SIDE SCAN HARDWARE CONFIGURATION HYPACK 2015. Connection Block Diagram GPS, single beam and tide data go into HYPACK ® SURVEY. Sidescan (with optional.

Slides:



Advertisements
Similar presentations
The World Leader in High Performance Signal Processing SolutionsThe World Leader in High-Performance Signal Processing Solutions Adding a Parallel Port.
Advertisements

Module 3 Configuring Hardware on a Computer Running Windows XP Professional.
HYSWEEP® HARDWARE.
EXCAVATORS HYPACK 2013.
EUMETCast served three ways David Taylor SatSignal Software.
®® Microsoft Windows 7 Windows Tutorial 8 Connecting to Networks with Mobile Computing.
Unit Test Calibration Training
Hardware Testing Imeet web conference. Hardware Requirements 2 Windows XP Professional Office XP and above CPU: Pentium 4, 2.4 GHz Memory: 512MB and above.
Workshop 7 of 7 Welcome!. Today's Topics Data Acquisition MAX DAQ Assistant Express VI DAQmx API Create Task Configure Task Configure Trigger Start Task.
Presents The Silver Family An Integrated Approach to Processors, Data Communication and Head End Integration.
HYPACK MULTIBEAM COURSE
TOWFISH DRIVER.
MCDST : Supporting Users and Troubleshooting a Microsoft Windows XP Operating System Chapter 14: Troubleshooting Remote Connections.
Lesson 18 – INSTALLING AND SETTING UP WINDOWS 2000 SERVER.
Lesson 5-Accessing Networks. Overview Introduction to Windows XP Professional. Introduction to Novell Client. Introduction to Red Hat Linux workstation.
MCDST : Supporting Users and Troubleshooting a Microsoft Windows XP Operating System Chapter 9: Troubleshooting Power Management and I/O Devices.
HYPACK® Multibeam Training Seminar
1 Arduino Board: Arduino UNO Arduino Programing Environment: Arduino 0022
Word Processing, Web Browsing, File Access, etc. Windows Operating System (Kernel) Window (GUI) Platform Dependent Code Virtual Memory “Swap” Block Data.
 Main Components:  Sensors  Micro controller  Motor drivers  Chasis.
RIG MOVES. Step 1: Boat Shape Editor Create your boat shape. The Boat Origin Reference Point is at the X=0, Y=0 point. Set 1 or 2 anchor points. – One.
Chapter 7Assembling Your Own Computer System  7.1Assembling the Hardware 7.1Assembling the Hardware 7.1Assembling the Hardware  7.2Installing the Operating.
TAX-AIDE Network Router Setup Network Printer Setups July SMT/TCS Training - Dallas1.
Troubleshooting Hardware Issues Lesson 5. Objectives 2.
© 2006 Cisco Systems, Inc. All rights reserved.Cisco PublicITE I Chapter 6 1 Characterizing the Existing Network Designing and Supporting Computer Networks.
SURVEY VIEWER HYPACK Sending SURVEY Windows Across the Network to Non-HYPACK Computers. HYPACK Computer Non-HYPACK Computer Running SURVEY VIEWER.
Tutorial 11 Installing, Updating, and Configuring Software
U81X0 Downloading Tool Manual 1 ( Version 1.2 ) FlashRW For U81X0 Version 4.0.0(Build #95V) February 2004 LG Electronics Inc.
Managing Windows Server 2008 R2 Lesson 2. Objectives.
Dynatest LWD Program - Sections
1 Fluke DAQ Software Visual Demo Guide 2680A-APSW.
Infinity-project.org The Institute for Engineering Education Engineering Education for today’s classroom. 1 Infinity Project Laboratory Setup.
High Speed Data Converter University
Data Acquisition Data acquisition (DAQ) basics Connecting Signals Simple DAQ application Computer DAQ Device Terminal Block Cable Sensors.
Module 3: Configuring Hardware on a Computer Running Windows XP Professional.
Microsoft Windows 7 - Illustrated Unit P Managing Hardware.
HYPACK HARDWARE CONFIGURATION
DEVICE DRIVER SAMPLES.
HYPACK MAX Training Seminar Advanced Survey Topics Multivessel & Specialty Drivers Demonstrations of operating with more than one vessel & specialty.
Application Block Diagram III. SOFTWARE PLATFORM Figure above shows a network protocol stack for a computer that connects to an Ethernet network and.
PC Maintenance & Networking Material Developed Under DST – NIMAT Project (TEDP) By VidyaDeep Foundation, Satara.
Development of a microprocessor project with LPC2388 development board.
11 INSTALLING AND MANAGING HARDWARE Chapter 6. Chapter 6: Installing and Managing Hardware2 INSTALLING AND MANAGING HARDWARE  Install hardware in a Microsoft.
Computer Hardware Maintenance & Repairs Computer Hardware Maintenance & Repairs Suleiman Mohammed (mncs,mcpn) Instructor Institute of Computing & ICT,
Tutorial 12 Managing Hardware and Networks
NetTech Solutions Resolving Issues with Locally Attached Devices Lesson Twelve.
Ethernet I/O Set-Up This presentation will step through a typical configuration of the DVT CON-IOE. Intellect 1.0 is used for the software portion.
HYSWEEP® Water Column Logger and Processing
SIDE SCAN HARDWARE CONFIGURATION
SIDE SCAN SURVEY 1. Sidescan Survey Window for Display and control (1) Title Area – Will display file name with HSX extension. (2) Alarm Indicators:
HYSWEEP® HARDWARE.
HYSWEEP ® HARDWARE. HYSWEEP ® Survey Configuring a Multibeam System Multibeam sonar GPS (via HYPACK hardware) Motion sensor Heading sensor Dynamic Draft.
HYSWEEP ® HARDWARE. HYSWEEP ® Survey Configuring a Multibeam System Multibeam sonar GPS (via HYPACK hardware) Motion sensor Heading sensor Dynamic Draft.
HYPACK HARDWARE CONFIGURATION. HYPACK ® HARDWARE: Combined HYPACK HARDWARE, HYSWEEP HARDWARE & SIDE SCAN HARDWARE are now combined in a single HYPACK.
Patch Testing. HYSWEEP ® Calibration of a Multibeam System Patch Testing Single and Dual Head Multibeam Systems. Patch Testing Single and Dual Head Multibeam.
SIDE SCAN OVERVIEW. Sidescan Survey Overview A sidescan sonar can be used for a wide variety of survey operations. Search and recovery Geological Identification.
SURVEY VIEWER Note: SURVEY VIEWER functions are now available from the Remote Viewing that is built into HYPACK SURVEY. SURVEY VIEWER still works, but.
Serial Server Configuration Peter Szyszko. Hardware Configuration  Unit has to be connected to network and powered.  Computer has to be connected to.
SIDE SCAN SURVEY 1. Sidescan Survey Window for Display and control (1) Title Area (1) Title Area – Will display file name with HSX extension. (2) Alarm.
PCs ENVIRONMENT and PERIPHERALS Lecture 4. An expansion cards: - An expansion card (expansion board) is an electronic circuit board that adds more functionality.
DEVICE DRIVER SAMPLES. How Many ? How to add an update?  Currently HYPACK has between Device Drivers  There are 192 in the \HYPACK 2015\Devices.
CUTTER SUCTION DREDGES. Cutter Suction Configuration Cutter Suction Configuration ` Water Level Chart Datum Channel Design Depth Channel Design Overdepth.
SUB BOTTOM DATA 1.
CN1260 Client Operating System Kemtis Kunanuraksapong MSIS with Distinction MCT, MCITP, MCTS, MCDST, MCP, A+
Step 1 - Installing TStatSpec Download the TStatSpec software from customer.honeywell.com.  The files will need to be extracted in a new folder.  
Intro to USB-6009 DAQ.
Installing Printers Most printers are boxed with paper or Styrofoam inserts placed to ensure there is no damage during shipping. Make sure all of these.
Roller Coaster Design Project
ADC32RF45 with KCU105 Internal Clock GHz.
Presentation transcript:

SIDE SCAN HARDWARE CONFIGURATION HYPACK 2015

Connection Block Diagram GPS, single beam and tide data go into HYPACK ® SURVEY. Sidescan (with optional MRU, heading sensor, pressure sensor) goes into SIDESCAN SURVEY. Information is passed between the two using the shared memory. Use the Hysweep.dll in HYPACK ® HARDWARE and HYPACK ® Navigation driver in HYSCAN HARDWARE. HYPACKSURVEY SIDE SCAN SURVEY GPSSide Scan Sonar SHARED MEMORY POSITION, HEADING, TIDE,, DEPTH Your computer

Setting up a Sidescan Device In Hardware, add the driver to position your main vessel In Hardware, add the driver to position your main vessel GPS.DLL in this example. GPS.DLL in this example. Create a 2 mobile for your towfish position. Create a 2 mobile for your towfish position. Named ‘Sidescan’ in this example. Named ‘Sidescan’ in this example. Select a driver to position the towfish. Select a driver to position the towfish. Towfish.DLL in this example. Towfish.DLL in this example. Select Sidescan Survey in System (check Include box for Sidescan Survey) Select Sidescan Survey in System (check Include box for Sidescan Survey) Note : If you are towing a sidescan, you need to create the mobile in Hardware before selecting the sidescan option

Setting up a Sidescan Device Note : If you are using backscatter from a MB system or sidescan from an Interferometric MB system, use the set-up in HYSWEEP ® hardware. If you are towing a system, you MUST have a positioning device for the sidescan mobile. In Sidescan devices: In Sidescan devices: Select Sidescan from the list of sensors. Select Sidescan from the list of sensors. Check Specific Sonar Identification (for processing data in Geocoder) Check Specific Sonar Identification (for processing data in Geocoder) Check Setup. Some sidescan systems will have user options. If this option is greyed out, there is nothing to set. Check Setup. Some sidescan systems will have user options. If this option is greyed out, there is nothing to set.

Connect Side scan sonar: Most have network connections. Verify address and UDP port settings.

COM Test and Network Test Serial COM Test is not very useful for sonar testing. Most sonars use network connection. Use the Network Test to verify data communication. Allows to Ping device to test for connectivity and check for data stream.

Sensor Offsets Position offsets: Relative to boat or towfish origin. Usually “0.0” for a towed side scan. Rotation offsets: Set to 0. Not used for sidescan operations.

Interfacing Analog Sidescan : Analog to Digital card options The NI USB-6221 is a USB device which works in all Windows versions supported by HYPACK® The earlier card in use, the NI 6024E works in Windows XP (SP2) operating systems, but is not supported by the newer Operating Systems. Analog Sidescan Setup option for the different connector types

Connector Block Configuration: USB–6221 For Windows Vista, Windows 7 and Windows 8  Connection to computer is USB  Connections between side scan and USB-6221 is via coax cables: AI0 = Port signal AI1 = Starboard signal AI2 = Trigger Ensure you load all National Instrument libraries included on the A/D board install CD

Analog Software Setup Configuring the Software: Run the Sidescan Hardware program from HYPACK®. Add device “Analog Sidescan”. Select input device (NI 6024 or 6221) Run Sidescan Survey from HYPACK®. The Analog Sidescan monitor will start with Survey. Set the appropriate ranges for your sidescan.  voltage range  trigger polarity / threshold  I/O channel settings When finished with the Analog Sidescan Monitor, you may minimize it to get it out of the way, but do not close it. I/O channel set-up

Ready for Survey 1.For sidescan operations, select HYPACK Survey and Side Scan Survey. 2.If everything is working properly, you will see navigation (from the positioning system from HYPACK SURVEY) and Sidescan data from the sonar Do not use the Side Scan Survey option in the sidescan menu for data collection. This is used for playback of data files and testing of the sonar system only.