to minimize unit footprint Electronic Expansion device as standard R410A Ecologic Refrigerant Applied Systems

Phasing out WHS - XE Cooling Range: 344 – 957 kW Frame4 Cooling Range: 344 – 957 kW McQuay Single-Screw Compressor (Frame4) 1 – 2 truly independent refrigerant circuits DX shell & tube evaporator EER range: 5,10 – 5,19 Electronic Expansion device as standard R134a Ecologic Refrigerant Phasing out Applied Systems

Not in scope in 1st phase WSC/WDC Centrifugal chillers Cooling Range: 300 – 9000 kW McQuay Centrifugal Compressor (Single & Dual) Available with VFD (Variable Frequency Driver) to reach amazing EER, both at 100% and part loads (EER up to 12) Total Heat Recovery & Heat Pump (Templifier®) version Smart software to optimize unit selection Unit selection program certified by ARI Applied Systems

Overview on Nomenclature Daikin branded McQuay products

Overview nomenclature A/C Applied Systems

Overview nomenclature W/C Not for B07 purposes ME (remote condenser) and LR (remote condenser with liquid receiver) will be handled under SPN. Applied Systems

Noise & Efficiency Std Noise, Std Efficiency Base Model OPRN: Reduced Noise, excludes compressor cabinet OPLN: Low Noise, includes compressor cabinet Std Noise, High Efficiency “A” Base Model Super Quiet, Std Efficiency “Q” Base Model Super Quiet, High Efficiency “Z” Base Model High Ambient = “H” Base Model Applied Systems

Standard Daikin Options A/C Note: OPAL will be offered as a negative option Applied Systems

Standard Daikin Options W/C Applied Systems

Standard Options Available Applied Systems