Cabling Policy for KAGRA ISC Yuta Michimura Ando Group Department of Physics, University of Tokyo March 14, 2016.

Slides:



Advertisements
Similar presentations
Audio Cables and Connectors. Common Audio Cables Balanced: Have two conductors and a shield or ground. Used for low impedance - balanced circuits (+4.
Advertisements

KAGRA ISC Electrical Components Layout Yuta Michimura Ando Group Department of Physics, University of Tokyo April 17, 2015.
Connectors Connectors are a major cause of equipment failure. Pins are wired incorrectly, bare wires touch and short circuit or connector pins are accidently.
RADIO FREQUENCY MODULE. Introduction  An RF module is a small electronic circuit used to transmit and receive radio signals.  As the name suggests,
Power supply cable Charge injection 3 channels readout (external cables to the scope) 3 channels readout (internal cables) Set up for reading two cards.
CR1000s are only one part of a data acquisition system. To get good data, suitable sensors and a reliable data retrieval method are required. A failure.
Internal Seismic Isolation (ISC) Overview Report for the August CDS meeting Ben Abbott Caltech.
CR1000s are only one part of a data acquisition system. To get good data, suitable sensors and a reliable data retrieval method are required. A failure.
Electronics and Cables around IMC Common Mode Servo Board Yuta Michimura Ando Group Department of Physics, University of Tokyo August 10, 2015.
General Licensing Class Your Receiver Your organization and dates here.
1 Why have we chosen to use the serial port, when it is more complicated and offers fewer connections than the printer port? For a beginners’ course using.
D Star Digital Data (DD) Buddy Morgan WB4OMG Trustee KJ4ACN D Star Repeater, Lakeland, FL
Software Defined Radio
POWER PLANT USED IN TELECOM
Senior Design 4006C Group G7 Design Presentation 1394b – Receiver The new generation of FireWire. Luke Starnes (gte874d) Aparna Trimurty (gt9794a) Jeff.
Electrical Considerations Eargle, Ch. 8 (partial).
U.B. Presentation October Bernard COURTY L.P.C.C. College de France - Paris.
Datron World Communications Inc. RT7000 HF TRANSCEIVER FIELD MAINTENANCE PROCEDURES.
Installation and checkout of QBPM system Hardware to be installed –Install hardware in racks –Install CPU /SIS digitizers/VMIC 3122 analog digitizers/Digital.
6.9 How radio works 22 October 2015 What is this image? What other information can you get from it?
BNCDB9 F Pin 1 – Center (Red)6 1 – Shield (Black)1 2 – Center (Yellow)8 2 – Shield (Black)3 D OMC Tip-Tilt Adaptor Cable BNC 1(1,6) BNC 2(3,8)
Optical Levers Layout and Cabling Yuta Michimura, Yuya Kuwahara Ando Group Department of Physics, University of Tokyo November 19, 2015.
Requirements concerning the interface linking the BPM to the quadrupole M. Wendt, S. Zorzetti.
1 4 PCB: LEFT TOP 115 channels, LEFT BOTTOM (115), RIGHT TOP (106), RIGHT BOTTOM (106). For LEFT TOP board 115 channels we have: 115 smd connectors (AMP.
QBPM System Installation Systems –Rack mount chassis –LO and CAL RF cable plant ( need 714Mhz from eels bedroom) –Down mix boxes –DC power cable plant.
Adapting the LHC 1TFB electronic circuit to other equipments The candidates are: PS 1TFB PS TFB PS CBFB PSB TFB PSB 1TFB 1 Alfred Blas Working group meeting.
March 9, 2005 HBD CDR Review 1 HBD Electronics Preamp/cable driver on the detector. –Specification –Schematics –Test result Rest of the electronics chain.
KAGRA ISC Electrical Components Layout Yuta Michimura Ando Group Department of Physics, University of Tokyo December 8, 2015.
Connectors & Cables © D. J. McMahon rev
Getting faster bandwidth HervéGrabas Getting faster bandwidth - Hervé Grabas1.
EQUIPMENT. Radio Transceiver (and Amplifier) Transceiver Block Diagram.
RF over Fiber - Application Riedel solutions for broadcast applications 1 Application Examples – RF over Fiber.
MSK-200 TV Signal Analyzer 6-In-One TV Test Solution  Installation, repair and maintenance of professional Analog and Digital terrestrial, CATV and satellite.
1. Students will understand the function of the equipment associated with a closed circuit TV system. 2. Students will understand the function and purpose.
Krzysztof Czuba, ISE, Warsaw ATCA - LLRF project review, DESY, Dec , XFEL The European X-Ray Laser Project X-Ray Free-Electron Laser Master Oscillator.
Arm Length Stabilization Conceptual Configuration Yuta Michimura Department of Physics, University of Tokyo JGW-T November 14, 2016.
Radio Communication SL/HL – Option F.1. Radio communication includes any form of communication that uses radio (EM) waves to transfer information –TV,
NSG 4070 Signal generator and immunity test system Dr. Heinrich
AMATEUR RADIO TRAINING
Main Interferometer Subsystem
MULTISTAGE AMPLIFIERS
Veto Readout Electronics-The Big Picture
Multiplication table. x
Electronics and Cables around IMC Common Mode Servo Board
Chassis Power Regulator Board
TNC Male Clamp/Solder connector
BNC Female Bulkhead connector
SMA Male Right Angle connector
COVER Full production should arrive today
RF cables calibration Matteo Volpi Thomas Geoffry Lucas
Electronics: Demod + 4Q FE
Electronics: Demod + 4Q FE
Pierluigi Paolucci - I.N.F.N. Naples
Arm Length Stabilization Conceptual Configuration
Arm Length Stabilization Conceptual Configuration
Multimedia Training Kit
Cartoon of the optical layout around IMC, IFI and IMM
RF and DC Cabling Policy for KAGRA ISC
Chassis Power Regulator Board
Coaxial Cables & Connectors
RF Hybrids Jeffrey E Brown Georgia Transmission Corporation
Report on ATF2 Third Project Meeting ATF2 Magnet Movers ATF2 Q-BPM Electronics Is SLAC ILC Instrumentation Group a good name?
RF and DC Cabling Policy for KAGRA ISC
RF Distribution Amplifier Top Assembly 1U (JGW-D )
Arm Length Stabilization Conceptual Configuration
KAGRA ISC Electrical Components Layout
Products FM Radio Rebroadcast Unit– RFR-2J0 ]
Preparation for Installation at ESS
KAGRA ISC Electrical Components Layout
Presentation transcript:

Cabling Policy for KAGRA ISC Yuta Michimura Ando Group Department of Physics, University of Tokyo March 14, 2016

Summary of RF/AF cabling policy discussed at IOO and ISC mailing list, and Kamioka References: - JGW-D (electronics racks layout) - JGW-D (Cabling around PSL+IMC) - JGW-D (ISC rough layout and cabling) - JGW-D (Oplev rough layout and cabling) - JGW-D (cable racks layout) - JGWwiki/KAGRA/Subgroups/DGS/Projects/STDA/Dsub9 (Dsub cable policy for avoiding ground loops)JGW-D JGW-D JGW-D JGW-D JGW-D JGWwiki/KAGRA/Subgroups/DGS/Projects/STDA/Dsub9 Abbreviations - RF: radio frequency (~10 kHz to ~100 MHz) - AF: audio frequency (DC to ~ 10 kHz) Scope 2

Use N-connectors for RF oscillators, RF distributors, and RF delay-line Use N-N low loss cables for table to rack, rack to rack cabling (Fujikura 12D-SFA-LITE (LMR600 like) ) - You can use N-N flexible cable if the length is <10m Use SMA-SMA flexible cable for cabling around a table, around a rack (HUBER+SUHNER S04272B (LMR195 like) ) SMA-SMA, N-N cables should be male-male N-SMA conversions will be done at patch panels Use N-SMA conversion connectors when there’s no patch panel for that cabling path Use SMA connectors for RFin/out in circuits Do not use BNC, LEMO (they make glitches), TNC, etc. (they add extra complexity) RF Cabling Policy 3

Use Dsub 9 pin male-female cables for table to rack, rack to rack cabling (may be should accept some exceptions to use single-ended instead; under discussion) Use TNC-TNC cables for cabling around a table, around a rack (BNC-BNC cables are accepted for monitor channels) Auxiliary slow channels should be concentrated to Dsub 9 pin at the table Use Dsub female for circuits which “send” signals (there are some exceptions, i.e. RF PD and RF QPD) Use Dsub male for circuits which “receive” signals (there are some exceptions) Do not use 2-pin (multiple pin) LEMO Dsub 15pin for QPDs Dsub 37pin for Binary Inputs/Outputs AF Cabling Policy 4

Cabling example can be found in JGW-D JGW-D Cabling Example 5