- page 1 July 22 2011 NHSC Mini-workshop PACS NASA Herschel Science Center PACS Spectrometer AORs Phil Appleton 1Roberta Paladini.

Slides:



Advertisements
Similar presentations
Echelle Spectroscopy Dr Ray Stathakis, AAO. What is it? n Echelle spectroscopy is used to observe single objects at high spectral detail. n The spectrum.
Advertisements

PACS SVR 38/9 Nov 2007 Wavelength Calibration1 FM ILT Spectrometer Wavelength Calibration Status Report H. Feuchtgruber, R. Vavrek.
HAWCPol / SuperHAWC Software & Operations J. Dotson July 28, 2007.
- page 1 July NHSC Mini-workshop PACS NASA Herschel Science Center PACS Photometer AORs How to Prepare an Observation with HSpot: 2 Science Use.
STATUS REPORT OF FPC SPICA Task Force Meeting March 29, 2010 MATSUMOTO, Toshio (SNU)
14 October Observational Astronomy SPECTROSCOPY and spectrometers Kitchin, pp
PACS Page 1 NHSC Data Processing Workshop – Pasadena Sept 10-14, 2012 SPIRE Spectrometer Data Reduction: Mapping Observations Nanyao Lu NHSC/IPAC (On behalf.
PACS FM-ILT SPECTROMETER SPATIAL CALIBRATION A. Contursi (H. Feuchtgruber) PACS Science Verification Review – 8/9 November 2007 MPE-Garching.
18 October Observational Astronomy SPECTROSCOPY and spectrometers Kitchin, pp
FM-ILT Results: Mechanisms FM1 Chopper and Calibration Sources Markus Nielbock (MPIA) Babar Ali (IPAC) Jeroen Bouwman (MPIA) Helmut Dannerbauer (MPIA)
Page 1 PACS NHSC Data Processing Workshop – Pasadena 26 th - 30 th Aug 2013 Overview of SPIRE Photometer Pipeline Kevin Xu NHSC/IPAC on behalf of the SPIRE.
PACS Hitchhiker’s Guide to Herschel Archive Workshop – Pasadena 6 th - 10 th Oct 2014 The SPIRE Photometer and its Observing Modes Bernhard Schulz (NHSC/IPAC)
PACS NHSC Data Processing Workshop – Pasadena 10 th - 14 th Sep 2012 SPIRE AOTs, Products and Quick Look Tools Bernhard Schulz NHSC/IPAC on behalf of the.
PACS Spectrometer Spatial Calibration plan in PV phase A.Contursi D. Lutz and U. Klaas.
PACS Hitchhiker’s Guide to Herschel Archive Workshop – Pasadena 6 th - 10 th Oct 2014 The PACS Photometer: Overview and Products Roberta Paladini NHSC/IPAC.
1 NHSC PACS NHSC/PACS Web Tutorials Running PACS photometer pipelines PACS-402 (for Hipe 12.0) Level 1 to Level 2 processing: The JScanam pipeline Prepared.
NHSC PACS NHSC Herschel Data Processing Workshop Steve Lord August Intro to HIPE PACS Spectroscopy: Getting Fluxes and Maps.
NASA Herschel Science Center - page 1 NHSC Cycle 1 Open Time Proposal Planning Workshop 3-4 June 2010 PACS Accepted Programs & Observations to Date B.
Spectroscopy with PACS M82 PACS line imaging from the SHINING team (Contursi et al First Results workshop talk) Phil Appleton and Dario Fadda for.
PACS SVR 22/23 June 2006 Scientific/Performance Requirements1 PACS Science and Performance Requirements A. Poglitsch.
MIRI Dither Patterns Christine H Chen. Dithering Goals 1.Mitigate the effect of bad pixels 2.Obtain sub-pixel sampling 3.Self-calibrate data if changing.
PACS Page 1 NHSC Workshop on HSA Data Oct 6-10, 2014 SPIRE Spectrometer Data Reduction: Special Cases Nanyao Lu NHSC/IPAC (On behalf of the SPIRE ICC,
PACS SVR 2 18 Jan 2007 FM ILT: Spectrometer1 Spectrometer Performance H. Feuchtgruber, T. Müller, A. Poglitsch.
PACS Hitchhiker’s Guide to Herschel Archive Workshop – Pasadena 6 th - 10 th Oct 2014 The PACS Spectrometer: Overview and Products Roberta Paladini NHSC/IPAC.
PVPhotFlux PACS Photometer photometric calibration MPIA PACS Commissioning and PV Phase Plan Review 21 st – 22 nd January 2009, MPE Garching Markus Nielbock.
Multiobject Spectroscopy: Preparing and performing Michael Balogh University of Durham.
Jan 21/22, 2009PACS PV Review Photometer Spatial Cal1 PACS Photometer Spatial Calibration PVPhotSpatial D.Lutz PACS PV Review Jan 21/ , MPE.
NHSC SPIRE Data School – Pasadena 28 th - 30 th June 2010 PACS page 1 SPIRE Imaging Fourier Transform Spectrometer (FTS) Pipeline Data Processing Nanyao.
MOS Data Reduction Michael Balogh University of Durham.
NHSC Cycle 1 Open Time Proposal Planning Workshop 3-4 June 2010 NASA Herschel Science Center - page 1 PAC S prepared by Nicolas BILLOT
Overview, Spectrometer Products and Processing Philosophy Phil Appleton on Behalf of PACS Team PACS IFU Spectrometer.
APT Overview for Transiting Exoplanet Proposals Chris Moriarty – APT Developer.
Emission Line Surveys Lecture 1 Mauro Giavalisco Space Telescope Science Institute University of Massachusetts, Amherst 1 1 From January 2007.
PACS NHSC Data Processing Workshop Aug 26-30, 2013 Page 1 SPIRE Spectrometer Data: Calibration Updates, User Data Reprocessing, and Other Issues Nanyao.
PACS Page 1 NHSC Data Processing Workshop – Pasadena Aug 26-30, 2013 SPIRE Spectrometer Data Reduction: Mapping Observations Nanyao Lu NHSC/IPAC (On behalf.
Optimization Strategies for the NIRSpec MSA Planning Tool James Muzerolle.
Page 1 NHSC PACS Web Tutorial PACS 301 nhsc.ipac.caltech.edu/helpdesk NHSC/PACS Web Tutorials Running the PACS Spectrometer pipeline for CHOP/NOD Mode.
NASA Herschel Science Center - page 1 PACS NHSC Cycle 1 Open Time Proposal Planning Workshop 3-4 June 2010 ESA AO and NASA Funding Call Phil Appleton and.
1 NHSC PACS NHSC/PACS Web Tutorials Running PACS photometer pipelines PACS-402 (for Hipe 13.0) Level 1 to Level 2.5 processing: The JScanam pipeline Prepared.
Competitive Science with the WHT for Nearby Unresolved Galaxies Reynier Peletier Kapteyn Astronomical Institute Groningen.
New SPIRE features in HIPE 9.1 NHSC; Nov 28, 2012 PACS Page 1 What’s New in HIPE 9.1 ( SPIRE FTS) Nanyao Lu NHSC/IPAC (on behalf of the SPIRE ICC)
NHSC HIFI DP workshop Caltech, 8-9 March page 1 Pat Morris, NHSC DP Webinar, 9 March 2012 HIFI Spectral Maps in HIPE.
- page 1 PACS Phil Appleton on behalf of the NHSC/HSC and the PACS ICC ; especially Bart Vandenbussche and Pierre Royer (KUL Belgium) Instrument Performance.
F. Pepe Observatoire de Genève Optical astronomical spectroscopy at the VLT (Part 2)
Spectrometer The instrument used for the astronomers MinGyu Kim
# x pixels Geometry # Detector elements Detector Element Sizes Array Size Detector Element Sizes # Detector elements Pictorial diagram showing detector.
All-sky source search Aim: Look for a fast method to find sources over the whole sky Selection criteria Algorithms Iteration Simulations Energy information.
PACS Hitchhiker’s Guide to Herschel Archive Workshop – Pasadena 6 th – 10 th Oct 2014 Overview of SPIRE Photometer Data Reduction Pipeline Kevin Xu NHSC/IPAC.
Markus Nielbock (MPIA) – PACS Calibration Status Report Herschel Calibration Steering Group Meeting #24 PACS Calibration Status Report Markus Nielbock.
Single Object Spectroscopy and Time Series Observations with NIRSpec
The JWST Exposure Time Calculator
NIRSpec Time Series Observations
photometry and spectroscopy with PACS
Imaging with the James Webb Space Telescope
NHSC/PACS Web Tutorials
PACS Calibration Status Report
Single Object & Time Series Spectroscopy with JWST NIRCam
The Optical Sky Background
JWST NIRCam Time Series Observations
Diane Karakla ESAC “On Your Mark” Workshop Madrid, Sept
NHSC/PACS Web Tutorials Running PACS spectrometer pipelines PACS-302
Phil Appleton based on material from a study by Roland Vavrek (ESAC)
Resolving the black hole - nuclear cluster - spheroid connection
ESAC 2017 JWST Workshop JWST User Documentation Hands on experience
ESAC 2017 JWST Workshop NIRSpec MSA Planning Tool (MPT)
Astronomy 920 Commissioning of the Prime Focus Imaging Spectrograph
Introduction to Spectroscopy
Phil Appleton based on material from a study by Roland Vavrek (ESAC)
Detective Quantum Efficiency Preliminary Design Review
X-ray high resolution spectra in the VO: the case of XMM-Newton RGS
Presentation transcript:

- page 1 July NHSC Mini-workshop PACS NASA Herschel Science Center PACS Spectrometer AORs Phil Appleton 1Roberta Paladini - PACS Photometry7/22/11 CHOP/NOD Pointed or Mapping LINE SCAN and RANGE SCAN AORS Dario Fadda will cover Unchopped Mode observations in Line and Range scan modes

- page 2 July NHSC Mini-workshop PACS NASA Herschel Science Center Example of Spectroscopy with PACS Spectral Mapping of M82 with PACS from the SHINING team (Contursi et al. 2010) Prog Name.. KPGT_esturm_1

- page 3 July NHSC Mini-workshop PACS NASA Herschel Science Center 5x5 spaxels spaxel = 9.4” x 9.4” FOV 47”x47” Slit spectrometer fed by an IFU (5 x 5 “spaxels” cover 47 x 47 arcsec FOV) -- Each imaging “spaxel” is 9.4 x 9.4 arcsecs and provides a red and blue spectrum at that point on the sky Red and Blue detector arrays are fed by dichroic. The arrays are Ge-Ga unstressed (blue) and stressed (red) 25 x 16 arrays (i.e. 5 x 5 spatial and 16 spectral pixels Grating disperse light to detectors -3 orders possible (grating 8.5 grooves/mm) There are three spectral orders than can be sampled 1 st, 2 nd and 3 rd -- You choose which of the two orders you want to go with the red order You can select up to 10 lines in either or both of the selected orders to observe in the same AOR Slit spectrometer fed by an IFU (5 x 5 “spaxels” cover 47 x 47 arcsec FOV) -- Each imaging “spaxel” is 9.4 x 9.4 arcsecs and provides a red and blue spectrum at that point on the sky Red and Blue detector arrays are fed by dichroic. The arrays are Ge-Ga unstressed (blue) and stressed (red) 25 x 16 arrays (i.e. 5 x 5 spatial and 16 spectral pixels Grating disperse light to detectors -3 orders possible (grating 8.5 grooves/mm) There are three spectral orders than can be sampled 1 st, 2 nd and 3 rd -- You choose which of the two orders you want to go with the red order You can select up to 10 lines in either or both of the selected orders to observe in the same AOR Spectrometer QUICK OVERVIEW5 x 5 array of “spaxels” 47” x 47 “ FOV 1spax = 9.4” x 9.4” 5 sub-slits

- page 4 July NHSC Mini-workshop PACS NASA Herschel Science Center Order Selection and Line/AOR 1 st is always selected 2nd 3rd You can only select in any one AOR either the 2 nd or 3 rd order paired with 1 st order You can only select in any one AOR either the 2 nd or 3 rd order paired with 1 st order You can observe the same line 10 times (10 repetitions) or 5 different lines x 2 repetitions, or as many repetition-lines not exceeding 10 total per AOR. To repeat the whole sequence you can add more cycles. Note that calibration block is run at beginning or AOR. You can observe the same line 10 times (10 repetitions) or 5 different lines x 2 repetitions, or as many repetition-lines not exceeding 10 total per AOR. To repeat the whole sequence you can add more cycles. Note that calibration block is run at beginning or AOR. Either “Blue/RED” or “Green/RED” You can select multiple lines per AOR—for each line scanned you will get “for free” an observation in the blue or red band (e. g. If request 2 nd /1 st ordermodes and you observe [CII]158  m, you wlll “simultaneously” get “blue” observation at 158/2 = 79  m You can select multiple lines per AOR—for each line scanned you will get “for free” an observation in the blue or red band (e. g. If request 2 nd /1 st ordermodes and you observe [CII]158  m, you wlll “simultaneously” get “blue” observation at 158/2 = 79  m Accessible in range/SED mode

- page 5 July NHSC Mini-workshop PACS NASA Herschel Science Center PACS SPECTROSCOPY OPTIONS LINE SCAN RANGE SCAN Pointed Mapping (Raster) Chop/Nod Chop/Nod (bright line) Unchopped Unchopped (bright line) Chop/Nod Chop/Nod (bright line) Unchopped Unchopped (bright line) Pointed Mapping (Raster) THIS TALK

- page 6 July NHSC Mini-workshop PACS NASA Herschel Science Center Designing Spectroscopic AORs for PACS THERE ARE TWO KINDS OF “OBSERVATION” type for PACS SPECTROMETER LINE OR RANGE SPECTROSCOPY ? LINE OR RANGE SPECTROSCOPY ?

- page 7 July NHSC Mini-workshop PACS NASA Herschel Science Center Line Range If your single line in unresolved (narrow) If you know the observed line center accurately within ~ microns depending on the order observed If your single line in unresolved (narrow) If you know the observed line center accurately within ~ microns depending on the order observed If your single line in resolved (broad) (SMALL RANGE SCAN) If you are unsure of the redshift by more than the width or a normal scan (see Table 6.3 of the PACS OM for details) If you have closely space multiple lines (SMALL RANGE SCAN) If you want to perform an SED-type scan (SED or LARGE RANGE SCAN=very expensive) If your single line in resolved (broad) (SMALL RANGE SCAN) If you are unsure of the redshift by more than the width or a normal scan (see Table 6.3 of the PACS OM for details) If you have closely space multiple lines (SMALL RANGE SCAN) If you want to perform an SED-type scan (SED or LARGE RANGE SCAN=very expensive)

- page 8 July NHSC Mini-workshop PACS NASA Herschel Science Center LINE SPECTROSCOPY EXAMPLE THIS WOULD MEAN 1 st and 2 nd order [70-220] option as in example THIS WOULD MEAN 1 st and 2 nd order [70-220] option as in example

- page 9 July NHSC Mini-workshop PACS NASA Herschel Science Center 2. Now add the lines either manually or from database...one at a time. we will add three click to add line

- page 10 July NHSC Mini-workshop PACS NASA Herschel Science Center 3. Now set the expected line flux in W/m^2 if known and initial guess as number of repetitions on each line 3. Now set the expected line flux in W/m^2 if known and initial guess as number of repetitions on each line This is done by double-left-mouse clicking on line row Other inputs are possible but not essential

- page 11 July NHSC Mini-workshop PACS NASA Herschel Science Center Because the [NII]205 is likely weak, we give it more repetitions—we will come back to this in a moment as this is a guess for now sum of this column cannot > Next add redshift (per line) or radial velocity 4. Next add redshift (per line) or radial velocity 5. Now click to select observing mode

- page 12 July NHSC Mini-workshop PACS NASA Herschel Science Center Obs Mode allows choices within chop/nod or unchopped context pointed or raster map Chopper throw is also selected (1.5 (S), 3 (M) and 6 (L) arcmin) If you can’t chop off source use Unchopped.

- page 13 July NHSC Mini-workshop PACS NASA Herschel Science Center Chop/Nod involves a series of rapid chopping at Nod B, followed by a telescope move which places the target in the opposite chop position (Nod A) followed by a series of new chops Averaging the result of the chop-differencing should remove temperature variations in the “off chop” positions This does not work perfectly for PACS because of distortions in the chopper geometry SINGLE POINTED CHOP/NOD

- page 14 July NHSC Mini-workshop PACS NASA Herschel Science Center Chopped distortion on Large Throw If you suspect your source is not a point-source or you are very unsure of its position to 1-2”, probably best NOT to use POINTED mode, but a fully sample mapping mode. If you suspect your source is not a point-source or you are very unsure of its position to 1-2”, probably best NOT to use POINTED mode, but a fully sample mapping mode. Only the central few pixels are properly aligned for largest (LARGE) chopped throw. Best to use small or medium throw if possible.

- page 15 July NHSC Mini-workshop PACS NASA Herschel Science Center The Spectrometer “scans” by moving the grating up and down over pre-selected intervals. At each point in the grating scan 16 spectral pixels sample the spectrum during a read-out, then the grating is moved a step and the whole-thing is repeated. A standard “Line scan” usually consists of between 43 and 48 grating steps and the grating scans UP and DOWN once per “scan repetition” For a range scan, many more than 43 steps are executed to scan over a much larger range. For SED mode the entire blue or red filter band is sampled Typical AOR observing three lines in two Nod positions

- page 16 July NHSC Mini-workshop PACS NASA Herschel Science Center You can request a raster map of your source Consult the Pacs Observer Manual for the best mapping strategy Note the same mapping strategy is applied to all lines in same AOR --allows for ratio maps VISUALIZE your map IN HSpot CHOICE OF RASTER MAP STEP SIZE IS IMPORTANT IN MAPPING Do not use defaults! CHOICE OF RASTER MAP STEP SIZE IS IMPORTANT IN MAPPING Do not use defaults!

- page 17 July NHSC Mini-workshop PACS NASA Herschel Science Center Optimizing Mapping Strategy LARGE EXTENDED SOURCE USE: 16” point step/14.5” line step BLUE 24” point step/22” line step RED FULLY SAMPLED MAP (expensive) 3” x 3” BLUE (3 x 3 raster) But exploits full resolution on almost 4.5” x 4.5” RED (2 x 2 raster) point sources

- page 18 July NHSC Mini-workshop PACS NASA Herschel Science Center This 3 x 3 map provides small map of nucleus of this galaxy but chopper angle depends on time of year since it depend on telescope roll angle

- page 19 July NHSC Mini-workshop PACS NASA Herschel Science Center Optimizing the time on each line (Time estimator) HSpot calculates the line rms for a given set of line repetitions and cycles –User can play with the parameters to get the best performance

- page 20 July NHSC Mini-workshop PACS NASA Herschel Science Center clicking on this gives more details including S/N estimation for your set of lines, repetitions clicking on this gives more details including S/N estimation for your set of lines, repetitions

- page 21 July NHSC Mini-workshop PACS NASA Herschel Science Center The final rms and S/N you get will depend on a balance of line repetition blocks and the total number of cycles of these blocks you choose. You can increase the total time by requesting more set of data in the cycle window... this will hugely increase your AOR time which cannot go beyond18 hrs Iteratively adjusting these variables can allow you to get the best S/N for your set of lines in a given AOR. CYCLES LINE REPETITIONS

- page 22 July NHSC Mini-workshop PACS NASA Herschel Science Center Range Scan User can specify the range of the scan Useful for known broad or multiple lines Special version is SED mode where Blue/Red or Green Red bands scanned Range Scan is only mode that allows exploitation of extended second order

- page 23 July NHSC Mini-workshop PACS NASA Herschel Science Center Lets consider two examples CASE 1: SMALL RANGE OVER from 78.2 to 79.8 (as in example in previous slide) Only a little more expensive than standard line scan* CASE 2: SED SCAN OVER FULL PACS BAND Very expensive even for the recommended 2 repetitions *PITFALL: CHECK THE NUMBER OFSTEPS EXECUTED BY THE GRATING IN THE SMALL RANGE IS LARGER THAN43-48 (the number of steps executed in a normal line scan). This info is in the time estimator dialog box

- page 24 July NHSC Mini-workshop PACS NASA Herschel Science Center Small Range Scan Example 1.Choose Range Obs. 2.Enter Target 3.Select range filter set appropriate for range 4. Choose blue and red edge of scan by selecting ADD RANGE 1.Choose Range Obs. 2.Enter Target 3.Select range filter set appropriate for range 4. Choose blue and red edge of scan by selecting ADD RANGE 5. Choose sampling of grating -High not Nyquist for small range to match equivalent line scan mode) 6. Proceed as before to set up pointed or mapping mode 5. Choose sampling of grating -High not Nyquist for small range to match equivalent line scan mode) 6. Proceed as before to set up pointed or mapping mode

- page 25 July NHSC Mini-workshop PACS NASA Herschel Science Center Excercise for Workshop Create 2 AORs. Target : QUASAR 3C x10^-18 W/m^2 in [OI] and 50x10^-18 W/M^2 [CII] redshift = )Standard C/N line scan of these lines in single pointing mode with small chopper throw to get S/N ≥ 6.5 in each line 2)Small range scan covering 2 microns around each line. High sampling rate

- page 26 July NHSC Mini-workshop PACS NASA Herschel Science Center NOW OVER TO DARIO TO EXPLAIN UNCHOPPED MODE

- page 27 July NHSC Mini-workshop PACS NASA Herschel Science Center 3c273 3c273.aor

- page 28 July NHSC Mini-workshop PACS NASA Herschel Science Center Some considerations in Range-scan mode 1) Choice of filter combinations Range scan allows user to observe with the 2 nd order far into the blue. (Extended Second order). This is not available in line scan mode. select RANGE MODE

- page 29 July NHSC Mini-workshop PACS NASA Herschel Science Center 2. Sanity Check that your range is really larger than a normal line scan in time estimator This is the number of steps made by the grating to scan over your line. It far exceeds the maximum of steps you get in normal line scan. YOUR CHOICE OF RANGE SCAN IS JUSTIFIED!! This is the number of steps made by the grating to scan over your line. It far exceeds the maximum of steps you get in normal line scan. YOUR CHOICE OF RANGE SCAN IS JUSTIFIED!!

- page 30 July NHSC Mini-workshop PACS NASA Herschel Science Center Unlike line-scan, there is no redshift calculator—so if you are searching for a line you will need to calculate the observed wavelengths that you want to search over. More than one set of ranges is possible within one AOR. These are specified as separate ranges. Unlike line-scan, there is no redshift calculator—so if you are searching for a line you will need to calculate the observed wavelengths that you want to search over. More than one set of ranges is possible within one AOR. These are specified as separate ranges. 3. As with normal line scan, in small range scan mode, up to 10 ranges are allowable with 1 repetition. In SED Mode, only one SED scan is allowed per AOR. Warning: The step size of the grating is optimized for the “primary” target line. Any “secondary” (i.e. for free) spectrum you may get in parallel may not have the optimal sampling because it is fixed by the primary step size. Warning: The step size of the grating is optimized for the “primary” target line. Any “secondary” (i.e. for free) spectrum you may get in parallel may not have the optimal sampling because it is fixed by the primary step size.

- page 31 July NHSC Mini-workshop PACS NASA Herschel Science Center FULL SED Range Scan To perform a full SED you will need to create 2 AORs. SED B2B +long R1 ( and obtained together in same scan) + SEB B2A + short R1 (51-73 and obtained together in same scan) alternatively you can obtain a higher res (3 rd order) scan in blue but get a shorter range in red (SED B3A + long R1) CLICK ON ADD RANGE after selection of SED range. The two AORs should be concatenated to ensure the run successively. To perform a full SED you will need to create 2 AORs. SED B2B +long R1 ( and obtained together in same scan) + SEB B2A + short R1 (51-73 and obtained together in same scan) alternatively you can obtain a higher res (3 rd order) scan in blue but get a shorter range in red (SED B3A + long R1) CLICK ON ADD RANGE after selection of SED range. The two AORs should be concatenated to ensure the run successively.