© Copyright 2009 by the American Association for Clinical Chemistry Seven Direct Methods for Measuring HDL and LDL Cholesterol Compared with Ultracentrifugation.

Slides:



Advertisements
Similar presentations
ABSTRACT CONCLUSIONS BACKGROUND Heart Rate Recovery: An Indicator of Fitness Among Middle School Children Daniel Simhaee, Roopa Gurm, Susan Aaronson, Jean.
Advertisements

Robert K Huff PharmD. Candidate May Objectives The study was designed to examine 3 main aspects Biochemical effects Safety Tolerability Evacetrapib.
Experiment 6 Determination Of Cholesterol In HDL
Quality Assurance.
Utilization of Assay Performance Characteristics to Estimate Hemoglobin A 1c Result Reliability A. Woodworth, N. Korpi-Steiner, J.J. Miller, L.V. Rao,
Association of 1,5-Anhydroglucitol with Diabetes and Microvascular
Measurement System Analysis Kevin B. Craner Boise State University October 6, 2003.
Chemometrics Method comparison
MLAB 2401: Clinical Chemistry Keri Brophy-Martinez Lipids and Lipoproteins Assessment.
Unit #7 - Basic Quality Control for the Clinical Laboratory
Medical Laboratory Diagnostic Services Tests&Values.
Methods to Detect Red Cell Membrane Disorders
Quality Assurance.
Quality Assessment 2 Quality Control.
Methods to Detect Red Cell Membrane Disorders
Method Selection and Evaluation Method Selection and Evaluation D. Kefaya EL- Sayed Mohamed Prof. Of Clinical Pathology (Clinical Chemistry), Mansoura.
Hyperlipidemia Chapter 22. VIDEO There are four principal lipoprotein classes:lipoprotein 1. Chylomicrons are derived from intestinal absorption of exogenous.
Measurements for 8 Common Analytes in Native Sera Identify Inadequate Standardization among 6 Routine Laboratory Assays H.C.M. Stepman, U. Tiikkainen,
THE LIPID PANEL What are we missing? Robert St. Amant, MD, FAAFP Diplomate, American Board of Clinical Lipidology Baton Rouge General Medical Director,
Cholesterol.
Anura L. Jayewardene, PhD Drug Research Unit at the General SFGH, 1001 Potero Ave. Bldg 100, Rm 157 San Francisco, CA Phone: (415) FAX:
QUALITY ASSURANCE Reference Intervals Lecture 4. Normal range or Reference interval The term ‘normal range’ is commonly used when referring to the range.
© Copyright 2009 by the American Association for Clinical Chemistry Glucose Meter Performance Criteria for Tight Glycemic Control Estimated by Simulation.
Copyright® Raisio A plant stanol yogurt drink alone or combined with a low-dose statin lowers serum triacylglycerol and non-HDL cholesterol.
Quality Control Lecture 5
© Copyright 2009 by the American Association for Clinical Chemistry Nonfasting Lipids, Lipoproteins, and Apolipoproteins in Individuals With and Without.
© Copyright 2009 by the American Association for Clinical Chemistry Agreement Between Fasting and Postprandial LDL Cholesterol Measured with 3 Methods.
5. Quality Assurance and Calibration Quality assurance is We do to get the right answer for our purpose. Have Sufficient accuracy and precision to support.
Evaluation of the Presage™ ST2 ELISA Jun Lu 1, David G. Grenache 1,2 1 ARUP Institute for Clinical and Experimental Pathology, Salt Lake City, UT 2 Department.
© Copyright 2009 by the American Association for Clinical Chemistry γ′ Fibrinogen: Evaluation of a New Assay for Study of Associations with Cardiovascular.
Serum biochemical parameters glucose assay Biochemistry Clinical practice CLS 432 Dr. Samah Kotb Lecturer of Biochemistry 2015.
Comparability of methods and analysers Nora Nikolac
Application of Westgard multi rules in medical laboratories
Clinical diagnostic biochemistry - 8
Study Flow Diagram Holvoet P, et al. JAMA 2008;299: The Figure shows the selection of 1889 participants who did not have metabolic syndrome at year.
© SSER Ltd..
Box and Whisker Plots Example: Comparing two samples.
LAB (6): LIPIDS PROFILE KAU-Faculty of Science- Biochemistry department Clinical biochemistry lab (Bioc 416) 2013.
Lab 6 TC, LDL-C, HDL-C, and TG T.A. Bahiya Osrah
Date of download: 5/29/2016 Copyright © 2016 American Medical Association. All rights reserved. From: Effects of a Fixed-Dose Combination Strategy on Adherence.
SEMINAR ON PRESENTED BY BRAHMABHATT BANSARI K. M. PHARM PART DEPARTMENT OF PHARMACEUTICS AND PHARMACEUTICAL TECHNOLGY L. M. COLLEGE OF PHARMACY.
Outline of Today’s lecture 1. Introduction of Lipoproteins 2. Discuss the different types of Lipoproteins 3. Identify healthy HDL & LDL levels 4. Principle’s.
Lab (6): Lipids profile KAU-Faculty of Science- Biochemistry department Clinical biochemistry lab (Bioc 416) 2012 T.A Nouf Alshareef
 Disorders of iron metabolism are evaluated primarily by : 1. packed cell volume 2. Hemoglobin & red cell count and indices 3. Total iron and TIBC, percent.
Triglyceride determination
Unit #6 - Basic Quality Control for the Clinical Laboratory
BAE 6520 Applied Environmental Statistics
Arabinda Mohan Bhattarai, MBBS, MD (Biochemistry) Asst Prof, NAIHS
Evaluation of the Tosoh Bioscience 25OH vitamin D assay
Methods to Detect Red Cell Membrane Disorders
WCC12-ABS-1469 P751 Influence of the concentration and molecular composition on the LDL and HDL functional characteristics in patients with the metabolic.
Copyright © 2012 American Medical Association. All rights reserved.
Classification of total cholesterol levels
A Blend of Sesame and Rice Bran Oils Lowers Hyperglycemia and Improves the Lipids  Sankar Devarajan, PhD, Biprabuddha Chatterjee, MSc, Hidenori Urata,
Practical clinical chemistry
A Blend of Sesame and Rice Bran Oils Lowers Hyperglycemia and Improves the Lipids  Sankar Devarajan, PhD, Biprabuddha Chatterjee, MSc, Hidenori Urata,
KDOQI Clinical Practice Guideline for Diabetes and CKD: 2012 Update
Omega-3 carboxylic acids in patients with severe hypertriglyceridemia: EVOLVE II, a randomized, placebo-controlled trial  Erik S.G. Stroes, MD, PhD, Andrey.
Quality Assurance Reference Intervals.
Practical Hematology Lab Osmotic Fragility Test
Method Selection and Evaluation
Quality Control Lecture 3
Influence of low-glucose peritoneal dialysis on serum lipids and apolipoproteins in the IMPENDIA/EDEN trials  Allan D. Sniderman, MD, James A. Sloand,
Quality Assessment The goal of laboratory analysis is to provide the accurate, reliable and timeliness result Quality assurance The overall program that.
Practical Hematology Lab Osmotic Fragility Test
Practical Hematology Lab Osmotic Fragility Test
III. Treating dyslipidemias
Practical Blood Bank Lab 11 Cyroglobulin.
FIGURE 1 Results for primary meta-analysis of controlled trials for the effects of walnut-enriched compared with ... FIGURE 1 Results for primary meta-analysis.
AEROSET® & ARCHITECT® c8000® OEM Reagent Training
Presentation transcript:

© Copyright 2009 by the American Association for Clinical Chemistry Seven Direct Methods for Measuring HDL and LDL Cholesterol Compared with Ultracentrifugation Reference Measurement Procedures W. Greg Miller, G. L. Myers, I. Sakurabayashi, L. M. Bachmann, S. P. Caudill, A. Dziekonski, S. Edwards, M. M. Kimberly, W. J. Korzun, E. T. Leary, K. Nakajima, M. Nakamura, G. Nilsson, R. D. Shamburek, G. W. Vetrovec,G. R. Warnick, and A. T. Remaley June © Copyright 2010 by the American Association for Clinical Chemistry Journal Club

© Copyright 2009 by the American Association for Clinical Chemistry Introduction  The objective was to evaluate the performance of direct (homogeneous) methods for measurement of HDL Cholesterol (HDL-C) and LDL Cholesterol (LDL-C) for the following characteristics: Trueness of calibration traceability to the reference measurement procedures Accuracy of individual sample measurements Imprecision of the measurement procedures Specificity for the lipoproteins intended to be measured

© Copyright 2009 by the American Association for Clinical Chemistry Introduction (cont)  Challenges for Direct HDL-C and LDL-C Methods Measure the same lipoprotein fractions that are measured by HDL-C and LDL-C reference measurement procedures (RMPs) Not measure anything else Measure accurately for a wide range of clinical conditions with lipoprotein and other metabolic abnormalities

© Copyright 2009 by the American Association for Clinical Chemistry Question  What experimental design will ensure the performance of different direct methods will be evaluated correctly?

© Copyright 2009 by the American Association for Clinical Chemistry Materials and Methods  Reference Measurement Procedures Performed at the CDC Ultracentrifugation of serum Density >1.006 g/mL “bottom fraction” Cholesterol measured by Abell-Kendall (AK) RMP HDL was isolated by heparin manganese precipitation of apo-B lipoproteins (includes LDL fractions) HDL-C measured in supernatant by AK RMP LDL-C calculated as difference between bottom fraction cholesterol and HDL-C (beta-quantification)

© Copyright 2009 by the American Association for Clinical Chemistry Materials and Methods (cont)  Direct measurement procedures Reagent formulations from 7 primary manufacturers that are distributed worldwide under various trade names Performed simultaneously with a Roche Hitachi 917 analyzer using reaction parameters, calibrators, and controls provided by each reagent manufacturer Four frozen serum pools provided by the Centers for Disease Control and Prevention (CDC) were measured at the beginning and end of each run for each method

© Copyright 2009 by the American Association for Clinical Chemistry Materials and Methods (cont)  Sample collection and measurements Blood was collected at Virginia Commonwealth University (VCU) and the National Institutes of Health Plain glass tubes, clotted minutes at room temperature, centrifuged to recover serum Serum aliquots were stored at 4 ºC until measured Shipped overnight on cold packs to CDC and VCU Direct methods (at VCU) and reference methods (at CDC) were performed on the same day within hours of blood collection

© Copyright 2009 by the American Association for Clinical Chemistry Question  What kinds of patients need to be included to determine if the direct methods are fit for their intended purpose?

© Copyright 2009 by the American Association for Clinical Chemistry Participant Characteristics

© Copyright 2009 by the American Association for Clinical Chemistry Figure 1. Box and whisker plot of the differences in percent between the direct and RMP results for HDL-C for each direct method (abbreviations: D is diseased group, N is non-diseased group, De is Denka, Ky is Kyowa, Ro is Roche, Sr is Serotek, Sk is Sekisui, Sy is Sysmex, Um is UMA, Wa is Wako). The median is the center line, the ends of the box represent 25th and 75th percentiles, the end of the lines extend to the 10th and 90th percentiles and individual results are shown beyond the lines. Results

© Copyright 2009 by the American Association for Clinical Chemistry Figure 2. Box and whisker plot of the differences in percent between the direct and RMP results for LDL-C for each direct method (same abbreviations as in Figure 1). The median is the center line, the ends of the box represent 25th and 75th percentiles, the end of the lines extend to the 10th and 90th percentiles and individual results are shown beyond the lines. Results

© Copyright 2009 by the American Association for Clinical Chemistry Question  How can the major measurement error components that contribute to total error be determined?

© Copyright 2009 by the American Association for Clinical Chemistry Error Component Analysis Possible error components were fit to the following model for ln(concentration): y is the measured value µ is the expected value with the RMP The other factors are error components determined from different aspects of the experimental design and explained briefly in the following tables (see supplemental data for details)

© Copyright 2009 by the American Association for Clinical Chemistry Table 1. Error Components for HDL-C Method CV b, %, interassay, frozen pools CV e, %, intraassay, patient samples CV d, %, patient sample-specific effects CV tot, %, combined random effects of CV b, CV e, CV d Mean bias, % % of results outside of upper and lower TE limits HDL-C, nondiseased group Denka Kyowa Roche −2.4−10.4 Sekisui −1.7−8.2 Serotec −4.8−13.4 Sysmex −5.4−10.9 UMA Wako HDL-C, diseased group Denka Kyowa Roche −3.1−17.5 Sekisui −5.2−16.0 Serotec −3.0−18.9 Sysmex −8.6−19.8 UMA − Wako

© Copyright 2009 by the American Association for Clinical Chemistry Table 2. Error Components for LDL-C Method CV b, %, interassay, frozen pools CV e, %, intraassay, patient samples CV d, %, patient sample-specific effects CV tot, %, combined random effects of CV b, CV e, CV d Mean bias, % % of results outside of upper and lower TE limits LDL-C, nondiseased group Denka Kyowa −1.1−7.5 Roche −6.8−13.3 Sekisui −0.7−8.8 Serotec −6.2−11.9 Sysmex −6.0−13.3 UMA − Wako LDL-C, diseased group Denka − Kyowa − Roche −6.3−23.3 Sekisui −1.7−13.5 Serotec −11.8−26.6 Sysmex −7.8−25.9 UMA − Wako

© Copyright 2009 by the American Association for Clinical Chemistry Discussion  For Non-Diseased Patients: 6 out of 8 HDLC methods met the National Cholesterol Education Program (NCEP) total error goal of results within 13% of the RMP (see paper for criteria for concentrations <42 mg/dL) 5 out of 8 LDLC methods met the NCEP total error goal of results within 12% of the RMP  For Diseased Patients: None of the HDL-C and LDL-C methods met the NCEP total error goals

© Copyright 2009 by the American Association for Clinical Chemistry Discussion (cont)  Examination of Error Components Showed: Measurement inter- and intra-assay imprecision was good (CVs <2.8%) for all methods Sample specific effects dominated the random error components in 6 out of 8 HDL-C and LDL-C methods for the non-diseased group Sample specific effects dominated the random error components in all HDL-C and LDL-C methods for the diseased group Sample specific effects were much larger for the diseased than for the non-diseased groups

© Copyright 2009 by the American Association for Clinical Chemistry Question  What causes sample specific effects in direct HDL-C and LDL-C measurements?

© Copyright 2009 by the American Association for Clinical Chemistry Sample Specific Effects May Be Caused By:  Any component in the serum that influences the specificity of the reagents for the HDL-C or LDL-C range of lipoprotein particles: Increased, or decreased, amount of a lipoprotein relative to the distribution of lipoproteins present in non- diseased conditions Increased amount of a lipoprotein normally not present, or present in very low concentration, in non-diseased conditions Presence of a protein or other molecule that alters the reagent’s ability to segregate the HDL or LDL lipoproteins for measurement of cholesterol content

© Copyright 2009 by the American Association for Clinical Chemistry Discussion (cont)  Examination of Error Components Showed: Mean bias exceeded the NCEP 5% goal for 3 out of 8 HDL-C methods (diseased group) Mean bias exceeded the NCEP 4% goal for 3 out of 8 LDL-C methods (both non-diseased and diseased groups)  Bias was Correlated with Triglycerides (TG) Concentration (see Paper for Details) TG reflects abnormalities in lipoprotein composition that may influence the specificity of direct methods

© Copyright 2009 by the American Association for Clinical Chemistry Conclusions  The direct methods performed reasonably well for the non-diseased group  All direct methods had unacceptable total error for the diseased group  Inadequate specificity for the lipoprotein fractions measured by the RMPs was a major limitation  TG concentration may be a surrogate for the presence of abnormal lipoproteins that may influence direct methods

© Copyright 2009 by the American Association for Clinical Chemistry Conclusions (cont)  In many cases the differences between the direct method results and RMPs were sufficiently large that they could affect the clinical management of patients  Several patients with a genetic disorder in lipid metabolism had direct method results that differed so markedly from the RMPs that they could have been misdiagnosed  Inquiries regarding discrepancies between direct method results and clinical observations should be followed up with an ultracentrifugation method