Design of a tracking device for on-line dose monitoring in hadron therapy S. Muraro for INSIDE collaboration VCI 20161.

Slides:



Advertisements
Similar presentations
PSD9, Aberystwyth, UK, 15 Sept Politecnico di Milano, Italy Development of a camera for imaging of prompt gamma rays in measurements.
Advertisements

Advanced GAmma Tracking Array
Study of plastic scintillators for fast neutron measurements
PET Design: Simulation Studies using GEANT4 and GATE - Status Report - Martin Göttlich DESY.
Energy deposition and neutron background studies for a low energy proton therapy facility Roxana Rata*, Roger Barlow* * International Institute for Accelerator.
Fysisk institutt - Rikshospitalet 1. 2 Overview Gamma camera Positron emission technology (PET) Computer tomography (CT) Proton therapy Electrical impedance.
Carbon ion fragmentation study for medical applications Protons (hadrons in general) especially suitable for deep-sited tumors (brain, neck base, prostate)
LHCf: a LHC Detector for Astroparticle Physics LHCf: a LHC Detector for Astroparticle Physics Lorenzo Bonechi on behalf of the LHCf Collaboration * University.
Vertex2002 pCT: Hartmut F.-W. Sadrozinski, SCIPP Initial Studies in Proton Computed Tomography L. R. Johnson, B. Keeney, G. Ross, H. F.-W. Sadrozinski,
The Origins of X-Rays. The X-Ray Spectrum The X-Ray Spectrum (Changes in Voltage) The characteristic lines are a result of electrons ejecting orbital.
RESMDD'02 pCT: Hartmut F.-W. Sadrozinski, SCIPP INITIAL STUDIES on PROTON COMPUTED TOMOGRAPHY USING SILICON STRIP DETECTORS L. Johnson, B. Keeney, G. Ross,
Interactions of charged particles with the patient I.The depth-dose distribution - How the Bragg Peak comes about - (Thomas Bortfeld) II.The lateral dose.
Study of the fragmentation of Carbon ions for medical applications Protons (hadrons in general) especially suitable for deep-sited tumors (brain, neck.
Vertex2002 pCT: Hartmut F.-W. Sadrozinski, SCIPP Initial Studies in Proton Computed Tomography L. R. Johnson, B. Keeney, G. Ross, H. F.-W. Sadrozinski,
Planar scintigraphy produces two-dimensional images of three dimensional objects. It is handicapped by the superposition of active and nonactive layers.
Radiation therapy is based on the exposure of malign tumor cells to significant but well localized doses of radiation to destroy the tumor cells. The.
RF background, analysis of MTA data & implications for MICE Rikard Sandström, Geneva University MICE Collaboration Meeting – Analysis session, October.
An integrated system for the on-line monitoring
Pennazio F 1, Battistoni G 2, Bisogni MG 3, Cappucci F 2, Cerello P 1, Del Guerra A 3, Fiorina E 4,1, Giraudo G 1, Kraan A 3, Mairani A 5, Morrocchi M.
The Transverse detector is made of an array of 256 scintillating fibers coupled to Avalanche PhotoDiodes (APD). The small size of the fibers (5X5mm) results.
The PEPPo e - & e + polarization measurements E. Fanchini On behalf of the PEPPo collaboration POSIPOL 2012 Zeuthen 4-6 September E. Fanchini -Posipol.
SOI detector Geant4-based studies to characterise the tissue-equivalence of SOI and diamond microdosimeteric detectors, under development at CMRP S. Dowdell,
Applications of Geant4 in Proton Radiotherapy at the University of Texas M.D. Anderson Cancer Center Jerimy C. Polf Assistant Professor Department of Radiation.
A Reconstruction Algorithm for a RICH detector for CLAS12 Ahmed El Alaoui RICH Workchop, Jefferson Lab, newport News, VA November th 2011.
T.C. Jude D.I. Glazier, D.P. Watts The University of Edinburgh Strangeness Photoproduction At Threshold Energies.
G. Bartesaghi, 11° ICATPP, Como, 5-9 October 2009 MONTE CARLO SIMULATIONS ON NEUTRON TRANSPORT AND ABSORBED DOSE IN TISSUE-EQUIVALENT PHANTOMS EXPOSED.
Scintillation hodoscope with SiPM readout for the CLAS detector S. Stepanyan (JLAB) IEEE conference, Dresden, October 21, 2008.
Medical Accelerator F. Foppiano, M.G. Pia, M. Piergentili
1 Radiotherapy, hadrontherapy and treatment planning systems. Faiza Bourhaleb INFN-Torino University Med 1er-Morocco  Radiotherapy  Optimization techniques.
Simulation of the energy response of  rays in CsI crystal arrays Thomas ZERGUERRAS EXL-R3B Collaboration Meeting, Orsay (France), 02/02/ /03/2006.
work for PID in Novosibirsk E.A.Kravchenko Budker INP, Novosibirsk.
Increase in Photon Collection from a YAP:Ce Matrix Coupled to Wave Lenght Shifting Fibres N. Belcari a, A. Del Guerra a, A. Vaiano a, C. Damiani b, G.
TPS & Simulations within PARTNER D. Bertrand, D. Prieels Valencia, SPAIN 19 JUNE 2009.
NA62 Gigatracker Working Group 28 July 2009 Massimiliano Fiorini CERN.
BES-III Workshop Oct.2001,Beijing The BESIII Luminosity Monitor High Energy Physics Group Dept. of Modern Physics,USTC P.O.Box 4 Hefei,
Apollo Go, NCU Taiwan BES III Luminosity Monitor Apollo Go National Central University, Taiwan September 16, 2002.
1 NaI calibrationneutron observation NaI calibration and neutron observation during the charge exchange experiment 1.Improving the NaI energy resolution.
Calorimeter in front of MUCh Mikhail Prokudin. Overview ► Geometry and acceptance ► Reconstruction procedure  Cluster finder algorithms  Preliminary.
EAS Time Structures with ARGO-YBJ experiment 1 - INFN-CNAF, Bologna, Italy 2 - Università del Salento and INFN Lecce, Italy A.K Calabrese Melcarne 1, G.Marsella.
Temporal and spatial structure of the Extensive Air Shower front with the ARGO- YBJ experiment 1 - INFN-CNAF, Bologna, Italy 2 - Università del Salento.
Magnetized hadronic calorimeter and muon veto for the K +   +  experiment L. DiLella, May 25, 2004 Purpose:  Provide pion – muon separation (muon veto)
Goddard February 2003 R.Bellazzini - INFN Pisa A new X-Ray Polarimeter based on the photoelectric effect for Black Holes and Neutron Stars Astrophysics.
1 Nuclear Medicine SPECT and PET. 2 a good book! SR Cherry, JA Sorenson, ME Phelps Physics in Nuclear Medicine Saunders, 2012.
FrontierScience G.P.1 MATRIX an innovative Pixel Ionization Chamber for Online Monitoring of Hadrontherapy Treatments Giuseppe Pittà.
Villa Olmo, Como October 2001F.Giordano1 SiTRD R & D The Silicon-TRD: Beam Test Results M.Brigida a, C.Favuzzi a, P.Fusco a, F.Gargano a, N.Giglietto.
P.F.Ermolov SVD-2 status and experimental program VHMP 16 April 2005 SVD-2 status and experimental program 1.SVD history 2.SVD-2 setup 3.Experiment characteristics.
Nuclear Medicine Physics and Equipment 243 RAD 1 Dr. Abdo Mansour Assistant Professor of radiology
N_TOF EAR-1 Simulations The “γ-flash” A. Tsinganis (CERN/NTUA), C. Guerrero (CERN), V. Vlachoudis (CERN) n_TOF Annual Collaboration Meeting Lisbon, December.
FP-CCD GLD VERTEX GROUP Presenting by Tadashi Nagamine Tohoku University ILC VTX Ringberg Castle, May 2006.
Open and Hidden Beauty Production in 920 GeV p-N interactions Presented by Mauro Villa for the Hera-B collaboration 2002/3 data taking:
Tracker Neutron Detector: INFN plans CLAS12 Central Detector Meeting - Saclay 2-3 December 2009 Patrizia Rossi for the INFN groups: Genova, Laboratori.
12 C fragmentation measurements for hadrontherapy applications Introduction Status French program Japanese-French collaboration.
Achim Stahl RWTH Aachen Hadron Therapy, Jülich Oct, Workshop Nuclear Models for Use in Hadron Therapy October 8./ Achim Stahl – RWTH Aachen.
The Electromagnetic Calorimetry of the PANDA Detector at FAIR
Study of Hypernuclei with Heavy Ion Beams (HypHI) at GSI Shizu Minami GSI, Germany on behalf of HypHI collaboration Introduction Phase 0 experiment R.
New idea for the target detector: SuperFGD
Development of a Compton Camera for online range monitoring
Diagnostics of FRIBs beam transport line
A novel gaseous X-ray polarimeter: data analysis and simulation
Reconstructions with TOF for in-beam PET
AQUA-ADVANCED QUALITY ASSURANCE FOR CNAO
Dose Profiler simulation update
Summary of the Compton-PET project
Detection of inhomogeneities with charged particles
INFN Pisa tasks Development of a PET system
Monte Carlo studies of the configuration of the charge identifier
Application of Nuclear Physics
Imaging crystals with TKR
GEANT Simulations and Track Reconstruction
First demonstration of portable Compton camera to visualize 223-Ra concentration for radionuclide therapy Kazuya Fujieda (Waseda University) J. Kataoka,
Presentation transcript:

Design of a tracking device for on-line dose monitoring in hadron therapy S. Muraro for INSIDE collaboration VCI 20161

Outline Particle Therapy (PT) and monitoring The INSIDE Project: the Dose profiler The Dose profiler performances VCI 20162

Particle therapy VS Photon RT Particle therapy: Peak of dose released at the end of the track, sparing the healty tissues Accurate conformal dose to tumor with Spread Out Bragg Peak Greater RBE (radioresistant tumors) Protons and 12 C beams are presently used to treat many different solid cancers. Photon RT: small, reliable and not so expensive, 40 years R&D VCI 20163

Particle therapy IMRT Examples of Photons vs Particle therapy Particle therapy can show better selectivity with respect to photon techniques VCI 20164

Quality Assurance & Range monitoring in PT The peculiarity height dose release at the end of the range in PT with respect to photon RT, make crucial the dose monitoring in PT. Inhomogeneities, metallic implants, CT artifact, HU conversion, inter session anatomical/physiological changes -> range variations a little mismatch in density by CT  sensible change in dose release VCI 20165

Beam range & secondary products Beam 511 keV prompt proton neutron The p, 12 C beam is dumped inside the patient. In order to monitor the beam the secondary particles generated by the beam interaction in the patient can be used: prompt γ’s, annihilation γ’s, neutrons and charged particles Activity of β + emitters Baseline approach Isotopes of short lifetime 11 C (20 min), 15 O (2 min), 10 C (20 s) with respect to diagnostic PET (hours) Low activity → long acquisition time (~minutes) with difficult in-beam feedback Metabolic wash-out of β + emitters Charged secondary particles (ion therapy): The detection efficiency is almost one Can be easily back-tracked to the emission point -> can be correlated to the beam profile & BP They are forward peaked Enough energy to escape from patient MS inside the patient -> worsen the back-pointing resolution Prompt nuclear de-excitation γ’s ~1-10 MeV emission profile correlated with dose profile Specific detector at present under development: collimated slit cameras or Compton cameras

Experimental campaign Charged fragments production is an high cross section process in the interactions of He, C and O beams and is hence particularly suited for monitoring applications of those beams. The experimental campaigns: Since 2011 the ARPG collaboration started a systematic characterization of the beam interaction with PMMA 80 MeV/u MeV/u 12 several energies: 4 He, 12 C, 16 O

8 BP monitoring A non negligible production of charged particles at large angles is observed for all beam types The emission shape is correlated to the beam entrance window and BP position = N all /(N ions ε Ω) Z (cm) # of tracks/0.4 cm BP Y (cm) He 145 He 125 He 102 BP data preliminary VCI 2016

Which detector should be used? A large area detector. The resolution of the back-tracking is limited by the multiple scattering in the patient, not by the detector resolution. Beam Bragg Peak  Diff between true and reconstructed emission point =  x Integrating enough statistic (~ 10 3 events) helps to lower the accuracy on the emission point distribution ( and then on the beam profile) to mm level  detector size Typical resolution on Δx is of the order of 6-8 mm Secondary proton VCI 20169

Outline Particle Therapy (PT) and monitoring The INSIDE Project: the Dose profiler The Dose profiler performances VCI

INnovative Solutions for In-beam DosimEtry in Hadrontherapy The  + activity distribution IN-BEAM PET HEADS proton emission Tracker + Calorimeter = DOSE PROFILER Integrated in treatment room of Centro Nazionale di Adroterapia Oncologica (CNAO) Operate in-beam Give an IMMEDIATE feedback on the particle range Effective both on proton and 12 C beam

28 x 28 x 35 cm 3 6/8 fibre planes calorimeter water cooling Elettronics: BASIC32, FPGA multi anode PMTs  6/8 planes of orthogonal squared scintillating fibers coupled to SiPMs  a calorimeter coupled to Position Sensitive PMTs. Dose Profiler (DP) VCI

Tracker 13 6/8 XY tracking planes: 384 scintillating fibers (0,5 mm) per side, with the minimal plane separation (2 cm) allowed by fibers front-end electronics readout in order to increase the geometrical acceptance and the compactness of the detector. Readout: Hamamatsu 1mm SiPM. Each SiPM coupled with two adjacent fibers. In total the 19.2 x 19.2 cm 2 sensitive area is read by 192 channels per layer. 32 SiPMs feed a 32 channels custom ASIC (BASIC32_ADC; F.Corsi, C.Marzocca et al. Politecnico and INFN Bari). Plane controller: 1 FPGA every 6 BASICS32 VCI 2016 FPGA BASIC32

Tracker The system is designed to sustain a rate of 20 kHz. rate of single p.e. is 100kHz per SiPM BASIC integration time of 100 ns noise rate of 10 Hz threshold of 3 p.e. The overall noise will be reduced at trigger level to a negligible rate by using the coincidence of 3 planes. The spatial single hit resolution is ~ 300 μm (double fiber readout). VCI

Calorimeter The role of the high density compact crystal scintillator placed behind the tracker is to measure the protons energy helping in track reconstruction (trigger and event selection). 64 x 64 matrix of pixelated LFS (Lutetium Fine Silicate) crystals arranged in 4 x 4 blocks (16 x 16 matrices 5 cm x 5 cm x 2 cm from Hamamatsu). The crystal readout will be performed by means of Multi Anode Photo-Multiplier (MAPMT H8500 from Hamamatsu). On the back, the MAPMT (MultiAnode PhotoMultiplier Tubes), the acquisition board (based on BASIC32_ADC) and the data concentrator. VCI

Outline Particle Therapy (PT) and monitoring The INSIDE Project: the Dose profiler The Dose profiler performances VCI

Simulation The Monte Carlo software used for simulations is FLUKA (release ) The real data from the GSI data taking has been used to parametrize a MC generator. L. Piersanti et al. Phys. Med. Biol. 59 (2014) Primary Beam Secondary Proton FLUKA The average kinetic energy of the protons of interest is about 75 MeV.

Event reconstruction and analysis Charged secondary particles are reconstructed with a track finding algorithm that starts from deposits in the fibers grouped together to form 3D clusters. 2D clusters: fiber hits in the xz and yz views are clustered separately by grouping consecutive hit fibers. 3D clusters: formed with all the possible combinations of x and y clusters in a plane. Track finder algorithm: starts from the list of 3D clusters. Initial guess: a simple linear fit and Kalman filter is applied to take into account the multiple scattering in the detector material. A backtracking extrapolation towards the patient is performed to reconstruct the point of closest approach (x,y,z coordinates) of the proton to the primary beam axis. 18

Performances Proton track angular resolution in agreement with the expected Multiple Scattering of the proton in the patient and in the tracker. 19 Resolution along the beam direction for protons detected at 90 o

Proton emission shape attenuation inside the patient By means of the attenuation study of the proton emission shape for different material thickness, we get a method to correlate the shape detected by the profiler coming out from the patient with the Bragg Peak position. We apply to each reconstructed track a weight which takes into account the thickness and density of the material crossed by the proton. Example: inhomgeneous PMMA sphere containing a smaller sphere of lighter material Measured shape Elaborated shape True emission shape 20 BEAM Detector L x True emission shape

Conclusions We designed a new device capable of dose pattern online measurements that is tailored for particle therapy applications. It detects and reconstructs charged particles, mainly protons, coming out from the patient. 21 1/2 The software tools needed for the full simulation and the event reconstruction have been developed. The detector expected resolution, estimated by means of a detailed MC simulation, meets the requirements set for online dose range monitoring applications for particle therapy.

Conclusions 22 2/2 This detector, particularly suited for carbon ion beams, is under construction. At present readout electronics is under test. A prototipe will be installed at CNAO within We develop a method to correlate the charged particles emission shape with the measured one, taking into account the matter absorption effect and complex geometries.

Thank you for the attention 23 The collaboration: G. Battistoni, F. Collamati, E. De Lucia, R. Faccini, M. Marafini, I. Mattei, S. Muraro, R. Paramatti, V. Patera, D. Pinci, A. Rucinski, A. Russomando, A. Sarti, A. Sciubba, E. Solfaroli Camillocci, M. Toppi, G. Traini, C. Voena