2001/9/111 X-ray polarimetry with balloon borne gas proportional counters K.Hayashida, H. Tsunemi, T. Horikawa, Y. Nakashima (Osaka University, Japan),

Slides:



Advertisements
Similar presentations
Instruments for Radiation Detection and Measurement Lab # 4.
Advertisements

RHESSI Studies of Solar Flare Hard X-Ray Polarization Mark L. McConnell 1, David M. Smith 2, A. Gordon Emslie 4, Martin Fivian 3, Gordon J. Hurford 3,
Polarization measurements for CLARREO
X-Ray Astronomy Lab X-rays Why look for X-rays? –High temperatures –Atomic lines –Non-thermal processes X-ray detectors X-ray telescopes The Lab.
X-ray Instruments for MiniSatellites High Resolution Spectroscopic Survey Missing Baryons: Warm Hot Intergalactic Material(WHIM) Wide Field Monitoring.
INSTITUT MAX VON LAUE - PAUL LANGEVIN Fast Real-time SANS Detectors Charge Division in Individual, 1-D Position- sensitive Gas Detectors Patrick Van Esch.
Evolving X-ray Polarimetry towards high energy and solar science Sergio Fabiani Università degli Studi di Roma “Tor Vergata” INAF / IAPS I A P S Istituto.
1 T. Mizuno et al. August 23, 2014 HEAPA Symposium on Future T. Mizuno (Hiroshima Univ.) on behalf of the SGD team and Polarization team.
Radiation Detectors / Particle Detectors
Abstract We describe development of a Thomson X-ray polarimeter for a small satellite mission of the Indian Space Research Organisation (ISRO). A laboratory.
The PHENEX Experiment Results in 2006 and Future Plan S. Gunji* a, Y. Kishimoto a,H. Sakurai a, F. Tokanai a, M. Kanno a, Y. Ishikawa a, Hayashida b, N.
X-ray polarisation: Science
1 Extreme Ultraviolet Polarimetry Utilizing Laser-Generated High- Order Harmonics N. Brimhall, M. Turner, N. Herrick, D. Allred, R. S. Turley, M. Ware,
BME 560 Medical Imaging: X-ray, CT, and Nuclear Methods
Types of Radiation Interactions All or Nothing Many Small There is a finite probability per unit length that the radiation is absorbed. If not, there is.
Computed Tomography RAD309
RHESSI Studies of Solar Flare Hard X-Ray Polarization Mark L. McConnell 1, David M. Smith 2, A. Gordon Emslie 4, Martin Fivian 3, Gordon J. Hurford 3,
Position sensing in a GEM from charge dispersion on a resistive anode Bob Carnegie, Madhu Dixit, Steve Kennedy, Jean-Pierre Martin, Hans Mes, Ernie Neuheimer,
X-ray Polarization as a Probe of Strong Magnetic Fields in X-ray Binaries Shane Davis (IAS) Chandra Fellows Symposium, Oct. 17, 2008.
Main detector types Multi Pixel Photon Counter (MPPC) and Charge Coupled Devices (CCDs) How does it work? 1. Photon hits a pixel producing electron hole.
Polarimetry in Astronomy Or Do you know where your photons are coming from? Elizabeth Corbett AAO.
Techniques for detecting X-rays and gamma-rays Pair production Creation of elementary particle and its antiparticle from a photon. Occurs only if enough.
Main detector types Scintillation Detector Spectrum.
Instruments for Radiation Detection and Measurement
Planar scintigraphy produces two-dimensional images of three dimensional objects. It is handicapped by the superposition of active and nonactive layers.
Instruments for Radiation Detection and Measurement Lab # 3 (1)
X-ray Polarimetry with gas proportional counters through rise-time K. Hayashida, T. Horikawa, Y. Nakashima, H. Tsunemi (Osaka University, Japan)
Photon detection Visible or near-visible wavelengths
Why silicon detectors? Main characteristics of silicon detectors: Small band gap (E g = 1.12 V)  good resolution in the deposited energy  3.6 eV of deposited.
Chapter 12 Atomic X-Ray Spectroscopy
Status of DRIFT II Ed Daw representing the DRIFT collaboration: Univ. of Sheffield, Univ. of Edinburgh, Occidental College, Univ. of New Mexico Overview.
Status of the Beamline Simulation A.Somov Jefferson Lab Collaboration Meeting, May 11, 2010.
X - RAYS IN DIAGNOSTICS D. Krilov
PHYSICS DEPARTMENT.
Hard X and Gamma-ray Polarization: the ultimate dimension (ESA Cosmic Vision ) or the Compton Scattering polarimetery challenges Ezio Caroli,
10/26/20151 Observational Astrophysics I Astronomical detectors Kitchin pp
Neutron scattering systems for calibration of dark matter search and low-energy neutrino detectors A.Bondar, A.Buzulutskov, A.Burdakov, E.Grishnjaev, A.Dolgov,
2000/11/101 X-ray polarimetry experiment with balloon borne gas proportional counters K.Hayashida, H. Tsunemi, T. Koike, T. Horikawa (Osaka University),
Performance limits of a 55  m pixel CdTe detector G.Pellegrini, M. Lozano, R. Martinez, M. Ullan Centro Nacional de Microelectronica, Barcelona, 08193,
We report the result of a beam test on a prototype of Astronomical hard X-ray/soft gamma-ray Polarimeter, PoGO (Polarized Gamma-ray Observer). PoGO is.
1 Report on analysis of PoGO Beam Test at Spring-8 Tsunefumi Mizuno July 15, 2003 July 21, 2003 revised August 1, 2003 updated.
Hard X-ray Polarimeter for Small Satellite Design, Feasibility Study, and Ground Experiments K. Hayashida (Osaka University), T. Mihara (RIKEN), S. Gunji,
X-ray Polarimetry with gas proportional counters through rise-time
High sensitivity all sky X-ray monitor and survey with MAXI Mihara, M. kohama, M. Suzuki (RIKEN), M. Matsuoka, S. Ueno, H. Tomida (JAXA), N. Kawai, J.
The Spectrum of EM Waves According to wavelength or frequency, the EM waves can be distinguished into various types. There is no sharp boundary.
Medical Image Analysis Interaction of Electromagnetic Radiation with Matter in Medical Imaging Figures come from the textbook: Medical Image Analysis,
Polarimetry in Astronomy Or Do you know where your photons are coming from? Elizabeth Corbett AAO.
XIS Calibration at Osaka K. Hayashida, K. Torii, M. Namiki, T. Shiroshoji, M. Shoji, S. Kastuda, H. Tsunemi (Osaka University) T. Kohmura (Kougakuin University)
Takeshi Fujiwara, Hiroyuki Takahashi, Kaoru Fujita, Naoko Iyomoto Department of Nuclear Engineering and Management, The University of Tokyo, JAPAN Study.
JRA-1 ISRSI Consortium Meeting Perugia, INAF/IASF (BO,PA)
K. Jahoda, 6 Aug 2007 X-ray School, GWU Proportional Counters Some of what you should know in order to use proportional counters for Spectroscopy, Timing,
Polarization Characteristic of Multi-layer Mirror for Hard X-ray Observation of Astrophysical Objects T. Mizuno 1, J. Katsuta 2, H. Yoshida 1, H. Takahashi.
Lecture 3-Building a Detector (cont’d) George K. Parks Space Sciences Laboratory UC Berkeley, Berkeley, CA.
Electron tracking Compton camera NASA/WMAP Science Team  -PIC We report on an improvement on data acquisition for a Time Projection Chamber (TPC) based.
Goddard February 2003 R.Bellazzini - INFN Pisa A new X-Ray Polarimeter based on the photoelectric effect for Black Holes and Neutron Stars Astrophysics.
Xe-based detectors: recent work at Coimbra C.A.N.Conde, A.D. Stauffer, T.H.V.T.Dias, F.P.Santos, F.I.G.M.Borges, L.M.N.Távora, R.M.C. da Silva, J.Barata,
Quantum Efficiency Dependence on the Incidence Light Angle in Copper Photocathodes: Vectorial Photoelectric Effect Emanuele Pedersoli Università Cattolica.
1. 2 Contents The “Tsubame” Project Description of Hard X-ray Polarimeter (HXCP) Results of X-ray Beam Test Summary.
Proportional chambers with cathode readout in high particle flux environment Michał Dziewiecki.
Chapter V Radiation Detectors.
1 Chapter No. 17 Radiation Detection and Measurements, Glenn T. Knoll, Third edition (2000), John Willey. Measurement of Timing Properties.
1 Chapter No. 17 Radiation Detection and Measurements, Glenn T. Knoll, Third edition (2000), John Willey. Measurement of Timing Properties.
Nuclear Medicine Instrumentation 242 NMT 1 Dr. Abdo Mansour Assistant Professor of radiology
Conclusions References 1. A. Galimberti et al., Nucl. Instrum. Meth. A 477, (2002). 2. F. Capotondi et al., Thin Solid Films 484, (2005).
X-ray Polarimeter - POLIX: Design and development status
Instrument Parameters in WDXRF
Application of Nuclear Physics
Scintillation Counter
Computed Tomography (C.T)
Gain measurements of Chromium GEM foils
Presentation transcript:

2001/9/111 X-ray polarimetry with balloon borne gas proportional counters K.Hayashida, H. Tsunemi, T. Horikawa, Y. Nakashima (Osaka University, Japan), F. Makino (NASDA, Japan), & B. Paul (TIFR, India) Contact:

2001/9/11 2 ABSTRACT X-ray polarimetry has been an unexploited field in X-ray astronomy. Detection of the X-ray polarization was succeeded only in a few sources including Crab nebulae at 2.6keV and 5.2keV. In this paper, we present our plan of a balloon experiment for X-ray polarimetry. We will employ conventional Xe gas proportional counters with collimators. We will measure the signal rise time of each event, which reflects polarization direction of the incident X-rays relative to the anode wire direction. Ground experiments revealed that the modulation contrast (M) of this method amounts to about 0.1 at 20keV and 0.35 at 40keV (K. Hayashida et al., 1999, NIMA421, p.241). Different from scattering methods, the large effective area of gas proportional counters is exploited as it is in this method. We show that a pair of 300 cm 2 PCs is enough for detecting X- ray polarization of Crab nebulae at 20-60keV range, where no polarization measurement has been done so far.

2001/9/11 3 Anisotropic Emission of Photo-electrons K-shell photo-electrons are emitted preferentially toward the direction parallel to the electric vector of incident photons. We have been developing polarization detectors employing this principle. CCD (Tsunemi et al.,1992; Hayashida et al., 1999). Gas proportional counter risetime (Hayashida et al., 1999). Electric vector of incident photon Emission direction of photo-electron

2001/9/11 4 PC risetime polarimeter : Polarization and Anode Direction Anode Electron Cloud Rise Time = Short Rise Time = Long Anode X-ray Photon

2001/9/11 5 PC risetime polarimeter : Experiment on the Ground Polarized X-ray beam was irradiated to the Xe gas proportional counter of which anode direction was set at angle  from the E vector of the incident beam. Recently, we have developed a facility for polarized X- ray beam in our laboratory, in which electron impact type X-ray source and double crystal spectrometer are employed. (Tanaka et al., 1997, Koike et al. 2000). Hayashida et al., 1999

2001/9/11 6 Sampling the rise time of the output pulse from proportional counters Risetime was sampled from the digitized signal of the pre- amplifier output of the proportional counters. We have started developing an equivalent digital circuit using an ADC and an FPGA instead of using the oscilloscope and the computer. Hayashida et al., 1999

2001/9/11 7 PC risetime polarimeter: Results from the Ground Experiment Average of the risetime shows the modulation depending on the angle  between the beam E vector and the anode (top panel). Modulation contrast (M) of this PC risetime polarimeter for 10-40keV incidence is shown in the bottom panel. Hayashida et al., 1999

2001/9/11 8 Polarization Detector for a Balloon Experiment Merit of the PC risetime polarimeter for a balloon experiment The system will be realized with conventional gas proportional counters by adding some electronics which enable the risetime measurement. Large effective area of gas proportional counters is utilized easily without mirror system. On this point, CCD method and Thomson-scattering method are more suitable for the focal-plane polarization detector.

2001/9/11 9 Plan of the observation A pair of Xe-gas proportional counters (PC) with risetime measurement will be used. The counters will be set orthogonally so that the anode direction of one PC is parallel to the E vector of the target and another perpendicular. Target is Crab nebulae, in which P= %(2.6keV) %(5.2keV) were detected (Weisskopf et al., 1978), but no positive measurements have been done above 10keV.

2001/9/11 10 Feasibility Study: Assumptions Exposure Time=20ksec (5.6hr) Gas proportional counters Xe 1.5atm, Depth 144mm Geometrical Area of one counter in the pair Plan-A: 1200 cm 2 Plan-B: 300cm 2 M: measured values are used for 20-40keV, the value 0.35 is used above 40keV. BGD counts, escape events, air attenuation are taken into account.

2001/9/11 11 Feasibility Study: Pmin Feasibility of the observation is evaluated in terms of Pmin (minimum delectable polarization degree) for each 5 keV band. Since Crab nebulae has P=19-20% below 10keV, we expect to get positive detection for each band even with plan-B(a pair of 300cm 2 PCs)

2001/9/11 12 Calibration Facility at Osaka Polarized X-ray Beam-Line at Osaka

2001/9/11 13 Polarization Degree of the X-ray Beam with various Ex/HV We had measured the polarization degree of the X-ray beam in Koike et al., We did further experiment with higher accuracy. When we set Ex/HV~95%, we obtain P= as shown in the figure.

2001/9/11 14 Experiments at TIFR Polarized X-ray beam sources were developed at TIFR, in which X-rays with high Ex/HV are selected with absorption filters. Another system using scatters was also constructed. We have been testing a large area Xe PC counter on its polarization sensitivity through the rise time method. Small Xe PC specialized for the similar experiment is developed.

2001/9/11 15 References A precision measurement of the X-ray polarization of the Crab Nebula without pulsar contamination, Weisskopf, M.C., Silver, E.H., Kestenbaum, H.L., Long, K.S., Novick, R., 1978, ApJ, Vol.220, L117. Detection of X-ray Polarization with a Charge Coupled Device, H.Tsunemi, K.Hayashida, K.Tamura, S.Nomoto, M.Wada, A.Hirano and E.Miyata,1992, Nuclear Instruments & Methods, A Vol.321(3), p.629-p.631. How Linearly Polarized is the X-ray Beam from the X-ray Generator ?, S. Tanaka, H. Tsunemi, K. Hayashida, 1997, Jpn. J. Appl. Phys., Vol.36, p X-ray Polarimetory with a conventional gas proportional counter through rise- time analysis, K. Hayashida, N. Miura, H. Tsunemi, K. Torii, K., H. Murakami, Y. Ohno, K. Tamura, 1999, Nucl.Instr, and Methods A, Vol. 421, p Optimization of polarimetry sensitivity for X-ray CCD, K. Hayashida, S. Tanaka, H. Tsunemi. Y. Hashimoto, M. Ohtani, 1999, Nucl.Instr, and Methods A, Vol. 436, p Polarized Monochromatic X-ray Beam Extracted from Laboratory Electron Impact Source, T. Koike, K. Hayashida, Y. Hashimoto, D. Akutsu, M. Ohtani, H. Tsunemi, 2000, Proc. of SPIE, Vol.4012, p