HIGH VOLTAGE UNION Vacuum Circuit Breaker 110 kV VRS-110 Series ВЫСОКОВОЛЬТНЫЙ СОЮЗ www.vsoyuz.com.

Slides:



Advertisements
Similar presentations
L.T Circuit Breakers.
Advertisements

Seminar on Circuit Breaker
Medium-Voltage Switchgear - Then and Now -
Detail Discussion on Different type of Circuit Breaker
Inspection & Preventive maintenance of breakers
April 27, 2012 Presented by: Andy Justice SWEDE Southwest Electric Distribution Exchange “The Evolution of Distribution Switchgear”
RMM Systems, LLC By Sam Rietta RMM Systems, LLC is a manufacturer's representative firm focused on providing value added sales solutions by providing.
HVAC Commercial Ref.
Sputter Stand Safety Specifics Electrical Hazards High Voltage : Electrical power is required for the high voltage supply, gauging, system controller and.
© Copyright year ABB. All rights reserved /1/2015 VBF OUTDOOR VACUUM CIRCUIT BREAKER 36kV PRODUCT INFORMATION.
During fault behavior of circuit breaker
Inspection & Test Overview suite412.
Ignition System Provides a method of turning a spark ignition engine on & off. Operates on various supply voltages (Battery & Alternator) Produces high.
Schutzvermerk / Copyright-Vermerk SION Vacuum Circuit-Breaker For Standard Applications Siemens Medium Voltage Sector Energy, Business Unit Medium Voltage.
Slide 1 UNCLASSIFIED Breaker Operation Arc Flash Breakout Group EFCOG Electrical Safety Workshop – July 18, 2014.
FIPTMV Medium Voltage Technology
December, 2010 Vmax – Indoor vacuum circuit-breakers for Primary Distribution Product presentation 1VCP – Rev. D, en – Presentation –
ABB - 1- ABB ABB Load Interrupter Switchgear. ABB - 2 ABB Contents Introduction to Load Interrupter Switchgear What, Where, Why ABB Technical Offering.
VHA PANEL WITH HPA12 CIRCUIT BREAKER
Multi-function apparatus for secondary distribution
3AH5 Vacuum Circuit-Breaker For Standard Applications
Md.Kausher ahmed Electrical department
SECTION 4 ELECTRIC MOTORS UNIT 19 MOTOR CONTROLS.
Electrical Installation 2
Circuit breakers The main purpose of a circuit breaker is to: Switch load currents Make onto a fault Break normal and fault currents Carry fault current.
Transformer Taking the ratio of the two equations
1200 kV AC Substations - Products and Integrated Solutions International UHV Symposium New Delhi, 29. January 2009 Edelhard Kynast Siemens AG, Energy.
Reyrolle LMT Breaker Retrofit BU PPMV – PG Service Marketing and Sales
PowerIT Air Insulated Cubicle Uniswitch
Introduction to switchgears
High frequency solenoid valve SX10 Series
Air Blast Circuit Breaker
Basic study of a switch Unit 3.Lesson 3. A switch Purpose A switch is a mechanical device used to connect and disconnect a circuit at will Parts seen.
Plan for test station Marta Bajko For the Technical Review of FReSCa2 June 2015 Saclay Paris.
Disconnector Switches and Earth Switches
Hao Zhu Dept. of Electrical & Computer Engineering University of Illinois, Urbana-Champaign ECE 498HZ: Power Distribution System Analysis.
Electrical Testers Basic test equipment used in today’s shops may include an analog type meter, a VAT (Volt-Amp-Tester), DMM (Digital Multimeter),
VACUUM CIRCUIT BREAKER. WHAT IS A CIRCUIT BREAKER A circuit breaker is an equipment that breaks a circuit either manually or automatically under all conditions.
Presentation Topic: Circuit Breakers Represented to: Dr. M. Riaz Khan Represented by: M. Mujahid.
OEZ s.r.o. Quick and universal solution for your order Modeion 05/2012.
By:- Abhishek Bhardwaj IV year VIII sem Roll NO.– four(04)
Ignition System Provides a method of turning a spark ignition engine on & off. Operates on various supply voltages (Battery & Alternator) Produces high.
Automatic Transfer Switches
Sub Station.
SUB-STATIONS.
42-a Machine st., 101 Yekaterinburg Russian Fediration Phone:+7(343)
Projekt Anglicky v odborných předmětech, CZ.1.07/1.3.09/
3AH5 Vacuum Circuit-Breaker For Standard Applications
PRESENTATION ON SUMMER TRAINING PROGRAM
MV vacuum circuit-breakers for secondary distribution
3AH5 Vacuum Circuit-Breaker For Standard Applications
Protecting you from the worst electrical problems
Protecting you from the worst electrical problems
Overview Key diagram of 220 KV Sub station, Ablowal Cables
High Voltage Power Circuit Breakers
SION Vacuum Circuit-Breaker For Standard Applications
ELECTRICAL POWER-II Electrical engineering sixth semester
Protecting you from the worst electrical problems
SWITCH GEAR AND PROTECTION(IV-1) TOPIC-CIRCUIT BREAKER
Ignition System Provides a method of turning a spark ignition engine on & off. Operates on various supply voltages (Battery & Alternator) Produces high.
Protecting you from the worst electrical problems
History of SF6 High Voltage Circuit Breakers
3AH5 Vacuum Circuit-Breaker For Standard Applications
CIRCUIT BREAKERS E. Chikuni. Circuit Breakers Mechanical Switches capable of making and breaking currents under normal circuit conditions and for a specified.
Its strengths, your benefits
0 Air Blast Circuit Breaker under the guidance of:- Presented By:- Mr. B.R.Reddy Anuj Kumar Pandey EN-3 rd year Roll No Unrestricted.
Its strengths, your benefits
Biosco: MV/LV prefabricated substations IEC Presentation of the standard Safety is a choice.
Substation Equipment's
Presentation transcript:

HIGH VOLTAGE UNION Vacuum Circuit Breaker 110 kV VRS-110 Series ВЫСОКОВОЛЬТНЫЙ СОЮЗ

Application ВЫСОКОВОЛЬТНЫЙ СОЮЗ Vacuum Circuit Breaker 110 kV VRS-110 Series Installation in new switchgears Replacement of obsolete switchgear in the existing switchgears* * Concern prepared standard solutions for the replacement of obsolete circuit breakers for BPS110

Functional features ВЫСОКОВОЛЬТНЫЙ СОЮЗ Minimum maintenance Minimum mounting Mechanical life up to cycles of ON / OFF Switching resource 20 cycles on / off at the rated breaking current 31.5 kA Switching life cycles on / off at nominal current The possibility of operating in a wide temperature range from -60 C ° to +50 C ° Vacuum Circuit Breaker 110 kV VRS-110 Series

Constructive principles ВЫСОКОВОЛЬТНЫЙ СОЮЗ Nominal voltage 110 kV Maximum operating voltage 126 kV Nominal current 2500 A Rated breaking current 31.5 kA The normalized percentage of aperiodic component not more than 40% Resistance not more than 10 microhm Mechanical life cycles ON / OFF Switching resource at: nominal current cycles ON / OFF nominal breaking current 20 cycles of ON / OFF Weight 59 kg VACUUM CHAMBER Vacuum Circuit Breaker 110 kV VRS-110 Series

Constructive principles ВЫСОКОВОЛЬТНЫЙ СОЮЗ One discontinuity per phase (a first for a 110 kV circuit breakers) Quenching of the arc in vacuum Isolation of the poles of the organosilicon compound diecast Spring actuator Internal cavity filled with nitrogen at the poles of low pressure to prevent condensation Terms of isolation - III degree of contamination according to GOST Vacuum Circuit Breaker 110 kV VRS-110 Series

Constructive principles ВЫСОКОВОЛЬТНЫЙ СОЮЗ SPRING ACTUATOR Winding switch-off spring by a motor- reducer Including the ability to manually winding a spring drive Lateral placement of the drive spring breakers, provides good access to it Vacuum Circuit Breaker 110 kV VRS-110 Series

Montage ВЫСОКОВОЛЬТНЫЙ СОЮЗ The switch comes fully assembled and regulated form (client can only connect it to the posts and attach (without regulation), the drive) The switch is supplied at the working pressure of nitrogen Vacuum Circuit Breaker 110 kV VRS-110 Series

Dimensional drawing ВЫСОКОВОЛЬТНЫЙ СОЮЗ Vacuum Circuit Breaker 110 kV VRS-110 Series With supporting metal constructions

Dimensional drawing ВЫСОКОВОЛЬТНЫЙ СОЮЗ Vacuum Circuit Breaker 110 kV VRS-110 Series Without supporting metal constructions

Dimensional drawing ВЫСОКОВОЛЬТНЫЙ СОЮЗ Vacuum Circuit Breaker 110 kV VRS-110 Series With a protective shield and ladder

Technical parameters of the switch ВЫСОКОВОЛЬТНЫЙ СОЮЗ Nominal voltage110 kV Maximum operating voltage 126 kV Rated breaking current2 500 A Rated peak withstand current81 kA Thermal stability current (3s)31,5 kA The proper time of switching on no more than 70 ms The proper time of switching off no more than 45 ms Full time of switching off no more than 60 ms Switching resource at nominal current cycles on/off Switching resource at a nominal breaking current 20 cycles on/off The mass of the circuit breaker kg Vacuum Circuit Breaker 110 kV VRS-110 Series

List of companies that take the machine into pilot operation ВЫСОКОВОЛЬТНЫЙ СОЮЗ MES South MRSC of Volga MRSC of North-West Tyumenenergo Vacuum Circuit Breaker 110 kV VRS-110 Series In early 2011 a series of vacuum circuit breaker VRS-110 will be put on trial operation in the following companies:

Certification ВЫСОКОВОЛЬТНЫЙ СОЮЗ Tests are carried out in SRC BBA - February 2011, Moscow Vacuum Circuit Breaker 110 kV VRS-110 Series Certification - Association of high voltage equipment testing facilities «Energosert», Moscow

Contact Us ВЫСОКОВОЛЬТНЫЙ СОЮЗ CONCERN «HIGH VOLTAGE UNION» Vacuum Circuit Breaker 110 kV VRS-110 Series St. Torgovaya, 5, Ekaterinburg, , Russia Phone: (+7 343) Fax: (+7 343) Delivery time - 60 days Warranty period years from the date putting into operation MANUFACTURING «NTEAZ Electric»

Thank you for your attention ! © 2011 HIGH VOLTAGE UNION