Birmingham Status ASIC shear tests (250nm Panel with hybrids cured at room temp and with heated plate, sent to Berlin for shear testing. (Complication:

Slides:



Advertisements
Similar presentations
By: Irfan Nadiadi Sarah Mugharbil Rhiannon Kemp Michael Reese.
Advertisements

Biophysics of somersault and arm sets in trampolining John Mitchell Thanks to Lisa Withey + Jack Mitchell for performance.
Labcliq, How to certify a corrective action
SUR 111 Establishing the Sterile Field. Skill Assessments Continue with the following skill assessments from Lab #4: 12-1 Surgical Hand Scrub Dry, Gown,
ATLAS Module building at Glasgow
1 Short update Itzhak Tserruya HBD meeting BNL, April 11, 2006.
Spiral Stairs Assembly Instruction By Laser Dollhouse Designs
Composite Mold Design Project 1 – prepreg press mold.
Hybrid assembly at Glasgow. Placing ASICs Arrange 20 ASICs in ASIC tray with strip bond pads facing outwards – ASICs to be used in ‘Cat A’ sample boxes.
Design Ash finished electric hybrid tracing to connector fields –Changes to allow for HCC-less and HCC running on one hybrid awaiting final confirmation.
Status Update on Mechanical Prototype in Rome November 6,
AquaGlo Water Detector Kit For Detecting Water in Jet Fuel
A common error that appears on the copier’s screen is seen here when a scan to Sharpdesk is not sent to the computer successfully. This guide intends to.
QA during Stave Core Assembly Stephanie Qing Yang (Oxford) 25 th Sept 2014 WP4 f2f meeting at RAL.
EASY TEAM MANAGER By Dave Abineri EASYWARE: PO Box 231, Milford, OHIO (Cincinnati) Phone: (513) Use UP arrow to move to the NEXT slide Use.
SAG Infotech Private Limited Soft solutions for those can not afford to make errors. How to Update New changes in Our Softwares?
Received new "130nm" jigs from Liverpool and after the "module workshop" 25/3/15 at Liverpool and ready to make dummy modules New jigs need to be slotted.
Tips for creating a line graph. Mrs. McPhillips wanted to see how the temperature of the classroom changed during the day. She took the temperature of.
1 WP3 Bi-Weekly Meeting Activities at Liverpool 1.Evaluation of Compact DCDC converter Designed to match up to an ABC130 module 2.Status of FIB’d hybrid/module.
Faculty Webpage Design Minimum Requirements. Go to: then High Schoolhttp://gcsc.groupfusion.net/
What is the difference between mass and weight?. Mass O Quantity of matter O Measured with a balance O How much “stuff” is there O Constant.
Tuesday Warm Up October 22. A glass beaker is placed on a hot plate. Five hundred milliliters of room temperature water are added to the beaker. If the.
Stave Module Status Tony Affolder The University of Liverpool On behalf of cast of thousands… ATLAS Upgrade Week November 10,
12 Aug 2013 ATLAS Tracker Upgrade Status Birmingham 1 - Small vacuum pump holding hybrid flat on panel (which it is ‘strong enough’ to do) - Since picture.
M. Gilchriese Module Assembly and Attachment at LBNL M. Gilchriese for F. Goozen April 2000.
Andy Blue Glasgow Update. Andy Blue WP3 Meeting Summary ESD Protection –Part all arrived and installed Compressed Air Controls –New lines and panel being.
21 Nov 2013 Juergen Thomas: ATLAS Tracker Upgrade: Hybrid Production and Test Setup at Birmingham 1 ATLAS Tracker Upgrade: Hybrid Production and Tests.
GEM Foil Stretching Using a Low-Cost Infrared Heating Array Elizabeth Esposito, Erik Maki Faculty Advisor: Dr. Marcus Hohlmann, Dept. of Physics and Space.
Assembly Procedure ALICE Outer Barrel Stave 14 Module 2 Cold Plates 1 StaveMarco Kraan Paul Kuijer.
Petalet-Stavelet; 13 July Birmingham Update Gluing to mechanical sensor with Epolite (as reported earlier). 1 st hybrid – too much glue on stencil.
Birmingham Update Module bonding (Sam and Simon) Great difficulty bonding on to patterned glass ASICs. (OK on sensor). After 1 st two rows of bonds, abandon.
Fred Doherty Module Work Fred Doherty. Stave Module Building Hybrid Bonding Bonding table for the BJ820 still in workshop Modified working height of the.
S Pyatt UV glue dispensing studies on the Dima Dotmaster 1.
How To Experiment By Mr. Reiner. Observation You notice something, and wonder why it happens. You see something and wonder what causes it. You want to.
Hybrid panel heated plate study Currently the curing of the ASIC glue for the hybrid panels are done at room temperature. This is a study to determine.
WP3_Bham; 10July 2014; John Wilson1 Gluing: more investigations (Simon and Sam) New clamping method provides a good base for systematic studies. Sketch.
David Bailey Gluing. Silicon /pcb assembly Previously Using Sony Robot and precision dispenser Have established acceptable glue dot parameters Dot electrical.
Production Readiness Review at PNPI Chamber assembling: Main production and quality control steps 30 January 2004 – G.Alkhazov 1.Input components control.
Birmingham update: making modules? ASICS to hybrid Gluing: many trials i) heated plate with silver loaded (8 hybrids i.e. 1 panel per day) ii) UV cured.
Gluing, measuring and shearing Heated plate curing Is the process feasible? Tests with 130nm hybrids Measure resulting glue thickness Determine the shear.
WP3_Bham; 29May 2014; John Wilson1 Heated plate curing Tests with 130nm hybrids and glass ASICs the glue thickness is controllable. i)Room temp curing.
Test set up Heat source: The radiant heat source used is shown in Fig 1. Temperature of source temp was set to 650 Materials tested: 6”x 6” samples of.
Lyon Gantry Status CERN 15 Sept D. Contardo Calibration Plates and Tools Readiness for production.
Gluing trials continuing: Loctite is favourite (for Dispensemaster) Bonding: exercising the machine; practising in laying down patterns (Simon and.
Lesson 3 Relationships. Stretching a spring What is the input variable here and what is the outcome variable?
WP3; 15 Jan 2015; John Wilson.1 Birmingham Update All back and operational after Christmas! Simon in contact with Dario Ariza at DESY re gluing (Boron.
Stave #12 This stave core was built together with William Emmet, Tom Hurteau, and Jeffery Ashenfelter from Yale University in the week of November.
Do now What is wrong with the set-up to this question; How many seconds are in a year? Seconds / year = 1 year x (1 yr/365 days) x (1 day/24hrs) x (1 hr/60.
Hybrid and Module Status 1. Hybrid Delivery First hybrids over-etched and shrunk due to changes in design and mistakes in manufacturing – Shrinkage for.
WP3_Bham; 15May 2014; John Wilson1 Heated plate curing Tests with 130nm hybrids and glass ASICs i) Room temp curing the glue thickness is controllable.
How does the Sun warm the Earth? Look at the picture on page 364. The sunlight strikes the Earth most directly at the Equator. The sun’s rays strike the.
Creating your own quiz ClickClick here to open the quiz webpage This quiz will go with your PowerPoint. It will be created to test students on the information.
MM Status Mostly unchanged (Feb. 3 rd 2016). Parts Mildly modified bridges, allowing to actually move 130nm pickup tools along r*phi –Turned out to be.
The problem is to design, construct and test the most efficient bridge within the specifications. Back to start of slide show.
Irradiations / Birmingham Status Paul Dervan, Tony Affolder and Sven Wonsak The University of Liverpool, UK Paul Dervan, Paul Hodgson, Kerry Parker, Matthew.
Grid Pix Field Simulations and precision needed for a module Peter Kluit, Jan Timmermans Prepared 16 May 2016.
Planned Preventive Maintenance for Fridges To improve your fridge’s function do the following tasks all the time: 2) Defrost your fridge once a month OR.
Marc Anduze – EUDET Meeting – PARIS 08/10/07 Mechanical R&D for EUDET module.
BM&N STS ladders assembly in VLHEP
Berkeley status Aug 10th, 2012.
→ need to guide UV light into gap; also beware temp effects
Glue curing studies (contd)
Sapphire Fused Silica and EP30-2
Ladder Assembly All tools and jigs produced Glue dispensing works
Unit 2: Velocity Day 1 Notebook Check, Variables for real, Walk-Jog-Run, Review Check for Understanding.
ITK Strip Module Meeting; 12st October 2015
Group meeting, 2nd Sept, 2013; JAW
Update from Birmingham
(can use two lines for Title if needed)
SAG Infotech Private Limited
Presentation transcript:

Birmingham Status ASIC shear tests (250nm Panel with hybrids cured at room temp and with heated plate, sent to Berlin for shear testing. (Complication: very variable glue thicknesses) Shear tests completed (thanks to Luise) Phone meeting tomorrow (Friday) to discuss 130nm: panels + placement jig measured by Sam (see next pages) Testing (Juergen) Update SCTDAQ to latest version Updated Root to WP3_Birmingham; 30 Jan2014; John Wilson

130nm Panels 4 panel were received, 3 of which had 8 hybrids present, 1 had only 1 The hybrids were named B130-1/2/3/4 so that the panels and hybrid can be tracked whilst here For the data shown, 4 point measurements were made on each pad and an average taken The 0 height is the panel surface as measured from the “landing pads”

Measuring the four (130nm) panels (Sam) 3WP3_Birmingham; 30 Jan2014; John Wilson

All hybrids have the pads below the panel surface height, this is due to them not having the “pre-preg for lamination” that the landing pads do. (This is something Tony has mentioned)

130nm ASIC Placement Jig The placement jig was measured at room temperature and then heated and measured again to see what variation there would be under the heat cure method. The Jig only reached 30C rather than the 35C of the previous Jig Again all measurements are an average of 4 points measured on the surface

The first two sets of measurements were taken with the jig clamped to the CMM to prevent movement during measuring. The 3 rd run was done without clamping to see if the clamping was affecting the results. The graph shows the heights of the “placement pads” of the jig. The heights are in µm. They show the height of the pads above the hybrid surface if the jig was placed on the hybrid The “Micro Jacks” appear to be expanding more than the main jig body, moving the placement pads further away from hybrid surface during heating. When heated the jig appears to bend slightly in the middle, making the middle of the jig slightly further away from the hybrid surface. Could this be due to the 2 metal types on the jig? Although there is a change when heated it appears although the results are predictable meaning the jig can be adjusted prior to ASIC placement.

With all these measurements taken we can adjust the Jig so that we achieve the 80µm glue gap. How best to adjust the jig?

Next Steps 250nm Receive back shear results + tested hybrids from Berlin. Conclusions? 130nm Adjust placement jig legs to obtain glue thickness of 80μm. Try gluing + curing with heated plate: test run first to check what temperature is attained etc. 8WP3_Birmingham; 30 Jan2014; John Wilson

Wish list LV supplies to power heated plate (4 off) : £800 approx Certify nitrogen system in cleanroom for storage boxes: £1000 Weighing scales (0.1mg precision) : £2200 Upgrade to Dotmaster (modern software; lay down lines): 4400 Euros 9WP3_Birmingham; 30 Jan2014; John Wilson