Run II Status Keith Gollwitzer Temple Review July 1, 2003.

Slides:



Advertisements
Similar presentations
Electron Cooling in the Accumulator McGinnis Electron Cooling in the Accumulator Dave McGinnis.
Advertisements

1 Proton Upgrades at Fermilab Robert Zwaska Fermilab March 12, 2007 Midwest Accelerator Physics Collaboration Meeting Indiana University Cyclotron Facility.
Run 2 PMG 2/16/06 - McGinnis Run II PMG Stacking Rapid Response Team Report Dave McGinnis February 16, 2006.
Run II Status and Prospects - Spalding1 Run II Status and Prospects Jeff Spalding Fermilab June 14, 2004.
Re-commissioning the Recycler Storage Ring at Fermilab Martin Murphy, Fermilab Presented August 10, 2012 at SLAC National Laboratory for the Workshop on.
NOvA meeting PIP Update W. Pellico. PIP Goals and Scope (Provided in 2011 – Directorate S. H. / DOE Talk ) Goals: Specific to the issues surrounding the.
Paul Derwent 30 Nov 00 1 The Fermilab Accelerator Complex o Series of presentations  Overview of FNAL Accelerator Complex  Antiprotons: Stochastic Cooling.
F UEC - 6 Oct 06 Recent FNAL Collider Operations Ron Moore Fermilab – Tevatron Dept.
F All Experimenters' Mtg - 9 Jun 03 Week in Review: 06/02/03 –06/09/03 Keith Gollwitzer – FNAL Stores and Operations Summary Standard Plots.
Proton Plan PMG 3/22/07 E Prebys 1 Proton Plan Status February Eric Prebys.
Commissioning of the Fermilab Accelerators for NuMI Operation Robert Zwaska University of Texas at Austin NBI 2003 November 7, 2003.
F MI High Power Operation and Future Plans Ioanis Kourbanis (presented by Bruce Brown) HB2008 August 25, 2008.
Antiproton Source Capabilities and Issues Keith Gollwitzer & Valeri Lebedev Accelerator Division Fermilab 1.
August 05, Startup 2013 Machine Status:  Proton Source Commissioning and Studies RFQ Injector Line (RIL) Linac Booster  Main Injector Startup.
INTRODUCTION  RECYCLER BPM – Original system not adequate to measure beam position precisely. It is being upgraded to meet the required physics precision.
SNuMI (>1MW) SNuMI 1 Motivations for SNuMI The neutrino experimental program for the next decade –NOνA (long baseline νμ→νe search) –MINERνA (Main Injector.
Recycler Status and Plans Shekhar Mishra MID/Beams Division Fermilab AAC Review 2/4/03 Introduction to the Recycler Ring Recycler Improvements and status.
F Antiproton Source Apertures Steve Werkema DOE Tevatron Operations Review March 22, 2006.
Run II PMG 2/16/06 Martens/Sims 1 Run II Upgrades Status February 2006.
AAC February 4-6, 2003 Protons on Target Ioanis Kourbanis MI/Beams.
Dog( leg )s of War Eric Prebys Run II Meeting March 13, 2003.
Proton Study Meeting 4/19/05 Eric Prebys 1 Proton Plan Stage I Eric Prebys.
F All Experimenters' Mtg - 28 Jul 03 Week in Review: 07/21/03 –07/28/03 Keith Gollwitzer – FNAL Stores and Operations Summary Standard Plots.
F 19 August 2002 All Experimenters Meeting Beams Week in Review Continued to work on providing Luminosity L  N p N a /  –Stacking rate –Coalescing efficiency.
F 1 MW Proton Beam for Neutrinos Dave McGinnis AAC Meeting May 10, 2006.
F Proton Plan Eric Prebys, FNAL Accelerator Division.
Run II Operational Status and Plans Run II Meeting October 28, 2004 Dave McGinnis.
All Experimenters' Mtg - Aug. 04, 2003 Week in Review: 07/28/03 –08/03/03 Doug Moehs – FNAL Stores and Operations Summary Standard Plots.
S. Pordes - to part of CD 09/10/031 Introduction to some Beams Division jargon in some order…see how far we get:
Accelerator Issues Fermilab Antiproton Experiment Keith Gollwitzer Antiproton Source Department Accelerator Division Fermilab.
F All Experimenters' Mtg - 03 Mar 03 Week in Review: 02/24/03 –03/02/03 Ron Moore – FNAL Store Summary / What went wrong Tev Studies Highlights Tev Ground.
AP2 Line & Debuncher Studies Status Keith Gollwitzer Antiproton Source January 9, 2006 Many people involved with providing the hardware and software that.
Proton Plan PMG 9/27/07 E Prebys 1 Proton Plan Status Eric Prebys.
F All Experimenters' Mtg - 2 Jun 03 Weeks in Review: 05/19/03 –06/02/03 Keith Gollwitzer – FNAL Stores and Operations Summary Standard Plots.
Recent Work Towards Increasing the AP2 & Debuncher Aperture – Keith Gollwitzer – May 9, Recent Work Towards Increasing the AP2 & Debuncher Aperture.
Fermilab Run 2 Accelerator Status and Upgrades
Updated Overview of Run II Upgrade Plan Beam Instrumentation Bob Webber Run II Luminosity Upgrade Review February 2004.
What’s Up in the Booster Eric Prebys February 27, 2002 and March 6, 2003.
Proton Planning – Major Projects, Schedule, Decisions, and Projections Eric Prebys FNAL Accelerator Division.
Doug Michael Sep. 16, GeV protons 1.9 second cycle time 4x10 13 protons/pulse 0.4 MW! Single turn extraction (10  s) 4x10 20 protons/year 700.
Proton Plan Expectations Eric Prebys AD/Proton Source.
Run II PMG 1/19/06 Pushpa Bhat 1 Run II Upgrades Status January 2006 Pushpa Bhat.
Status of the AP2 Optics Keith Gollwitzer Antiproton Source Department November 19, 2004.
Proton Plan PMG 2/22/07 E Prebys 1 Proton Plan Status January Eric Prebys.
The Introduction to CSNS Accelerators Oct. 5, 2010 Sheng Wang AP group, Accelerator Centre,IHEP, CAS.
Status of the Accelerator Complex Keith Gollwitzer Antiproton Source Accelerator Division Fermilab 2009 Fermilab Users’ Meeting.
High Intensity Booster Operations William Pellico PIP II collaboration Nov. 9 th 2015.
Users' Mtg - 4 Jun 08 FNAL Accelerator Complex Status Ron Moore Fermilab – AD / Tevatron Dept.
SNuMI: WBS 1.1 Booster Upgrades Eric Prebys $642K FY06$ (no contingency, no G&A) xx% contingency Main Injector & Recycler BNB NuMI Tunnel Booster Ring.
Proton Planning Eric Prebys FNAL Accelerator Division.
F Record luminosities at the Tevatron & Future potentiality Steve Werkema Fermi National Accelerator Laboratory Batavia, Illinois USA Asian Particle Accelerator.
F All Experimenters' Mtg - 24 Feb 03 Week in Review: 02/17/03 –02/23/03 Ron Moore – FNAL Store Summary Failed Tev dipole disassembly Schedule for Week.
F Possible Proton Capabilities at Fermilab Dave McGinnis April 16, 2007.
Robert R. Wilson Prize Talk John Peoples April APS Meeting: February 14,
Overview of Ramp Development Giulio Stancari E-835 Collaboration Meeting Torino, May
F HCP 2007 Performance and Future of the Tevatron Ron Moore Fermilab - Tevatron Dept. Tevatron overview and performance Antiproton source + Recycler overview.
Proton Plan PMG 4/18/05 E Prebys/J. Sims 1 Proton Plan Status March Report Eric Prebys Jeff Sims.
August 12, Machine Status: 2013  Proton Source Commissioning and Studies RFQ Injector Line (RIL) Linac : Roof hatch installed Booster : Magnet.
F All Experimenters' Mtg - 6 Jan 03 Week in Review: 12/30/02 –1/05/03 Ron Moore – FNAL Store Summary – Best week! > 7 pb -1 Machine Studies/Maintenance.
PAC Meeting, December 12, Prebys 1 The Problem.
Pbar Production Status & Plans to get to 25mA/hr Keith Gollwitzer Antiproton Source August 31, 2006.
Limitations to Total Booster Flux Total protons per batch: 4E12 with decent beam loss, 5E12 max. Average rep rate of the machine: –Injection bump magnets.
F Project X: Recycler 8.9 GeV/c Extraction D. Johnson, E. Prebys, M. Martens, J. Johnstone Fermilab Accelerator Advisory Committee August 8, 2007 D. Johnson.
MI/RR Operation Status Ioanis Kourbanis August 21, 2014.
Antiproton Acceptance Steve Werkema DOE Review February 24, 2004.
AGS FY11 Summary RHIC Spin Collaboration Meeting 5/6/11.
Weekly Pbar Report 10/26 → 11/2. Stacking This Week …
Proton Economics Eric Prebys FNAL Accelerator Division.
Pre-Meeting Meeting Brian Drendel Accelerator Shift Plot.
LHC (SSC) Byung Yunn CASA.
Presentation transcript:

Run II Status Keith Gollwitzer Temple Review July 1, 2003

Run II Status - Gollwitzer 2 Status on Luminosity Parameters

Run II Status - Gollwitzer 3 Beam Intensity during Shot Booster can produce adequate # protons for Tevatron Run II intensity goals Accumulator can produce (almost) adequate # antiprotons for FY03 luminosity goals Emittance growth produces poor efficiencies

Run II Status - Gollwitzer 4 Proton Source Issues -Proton Source has increased throughput over the last year (see slides). With the Main Injector, the Proton Source delivers 5e12 proton to the antiproton production target routinely while providing beam to MiniBooNE. -Dogleg reduction (improved performance to date mostly due to this). Plans to further reduce one dogleg during shutdown (see slides). This has the greatest potential for Booster improvement. -Collimators to be installed this shutdown. This should remove largest radiation loss from Booster ring proper. Next limits are expected to be injection and extraction areas MeV Lambertson installation during next shutdown. The better designed and larger injection aperture will allow better tuning of Linac and reduce losses. -EDWA magnet installation during next shutdown. Currently at intensity limit before tripping radiation monitors. Larger aperture at extraction will eliminate loss point.

Run II Status - Gollwitzer 5 Proton Source Performance Number of beam pulses in a day Days ( 0 = Jun 26, ‘03 ) 3.5Hz

Run II Status - Gollwitzer 6 Proton Source Performance Recent stacking performance. Also providing >4E16 protons/hour to MiniBooNE Protons on production target Antiproton production/proton Antiproton beam current Stacking Rate 1e Plot is over 40hr period

Run II Status - Gollwitzer 7 Booster Dogleg Each of the two Booster extraction septa has a set of vertical dogleg magnets to steer the beam around it during acceleration. More powerful doglegs were installed in 1998 to reduce losses early in the cycle. These magnets have an edge focusing effect which distorts the horizontal injection lattice: 50% increase in maximum  100% increase in maximum dispersion. Harmonic contributions. Effect goes like I 2. Now tune to minimize. Recently got an unusual opportunity to explore potential improvements from fixing the problem. Working on schemes to reduce or remove problem. (from E. Prebys) Septum Dogleg Magnets

Run II Status - Gollwitzer 8 Booster Dogleg (continued) xx DxDx Ideal Lattice Add Doglegs (from E. Prebys)

Run II Status - Gollwitzer 9 Antiproton Source Issues Since the Fall, several small incremental changes have enhanced stacking rate and quality of antiproton beam delivered. Stack rate falls with stack size (see slide). Stack rate limited by Debuncher momentum cooling (see slide). New equalizers to be installed during shutdown. Core transverse emittances during shots are adequate to meet Run II goals for stack sizes up to ~250E10 (see slide) Average longitudinal emittance for shots is 1.1 eV-sec/bunch (measured on AP1 wall current monitor). This should be good enough for 3 eV-sec at low beta. (see slide) Best stacking rate is 13.5 E10 for 1 hour. Average stacking rate is ~7.5 E10/hr.

Run II Status - Gollwitzer 10 Antiproton Stacking 20 Antiproton produced per 10e6 on target Stacking Rate (mA/hr) 10 Data are from the last 12 weeks Largest Stack to Date 236mA Stack Size (mA)

Run II Status - Gollwitzer 11 Debuncher Momentum Cooling Stacking upgrades - Major emphasis has been on Debuncher momentum cooling, stacktail cooling system, and yield into Debuncher (AP2 and target). from P. Derwent Time (s) 95% Mom. Width (MeV/c)

Run II Status - Gollwitzer 12 Antiproton Transverse Emittance from J. Morgan Stores since Apr02 Emittance (pi-mm-mr)

Run II Status - Gollwitzer 13 Antiproton Longitudinal Emittance AP1 wall current monitor for a pbar transfer

Run II Status - Gollwitzer 14 Main Injector Issues Beam-loading compensation on ramps: Study has shown that BLC during stacking ramp helps beam quality on target. Should provide help with ramping antiprotons. Longitudinal Dampers: Instability is a problem on ramping protons to 150GeV. Cavities are ready for installation, but will take 3 days for installation. One of two amplifiers has been delivered. This should help with all efficiencies (coalescing, transfer to TeV, 150GeV TeV lifetime, and ramp). Transverse injection dampers should reduce emittance growth ~1 pi for protons, 1-2 pi for pbars. Commissioning has just started. Other on-going studies: 2.5 MHz acceleration; slip stacking; multi-batching for NUMI; SY120

Run II Status - Gollwitzer 15 Main Injector Beam Loading Compensation Intensity Length Phase Coupled bunch mode Bunch Without BLC With BLC 2020 ns degrees

Run II Status - Gollwitzer 16 Tevatron Issues P150 transfers cause emittance blowup of >4  mm-mr. A150 transfers cause emittance blowup of >6  mm-mr. Transverse 150 GeV allow lower chromaticity, better lifetime; not yet commissioned on ramp – excessive local coupling makes commissioning on ramp difficult. Coupling -- major source identified; will start correcting this shutdown (see slides); impact on Tevatron performance not known. C0 Lambertson removed in January. The immediate impact was a change in machine impedance which allowed more protons. Study time is required to commission new helix (already modified orbit to improve aperture); main hope is to improve 150 GeV and reduce losses at beginning of ramp. Now the major transverse impedance is from F0 Lamb laminations (see slide). Will install liner during shutdown. Octupoles for stabilization – some studies done; no estimate for completion; limited studies so far indicate this can help 150 GeV Injection dampers should improve proton emittance by ~1  mm-mr; pbar emittance by ~2  mm-mr; waiting for power amplifiers to arrive. Alignment – There is a tentative shutdown proposal; will be reviewed early July.

Run II Status - Gollwitzer 17 Tevatron coupling Coupling in Tevatron is ~uniform around the ring and is consistent with ~1.5 units of a 1 per dipole. This is compensated by a distributed skew quad circuit of 42 elements. Data shows in-plane and out-of-plane difference orbits after single horizontal kick. Data is for 1 st 5 turns in Tevatron. from M. Syphers

Run II Status - Gollwitzer 18 Tevatron coupling (continued) Tevatron dipole cross section Tevatron coil and cryostat assembly is held within the iron by 4 supports at 9 locations along the length of the magnet. Recent measurements of the “smart bolts” (upper supports) on 18 magnets in the tunnel, indicate that the coil assembly has sagged by ~2 mils from original. This is enough to produce ~1 unit of a1 per dipole. In 1984, compensating skew quad circuit was running at ~2A. From 1995 compensating skew quad circuit has been running at ~24A 800 GeV). from P. Bauer

Run II Status - Gollwitzer 19 Tevatron F0 Lambertson 1 is Injection Orbit 2 is Central Orbit 3 is Local Orbit Bump from P. Ivanov For each orbit, the instability thresholds as functions of H & V chromaticities Will install thin inner liner with high electrical conductivity and high thermal conductivity {Cu-Be bronze C17200: Be 1.9%, Co 0.2%, Cu 97.9 %}

Run II Status - Gollwitzer 20 Recycler Commissioning - Prior to January shutdown beam lifetime was >100 hours, with equilibrium emittance of ~7  -mm-mrad and ~75 eV-sec with 70E10 antiprotons. - During the shutdown the number of ion pumps was doubled in ~3/4 of the ring, ~20% of the ring was baked, and additional instrumentation was added. -Since the shutdown the beam lifetime has been ~3 times worse, and the emittance growth rate ~3 times faster. Contaminated vacuum is thought to be the culprit. -Some instrumentation and beam pipe will be removed and those sections will be re-baked in order to recover (at least) the previous vacuum. -Stochastic cooling systems have been commissioned; transverse emittance monitor has been commissioned; beam line tuner has been commissioned -New BPM system is being built and commissioned; it is scheduled for completion of installation by Summer shutdown. -Ramped correctors have been commissioned – horizontal orbit distortions due to MI ramps have been reduced to <.3mm rms.

Run II Status - Gollwitzer 21 Agenda for FY03 Maximize luminosity between now and August 25 - Dedicated studies limited due to the need to reach 225 pb -1 for FY03; studies are almost entirely “maintenance” 7 week shutdown starting August 25 - Recycler vacuum; e-cooling civil construction; Tevatron F0 Lambertson modification; Tevatron Tevatron alignment; additional shielding for CDF detector; Debuncher movable quad installation; AP2 aperture increase; Booster dogleg modification; NUMI installation work; infrastructure maintenance (full scope of work not yet determined)….

Run II Status - Gollwitzer 22 Summary Factor of 2.3 increase in peak luminosity over last 12 months Factor of 2.3 increase in weekly integrated luminosity over last 12 months Progress on instrumentation Improvements in theoretical understanding of issues Summer shutdown projects should lead to additional luminosity increases