Simulating the position sensitivity of the iThemba LABS segmented clover detector S. P. Noncolela 1, 2, T. D. Bucher 1, E. A. Lawrie 1, O. Shirinda 1,

Slides:



Advertisements
Similar presentations
Computer Simulation for Emission Tomography: Geant4 and GATE Xiao Han Aug
Advertisements

Detector Characterisation Group
Advanced GAmma Tracking Array
Ion beam Analysis Joele Mira from UWC and iThemba LABS Tinyiko Maluleke from US Supervisor: Dr. Alexander Kobzev Dr. Alexander Kobzev.
GRAPE(Gamma-Ray detector Array with Position and Energy sensitivity) Developed at CNS for in-beam  -ray spectroscopy with High Resolution M.
SmartPET: A Small Animal PET Demonstrator using HyperPure germanium Planar Detectors R. Cooper 1 st year PhD Student
Energy Postgraduate Conference EPC2013, Aug 2013 iThemba LABS SAHPA ® South African Heat Pipe Association Inlet and Outlet Shape-Optimization of.
High granularity to reduce the effect of the “prompt flash” radiation Polarization sensitivity Imaging capabilities for background suppression DESPEC (DEcay.
The AGATA project concept of  - ray tracking design and development Witek Męczyński The Henryk Niewodniczański Institute of Nuclear Physics Polish Academy.
Compton Camera David Scraggs. Code Aims Use two detectors in Compton scattering experiment Define cones from Compton interactions; cone surfaces define.
Pair backgrounds for different crossing angles Machine-Detector Interface at the ILC SLAC 6th January 2005 Karsten Büßer.
Kirov A S, MSKCC Overview of Geant4 Use and Issues in Imaging: Emission Tomography (PET and SPECT) Assen S. Kirov Department of Medical Physics Memorial.
Simulations with MEGAlib Jau-Shian Liang Department of Physics, NTHU / SSL, UCB 2007/05/15.
XXXII RTFNB - Lindoia, 2009 Digital Pulse Processing: A new paradigm in nuclear instrumentation Roberto V. Ribas – DFN-IFUSP.
Compton Scattering Reporter: Hui He. Outline Theory Experimental setup Experimental results (1) Calibration (2) Angular Distribution of the 137 Cs Source.
News from the GRETINA TRACKING group New in tracking: We can track Geant4 (G4) simulated data Using both the (1) original AGATA code simulations (with.
Depletion Region Dynamics of an AGATA Detector Steven Moon University of Liverpool UNTF 2010, University of Salford 14 th -16 nd April 2010.
IN A SEARCH FOR TETRAHEDRAL SYMMETRIES IN 156Dy S.N.T Majola†$, J F Sharpey-Schafer#*, R A Bark$, P Datta$, S P Bvumbi#, E A Georgieva Lawrie$, P Jones$,
Workshop on Physics on Nuclei at Extremes, Tokyo Institute of Technology, Institute for Nuclear Research and Nuclear Energy Bulgarian Academy.
Wednesday, May 9 th 2007Torsten Beck Fast Pulse Shape Analysis for AGATA-Germanium- Detectors Torsten BeckWednesday, 9. Mai 2007 Student seminar Wednesday,
St. Petersburg State University. Department of Physics. Division of Computational Physics. COMPUTER SIMULATION OF CURRENT PRODUCED BY PULSE OF HARD RADIATION.
Compton Camera development for the imaging of high energy gamma rays 1 Martin Jones UNTF 2010 Salford – April 14 th Martin.
Preliminarily results of Monte Carlo study of neutron beam production at iThemba LABS University of the western cape and iThemba LABS Energy Postgraduate.
PERFORMANCE OF THE MACRO LIMITED STREAMER TUBES IN DRIFT MODE FOR MEASUREMENTS OF MUON ENERGY - Use of the MACRO limited streamer tubes in drift mode -Use.
Monte Carlo Study to determine the Neutron Fluence spectrum for a water Phantom: Preliminary Results University of the Western Cape Energy Postgraduate.
Temperature Dependence of the Crystal Properties of 18-fold Segmented HPGe Detector Allen Caldwell, Daniel Lenz, Jing Liu, Xiang Liu, Bela Majorovits,
Developments in gamma spectrometry Alexandria University, Faculty of Engineering Nuclear Engineering Department JINR, Frank Laboratory of Neutron Physics.
Wolfram KORTEN, JRA-02 AGATAEURONS PCC-Meeting, Mainz (Germany), April 2006 Status of the AGATA project Recent developments Milestones and deliverables.
Search for two-phonon octupole excitations in 146 Gd Energy Postgraduate Conference 2013 University of Zululand/ University of the Western Cape Nontobeko.
BeamCal Simulations with Mokka Madalina Stanescu-Bellu West University Timisoara, Romania Desy, Zeuthen 30 Jun 2009 – FCAL Meeting.
Geomagnetic Spectroscopy: An Estimation of Primary Mass of Cosmic Rays Rajat K Dey 1,2 Arunava Bhadra 2 Jean-No ë l Capdevielle 3 1 Department of Physics.
SAHPA ® South African Heat Pipe Association Energy Postgraduate Conference EPC2013, Aug 2013 iThemba LABS EPC Investigating Instabilities.
We report the result of a beam test on a prototype of Astronomical hard X-ray/soft gamma-ray Polarimeter, PoGO (Polarized Gamma-ray Observer). PoGO is.
1,2 Tshepo Dinoko, 3 Vasilij Andrianov, 3 Pavel Sedyshev 1 iThemba LABS, Somerset West 7129, South Africa 2 University of the Western Cape, Bellville 7535,
On the origin of Differential Crosstalk in segmented detectors B. Bruyneel for the AGATA week, Uppsala, Sweden July 2008.
Simulation of the energy response of  rays in CsI crystal arrays Thomas ZERGUERRAS EXL-R3B Collaboration Meeting, Orsay (France), 02/02/ /03/2006.
NESTOR SIMULATION TOOLS AND METHODS Antonis Leisos Hellenic Open University Vlvnt Workhop.
DESPEC A Algora IFIC (Valencia) for the Ge array working group.
Development of a Segmented Planar Germanium Imaging Detector
PIXEL Slow Simulation Xin Li 3/16/2008. CMOS Active Pixel Sensor (APS) Epitaxy is a kind of interface between a thin film and a substrate. The term epitaxy.
Plans for a Simulation Study of the Magnetic Field Requirements of the LC TPC February 2006, ILC TPC Analysis Jamboree, DESY Christian Hansen University.
SAHPA ® South African Heat Pipe Association Energy Postgraduate Conference EPC2013, Aug 2013 iThemba LABS DH Jeggels and RT Dobson Department of.
Timing in Thick Silicon Detectors Andrej Studen, University of Michigan, CIMA collaboration.
Compton imaging with the PorGamRays Detector D S Judson Imaging 2010, Stockholm, 8 th -11 th June 2010.
1 LTR 2004 Sudbury, December 2004 Helenia Menghetti, Marco Selvi Bologna University and INFN Large Volume Detector The Large Volume Detector (LVD)
Systematic limitations to luminosity determination in the LumiCal acceptance from beam-beam effects C. Rimbault, LAL Orsay LCWS06, Bangalore, 9-13 March.
Validation of Geant4 EM physics for gamma rays against the SANDIA, EPDL97 and NIST databases Zhang Qiwei INFN-LNS/CIAE 14th Geant4 Users and Collaboration.
PSA: ADAPTIVE GRID SEARCH The Method Experimental Results Optimization aspects Roberto Venturelli (INFN Padova - IPSIA “Giorgi” Verona) SACLAY, 05-may-06.
Steven Moon, A.J. Boston, H. Boston, J. Cresswell, L. Harkness, D. Judson, P.J. Nolan PSD9, Aberystwyth, Wales th September 2011 Compton imaging.
Institute of Basic Science Rare Isotope Science Project PANGEA P hoton detector system for A stro-science and N uclear physics with GE rmanium A rray 2015.
Alex Howard, CERN Slide 1 Simulating Dark Matter Detectors (a.k.a. DMX Underground Advanced Example) 1.Dark Matter detectors 2.Implementation within Geant4.
Time Calibration System for RF Cavity Breakdown Measurements Juan Takase Northwestern University SIST INTERN Fermi National Lab 08/04/2015.
Geant4 Simulation for KM3 Georgios Stavropoulos NESTOR Institute WP2 meeting, Paris December 2008.
SIMULATION OF BACKGROUND REDUCTION TECHNIQUES FOR Ge DBD DETECTORS Héctor Gómez Maluenda. University of Zaragoza. GERDA/Majorana MC Meeting.
Hybrid Detector(s) for Complete Gamma Ray Spectroscopy S. S. Bhattacharjee, R Raut, S S Ghugre, A K Sinha UGC-DAE Consortium For Scientific Research, Kolkata.
Advanced Gamma Tracking Array Andy Boston The Advanced Gamma Tracking Array
Exploring the spectroscopy of vibrational levels in the transitional rare earth region University of Cape Town / iThemba LABS Siyabonga Majola Energy Postgraduate.
gamma ray polarisation measurement
L. Pandola INFN, Gran Sasso National Laboratories
Overview of GERDA simulation activities with MaGe
AGATA Advanced Gamma Tracking Array
Efficiency versus energy resolution
Pre-Test-stands at MPI Munich
HARPO, a Micromegas+GEM TPC for gamma polarimetry above 1 MeV
Monte Carlo studies of the configuration of the charge identifier
SIGMA: a detector for γ-ray spectroscopy & imaging Dr Laura AGATA/GRETINA Collaboration Meeting
Preliminary Compton Imaging results of the AGATA C001 detector
On the origin of Differential Crosstalk in segmented detectors
AGATA week Uppsala, July 2008
Efficiency versus energy resolution
Presentation transcript:

Simulating the position sensitivity of the iThemba LABS segmented clover detector S. P. Noncolela 1, 2, T. D. Bucher 1, E. A. Lawrie 1, O. Shirinda 1, J. L. Easton 1, 2, P. Medina 3 N.J. Orce 2 1. iThemba LABS, P. O. Box 722, 7129, Somerset West, South Africa. 2. University of Western Cape, Private Bag X17,7535, Bellville, South Africa 3. Laboratoire Aerologie, Universite Paul Sabatier, INSU, Toulouse Energy Postgraduate Conference 2013

Aim of the project To determine the position sensitivity of our detector using the shape of the core and segments pulses. Pulse shape analysis method compares the shape of a set of measured pulses with a corresponding set of pulses from a simulated reference database. To evaluate the gamma-ray tracking capability of the iThemba LABS segmented clover detector. To develop expertise in iThemba LABS on gamma spectroscopy using advanced gamma-ray tracking detectors.

iThemba LABS segmented clover detector

Description of MGS code

Simulation outputs

Core and segment pulses at different radii Core Hit segment

Core and segment pulses at different angles Core Segments, 35⁰ Segments, 55⁰ Segments, 70⁰

Core pulses at different depths Core

Conclusions and Future plans Pulse shapes have been simulated at different positions (radii, azimuthal angle and depth) within the detector volume. –For interaction points at different radii – the shape of the pulses at the inner contact can be used to resolve the positions. –For different azimuthal angles- the induced signal at the neighbouring segments are important in determining the position. –For different depths- there are positions for which the depth can be determined, but the detector seem to be less sensitive to some parts of the detector especially for interactions at the back of the detector.  Realistic simulations: pulse + preamp + electronics + cross talk  Build database of simulated pulses  Compare with experimental pulses  Simulating more than one interaction o Compton scattering between 2 segments o Compton scattering inside one segment

Thank You…