RAD 354 Chapt. 26 Digital Fluoro Terms to remember – DSA – digital subtraction angiography – Registration – Interrogation time – Hybrid subtraction – CCD.

Slides:



Advertisements
Similar presentations
DIGITAL RADIOGRAPHY.
Advertisements

Charge Couple Devices Charge Couple Devices, or CCDs operate in the charge domain, rather than the current domain, which speeds up their response time.
Digital Detectors n Cassette based Image Storage Phosphor (CR) n Image Intensifier n Scanned Projection n Direct Digitizing (Full Field) –CCD Camera –Selenium.
IMAGE QUALITY.
Digital Radiography.
RAD 354 Chapt. 28 The Digital Image Spatial resolution Contrast resolution Contrast-detail curve Pt. dose considerations.
RAD 350 Chapter 17Digital Rad Tech. Spatial Resolution – ability to distinguish small items in close proximity with near the same atomic mass density Spatial.
Advanced Biomedical Imaging Dr. Azza Helal A. Prof. of Medical Physics Faculty of Medicine Alexandria University Lecture 5 Advanced X ray machines &Mammogram.
RAD 354 Chapt. 26 Digital Imaging Many types/names for the digital imaging to come – Types CR: Barium fluorohalide PSP SPR (scan projection RAD): Nal scintillator/photodiode.
X-RAYS IN MOTION “Viewing dynamic studies of the human body”
Future Of Diagnostic Imaging A Look Into The Next Decade ? (Part 1)
Digital FLUORO Summer 2008.
Unsharpness Calculations and Resolution By Professor Stelmark.
From CCD to EMCCD Scientific imaging for today’s microscopy.
Charge-Coupled Device (CCD)
14.2 Data Capture Digital Imaging using CCDs. Capacitors  A capacitor is a device that stores charge.  Def’n of Capacitance - The ratio of the charge.
Radiation Exposure and Risk John Hamaty. Evaluation of Radiation Exposure Levels in Cine Cardiac Catheterization Laboratories American Association of.
Direct Digital Radiography or Direct Capture Radiography Bushong Ch. 27.
Fluoroscopy: Viewing Systems
Fluoroscopic Image Display
QUALITY ASSURANCE ADVANCED IMAGING EQUIPMENT CHAPTER 10.
RAD 354 Chapt. 13 Intensifying Screens
Overview of Scientific Imaging using CCD Arrays Jaal Ghandhi Mechanical Engineering Univ. of Wisconsin-Madison.
RAD 350 Chapt. 25 Fluoroscopy Fluoro’s primary function is to enable one to view the patient in “real time” with dynamic motion Invented by Thomas Edison.
DIGITAL FLUOROSCOPY.
FASEP Presents What is the difference between PSD and CCD sensor technology?
Digital Imaging Systems –I/O. Workflow of digital imaging Two Competing imaging format for motion pictures Film vs Digital Video( TV) Presentation of.
Computers in Imaging Q & A Robert Metzger, Ph.D..
Quality Control.
RAD 354 Chapt. 11 Control of Scatter Break down into: Those that reduce pt. dose and those that are geometrical in nature and those NOT! 3 factors affecting.
Equipment Design for Radiation Protection
Rad Tech 265 More Digital Imaging. Digital Fluoroscopy Radiation dose –Patient dose for DF is significantly less than conventional fluoro At 7.5 pulses/second.
RAD 350 Chapt. 18 Viewing the Digital Image Human eye – Rods – scotopic/night vision – Cones – photopic/day vision Lumen is the basic photometric unit.
Digital Imaging. acronyms 1.PSP 2.CRT 3.ADC 4.IP 5.CR 6.DR 7.PACS 8.SNR 9.CNR 10. CCD 11. FOV 12. LUT 13. DICOM 14. RIS 15. HIS 16. TFT 17. DQE 18. DAP.
Factors affecting CT image RAD
Fluoroscopy Q&A Robert L. Metzger, Ph.D..
Digital Radiography and PACS By Professor Stelmark.
Appendix H: Chapter 40: Fluoroscopy
PRINCIPLES OF TECHNIQUE AND EXPOSURE
Sounds of Old Technology IB Assessment Statements Topic 14.2., Data Capture and Digital Imaging Using Charge-Coupled Devices (CCDs) Define capacitance.
RAD 354 Chapt. 8 X-ray emission
Photoelectric Effect Photon and Charge Amplification and their use in NVDs (Night Vision Devices)
RAD 254 Chapter 27 Digital Fluoroscopy
RAD 150 Fluoroscopy Fluoro’s primary function is to enable one to view the patient in “real time” with dynamic (motion)
RAD 354 Chapt. 25 Fluoroscopy Fluoro’s primary function is to enable one to view the patient in “real time” with dynamic motion.
Beam Halo Monitoring using Optical Diagnostics Hao Zhang University of Maryland/University of Liverpool/Cockcroft Institute.
Inside the Digital Camera. Digital Camera Cross Section The digital camera is a complex device The only part that is the same as film cameras is the lens.
IMAGE RECEPTORS. Follow the Sequence- Film System Tube Tube Patient Patient (bucky) or non-bucky (bucky) or non-bucky Cassette Cassette INTENSIFYING SCREEN.
Fluoroscopy. Real-time imaging Most general-purpose fluoroscopy systems use TV technology, operating at 30 frames/sec May be recorded (barium swallow.
RAD 354 Chapt. 16 Image QUALITY
Fluroscopy and II’s. Fluroscopy Taking real time x-ray images Requires very sensitive detector to limit the radiation needed Image Intensifier (II) is.
Direct Digital Radiography or Direct Capture Radiography
Acronyms. A SEQUENCE OF COMPUTER OPERATIONS FOR ACCOMPLISHING A SPECIFIC TASK Algorithm.
Digital Image -M.V.Ramachandranwww.youtube.com/postmanchandru
Computed tomography. Formation of a CT image Data acquisitionImage reconstruction Image display, manipulation Storage, communication And recording.
Imaging Characteristics
Digital Imaging.
Rad Tech 265.
Medical Imaging Imagining Modalities.
Fluoroscopic Unit Thomas Edison 1896.
כיצד נרכשת התמונה בסרט הרנטגני?
מה צריך רנטגנאי לדעת על דימות דיגיטלית?
Digital Imaging CHAPTERS 1, 4-7 CARTER.
Fluoroscopy – Viewing Systems TV Monitors
Fluoroscopy: Static Image Recording Systems
Chapter 6 Cassetteless Equipment and Image Acquisition
DIGITAL SUBTRACTION ANGIOGRAPHY
Digital Imaging.
Digital Imaging.
Presentation transcript:

RAD 354 Chapt. 26 Digital Fluoro Terms to remember – DSA – digital subtraction angiography – Registration – Interrogation time – Hybrid subtraction – CCD = charge coupled device – ROI = region of interest – PACS = picture archival and communication system

Advantages of DF Speed of image acquisition Post processing “tweaking” of the image(s) – Spatial resolution is determined by the matrix size (usually 1024 X 1024) and the size of the image intensifier) DF operates at “conventional mAs” (hundreds of mA rather than less than 5 mA as conventional fluoro) BUT – DF operates in “pulsed, progressive” fluoro!

“Pulsing” Terms Interrogation time = time for unit to be switched on and reach the mA and kVp level Extinction time = time for the tube to be switched off (usually times less than 1 ms)

Receptor The “receptor” is usually a “charge coupled device” (CCD) – CCD’s are VERY sensitive to light and have a much LOWER level of noise than a TV camera This results in much HIGHER SNR than conventional TV cameras/systems They also have NO lag time or “blooming” and require NO maintenance CCD’s may be “docked” directly to the II’s output phosphor

Advantages of CCD’s High spatial resolution High SNR High Detective Quantum Efficiency (DQE) No warm up required No lag/blooming No spatial distortion/maintenance Unlimited life Unaffected by magnetic fields Lower pt. dose

CCD

DR Subtration TWO Primary Types Temporal subtraction – Single kVp setting – Normal filtration – Good contrast resolution 1 mm) – Simple arithmetic image subtraction used – Motion artifacts are a problem (misrepresentation) – Total subtraction is able to be achieved – Subtraction limited by number of images

Energy Subtraction Rapid voltage switching is used Filter switching is preferred Higher x-ray energy used for + contrast resol. Complex image subtraction is required Motion artifacts (misrepresentation) are reduced Some residual bone is survived (shows) More types of subtraction are possible IF BOTH ARE COMBINED = HYBRID SUBTRACTION

DF/D Subtraction RAD Dose DF & D Subtraction usually result in much higher pt. dose and PULSED imaging is required to lower the dose! Storage and image distribution are used as already discussed in class

Images

Lateral Cerebral DSA

DSA Hand