Recent Developments in Polymer Characterization And how we may have to modify them for nanoparticles.

Slides:



Advertisements
Similar presentations
Chromatography Components stationary phase (eg., solid matrix) mobile phase (eg., solvent) solute Solutes which interact differently with the stationary.
Advertisements

They were young when GPC was.. Small Subset of GPC Spare Parts To say nothing of unions, adapters, ferrules, tubing (low pressure and high pressure),
Lecture 17. Light Scattering/Viscometry. What is light scattering? In the lab…
King Saud University Riyadh Saudi Arabia Dr. Gihan Gawish Assistant Professor 1.
Bioseparation Chapter 9
This presentation exemplifies the latest Power Point dogma. 1 A full sentence at the top tells the main point. Vertically aligned lists are avoided in.
Introduction to DYNAMIC LIGHT SCATTERING (DLS) Christer Svanberg or PHOTON CORRELATION SPECTROSCOPY (PCS)
Foundation GPC Part 4 – Organic Gel Permeation Chromatography Columns and Applications.
Size Exclusion Chromatography
Foundation GPC Training Course Theory. Nomenclature Gel Permeation ChromatographyGPC Size Exclusion ChromatographySEC Gel Filtration ChromatographyGFC.
1 HPLC Lecture Mobile Phase Selection in Partition Chromatography Optimization of the mobile phase composition and polarity is vital for obtaining.
Separation of molecules and determination of there molecular weight by gel filtration chromatography. Experiment 7 BCH 333.
The use of light scattering in characterizing lignin.
Optical Tweezers F scatt F grad 1. Velocity autocorrelation function from the Langevin model kinetic property property of equilibrium fluctuations For.
1. 2  A form of “partition chromatography”.  Stationary phase is a porous gelatinous matrix (in the form of beads).  Sample components enter pores.
Advanced GPC Part 1 – GPC and Viscometry
Foundation GPC Part 5 – Polar and Aqueous Gel Permeation Chromatography Columns and Applications.
METO 621 Lesson 5. Natural broadening The line width (full width at half maximum) of the Lorentz profile is the damping parameter, . For an isolated.
Salting out is a method of separating proteins based on the principle that proteins are less soluble at high salt concentrations. The salt concentration.
Protein Purification and Analysis Solubility of proteins important for purification: 60-80% soluble, 20-40% membrane Size of proteins varies Some proteins.
Gel Filtration Chromatography.
1 L U N D U N I V E R S I T Y Methods to determine particle properties Chapter 7.
Unit 2, Part 3: Characterizing Nanostructure Size Dr. Brian Grady-Lecturer
There are many times in nature when a solvent will pass spontaneously through a semipermeable membrane, which is a membrane permeable to solvent, but not.
BETTER THAN SEC’s Paul S. Russo Louisiana State University Texas Polymer Center Freeport, TX October 31, 2001.
An Extended Range of Columns for Aqueous Size Exclusion Chromatography Greg Saunders, Graham Cleaver and Ben MacCreath, Varian, Inc., Church Stretton,
Chemistry 4010 Lab It’s all about PROTEINS… It’s all about PROTEINS…
Recent Advances in DLS and DPI Dave Dolak, Malvern Instruments RAMC 2007, San Diego.
Gel filtration chromatography y/college/voet/ /animat ed_figures/ch05/f5-6.html.
Chapter 4-1 Chromatography
Putting a speed gun on macromolecules: what can we learn from how fast they go, and can we do something useful with that information? Monday, October.
Drs. Wei Tian & Yanhui Chen Sep-Dec Main Content Chromatography Analysis Gas Chromatography (GC) High Performance Liquid Chromatography (HPLC)
ADVANCED BIO-FRIENDLY POLYMERS Igor Lacík Gel permeation chromatography – a tool for determination of molar mass of polymers.
LECTURE 9 CHROMATOGRAPHIC SEPARATIONS The “stuff” you do before you analyze a “complex” sample.
Protein Purification and Analysis Solubility of proteins important for purification: 60-80% soluble, 20-40% membrane Size of proteins varies Some proteins.
Separation Science All separations go against the 2 nd Law of Thermodynamics: entropy increases during any natural process.
1 High Performance Liquid Chromatography (HPLC) Lecture 40.
1. Fast Protein Liquid Chromatography 2 FPLC A semi-automatic microprocessor controlled machine used primarily for the separation of macromolecules A.
Factors affecting electrophoresis The electric field ·       Voltage. If the separation of the electrodes is d (cm) and the potential difference.
History of Chromatography n Early LC carried out in glass columns n diameters: 1-5 cm n lengths: cm n Size of solid stationary phase n diameters:
Chemistry 367L/392N Macromolecular Chemistry Lecture 8.
Proteins separation and analysis using Fast Protein Liquid Chromatography Ayelet David, Ph.D Dept. of Clinical Pharmacology.
Figure 23.1: Comparison between microfluidic and nanofluidic biomolecule separation. (a) In microfluidic device, friction between liquid and the molecule.
Pursuing the initial stages of crystal growth using dynamic light scattering (DLS) and fluorescence correlation spectroscopy (FCS) Takashi Sugiyama Miyasaka.
Cavity ring down spectroscopy 14 February 2012 CE 540.
Mara Levine SURF What we studied  Hard spheres vs soft spheres  Monodisperse vs polydisperse  High packing fraction "Index of /images/scanner_art/."
From Rubinstein & Colby Polymer Physics Here is a nice example of scaling: 3 different types of polymers, all normalized sround the entanglement molecular.
HPLC.
Förster Resonance Energy Transfer (FRET)
--Experimental determinations of radial distribution functions --Potential of Mean Force 1.
Molecular Weight Distribution
1 High Performance Liquid Chromatography (HPLC) Lecture 40.
Membrane Osmometry Alfredo Clemente CH 392N Prof. Grant Willson. The University of Texas Austin.
T.A Nouf Alshareef KAU-Faculty of Science- Biochemistry department Analytical biochemistry lab (Bioc 343) 2012 False colour scanning.
GEL FILTRATION CHROMATOGRAPHY Size Exclusion Chromatography
BY G.SHRAVANI ION EXCHANGE AND GEL PERMEATI ON CHROMATOGRAPHY 1G.SHRAVANI.
Tutorial 09 Overview of other chromatographic methods 1.
Size exclusion Chromatography
Chemistry 367L/392N Macromolecular Chemistry Lecture 10.
High Performance Liquid Chromatography Presented by Dr. Kamal Modi 2 nd Year Resident.
Gel Permeation Chromatography Size Exclusion Chromatography
Chapter 4-3 Chromatography Gel Chromatography Dr Gihan Gawish.
Introduction There are a wide variety of columns available for polar and aqueous GPC This presentation shall introduce the most common types of column.
Gel Filtration Chromatography.
Size Exclusion Chromatography (SEC)
Characterization of SCNPs Summary and Conclusions
Rejection and Mass Transport in Membranes
Light scattering method Introduction: The illumination of dust particles is an illustration of light scattering, not of reflection. Reflection is the deviation.
Gel Filtration Chromatography.
Mageleka MagnoMeter™ XRS
Presentation transcript:

Recent Developments in Polymer Characterization And how we may have to modify them for nanoparticles

Obligatory Equation SEC = GPC = GFC Size Exclusion Chromatography Gel Permeation Chromatography Gel Filtration Chromatography

A riddle After a hurricane, many trees fall over and bend into a river. Also, a cow and a dog fall into a flooded river. Which one reaches the ocean first, cow or dog? Moo! Woof!

GPC Solvent flow carries molecules from left to right; big ones come out first while small ones get caught in the pores. It is thought that particle volume controls the order of elution. But what about shape ?

Simple SEC degas pump injector DRI VeVe log 10 M c c c

Osmometry: Real Science Semipermeable membrane: stops polymers, passes solvent. h  V = n R T n = g/M c = g/V  = c R T

Light Scattering: Osmometer without the membrane 100,000  x c 

LS adds optical effects  Size q = 0 in phase I s maximum q > 0 out of phase, I s goes down

SEC/MALLS degas pump injector DRI MALLS

SEC/MALLS Scattering angle VeVe Scattered intensity

Scattering Envelope for a Single Slice

SEC/MALLS in the Hands of a Real Expert a p  15 nm Much less than PBLG Macromolecules, 29, (1996)

Midpoint The new power of SEC/Something Else experiments is very real. SEC is now a method that even the most skeptical physical chemist should embrace. For example, our results (not shown) favor higher rather than lower values for persistence length of one polymer (PBLG). This helps to settle about 30 years of uncertainty. So, SEC is good enough for physical measurements, but is it still good enough for polymer analysis? What about nanoparticles, especially large ones, in GPC?

They were young when GPC was.

Small Subset of GPC Spare Parts To say nothing of unions, adapters, ferrules, tubing (low pressure and high pressure), filters and their internal parts, frits, degassers, injector spare parts, solvent inlet manifold parts, columns, pre-columns, pressure transducers, sapphire plunger, and on it goes…

Other SEC Deficiencies 0.05 M salt at 10 am, 0.1 M salt at 2 pm? 45 o C at 8 am and 50 o C at noon? Non-size exclusion mechanisms: binding. Big, bulky and slow (typically 30 minutes/sample). Temperature/harsh solvents no fun. You learn nothing by calibrating.

Must we separate ‘em to size ‘em? Your local constabulary probably doesn’t think so. Atlanta, Georgia I-85N at Shallowford Rd. Sat. 1/27/01 4 pm

Sizing by Dynamic Light Scattering — a 1970 ’ s advance in measuring motion, driven by need to measure sizes, esp. for small particles. t IsIs It’s fluctuations again, but now fluctuations over time! DLS diffusion coefficient, inversely proportional to size. Large, slow molecules Small, fast molecules

Molecular Weight Distribution by DLS/Inverse Laplace Transform--B.Chu, C. Wu, &c. Where: G(  ) ~ cMP(qR g )  = q 2 D  q 2 kT/(6  R h ) R h = XR g g(t) log 10 t ILT  q 2 D G(  ) CALIBRATE MAP M c log 10 M log 10 D 

Hot Ben Chu / Chi Wu Example MWD of PTFE Special solvents at ~330 o C Macromolecules, 21, (1988) Problems: Only “works” because MWD is broad Poor resolution. Low M part goofy. Some assumptions required.

Reptation: inspired enormous advances in measuring polymer speed … and predicts More favorable results for polymers in a matrix. T here once was a theorist from France Who wondered how molecules dance. "They're like snakes," he observed, "as they follow a curve, the large ones can hardly advance."* D ~ M -2 deGennes More generally, we could write D ~ M -  where  increases as entanglements strengthen *With apologies to Walter Stockmayer

Matrix Diffusion/Inverse Laplace Transformation Goal: Increase magnitude of  Difficult in DLS because matrix scatters, except special cases. Difficult anyway: dust-free matrix not fun! Still nothing you can do about visibility of small scatterers DOSY not much better Replace DLS with FPR. Selectivity supplied by dye. Matrix = same polymer as analyzed, except no label. No compatibility problems. G(  ) ~ c (sidechain labeling) G(  ) ~ n (end-labeling) log 10 M log 10 D Stretching  Solution:   Matrix:  

Painting Molecules* Makes Life Easier *R. S. Stein Small Angle Neutron Scattering ForcedRayleighScattering Fluorescence Photobleaching Recovery Index-matched DLS match solvent & polymer refractive index can't do in aqueous systems Depolarized DLS works for optically anisotropic probes works for most matrix polymers

Fluorescence Photobleaching Recovery 1. An intense laser pulse photobleaches a striped pattern in the fluorescently tagged sample. 2. A decaying sine wave is produced by moving the illumination pattern over the pattern written into the solution. 3. An exponential decay is produced by monitoring the amplitude of the decaying sine wave. Fitting this curve produces  from which D can be calculated.

FPR for Pullulan (a polysaccharide) Probe Diffusion: Polymer physicsCalibration: polymer analysis

FPR Chromatogram  Indicates targeted M.

GPC vs. FPR for a Nontrivial Case 20,000 & 70,000 Dextran PL Aquagel 40A & 50A User-chosen CONTIN 25% Matrix

 Indicates targeted M.

Examples of Separation Results from Simulation Data  Indicates targeted M.

What about separating cows and elephants? Either will float around the trees. How do you separate them then? Moo! Eeee!

Field Flow Fractionation, that’s how! In FFF, large nanoparticles are made to flow between plates.

One plate is porous, and a cross- flow is arranged.

What happens? Little nanoparticles come out first!

Potential Advantages of FFF Handles a wider range of particles. May be easier for some aggressive solvents.

Conclusion GPC is essential in any Nano Lab GPC may eventually get replaced. Matrix FPR FFF

Thank you! LSULSU