Spectroscopic Surface Analysis and Cleaning Verification with SpotView ® Systems.

Slides:



Advertisements
Similar presentations
FieldSpec® HH UV/VNIR HandHeld Spectroradiometer.
Advertisements

1 CHM 585 / 490 Chapter SPC Statistical Process Control.
Phytoplankton absorption from ac-9 measurements Julia Uitz Ocean Optics 2004.
CHEMISTRY ANALYTICAL CHEMISTRY Fall
AAS and FES (Ch 9, 7th e, WMDS)
Atomic Absorption Spectrometry Dr AKM Shafiqul Islam University Malaysia Perlis.
HL Chemistry - Option A: Modern Analytical Chemistry ATOMIC ABSORPTION SPECTROSCOPY.
Applications of CCD Array Spectrometers in Undergraduate Education at EIU Jonathan Blitz and Daniel Sheeran Department of Chemistry.
Drug Delivery & Tissue Engineering Laboratory
Fiber Optics BASIC FIBER OPTIC LINK.
World Health Organization
Summary 1 l The Analytical Problem l Data Handling.
Tracking Migratory Birds Around Large Structures Presented by: Arik Brooks and Nicholas Patrick Advisors: Dr. Huggins, Dr. Schertz, and Dr. Stewart Senior.
Infrared Radiation 780 nm m Near, Mid and Far
Elaine Martin Centre for Process Analytics and Control Technology University of Newcastle, England The Conjunction of Process and.
Chapter In Chapter 3… … we used stemplots to look at shape, central location, and spread of a distribution. In this chapter we use numerical summaries.
Multipurpose analysis: soil, plant tissue, wood, fruits, oils. Benchtop, portable Validation in-built, ISO compliant Little or no sample preparation. Rapid.
Kyiv, TRAINING WORKSHOP ON PHARMACEUTICAL QUALITY, GOOD MANUFACTURING PRACTICE & BIOEQUIVALENCE Validation of Analytical Methods Used For Bioequivalence.
Chemometrics Method comparison
IR – Infrared Spectroscopy. What is IR Spectroscopy? Infrared spectroscopy is the analysis of infrared light interacting with a molecule. IR spectroscopy.
Procedure for Pro4 using Keithley
(Enzyme Linked Immunosorbent Assay)
Total X-ray Fluorescence Spectroscopy (TXRF) Contact: World Agroforestry Centre (ICRAF), P.O. Box Nairobi, Kenya. Tel:
Mining Applications and Chemometrics
CEMTREX, INC. MODCON SYSTEMS LTD NIR Systems July 2010.
2010 CEOS Field Reflectance Intercomparisons Lessons Learned K. Thome 1, N. Fox 2 1 NASA/GSFC, 2 National Physical Laboratory.
Inference for regression - Simple linear regression
Engineering NDT Advanced NDE Pressure Equipment Integrity Management Lab Analysis Development of NDT Inspection Techniques For Heavy Wall Stainless Steel.
TEMPLATE DESIGN © v DIRECT DEMONSTRATION OF THE GREENHOUSE EFFECT Abstract Consider these three “theories:” climate change,
Chapter 6 - Chromatography
MultiSimplex and experimental design as chemometric tools to optimize a SPE-HPLC-UV method for the determination of eprosartan in human plasma samples.
Gas Chromatography Carrier Gas Flow Control Injector Port Column Column Oven Detector Recorder The GC system consists of gas supplies for the mobile phase.
The following minimum specified ranges should be considered: Drug substance or a finished (drug) product 80 to 120 % of the test concentration Content.
Lab Bot 800 Dual Arm Fully Automated Liquid Handling Workstation.
Color Sensors We Know Until Now, Our History with Color Sensing Technology has Been Limited to a Class of Sensors Known as “Color Mark” Sensors Our Offerings.
Economics of Alternative Energy Sources and Globalization Nov Orlando, Florida The Economic Feasibility of Bio-energy Generation for Peak Demand.
Miriam Israelowitz 1 and Dr. David L. Wilson 2 1 Department of Physics, Case Western Reserve University, Cleveland OH, 2 Deparment of Biomedical Engineering,
Quality Control Lecture 5
Sphere Standards and Standard Spheres Dr. Richard Young Optronic Laboratories, Inc.
UV-Vis Absorption Spectroscopy
Infrared Spectroscopy
Raw material verification with AssureID: problems and solutions Dr. Yaroslav Sokovikov Yuri Shishkin SchelTec AG.
Radiometric Correction and Image Enhancement Modifying digital numbers.
Quality Assurance How do you know your results are correct? How confident are you?
By: Arafath and Nick. What is it  Chromatography is a technique that is used to separate the substances present in a mixture.  It is widely used to.
Validation Defination Establishing documentary evidence which provides a high degree of assurance that specification process will consistently produce.
Use of Solar Reflectance Hyperspectral Data for Cloud Base Retrieval Andrew Heidinger, NOAA/NESDIS/ORA Washington D.C, USA Outline " Physical basis for.
Study of T 1 relaxation time A proposal to test T 1 using a dilution fridge and SQUID NMA at Royal Hollow University,London.
Receive Antenna Performance Comparison. Receive Antenna Monitoring The receive antenna was installed in its permanent location inside the chamber A spectrum.
BME 353 – BIOMEDICAL MEASUREMENTS AND INSTRUMENTATION MEASUREMENT PRINCIPLES.
LECTURE 13 QUALITY ASSURANCE METHOD VALIDATION
Reaction Monitoring with ReactionView ® and ReactionProbe™ In-situ contamination and surface analysis with SpotView and SpotView-SL © Remspec Corp
Reaction Monitoring with the ReactionView ® System Remspec Corporation © Remspec Corp
FAST SCAN SUBMILLIMETER SPECTROSCOPIC TECHNIQUE (FASSST). IVAN R. MEDVEDEV, BRENDA P. WINNEWISSER, MANFRED WINNEWISSER, FRANK C. DE LUCIA, DOUGLAS T. PETKIE,
An Experimental Approach to the Prediction of Complete Millimeter and Submillimeter Spectra at Astrophysical Temperatures Ivan Medvedev and Frank C. De.
Infrared Microspectroscopy A training guide for using light microscopy and infrared spectroscopy to analyze materials.
What Does Remspec Do? Remspec provides fiber-optic reaction monitoring solutions for R&D and process development. Remspec develops reaction-monitoring.
EQUIPMENT and METHOD VALIDATION
Date of download: 6/22/2016 Copyright © 2016 SPIE. All rights reserved. Photographs of exposed femoral bone surfaces and surrounding tissue prepared for.
 FT-IR stands for Fourier Transform Infrared, the preferred method of infrared spectroscopy. In infrared spectroscopy, IR radiation is passed through.
Portable SERS Detector for Simultaneous Detection of Trace-level Polycyclic Aromatic Hydrocarbons on Superfund Sites Wayne Weimer (PI) and Monika Wilson,
Correction of FTIR data for the effect of temperature variation Peter J. Melling, Remspec Corporation, Charlton MA.
Determinations and Interpretations of FTIR Detection Limits
Quality is a Lousy Idea-
UV/VIS SPECTROSCOPY.
Chromatography- TLC & HPLC
Quality is a Lousy Idea-
CLEANING VALIDATION FOOD & BEVERAGE –– WASTEWATER –– LABORATORY –– PHARMACEUTICAL & MEDICAL DEVICE.
Quality Assessment The goal of laboratory analysis is to provide the accurate, reliable and timeliness result Quality assurance The overall program that.
Damiana Gentili Qualified Person/QU Director 09/05/2019
Presentation transcript:

Spectroscopic Surface Analysis and Cleaning Verification with SpotView ® Systems

Overview © Remspec Corp. 2014

SpotView® and SpotView-SL Easy-to-use, portable system. Robust, transferable calibration. Realtime, in-situ detection and quantitation down to microgram levels. CFR 21/Part 11 compliant software. © Remspec Corp. 2014

FTIR Spectroscopy FTIR in the mid-IR range is the most sensitive optical measurement technique – extinction coefficients are larger than either in the NIR or the UV-visible range. Almost all organic compounds, including oils, lubricants, and cleaning agents have distinctive mid-IR spectra. © Remspec Corp. 2014

Grazing Angle FTIR Spectroscopy © Remspec Corp. 2014

Interchangeable with grazing-angle SpotView Shaft diameter 6 mm Direct reflectance is less sensitive than grazing angle, but can be used in tight places and on small objects. SpotView-SL © Remspec Corp. 2014

SpotView-SL SpotView-SL can be configured with a single cable, up to 3 m long. Ideal for tablet presses etc. © Remspec Corp. 2014

SpotView-SL © Remspec Corp. 2014

SpotView-SL The SL probe is the best choice for contamination levels above about 3 mg/ft 2 (approx. 3 μg/cm 2 ), equivalent to a film thickness of about 3 μm. The grazing-angle method breaks down for films above about 4 μm in thickness. © Remspec Corp. 2014

ValveView™ for Examining Restricted Interior Surfaces Like SpotView®, uses the grazing-angle method, this time inside a small hollow object –In use for cleaning validation by manufacturers of semiconductor gas- handling equipment –Used on interior surfaces of small ball valves Valve holder Fiber-optic cable Output Mirror Input mirror Detector © Remspec Corp. 2014

ValveView™ for Examining Restricted Interior Surfaces ValveView has been in use at a Taiwanese valve company for about ten years. –It is used as a QC tool to ensure an oil-free surface inside each valve. – ( 1 ) CLASS IV Max.1mg/m 2 – ( 2 ) CLASS V : Max.0.1mg/m 2 Valve holder Fiber-optic cable Output Mirror Detector © Remspec Corp. 2014

Calibration © Remspec Corp. 2014

Sample Preparation Smear Method –Dispense small amount of known API solution onto surface –Smear evenly –Collect spectra after drying –Estimate coverage by: Calculation from solution concentration. –Suitable method for demonstrations and qualitative analysis. © Remspec Corp. 2014

Sample Preparation Spray Method –Spray API solution on surface with air brush –Collect spectra after drying –Wash entire surface –Analyze washing by, e.g., HPLC –Calculate surface coverage © Remspec Corp. 2014

Sample Preparation Quantitative Printing –Developed from ink-jet printing technology –Provides known surface concentrations without requiring secondary analysis method. –Available as a service from Remspec. © Remspec Corp. 2014

SpotView-SL Calibration: some simple rules Smear Method for quick feasibility studies Use sample of the same material as the target reactor or mixer (metal, glass, plastic, etc.) Consider the range of surface finishes that you may encounter (mirror polish, matte, etc.) Spray or Print Method better for developing working calibrations and determining true detection limits. Spray or Print Method essential for multi-compound calibration. Secondary analysis (for Spray method) Is the analyte UV-active? How easy will it be to wash off the sample? © Remspec Corp. 2014

Set of API spectra –BioPharm 15(5), May 2002, pp Air brush /weight difference method. Unknown API from Pfizer Puerto Rico plant. © Remspec Corp. 2014

SpotView/PLS1 Results versus Swab/HPLC Second, independent set of coupons loaded with API. SpotView® spectra collected. Pfizer in-house swabbing method used to obtain “conventional” loading data. © Remspec Corp. 2014

SpotView-SL Calibration: API on stainless steel Intensity varies with concentration Can be visually estimated down to about 3 μg/cm 2. At lower surface concentrations, peak shape changes are often observed. Chemometric calibrations can be established down to about 1 μg/cm 2. © Remspec Corp. 2014

SpotView-SL Calibration: API on stainless steel Results are shown for a cross-validation test of a PLS1 model. Chemometric calibrations can be established down to about 1 μg/cm 2. © Remspec Corp. 2014

Amlodipine on Stainless Steel Spray method, with calibration by HPLC In this example, the drug is the only compound on the surface. Grazing-angle SpotView was used; note the lower RMS error compared to SpotView-SL © Remspec Corp. 2014

Amlodipine and CIP-90 on Stainless Steel Spray method, with calibration by HPLC In this example, the drug and a variable amount of CIP-90 (cleaning agent) is present on the surface. Note the increased scatter, larger estimated error, and higher rank of the model (it uses more factors). © Remspec Corp. 2014

Amlodipine and CIP-90 on Stainless Steel Graphing the average predictions against HPLC values highlights the increased scatter when CIP-90 is present. Amlodipine And CIP-90 © Remspec Corp. 2014

Case Study © Remspec Corp. 2014

Case Study: inside stainless steel production tanks The SpotView FTIR system for surface analysis was used to examine the interior surfaces of two tanks, T-2221 and T-2211, interior surfaces of the CIP recovery tank and pump, and of the CIP return pump P8211. A operator was lowered into the tank carrying the operating spectrometer. The SpotView head and fiber-optic cable were lowered separately and connected in situ. The computer was operated by a second person outside the tank. A total of 69 spectra was collected over a period of three days from selected sites on the walls of the tanks, on agitator shafts and spray balls, and from the manways and manway covers. Separately, spectra were collected from surfaces of the CIP recovery tank and pump. © Remspec Corp. 2014

Case Study: inside stainless steel production tanks Typical “100% line” taken from the clean background surface. Note (a) noise spike at approx cm -1, arising from residual Se-H in optical fiber and (b) minor features from atmospheric H 2 O and CO 2. © Remspec Corp. 2014

Case Study: inside stainless steel production tanks Two spectra from headspace surface (T-2221). Note features in upper spectrum: (a) pronounced shift in baseline, (b) centered near 2960 cm -1 and (c) spectral density between 1000 and 1770 cm -1. © Remspec Corp. 2014

Case Study: inside stainless steel production tanks T-2211, agitator shaft. Note spectral features in top trace, very similar to those found in a spectrum from T-2221 headspace on Day 1. © Remspec Corp. 2014

Case Study: inside stainless steel production tanks Two spectra from the manway lid of T These spectra are extremely noisy. The reflected signal is very low. © Remspec Corp. 2014

Case Study: inside stainless steel production tanks CIP supply pump. Note spectral features between 3600 and 2800 cm -1, and spectral density below 1800 cm -1. © Remspec Corp. 2014

Case Study: inside stainless steel production tanks Comparison with the spectrum from T-2221 headspace (olive trace) and from T2211 agitator shaft (green trace) suggests that the same or similar residue has been detected in all cases. © Remspec Corp. 2014

Case Study: inside stainless steel production tanks Of the 69 spectra collected, 65 showed no features attributable to organic residue on the surface. This indicates that the surfaces are free of spectroscopically detectable organic residue to a level better than 0.5 μg/cm 2. Four spectra—one each from tanks T-2221 and T2211 and two from the pump on the CIP recovery skip--showed a very small spectroscopic signature for an organic residue that was (a) the same or very similar in each case (b) highly localized in the two tanks (attempts to detect anything on immediately adjacent surfaces resulted in featureless spectra). © Remspec Corp. 2014

Software © Remspec Corp. 2014

SpotView ® uses CVal ™ Software for Routine Cleaning Validation Supervisor Mode for setting up procedures and Operator instructions. Operator Mode for routine cleaning validation Procedures are digitally locked and verified each time they are used. © Remspec Corp. 2014

CVal ™ Software for Routine Cleaning Validation Procedures and Results can be displayed using Viewers that verify each file as unchaged. Procedure and Results file are also saved in simple, human- readable format for long-term readability. © Remspec Corp. 2014

Conclusions © Remspec Corp. 2014

Expanding the Scope of Reflectance FTIR Spectroscopy SpotView® is ideal for surfaces that are: –Flat or moderately curved –Accessible with the SpotView® head –Interior surfaces of large reactors, for example SpotView®-SL is ideal for surfaces that are: Highly curved Restricted access Valves and nozzles, for example © Remspec Corp. 2014

In Summary SpotView can measure surface laodigns down to 0.2 μg/cm 2. SpotView-SL can measure loadings down to about 1-3 μg/cm 2. The results are quantitative and compare well with existing pharma industry methods like swabbing. In-situ results are obtained from a hand-held device in seconds. © Remspec Corp. 2014