Summary of LOIs to INTC (24 June 2010). Call for Letters of Intent (deadline May 21) 34 Letters submitted 284 Participants from 76 Laboratories in 22.

Slides:



Advertisements
Similar presentations
SYNTHESIS OF SUPER HEAVY ELEMENTS
Advertisements

Neutron detectors and spectrometers 1) Complicated reactions → strong dependency of efficiency on energy 2) Small efficiency → necessity of large volumes.
4/29/20151Cosenors - BentleyOverview Physics of Proton-rich Nuclei in the UK Mike Bentley (Univ. of York, UK) Physics of Proton-rich Nuclei in the UK Mike.
Γ spectroscopy of neutron-rich 95,96 Rb nuclei by the incomplete fusion reaction of 94 Kr on 7 Li Simone Bottoni University of Milan Mini Workshop 1°-
HIE-ISOLDE HEBT: characteristics Beamline diameter: 40 mm (REX: 100 mm) Beamline height: 1.75 m Beamline vacuum: low 1e-7- high 1e-8 mbar Connection of.
An Association of Florida State University Accelerator Lab Hope College Ion Beam Laboratory Ohio University Accelerator Lab Texas A&M Cyclotron Lab TUNL.
LLNL-PRES-?????? This work was performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under contract DE-AC52-07NA27344.
Potential of Cyclotrons
JYFLTRAP: Spectroscopy with multi-trap facility Facility Mass purified beams In-trap spectroscopy Future plans.
S. Sidorchuk (JINR, Dubna) Dubna Radioacive Ion Beams DRIBsIII: STATUS and PROSPECTS S. Sidorchuk (JINR, Dubna) 9-16 May 2013, Varna, Bulgaria 1.
Status of the External Solenoidal Spectrometer for the TSR Robert Page Why an external spectrometer? Solenoidal spectrometer Baseline design parameters.
Direct Reactions at Eurisol In the light of the TIARA+MUST2 campaign at GANIL B. Fernández-Domínguez.
Direct Reactions at Eurisol In the light of the TIARA+MUST2 campaign at GANIL B. Fernández-Domínguez.
Coulomb excitation and  -decay studies at (REX-)ISOLDE around Z = 28 J. Van de Walle – KVI - Groningen 1. ISOLDE and REX-ISOLDE ; 2. Results around Z=28.
Status of EURISOL Yorick BLUMENFELD We acknowledge the financial support of the European Community under the FP6 “Research Infrastructure Action - Structuring.
Darsebury June - Lolly ACTAR. Darsebury June - Lolly Si – TOF/ Active Target Si - PSD Si – DE-E Si/CsI - Tracking SPIRAL2 NuStar A 50 keV.
1107 Series of related experiments; first for transfer with TIGRESS Nuclear structure motivation for 25,27 Na beams Nuclear astrophysics motivation for.
Spectrometer Workshop 10/3 – 11/3 Lund University.
Neutron Generation and Detection Lee Robertson Instrument & Source Division Oak Ridge National Laboratory 17 th National School on Neutron and X-ray Scattering.
XXXVIII th Rencontres de Moriond MORIOND WORKSHOP ON Radioactive beams for nuclear physics and neutrino physics Acceleration of RIB using cyclotrons Guido.
A facility for Nuclear, Atomic, Material and Radiobiology Sciences. Delivering stable (from C to U) and radioactive ions (from He to Xe) in the energy.
N. Saito The RISING stopped beam physics meeting Technical status of RISING at GSI N. Saito - GSI for the RISING collaboration Introduction Detector performance.
Noyaux CERN- ISOLDE Yorick Blumenfeld.
Applications of neutron spectrometry Neutron sources: 1) Reactors 2) Usage of reactions 3) Spallation sources Neutron show: 1) Where atoms are (structure)
Direct Reactions with ORRUBA and GRETINA Steven D. Pain Oak Ridge National Laboratory GRETINA Workshop, ANL, February 2013.
Nuclear physics: the ISOLDE facility
Lawrence Livermore National Laboratory Nicholas Scielzo Lawrence Fellow Physics Division, Physical Sciences LLNL-PRES Lawrence Livermore National.
Radioactive ion beam facilities How does they work ? 2012 Student Practice in JINR Fields of Research 9.oct.2012 I. Sivacekflerovlab.jinr.ru.
The Belgian Research Initiative on eXotic nuclei – BriX network BriX Days Liege, May 27-28, 2015 Funded by the Interuniversity Attraction Poles Programme.
PH Dept News Long shutdown 1: Baseline Project Project Leader Freddy Bordry Injector shutdown Dec 2012-Mar 2014 means 1 year stop for ISOLDE Physics LS2.
CRYOMODULES High Beta Low Beta Approved by CERN Research Board in December 2009.
Neutron inelastic scattering measurements at the GELINA facility of EC-JRC-IRMM A. Negret 1, C. Borcea 1, A. Plompen 2 1 NIPNE-HH, Romania 2 EC-JRC-IRMM,
Fundamental Interactions Physics & Instrumentation Conclusions Conveners: P. Mueller, J. Clark G. Savard, N. Scielzo.
UNIVERSITY OF JYVÄSKYLÄ RDDS measurements at RITU and prospects at HIE-ISOLDE T. Grahn University of Jyväskylä HIE-ISOLDE Spectrometer Workshop, Lund
I. Introductory remarks and present status II. Laboratory experiments and astrophysics III. Future options scenarios status and challenges new developments.
LLNL-PRES This work was performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under contract DE-AC52-07NA27344.
European Isotope Separation On-Line Radioactive Nuclear Beam Facility A preliminary design study of the next- generation European ISOL RNB facility GANIL,
I. MARTEL SGFDC UNIVERSITY OF HUELVA JULY 2007 Collaboration: University of Huelva, Spain (coordinator) GSI-Darmstadt, Germany. University of.
Status Report of the LISOL Laser Ion Source Yu.Kudryavtsev, T.Cocolios, M.Facina, J.Gentens, M.Huyse, O.Ivanov, D.Pauwels, M.Sawicka, P.Van den Bergh,
Radioactive Ion Beams CW 0.5 MW (for protons) 1 GeV (for protons) p to U Chiara, Manuel, Adam, HuiMay 2011, CAS, Bilbao.
Proton Source & Site Layout Keith Gollwitzer Accelerator Division Fermi National Accelerator Laboratory Muon Accelerator Program Review Fermilab, August.
Nuclear Astrophysics ARUNA Workshop, Notre Dame, IN Carl R. Brune Ohio University, Athens Ohio June 12-13, 2014.
ISOLDE Physics Report Magdalena Kowalska. Injector schedule since last meeting 2 September: confirmation of 2 more weeks with protons – until December.
Maria J. G. Borge Beam Lines for HIE-ISOLDE. Status of HIE-ISOLDE 2 May 2010: 34 LoI submitted 1 Nov 2012: INTC endorsed the increase of 2 GeV-proton.
REQUIREMENTS for Zero-Degree Ion Selection in TRANSFER Wilton Catford University of Surrey, UK & SHARC collabs.
Observation of new neutron-deficient multinucleon transfer reactions
Riccardo Raabe (IKS, KU Leuven) for the Collaboration INTC 01/02/2012 INTC-O-014 Storage ring facility at HIE-ISOLDE: Technical Design Report.
HYSPEC IDT HYSPEC: Our Instrument at the Spallation Neutron Source. Outline Spallation Neutron Source (SNS) and the BNL Overview of the SNS instrument.
Nuclear physics: the ISOLDE facility Magdalena Kowalska CERN, PH-Dept. on behalf of the CERN ISOLDE team Lecture 2:
A HIE-ISOLDE spectrometer for nuclear reaction studies G. Tveten 1, J. Cederkall 2, S. Siem 1, A. Goergen 1, M. Guttormsen 1, P. Hoff 1, D. Di Julio 2,
Proposal for the End Station Test Beam (ESTB) at SLAC John Jaros ALCPG09 Albuquerque September 30, 2009.
Summary: Physics Opportunities for ISOLDE and n_TOF Peter Butler.
Development of Cryogenic Moderators Using a Small Proton Accelerator Yoshiaki Kiyanagi*, Fujio Hiraga, Takashi Kamiyama, Akira Homma, Fumiyuki Fujita and.
A Compact FFAG for Radioisotope Production D. Bruton R. Barlow, R. Edgecock, and C.J. Johnstone.
Status and Future Perspective of the HIE-ISOLDE Project CERN, November 19-20, 2012
UK Neutrino Factory Conceptual Design
Lecture at the MEDICIS-PROMED Summer School
In-source laser spectroscopy of mercury isotopes (P-424)
PH Department News Discussion with management
Current topics in Nuclear Structure
the s process: messages from stellar He burning
Diagnostics of FRIBs beam transport line
First results from IS468 and further investigation of in-trap decay of 62Mn First results from 2008 ; Problems and questions ; Further investigations ;
Actinide Transfer-Induced Fission In Inverse Kinematics with ISS
The neutron capture cross section of the s-process branch point 63Ni
Presentation of the thematics P3 Michel Guidal (IPNO)
End Station Test Beam (ESTB) at SLAC
Study of the resonance states in 27P by using
INTC matters . Magdalena Kowalska.
Beam Transfer Line Stage 1:
Presentation transcript:

Summary of LOIs to INTC (24 June 2010)

Call for Letters of Intent (deadline May 21) 34 Letters submitted 284 Participants from 76 Laboratories in 22 Countries 30 LOIs make use of the Energy and Intensity increases; 4 of the intensity upgrade only Major mechanisms are Coulex (13) and transfer(16); elastic scattering(3); fission(2) (3) letters concern masses and moments; (4) astrophysics and (5) major new instrumentation Major subjects: Nuclear shapes ; Shell evolution; Halo properties; Nuclear astrophysics

LOI participants by Country

LOI Spokespersons by Country

protons neutrons post-accelerated keV Radioactive isotopes requested in HIE-ISOLDE Letters of Intent SPIRAL 2

Main Instrument : Miniball (+ TREX) Requested by 18 LOIs Beam energy : 5A MeV for COULEX, 10A MeV for transfer Beam spot < 3mm Slow extraction – long beam pulses 9 LOIs need or would benefit from coupling with spectrometer.

Spectrometer Two possible types: Mass separator (EMMA type) or ray-tracing (PRISMA-VAMOS type) No LOI gives any decisive choice. Requirements : EMMA – beam spot < 2mm PRISMA – beam spot < 3mm Dt < 1ns Bunched beam with period 100ns Mass spectrometer Ray-tracing

Other new equipment ACTAR – Space 1.5m x 1.5m – Spread beam pulses – Low energies for astrophysics: <0.7A MeV PARIS – Coupled to T-Rex or Gaspard – Space to be specified – Good beam timing and 100ns bunch period??

Other new equipment (2) Gaspard – Compact; in coincidence with Miniball + spectro or with Paris – Beam spot size= 1mm ! – Sub ns timing; 100ns bunch period Helios – 7 m X 4m – Dt< 1ns; 100ns bunch period

Other experiments Neutron detection : TOF 2 meters. DT = 1ns and bunch period 100 ns MoT trap : 10m m 2 laser table (low energy area) Actinide beams : 2m flight path; up to 10**9 pps I 124 needs Tilted foil holder between 200 keV and 1 MeV/A I 103 mentions Miniball + Bragg counter I 116 mentions PARIS coupled to TOF spectrometer.

Summary Spectrometer is important – There should be a working group set up and space reserved Timing properties are crucial for many experiments: neutrons, PARIS, GASPARD, Helios… DT<1 ns on target; Buncher/chopper necessary Beam spot size < 3mm and better. HELIOS and neutron detection require space. Energy resolution and precision never mentioned Storage ring