Receive Coil Arrays and Parallel Imaging for fMRI of the Human Brain

Slides:



Advertisements
Similar presentations
Assessment of tumoural ADC’s in rectal Tumours using Burst: New methodological Developments SJ Doran 1, ASK Dzik-Jurasz 2, J Wolber 2, C Domenig 1, MO.
Advertisements

BOLD Imaging at 7T Mark Elliott CfN Symposium 4/9/2008.
Magnetic Resonance Imaging
In Chan Song, Ph.D. Seoul National University Hospital
Richard Wise FMRI Director +44(0)
NON-EXPONENTIAL T 2 * DECAY IN WHITE MATTER P. van Gelderen 1, J. A. de Zwart 1, J. Lee 1,3, P. Sati 1, D. S. Reich 1, and J. H. Duyn 1. 1 Advanced MRI.
Statistical Parametric Mapping
Evaluation of Reconstruction Techniques
Figure 2. Signal level (left) degrades with slice offset and slice thickness when Z2 SEM is used in GradLoc imaging (ROI = FOV/2). To recover the full.
Parameters and Trade-offs
Topics spatial encoding - part 2. Slice Selection  z y x 0 imaging plane    z gradient.
Functional Brain Signal Processing: EEG & fMRI Lesson 12 Kaushik Majumdar Indian Statistical Institute Bangalore Center M.Tech.
Terry M. Button, Ph.D. Principals of Magnetic Resonance Image Formation.
Methods: Scanner: GE 7T Excite (bore 60cm diam x 335cm length) and GE 3T LX (bore 60cm diam x 262cm length). The gradient performance of both scanners.
Realigning and Unwarping MfD
Bruce Fischl MGH ATHINOULA A. MARTINOS CENTER Harvard Medical School MIT CSAIL/HST some open issues in functional MRI (thanks to Larry Wald for almost.
Chapter 10 Lecture Mark D. Herbst, M.D., Ph.D..
Real-Time MRI – Outline Biomed NMR JF11/59 Technical Considerations - Data Acquisition - Image Reconstruction Preliminary Applications - Joint Movements,
Magnetic resonance is an imaging modality that does not involve patient irradiation or significant side effects, while maintaining a high spatial resolution.
Steady-state free precession and other 3D methods for high-resolution FMRI Steady-state free precession and other 3D methods for high-resolution FMRI Karla.
EPI – Echo Planar Imaging Joakim Rydell
Evidence of Interictal Epilepctic Activity Using Simultaneous MRI and EEG.
Arterial Spin Labeling at 7T - Double Edged Sword
FMRI: Biological Basis and Experiment Design Lecture 12: Signal-to-Noise Ratio Things that determine signal strength –voxel size –RF coil Things that determine.
A novel technique has been proposed for dynamic MRI: Dynamic KWIC Permits image reconstruction at both high spatial and high temporal resolutions Technique.
Compressed Sensing for Chemical Shift-Based Water-Fat Separation Doneva M., Bornert P., Eggers H., Mertins A., Pauly J., and Lustig M., Magnetic Resonance.
MRI Image Formation Karla Miller FMRIB Physics Group.
Medical Imaging Systems: MRI Image Formation
Principles of MRI Physics and Engineering
Imaging Sequences part II
Parallel Imaging Reconstruction
Jason P. Stockmann 1 and R. Todd Constable 1,2 Yale University, Department of Biomedical Engineering 1, Department of Diagnostic Radiology 2, New Haven,
Introduction Many clinicians routinely use multiple receive coils for magnetic resonance imaging (MRI) studies of the human brain. In conjunction with.
Susceptibility Induced Loss of Signal: Comparing PET and fMRI on a Semantic Task Devlin et al. (in press)
Basics of Functional Magnetic Resonance Imaging. How MRI Works Put a person inside a big magnetic field Transmit radio waves into the person –These "energize"
Partial Parallel imaging (PPI) in MR for faster imaging IMA Compressed Sensing June, 2007 Acknowledgement: NIH Grants 5RO1CA and 5P41RR008079, Pierre-Francois.
Simultaneous Multi-Slice (Slice Accelerated) Diffusion EPI Val M. Runge, MD Institute for Diagnostic and Interventional Radiology Clinics for Neuroradiology.
Contrast Mechanism and Pulse Sequences Allen W. Song Brain Imaging and Analysis Center Duke University.
EE369C Final Project: Accelerated Flip Angle Sequences Jan 9, 2012 Jason Su.
FINSIG'05 25/8/2005 1Eini Niskanen, Dept. of Applied Physics, University of Kuopio Principal Component Regression Approach for Functional Connectivity.
Mitglied der Helmholtz-Gemeinschaft EPIK for TRIMAGE Seong Dae Yun 1 and N. Jon Shah 1,2 1 Institute of Neuroscience and Medicine 4 Forschungszentrum Jülich.
Daily fMRI Practice John Li MD 9/27/2012. When you preparing a fMRI study, you need to Read and understand the fMRI requirements. Design and choose proper.
G Practical MRI 1 Gradients.
Recent advances in Magnetic Resonance Imaging Peter Fransson MR Research Center, Cognitive Neurophysiology Dept. of Clinical Neuroscience, Karolinska Institute.
Contrast Mechanism and Pulse Sequences
A CCELERATED V ARIABLE F LIP A NGLE T 1 M APPING VIA V IEW S HARING OF P SEUDO -R ANDOM S AMPLED H IGHER O RDER K-S PACE J.Su 1, M.Saranathan 1, and B.K.Rutt.
Statistical Parametric Mapping
Jason P. Stockmann 1, Gigi Galiana 2, Leo Tam 1, and R. Todd Constable 1,2 Yale University, Department of Biomedical Engineering 1, Department of Diagnostic.
Somatotopy of the Anterior Cingulate Cortex and Supplementary Motor Area for tactile stimulation of the hand and the foot D. Arienzo 1,2, T.D. Wager 3,
Spatial and temporal limits of fMRI Menon RS, Kim SG. Spatial and temporal limits in cognitive neuroimaging with fMRI. Trends Cogn Sci Jun;3(6):
Declaration of Relevant Financial Interests or Relationships David Atkinson: I have no relevant financial interest or relationship to disclose with regard.
MRI: Contrast Mechanisms and Pulse Sequences
Principles of MRI Physics and Engineering Allen W. Song Brain Imaging and Analysis Center Duke University.
DTI Acquisition Guide Donald Brien February 2016.
Real time shimming (RTS) for compensation of respiratory induced field changes P van Gelderen, JA de Zwart, P Starewicz, RS Hinks, JH Duyn Introduction.
Nicole Seiberlich Workshop on Novel Reconstruction Strategies in NMR and MRI 2010 Göttingen, Germany 10 September 2010 Non-Cartesian Parallel Imaging based.
A CCELERATED V ARIABLE F LIP A NGLE T 1 M APPING VIA V IEW S HARING OF P SEUDO -R ANDOM S AMPLED H IGHER O RDER K-S PACE J.Su 1, M.Saranathan 1, and B.K.Rutt.
Parameters which can be “optimized” Functional Contrast Image signal to noise Hemodynamic Specificity Image quality (warping, dropout) Speed Resolution.
BOLD functional MRI Magnetic properties of oxyhemoglobin and deoxyhemoglobin L. Pauling and C. Coryell, PNAS USA 22: (1936) BOLD effects in vivo.
He-Kwon Song, PhD Associate Professor & Co-investigator in the CMROI, Department of Radiology, University of Pennsylvania School of Medicine, Philadelphia,
FMRI data acquisition.
Non-linear Realignment Using Minimum Deformation Averaging for Single-subject fMRI at Ultra-high Field Saskia Bollmann1, Steffen Bollmann1, Alexander.
PowerGrid for harnessing high performance computing to reconstruct large sets of high-resolution non-Cartesian MRI data Brad Sutton Assoc Prof, Bioengineering.
Sunday Case of the Day Physics
MRI Physics in a Nutshell Christian Schwarzbauer
بسم الله الرحمن الرحيم.
Parallel Imaging Artifacts in Body Magnetic Resonance Imaging
Signal fluctuations in 2D and 3D fMRI at 7 Tesla
3T-versus-7T DTI with 36 diffusion-encoding directions at b = 3000 s/mm2 and 2.0 × 2.0 × 2.0 mm isotropic voxel resolution. 3T-versus-7T DTI with 36 diffusion-encoding.
Pulse sequence diagrams show the benefits of parallel imaging for DWI
Presentation transcript:

Receive Coil Arrays and Parallel Imaging for fMRI of the Human Brain Jacco de Zwart No longer accelerated. Accelerated to indicate that data were undersampled, but not all examples here are faster imaging Advanced MRI section, LFMI, NINDS National Institutes of Health Bethesda, MD, USA

Outline Part I - Receive Coil Arrays Part II - Parallel Imaging Part III - Parallel Imaging & fMRI Nicely introduced by Kamil Ugurbil yesterday

Part I Receive Coil Arrays

Multi-Coil Imaging ≠ Parallel Imaging?!? "Parallel Imaging" = multi-coil imaging where data are undersampled during acquisition Will be discussed in Part II of this talk Parallel Imaging (PI) requires a receive coil array Typically results in a loss of SNR compared to the equivalent fully sampled case when using the same hardware Receive coil arrays used without PI Covered here in Part I of this talk Generally yields an SNR increase compared to a conventional volume coil

Why Use a Receive Coil Array? Smaller coils 'see' less noise  increased SNR close to the coil BUT: small coils have a limited field-of-view SOLUTION: cover the object with small coils SNR in center same as with equally-sized volume coil (e.g. birdcage) SNR everywhere else , highest gain close to coils Signal originates from single voxel Noise originates from all tissue "observed" by coil

What is the Limit? Sample noise should be the dominant noise source Other noise sources: coil, preamplifier Sample noise decreases with coil size (to the 3rd power!) Sample noise increases with field strength (~linearly) Optimal number of elements (our guesstimates for the human head): ~20 coil elements @ 1.5 T ~32 coils @ 3.0 T ~64 coils @ 7.0 T

Number of Coil Elements & Image SNR average over entire brain center of the brain acquired 16-channel data 1, 2, 4 & 8 channel data derived from 16-channel data

16-Element Array vs. Head Coil @ 3 T image intensity scaling factor SNR SNR GE head coil 128×96 192×144 rate-2 SENSE 128×96 16-element array Performance gain: 2-fold in center, up to 6-fold in peripheral cortex!

Conclusion for Part I Receive coil arrays outperform similarly-sized volume coils Equal performance in center of object Performance gain everywhere else, greatest in periphery

Part II Parallel Imaging

Undersampled MR Imaging R-fold undersampling of MR-data Yields R-fold reduction of acquisition time BUT: Aliasing in the image Information is lost due to this folding artifact Signals from different object regions are superimposed and cannot be distinguished Unless… R=2

Undersampled MR Imaging Unless… a receive coil array was used: Sensitivity profile for each coil element different  Relative contribution of superimposed signals different for each coil Allows unaliasing images in post-processing in image domain: "SENSE" [Pruesmann, Magn Reson Med 1999, 42:952] in k-space: "SMASH" [Sodickson, Magn Reson Med 1997, 38:591] Undersampled acquisition with receive coil array + Unaliasing during image reconstruction = Parallel Imaging

Parallel Imaging Penalty With n coil elements, up to n-fold acceleration BUT: SNR reduced due to reduced sampling AND: additional noise introduced by reconstruction generally referred to as g-factor (= spatially varying) depends on coil configuration acceleration rate Parallel Imaging (PI) penalty increases with: higher acceleration factors lower number of coil elements

Example – human brain imaging w. PI + Image obtained using SENSE reconstruction 1.5 T GE Signa LX EPI w. 50% ramp sampling 64×48 / 64×24 matrix 220×165 / 220×83 mm2 FOV 2000 ms TR 40 ms TE 4 mm slice thickness 24.1 / 12.3 ms echo train Full-FOV images for each individual coil  coil sensitivity information (acquired only once!) Undersampled images 4-element dome coil courtesy of Patrick Ledden, Nova Medical Inc, Wakefield, MA, USA

Conclusion for Part II Parallel Imaging increases imaging speed at the cost of image SNR

Part III Parallel Imaging & fMRI

Does PI Make SENSE For fMRI? Disadvantage: PI  reduced image SNR ~ g√R [Pruessman et al., MRM 1999, 42:952] DUE TO: g-factor + R-fold reduction in sampling time But: temporal stability determines fMRI sensitivity temporal stability determined by sum of: image SNR scanner stability physiologic noise Therefore: PI penalty for fMRI typically less than reduction in image SNR SNR loss is associated with most PI applications, which I call accelerated PI here, like acquisition train shortening or resolution increase not affected by PI

PI-fMRI Sensitivity Penalty gR = full PI loss PI noise increase 1 = no loss! Illustrated by this figure / all voxels in brain of a normal volunteer / solid line is model / basically demonstrates that resolution can be optimized for given hardware+experiment such that experiment is not dominated by image SNR intrinsic noise contribution stability-limited SNR-limited All superior brain voxels; normal volunteer; 1.5 T; 4-element coil; 3.8×3.8×4.0 mm3 voxels; rate-2 SENSE; gradient-echo EPI [de Zwart et al., MRM 2002, 48:1011]

Does PI Make SENSE For fMRI? But there are several advantages of PI use: artifacts  geometrical distortions  signal loss in inhomogeneous areas  temporal resolution  gradient acoustic noise  spatial resolution  important for single-shot imaging at high field

Is PI Essential For fMRI At High Field? When B0  (A) NMR signal   CNR  (B) More large vessel suppression  specificity  BUT: (C) T2  & T2*  (D) T1  (A)&(B)  allows higher spatial resolution BUT: (C)  blurring  Parallel Imaging can help:  higher spatial resolution for given sampling window

Example: 3 T Results, R=2 @ 192×144 Mention first EPI time series image Single-shot gradient echo EPI @ 3.0 T, rate-2 SENSE - 16-channel coil [de Zwart et al., Magn Reson Med 2004, 51:22] - 16-channel receiver [Bodurka et al., Magn Reson Med 2004, 51:165] - 1.1×1.1×1.5 mm3 resolution (192×144 matrix) - 2000 ms TR, 48 ms TE, 14 slices, 73.1 ms readout train - 5-min scan; visual paradigm stimulates alternately peripheral (red/yellow) and foveal (blue) vision

7 T Results: Single-Shot R=3 @ 192×120 single-shot EPI, rate-3 SENSE, 39.9 ms readout, 5 min scan time 192×120 = 1.25×1.25×1.0 mm3 background = first EPI volume finger tapping paradigm zoom on next slide

7 T Results: R=3 @ 192×120 EPI image from 1st time point same slice with functional overlay single-shot EPI, rate-3 SENSE, 39.9 ms readout, 5 min scan time 192×120 = 1.25×1.25×1.0 mm3 finger tapping paradigm

Conclusion for Part III PI: fMRI penalty < image SNR penalty PI-fMRI benefits: Reduce geometrical distortions Reduce signal loss due to inhomogeneity Increase spatial resolution Increase temporal resolution Reduce gradient acoustic noise PI-fMRI is important (essential?) for BOLD-fMRI at high field

Further Information Fifteen minutes is too short to cover it all, so if you have questions… ask me! E-mail = Jacco.deZwart@nih.gov And/or: The journal NMR in Biomedicine recently dedicated a special issue to Parallel Imaging (May 2006)

Acknowledgements National Institutes of Health, Bethesda, MD, USA Jerzy Bodurka Jeff Duyn Peter van Gelderen Martijn Jansma Peter Kellman Nova Medical, Wilmington, MA, USA Patrick Ledden

Thanks a lot for your attention! Advanced MRI section LFMI/NINDS/NIH http://www.amri.ninds.nih.gov/