Lecture 3: The Bloch Equations Solved & the MR Signal Equation Solve the Bloch equation –Precession –T2 relaxation –T1 relaxation MR signal equation –Understand.

Slides:



Advertisements
Similar presentations
Fund BioImag : Echo formation and spatial encoding 1.What makes the magnetic resonance signal spatially dependent ? 2.How is the position of.
Advertisements

Fund BioImag : Echo formation and spatial encoding 1.What makes the magnetic resonance signal spatially dependent ? 2.How is the position of.
Computer Vision Lecture 7: The Fourier Transform
Ari Borthakur, PhD Associate Director, Center for Magnetic Resonance & Optical Imaging Department of Radiology Perelman school of Medicine, University.
Principles of the MRI Signal Contrast Mechanisms MR Image Formation John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University.
BE 581 Lecture 3- Intro to MRI.
PHYSICS OF MAGNETIC RESONANCE
Lecture 7: Basis Functions & Fourier Series
Parameters and Trade-offs
Principles of MRI: Image Formation
Chapter 9 Basic MRI I Mark D. Herbst, MD, PhD. Notice This lecture contained many drawings on the whiteboard, so get these from one of the other students.
Magnetic Resonance Imaging
Signal Spaces.
Machine Transformations
Terry M. Button, Ph.D. Principals of Magnetic Resonance Image Formation.
ELEG 479 Lecture #9 Magnetic Resonance (MR) Imaging
Multiple Coherence Pathways. Simple spin echo TETE TETE abc d spin echo 90 y 180 x.
Noise. Noise is like a weed. Just as a weed is a plant where you do not wish it to be, noise is a signal where you do not wish it to be. The noise signal.
Nuclear Magnetic Resonance (NMR) Magnetic Resonance Imaging (MRI)
Basics of Magnetic Resonance Imaging
FMRI: Biological Basis and Experiment Design Lecture 7: Gradients and k-space FFT examples –Sampling and aliasing Gradient Gradient echo K-space
1 Sinusoidal Functions, Complex Numbers, and Phasors Discussion D14.2 Sections 4-2, 4-3 Appendix A.
Resonance condition. Pulse A coil of wire placed around the X axis will provide a magnetic field along the X axis when a direct current is passed through.
Lecture 4 MR: 2D Projection Reconstruction, 2D FT Longitudinal Magnetization returns to equilibrium as MR Review Transverse Magnetization Gradients’ effect.
Radiofrequency Pulse Shapes and Functions
Medical Imaging Systems: MRI Image Formation
Magnetic Resonance Imaging 4
Principles of MRI Physics and Engineering
ELEC ENG 4035 Communications IV1 School of Electrical & Electronic Engineering 1 Section 2: Frequency Domain Analysis Contents 2.1 Fourier Series 2.2 Fourier.
ELEG 479 Lecture #12 Magnetic Resonance (MR) Imaging
Prof. Brian L. Evans Dept. of Electrical and Computer Engineering The University of Texas at Austin EE345S Real-Time Digital Signal Processing Lab Spring.
Medical Imaging Systems: MRI Image Formation
Prof. Brian L. Evans Dept. of Electrical and Computer Engineering The University of Texas at Austin EE445S Real-Time Digital Signal Processing Lab Fall.
1 I. Phasors (complex envelope) representation for sinusoidal signal narrow band signal II. Complex Representation of Linear Modulated Signals & Bandpass.
Basic Concept of MRI Chun Yuan. Magnetic Moment Magnetic dipole and magnetic moment Nuclei with an odd number of protons or neutrons have a net magnetic.
Basic of Magnetic Resonance Imaging Seong-Gi Kim Paul C. Lauterbur Chair in Imaging Research Professor of Radiology, Neurobiology and Bioengineering University.
G Practical MRI 1 – 29 th January 2015 G Practical MRI 1 Introduction to the course Mathematical fundamentals.
Allen W. Song, PhD Brain Imaging and Analysis Center Duke University MRI: Image Formation.
A NMR pulse is often designed to detect a certain outcome (state) but often unwanted states are present. Thus, we need to device ways to select desired.
October 29, 2013Computer Vision Lecture 13: Fourier Transform II 1 The Fourier Transform In the previous lecture, we discussed the Hough transform. There.
Chapter 2 Laplace Transform 2.1 Introduction The Laplace transform method can be used for solving linear differential equations. Laplace transforms can.
Eeng Chapter4 Bandpass Signalling  Definitions  Complex Envelope Representation  Representation of Modulated Signals  Spectrum of Bandpass Signals.
MECHATRONICS Lecture 07 Slovak University of Technology Faculty of Material Science and Technology in Trnava.
FMRI – Week 4 – Contrast Scott Huettel, Duke University MR Contrast FMRI Graduate Course (NBIO 381, PSY 362) Dr. Scott Huettel, Course Director.
MRI. Vector Review x y z Vector Review (2) The Dot Product The Cross Product (a scalar) (a vector) (a scalar)
BME1450 Intro to MRI February 2002 The Basics The Details – Physics The Details – Imaging.
Frequency Modulation ECE 4710: Lecture #21 Overview:
Lecture 3: The MR Signal Equation We have solved the Bloch equation and examined –Precession –T2 relaxation –T1 relaxation MR signal equation –Understand.
V.G.Wimalasena Principal School of Radiography
Geology 5640/6640 Introduction to Seismology 2 Feb 2015 © A.R. Lowry 2015 Read for Wed 4 Feb: S&W (§2.4); Last time: The Wave Equation! The.
Fourier Transform.
MR Image Formation FMRI Graduate Course (NBIO 381, PSY 362)
MRI Physics: Spatial Encoding Anna Beaumont FRCR Part I Physics.
 Introduction to reciprocal space
Magnetic Resonance Learning Objectives
Charged particle. Moving charge = current Associated magnetic field - B.
Principles of MRI Physics and Engineering Allen W. Song Brain Imaging and Analysis Center Duke University.
Lecture 1: Magnetic Resonance
1 Nuclear Magnetic Resonance ANIMATED ILLUSTRATIONS MS Powerpoint Presentation Files Uses Animation Schemes as available in MS XP or MS 2003 versions A.
Lecture 4 - E. Wilson –- Slide 1 Lecture 4 - Transverse Optics II ACCELERATOR PHYSICS MT 2009 E. J. N. Wilson.
MRI Physics in a Nutshell Christian Schwarzbauer
Magnetic Resonance Imaging: Physical Principles
Spatial Encoding: Sub mm from meter sized RF
An Optimal Design Method for MRI Teardrop Gradient Waveforms
MRI Pulse Sequences: IR, EPI, PC, 2D and 3D
How MRI Works By Wesley Eastridge, adapted from and with illustrations from The Basics of MRI by Joseph P. Hornak, Ph.D.
Introduction to MR Robert Frost
A recent history 1946 Felix Bloch and Edward Purcell independently discover the magnetic resonance phenomena (Nobel Prize in 1952) 1971 Raymond Damadian:
(4)ELECTRONIC SUPPORT SYSTEM
Introduction to MR Robert Frost
Presentation transcript:

Lecture 3: The Bloch Equations Solved & the MR Signal Equation Solve the Bloch equation –Precession –T2 relaxation –T1 relaxation MR signal equation –Understand how magnetization changes phase due to gradients –Understand MR image formation or MR spatial encoding

Bloch Equations – Homogenous Material It’s important to visualize the components of the vector M at different times in the sequence. a)Let us solve the Bloch equation for some interesting cases. In the first case, let’s use an arbitrary M vector, a homogenous material, and consider only the static magnetic field. b)Ignoring T1 and T2 relaxation, consider the following case. Solve

The Solved Bloch Equations Solve

The Solved Bloch Equations A solution to the series of differential equations is: Next we allow relaxation. where M 0 refers to the initial conditions. M0 refers to the equilibrium magnetizataion. This solution shows that the vector M will precess about the B0 field.

Solution: Longitudinal Magnetization Component The greater the difference from equilibrium, the faster the change Solution: Initial Mz Return to Equilibrium

Solution: Longitudinal Magnetization Component initial conditions equilibrium Example: What happens with a 180° RF flip? t MoMo -M o Effect of T 1 on relaxation - 180° flip angle

Complex m m is complex. m =M x +iM y Re{m} =M x Im{m}=M y This notation is convenient: It allows us to represent a two element vector as a scalar. Re Im m MxMx MyMy

Transverse Magnetization Component The transverse magnetization relaxes in the Bloch equation according to This is a decaying sinusoid. t We continue to study the transverse magnetization. Why? Transverse magnetization gives rise to the signal we “readout”. Solution to this equation is :

Inhomogeneous Object - Nonuniform field. Now we get much more general. Before, M(t) was constant in space and so no spatial variable was needed to describe it. Now, we let it vary spatially. We also let the z component of the B field vary in space. This variation gives us a new phase term, or perhaps a more general one than we have seen before.

Transverse Magnetization Equation We can number the terms above variation in proton density 2. - spatial variation due to T rotating frame frequency - “carrier” frequency of signal 4. - spins will precess at differential frequency according to the gradient they experience (“see”).

Transverse Magnetization Equation Phase is the integral of frequency. - spins will precess at differential frequency according to the gradient they “see”. Thus, gradient fields allow us to change the frequency and thus the phase of the signal as a function of its spatial location. Let’s study this general situation under several cases, from the specific to the general.

The Static Gradient Field In a static (non-time-varying) gradient field, for example in x, Plugging into solution (from 2 slides ago) and simplifying yields

The Static Gradient Field Now, let the gradient field have an arbitrary direction. But the gradient strength won’t vary with time. Using dot notation, Takes into account the effects of both the static magnetic and gradient fields on the magnetization gives

Time –Varying Gradient Solution (Non-static). We can make the previous expression more general by allowing the gradients to change in time. If we do, the integral of the gradient over time comes back into the above equation.

Receiving the signal Let’s assume we now use a receiver coil to “read” the transverse magnetization signal We will use a coil that has a flat sensitivity pattern in space. Is this a good assumption? - Yes, it is a good assumption, particularly for the head and body coils. Then the signal we receive is an integration of over the three spatial dimensions.

Receiving the signal (2) 3) Demodulate to baseband. i.e. zozo slice thickness  z Let’s simplify this: 1) Ignore T 2 for now; it will be easy to add later. 2) Assume 2D imaging. (Again, it will be easy to expand to 3 later.) S(t) is complex.

Receiving the signal (3) 3) Demodulate to baseband. i.e. S(t) is complex. Then, end goal

G x (t) and G y (t) Now consider G x (t) and G y (t) only. Deja vu strikes, but we push on! Let

k x and k y related to t Let As we move along in time (t) in the signal, we simply change where we are in k x, k y (dramatic pause as students inch to edge of seats...)

k x and k y related to t (2) x,y are in cm, k x,k y are in cycles/cm or cycles/mm kx,kx,k y are reciprocal variables.xy Remarks: 1) S(t), our signal, are values of M along a trajectory in F.T. space. - (called k-space in MR literature) 2) Integral of G x (t), G y (t), controls the k-space trajectory. 3) To image m(x,y), acquire set of S(t) to cover k-space and apply inverse Fourier Transform.

Spatial Encoding Summary Consider phase. Receiver detects signal What is ? Frequencyis time rate of change of phase. So

Spatial Encoding Summary So But Expanding, We control frequency with gradients. So,

Complex Demodulation The signal is complex. How do we realize this? In ultrasound, like A.M. radio, we use envelope detection, which is phase-insensitive. In MR, phase is crucial to detecting position. Thus the signal is complex. We must receive a complex signal. How do we do this when voltage is a real signal?

Complex Demodulation s r (t) is a complex signal, but our receiver voltage can only read a single voltage at a time. s r (t) is a useful concept, but in the real world, we can only read a real signal. How do we read off the real and imaginary components of the signal, s r (t)? Or the in-phase and quadrature components? Complex receiver signal ( mathematical concept) The quantity s(t) or another representation, is what we are after. We can write s(t) as an inphase and quadrature component, I(t) and Q(t)

Complex Demodulation An A/D converter reading the coil signal would read the real portion of s r (t), the physical signal s p (t)

Complex Demodulation s p (t) X X cos(   t) Inphase: I(t) Quadrature: Q(t) sin(   t) Low Pass Filter Let’s next look at the signal right after the multipliers. We can consider the modulation theorem or trig identities.

Complex Demodulation s p (t) X X cos(   t) Inphase: I(t) Quadrature: Q(t) sin(   t) Low Pass Filter

Complex Demodulation s p (t) X X cos(   t) Inphase: I(t) Quadrature: Q(t) sin(   t) Low Pass Filter

Complex Demodulation The low pass filters have an impulse response that removes the frequency component at 2   We can also consider them to have gain to compensate for the factor ½.