A new mobility analyzer for routine measurement of atmospheric aerosol in the diameter range of 0.4−7.5 nm Institute of Physics, University.

Slides:



Advertisements
Similar presentations
Microscale structure of air ion spatial and temporal distribution: some problems Hyytiälä
Advertisements

Drift velocity Adding polyatomic molecules (e.g. CH4 or CO2) to noble gases reduces electron instantaneous velocity; this cools electrons to a region where.
Aerosol Optical Properties via Cavity Ring-Down Technology Virtual Impactor for Sub-micron Aerosol Particles A. A. Boľshakov, A. W. Strawa, A. G. Hallar.
(Industrial Electronics) Engr. M. Laiq Ur Rahman
Chapter 4.2: Flow Across a Tube Bundle Heat Exchanger (Tube Bank)
Chapter 23 Gauss’ Law.
Remote sensing in meteorology
How long will the test last?
Uncertainty considerations for the calibration of transfer standard radiation thermometers Graham Machin, NPL.
Jennifer Tansey 12/15/11. Introduction / Background A common type of condenser used in steam plants is a horizontal, two- pass condenser Steam enters.
EXPERIMENTAL ERRORS AND DATA ANALYSIS
Instrumental Methods: Intro  Types of Instrumental Methods  Fundamental Components of an Instrument  Instruments Measure Voltages and Currents! (“Machines”
A Miniature Ion Mobility Spectrometer for Explosives Detection Andrew Goodin, William F. Siems, Christina L. Crawford, Prabha Dwivedi, and Herbert H. Hill,
October 28, 2008Final Work Presentation1. October 28, 2008Final Work Presentation2.
Air-Water Heat Exchanger Lab In this lab, YOU will design, conduct, and analyze your experiment. The lab handout will not tell you exactly what to measure.
University of South Carolina FCR Laboratory Dept. of Chemical Engineering By W. K. Lee, S. Shimpalee, J. Glandt and J. W. Van Zee Fuel Cell Research Laboratory.
1 Seventh Lecture Error Analysis Instrumentation and Product Testing.
Classification of Instruments :
Lesson 5 What devices do we use to measure radon?.
Chapter 6 Random Error The Nature of Random Errors
Errors and Uncertainties © Christopher Talbot and Cesar Reyes 2008
Capacitance and Dielectrics
Numerical methods in flow metrology Sampo Sillanpää, Centre for metrology and accreditation.
Direct Current And Resistance Electric Current The Battery Resistance And Ohm’s Law Power Internal Resistance Resistors In Combination RC Circuits Written.
Application of the Direct Optimized Probabilistic Calculation Martin Krejsa Department of Structural Mechanics Faculty of Civil Engineering VSB - Technical.
Metrology Adapted from Introduction to Metrology from the Madison Area Technical College, Biotechnology Project (Lisa Seidman)
Simulating of nucleation bursts in forest
Chem. 230 – 9/23 Lecture.
CHROMATOGRAPHY Chromatography basically involves the separation of mixtures due to differences in the distribution coefficient.
Sundermeyer MAR 550 Spring Laboratory in Oceanography: Data and Methods MAR550, Spring 2013 Miles A. Sundermeyer Observations vs. Models.
MS Calibration for Protein Profiles We need calibration for –Accurate mass value Mass error: (Measured Mass – Theoretical Mass) X 10 6 ppm Theoretical.
Handheld Flow Calibrator for Aerosol Observing System Jonathan Ma, Dung (Yung) Hoang Nguyen, Mario Zuniga Department of Mechanical and Aerospace Engineering,
Resolution of a DMA at atmospheric measurements Pühajärve 2010 (a simplified approach)
Laboratory of Environmental Physics Institute of Physics, University of Tartu Quiet nucleation of atmospheric aerosol and intermediate.
A proposal of ion and aerosol vertical gradient measurement (as an example of application of the heat transfer equations) H. Tammet Pühajärve 2008.
BSMA Filter step 3.5 sheet 0.5, gap Condenser width 260, HV electrode thickness 3.0 Collector size 32.4×170.6, gap 1.3 C0 R1.
Instrumental Methods: Intro
1 Objective Finish with PM measurements Discuss Friday’s filed measurements 1.
Chapter 8. FILTRATION PART II. Filtration variables, filtration mechanisms.
KL-parameterization of atmospheric aerosol size distribution University of Tartu, Institute of Physics Growth of nanometer particles.
Introduction to Chromatography. Introduction Chromatography permit the scientist to separate closely related components of complex mixtures. In all chromatographic.
FINESTION a complete dataset of routine air ion measurements 2003 – 2006 in co-operation with: Urmas Hõrrak, Kaupo Komsaare,
KL-parameterization of atmospheric aerosol size distribution University of Tartu, Institute of Physics with participation of Marko.
Estimating of neutral nanoparticles according to measurements of intermediate ions Hyytiälä Kaupo Komsaare & Urmas Hõrrak.
Project of integral ion counter Project of integral ion counter Hannes Tammet 25. veebruar a.
Four open datasets of atmospheric ion and aerosol measurements with acknowledgements to colleagues providing the data for open access.
Lecture 8: Measurement Errors 1. Objectives List some sources of measurement errors. Classify measurement errors into systematic and random errors. Study.
Ion-Induced Nucleation of Atmospheric Aerosols Peter H. McMurry, PI Kenjiro (Ken) Iida, Graduate Student Department of Mechanical Engineering University.
Experimental study of the “rain effect” on the mobility distribution of air ions. Experiments with water jet. U. Hõrrak, H. Tammet, E.Tamm, A. Mirme. Institute.
AGROFARM WEATHER MONITOR USING LabVIEW. INTRODUCTION Innovation in agriculture field Implementing instrumentation tech. in agricultural field The quantity.
Lecture 8 Peak Parameters and Quantitative chromatography
CHAPTER 5 DC AND AC BRIDGES.
Animating smoke with dynamic balance Jin-Kyung Hong Chang-Hun Kim 발표 윤종철.
OBSERVATION ON ION DYNAMICS Urmas Hõrrak, Hannes Tammet Institute of Environmental Physics, University of Tartu, 18 Ülikooli St., Tartu, Estonia.
Comments about integral parameters of atmospheric aerosol particle size distribution and two power law Comments about integral parameters of atmospheric.
Experimental study of the “rain effect” on the mobility distribution of air ions. Experiments with water jet. U. Hõrrak, H. Tammet, E.Tamm, A. Mirme.
Acknowledgements Slides and animations were made by Dr. Jon Karty Mass Spectrometry Facility Indiana University, Bloomington.
Kaupo Komsaare & Urmas Hõrrak
Hyytiälä Microscale structure of air ion spatial and temporal distribution: some problems Hyytiälä
I International workshop on electro-hydro-dynamics
OBSERVATION ON ION DYNAMICS
Air-Water Heat Exchanger Lab
PIV Investigation of EHD Flow Caused by Field-enhanced Dissociation
Introduction to Electrical Measurement
Electrophoresis: Movement of a solid phase with respect to a liquid (buffer) Sample is applied to the medium and under the effect of electric field, group.
UNIT 3 MEASUREMENT AND DATA PROCESSING
Laboratory in Oceanography: Data and Methods
8.7 Gated Integration instrument description
Remote sensing in meteorology
Presentation transcript:

A new mobility analyzer for routine measurement of atmospheric aerosol in the diameter range of 0.4−7.5 nm Institute of Physics, University of Tartu

The Symmetric Inclined Grid Mobility Analyzer SIGMA is arranged for study of initial stages of the atmospheric aerosol nucleation and it should: ► be good for long-term routine measurements in natural atmospheric conditions, ► measure size distribution of small air ions and charged nanometer particles up to diameter of 7–8 nm, ► detect size fractions with low concentration down to 1 cm −3, ► keep natural air temperature and humidity in the air tract during the measurement, ► minimize inlet distortions, which can be caused by the atmospheric electric field. INTRODUCTION

The methods of transversal fields and of longitudinal fields were introduced in the Cavendish Laboratory at the end of 19th century under supervision of J.J. Thomson. CLASSIC METHODS The method of transversal fields is popular until today but the method of longitudinal fields was forgotten because it does not allow entering of ions from the outside air. air flow E Figure from Tammet (1970) Ions are created between the grids E air flow Opposed migration by Zeleny (1898)

Loscertales (1998) showed that an intermediate configuration of fields allows to suppress the diffusion broadening of the transfer function. METHOD OF INCLINED FIELDS E air flow Problem: how to carry out inclined fields in an actual instrument?

Tammet, H. (1999) The limits of air ion mobility resolution. Proc. 11th Int. Conf. Atmos. Electr., NASA, Alabama, 626–629. INCLINED GRIDS Tammet, H. (2002) Inclined grid mobility analyzer: The plain model. Abstracts of Sixth International Aerosol Conference, 2, 647–648. Tammet, H. (2003) Method of inclined velocities in the air ion mobility analysis. Proc. 12th Int. Conf. Atmos. Electr., Versailles, 399–402.

Flagan, R.C. (2004) Opposed migration aerosol classifier (OMAC). Aerosol Sci. Technol. 38, 890 – 899. INCLINED POROUS ELECTRODES Electrodes are inclined relative to the velocity of air flow

COMPARISON IGMA: Tammet 1999 as rotated 71º OMAC: Flagan 2004 with added red arrows Grids are replaced by porous electrodes

Manufactured 2002 and published 2003 Previous experience: IGMA Sheath air Ballast air Inlet Electrometric collector Inlet Grids are made of perforated metal sheet

Removable external electrofilter Internal electrofilter Air inlet Inclined fields Electrometric collector IGMA Main unit

Traditional Erikson method, electrostatic induction is suppressed by a balanced Komarov bridge. First BSMA was manufactured 2003 and published 2004–2006. Long experience: routine measurements in Hyytiälä, Tartu, and Helsinki. Main advantage: the absolute calibration. Previous experience: BSMA

BSMA

Discussion in Hyytiälä 2007

► go back to the principle of IGMA, ► keep the mobility and size range as in approved instruments: 0.032–3.2 cm 2 V –1 s –1 & 0.4–7.5 nm, ► increase sensitivity, especially in range of 2–5 nm, ► improve time resolution, ► provide reliability in long term atmospheric measurements equal or better than of the BSMA. DECISIONS

SIGMA (manufactured 2009)

Jacobi-Seidel cell = 0.1 mm Analyzer Symmetr y plane Configuration of electrodes is optimized using a numerical model Width 90 mm, full length 360 mm Perforated sheet is replaced with a slat grid

Top view of topless SIGMA

CONTROL OF MEASUREMENT Performance of the SIGMA substantially depends on manipulating the instrument by the computer and processing of the recorded signals under the supervision of the control program. A 20-second scan begins with measuring of air temperature and pressure. Next the HV capacitor is quickly charged up to about 6000 V. Follows exponential decrease of voltage. The voltages of electrodes and electrometer outputs are measured about 100 times per second during a scan. Typically, every third scan is performed with closed air ion inlet gate and used for control of the zero level. Carefully insulated collector filters are powered with internal batteries.

Inlet loss is numerically compensated using the semiempiric equations of heat and mass transfer. Relative adsorption depends on temperature, pressure, and mobility as A = A o (T / T o ) 7/18 (p / p o ) 1/6 (Z / Z o ) 2/3. Calculation according to the parameters of SIGMA yields results for T o = 273 K, p o = 1013 mb and Z o = 1 cm 2 V –1 s –1 : Normal loss on inlet grid A grid = 1.1%, Normal loss on inlet gate A gate = 3.8%. The concentrations of mobility fraction are numerically corrected: f corrected = f uncorrected exp (A grid + A gate ). The relative uncertainty of the fraction concentrations induced by the uncertainty of the 5% correction is about 20 times less than the uncertainty of the estimate of the relative adsorption A. INLET LOSS

Mobility distributions presented by fraction concentrations, :00-24:00 SENSITIVITY 50%, 90% and 99% quantiles of fraction concentration absolute values at zero level of the real concentration.

TIME RESOLUTION WATER JET OPEN WATER JET CLOSED

The diffusionless geometric transfer function has a triangular shape and the relative standard deviation σ / Z = Brownian diffusion and smoothing by continuous scanning increases this parameter up to Additional components of broadening the transfer function (e.g. turbulence) cannot be estimated by theoretical calculations. Experimental result: during measurements a nearly Gaussian peak with σ / Z = 0.2 was recorded. Thus the mobility resolution was estimated as: 0.15 ≤ σ / Z ≤ ≤ Z / ΔZ 1/2 ≤ ≤ RFD ≤ 7 (RFD = Resolved Fractions per Decade) MOBILITY RESOLUTION

EXAMPLE 1 (5 min time resolution)

EXAMPLE 1a (excerpt from previous)

EXAMPLE 2 (1 min time resolution)

Some essential properties of the instrument are:  The positive and negative air ions are sampled from the same inlet air flow and measured exactly simultaneously.  The sheath air is sucked into the instrument from the atmosphere together with the analyzed air and ions pass during the analysis only the unaffected atmospheric air.  A high rate of air flow of about 30 dm 3 /s and the isopotential principle suppress the disturbing effect of the external electric field and assure representative sampling of air ions. CONCLUSIONS

 The loss of ions in the inlet tract is low and can be accurately corrected online.  A short residence time of about 0.16 s and low heating of air less than 0.5 K suppress the risk of changing of the ions during the measurement.  Standard control program records 16 fractions of atmospheric small and intermediate ions during every 5 minute cycle with random errors of about 1 cm −3.  Time resolution of 20 s is available at random errors in the mobility fraction concentrations of 4…10 cm −3. CONCLUSIONS (continued)