Reaction Monitoring with ReactionView ® and ReactionProbe™ In-situ contamination and surface analysis with SpotView and SpotView-SL © Remspec Corp. 2014.

Slides:



Advertisements
Similar presentations
Progress in water vapour spectroscopy at RAL Dr Robert McPheat CAVIAR Annual Meeting Imperial College, 16/12/2008.
Advertisements

Contents: Cover
Convection Temperature Device
E VERY L IFE H AS A P URPOSE… Chemgard TM Infrared Gas Monitor.
Thermal Analysis Differential Scanning Calorimetry (DSC) – Measure heat absorbed or liberated during heating or cooling Thermal Gravimetric Analysis (TGA)
Raman Spectroscopy A) Introduction IR Raman
The world leader in serving science Reflection Techniques.
InfraCal TOG/TPH Analyzers for Oil and Grease Measurements
Yu. I. BARANOV and W. J. LAFFERTY Optical Technology Division Optical Technology Division National Institute of Standards and Technology, Gaithersburg,
Inert Atmosphere Systems in OLED Research and Fabrication Copyright, 1996 © Dale Carnegie & Associates, Inc.
Bellow valve (trap&pump) Inside glove box. (Note: Ar glove box is not necessary, if you work with single crystalline organic materials like rubrene that.
The YL2000 FTIR.
Atomic Absorption Spectrometry Dr AKM Shafiqul Islam University Malaysia Perlis.
Drug Delivery & Tissue Engineering Laboratory
X-ray Astronomy Lee Yacobi Selected Topics in Astrophysics July 9.
High Efficiency Commercial Gas HCG Series. 2 American HCG Series The HCG Series High Efficiency Commercial Gas Water Heaters embody all that’s great about.
In carbon-13 NMR, what do the number of peaks represent?
Light Source: Globar Silicon Carbide Rod (5mm diameter, 50 mm long) Heated electrically to 1300 – 1500 K Positive temperature coefficient of resistance.
CAVIAR water vapour laboratory FTS measurements Dr Robert McPheat CAVIAR Meeting Cosners’ House, 15/12/2009.
Design of Health Technologies lecture 12 John Canny 10/17/05.
Water vapour spectroscopy in the MSF Dr Robert McPheat CAVIAR Progress Meeting NPL 02/06/2008.
Progress in water vapour spectroscopy at RAL Dr Robert McPheat CAVIAR Progress Meeting Cosners’ House, 14/12/2009.
Infrared Radiation 780 nm m Near, Mid and Far
1 VACUUM ATMOSPHERES Co NEW PRODUCT ANNOUNCEMENT November 28, 2001.
FT-IR Instrument. Components Source Michelson Interferometer Sample Detector.
Progress in water vapour spectroscopy at RAL Dr Robert McPheat CAVIAR Progress Meeting University of Leicester, 24/09/2009.
Applied Analytics, Inc. Yoav has been the R&D manager at AAI for the past 10 years. Extracurricular activity is flight instruction (see arrival to Chicago.
INTERIOR WALL FINISHES
Lecture 3 INFRARED SPECTROMETRY
EXPLORING PROPERTIES OF MATERIALS
Fourier transform infrared spectroscopy[FTIR]
NeSSI Compatible Spectroscopic Flow Cells
COMPANY PRESENTATION TO: MONTH XX, Agenda Who we are Our experience Benefits of measuring with light The Prozess Technologie solution Identify YOUR.
TEMPLATE DESIGN © v DIRECT DEMONSTRATION OF THE GREENHOUSE EFFECT Abstract Consider these three “theories:” climate change,
Chapter 6 - Chromatography
Gas Chromatography Carrier Gas Flow Control Injector Port Column Column Oven Detector Recorder The GC system consists of gas supplies for the mobile phase.
Advanced Spectroscopy 3. Infrared Spectroscopy. Revision 1.What molecular or structural features give rise to absorption of infrared (IR) radiation? covalent.
High Sensitivity Smoke Detection
Atomic Absorption Spectrometry
Practical Requirements for a Flow System. Introduction to practical requirements Key requirements for a Flow Chemistry System Introduction to important.
Designer and Manufacturer of Scientific Instruments Since 1985.
RNDr. Jaroslav Turánek, CSc.
Infrared Spectroscopy
Turbidity Measurement By Douglas Rittmann, Ph.D., P.E. Water/Wastewater Consultant To UTEP Laboratory Course On February 21, 2006.
Practical Applications of Raman Spectroscopy for Process Analysis
What tests are necessary to make sure your kegs are being cleaned, sanitized and filled correctly By Andrew J. Brewer
PF3W Series 3-Color Display Digital Flow Switch Planned release date: May 2012.
Beamline AILES : Mid IR to THz Spectroscopy The AILES Infrared and THz High Resolution Spectroscopy beamline at SOLEIL (Saclay, 30 km south of Paris) –
Created with MindGenius Business 2005® Instrumentation (1) Instrumentation (1) Origins Preparative column chromatography (Glass columns) Internal diameter:
Infrared Microspectroscopy
Miss : SALSABEEL H. AL JOUJOU
Centaurµs Centaurus Technical Review. Centaurµs Centaurus Standard Features Transmission Reflection A single aperture before the sample –Targeting Manual.
Process Control of Esterification in a NeSSI-Based Micro-Reactor by Raman Spectroscopy Stuart Farquharson, Chetan Shende, Frank Inscore, and Wayne Smith.
Reaction Monitoring with the ReactionView ® System Remspec Corporation © Remspec Corp
Spectroscopic Surface Analysis and Cleaning Verification with SpotView ® Systems.
Infrared Microspectroscopy A training guide for using light microscopy and infrared spectroscopy to analyze materials.
Using ReactionView® and ReactionProbe ™ : In-Situ Reaction Monitoring with FTIR Spectroscopy.
What Does Remspec Do? Remspec provides fiber-optic reaction monitoring solutions for R&D and process development. Remspec develops reaction-monitoring.
 FT-IR stands for Fourier Transform Infrared, the preferred method of infrared spectroscopy. In infrared spectroscopy, IR radiation is passed through.
Correction of FTIR data for the effect of temperature variation Peter J. Melling, Remspec Corporation, Charlton MA.
Linescanner MP150 Infrared Temperature Measurement for Quality Control and Process Automation Raytek Confidential 10/2010, Rev. B.
LAB. S4 Identification of Drugs Using Attenuated Total Reflectance Fourier Transform Infrared Spectroscopy (ATR-FT-IR Spectroscopy)
UV/VIS SPECTROSCOPY.
Mr. Nilesh Gaikar, Asst. Professor Department: School of Pharmacy
Chromatography- TLC & HPLC
Fourier Transformation Infra-red
Reaction Monitoring with the ReactionView® System
A Very Brief Introduction to Infrared Spectroscopy
Infrared Sampling Methods
GAS CHROMATOGRAPHY.
Presentation transcript:

Reaction Monitoring with ReactionView ® and ReactionProbe™ In-situ contamination and surface analysis with SpotView and SpotView-SL © Remspec Corp. 2014

Remspec Corporation Remspec has been manufacturing and selling mid-IR fiber optic systems since 1993 (over twenty years). We have sold hundreds of fiber-optic probes and systems to academic and industrial customers all over the world. We have more experience with mid-IR fiber optics than any other company and we make the fiber in-house. Our software is designed by synthetic chemists to be used by chemists and we can provide fully customized software. Our experienced scientific staff provides full support for applications development, including calibration development. © Remspec Corp. 2014

ReactionView® Range cm -1 ATR and transmission heads fit wide range of reactors Full control and display software on a laptop 20 hr detector dewar for overnight experiments © Remspec Corp. 2014

ReactionProbe ™ Remspec's probes can be used with most commercial FTIR units. The signal is taken from the sample compartment to the probe, and returned from the MCT detector to the spectometer. All of the interchangeable heads are available with the ReactionProbe. © Remspec Corp. 2014

Modular Systems Remspec systems are fully modular: Analysis heads for high or low temperature, high pressure, corrosive solvents. Replaceable ATR crystals for standard conditions, high and low pH, corrosive conditions. Liquid transmission head for very low concentrations Short-path gas transmission cell. Only the head is changed for changing conditions or different types of reactor port. ATR and transmission crystals are replaceable and Remspec offers low-cost rebuilding of fiber-optic probes for low total cost of ownership. © Remspec Corp. 2014

ATR Head A range of materials can be used (ZnSe is shown) Good, general-purpose probe Sensitive down to about 0.1 wt.% of most analytes Works in all solvents, including water Stainless steel* probe, shaft Kalrez® seals, and inert crystal materials make the probe corrosion-resistant. The room-temperature head is shown. *Hastelloy is available for extreme conditions © Remspec Corp. 2014

Transmission Head The Liquid Transmission Head lowers the detection limit to <0.1mM. It is a double-pass transmission cell with a mirror wall. It can only be used in solvents that have low mid- IR absorbance (e.g. hexane,acetonitrile, methylene chloride, THF); suspended solids can interfere with performance. © Remspec Corp. 2014

Analysis Heads: High Temperatures High Temperature Head Gas cooled (air or nitrogen) ATR or Transmission -100ºC to >200ºC 15mm OD Available with chemically resistant polymer end for low heat transfer © Remspec Corp. 2014

In-Situ Spectroscopy at High Pressures High Pressure Head (example) Custom seal (cone in cone fitting shown) ATR or Transmission Pressure to 200 bar Cooled (air or nitrogen), -100ºC to >200ºC (standard) Water and gas cooled -100 ° C to 300 ° C (special order) © Remspec Corp. 2014

VizIR™ Software Available with ReactionView Can collect a single dataset for 3.5 days at one spectrum per minute (5000 spectra) VizIR includes a Control Panel for setting the resolution and timing of data collection during an experiment, as well as Start and Stop buttons. The display windows show a 3D picture of the spectra versus time, and a window for most recent spectra or trend-lines. PCA/ITTR analysis with ReactionSleuth ™ © Remspec Corp. 2014

Example: 2-step Organic Synthesis 2-step commercial synthesis reaction Step 1 Anion formation Step 2 Product formation Solvent is DMF Note solvent peak at approx cm -1. © Remspec Corp. 2014

Reaction Monitoring in Summary Remspec manufactures and supplies mature, well supported systems with a wide choice of sampling options that are easy to use and provide repeatable data. Remspec provides specialized software that is optimized specifically for reaction monitoring and the analysis of reaction data. © Remspec Corp. 2014

Grazing Angle FTIR Spectroscopy © Remspec Corp. 2014

SpotView Head Hand-held grazing angle unit Sensitive to <1 μg/cm 2 Suitable for large flat and curved surfaces Works on metal, glass, and most plastics © Remspec Corp. 2014

SpotView Case Study: inside stainless steel production tanks Tank interior (agitator shaft of CIP system). Note: spectral features in top trace, eventually identified as residue from cleaning material, traced back to pump used in cleaning cycle. Baseline shift, characteristic of contaminated surface © Remspec Corp. 2014

SpotView-SL Head © Remspec Corp Hand-held direct reflectance unit Sensitive to ~3 μg/cm 2 Suitable for small curved or low-access surfaces Works on metal, glass, and most plastics

SpotView-SL Case Study: polymer residue on steel extrusion screw Upper trace: 3.5 μg/cm 2 Lower trace: 6.0 μg/cm 2 C-H stretch feature is integrated. A PLS1 calibration can also be built. Integration: 0.19 Integration: 0.30 © Remspec Corp. 2014

Surface Analysis in Summary Remspec manufactures and supplies both grazing- angle and direct reflectance heads for flat and curved, large and small surfaces. Remspec provides: specialized software that can be set up for “push-button” use by the operator. Calibration development and support services. © Remspec Corp. 2014