Measurement Technique A technique was developed for measuring the radioactive concentration of breast milk samples for Tc-99m labelled radiopharmaceuticals.

Slides:



Advertisements
Similar presentations
Donor breast milk banks Implementing NICE guidance 2010 NICE clinical guideline 93.
Advertisements

Radiation Safety Training Lab Survey Program Washington State University Radiation Safety Office.
Estimation of TLD dose measurement uncertainties and thresholds at the Radiation Protection Service Du Toit Volschenk SABS.
1 MARLAP, MARSSIM and RETS- REMP: How is All of this Related…or NOT? Robert Litman, Ph.D. Eric L. Darois, MS, CHP Radiation Safety & Control Services,
Activity measurement of phosphorus-32 in the presence of pure beta-emitting impurities The CSIR Research and Innovation Conference National Metrology Laboratory.
Introduction The use of qNMR for purity measurement has been steadily growing in recent years. The assessment of the purity of calibration materials and.
Accuracy vs. Precision For each target describe whether the marks are
PHYS40422: Applied Nuclear Physics Paul Campbell Room Interaction of Radiation with Matter 2.Radiation Detection.
Data Handling l Classification of Errors v Systematic v Random.
Quality control checking of Vitamin C concentration in fruit juice
Chemometrics Method comparison
Unit #7 - Basic Quality Control for the Clinical Laboratory
Introduction to Nuclear Medicine
V. Rouillard  Introduction to measurement and statistical analysis ASSESSING EXPERIMENTAL DATA : ERRORS Remember: no measurement is perfect – errors.
Vanderbilt Pediatric Hematology Anticoagulation Guidance Protocol Robert F. Sidonio, Jr. MD, MSc. 4/12/12 Warfarin Monitoring If inpatient, consider monitoring.
Making Measurements and Using Numbers The guide to lab calculations.
International Atomic Energy Agency L 4 PROTECTION ISSUES IN CLINICAL METHODOLOGY.
Significant Figures.
How Reliable Are Measurements?
 Justification is the answer.  Dose limits are not applicable only recommened.
Author: J R Reid Extended Investigation Introduction Planning an Investigation Writing a Report Data Collection Data Processing Conclusions and Discussions.
Quantification of Ventilation Activity in V/Q Scanning Michelle Lax Lincoln County Hospital.
How big? Measurements and Significant Digits How small? How accurate?
Quality Control Lecture 5
1 Breastfeeding Promotion in NICU Z. Mosayebi Neonatologist, Tehran University of Medical Sciences.
How Science Works The following PowerPoint is aimed at enhancing skills learnt at GCSE when performing experiments. Pupils must commit the terminology.
Simulations of the double funnel construction for LET. Comparison with a single funnel The aim was to optimise the double funnel configuration to give.
Thyroid equivalent doses due to radioiodine(I-131) intake for evacuees caused by the nuclear accident in Fukushima S. Tokonami, M. Hosoda (Hirosaki Univ.)
Section 8.4 – pg  Experimental designs discussed so far have been QUALitative (flame test, solution colour, litmus test, conductivity, solubility)
 Radiopharmaceuticals are agents used to diagnose certain medical problems or treat certain diseases. They may be given to the patient in several different.
 Scientist use significant figures to determine how precise a measurement is  Significant digits in a measurement include all of the known digits.
Role of the Radionuclide Metrology Laboratory in organization of the interlaboratory comparisons for the measurement of activity (Becquerel) Maria Sahagia,
Performance Testing of Selected Liquid Scintillators Julian Dean Centre for Ionising Radiation Metrology, NPL.
Managed by UT-Battelle for the Department of Energy Residual Does Rate Analyses for the SNS Accelerator Facility I. Popova, J. Galambos HB2008 August 25-29,
Isotope Technologies Garching GmbHCERN 2010 Radiation Protection Aspects Related to Lutetium-177 Use in Hospitals R. Henkelmann, A. Hey, O. Buck, K. Zhernosekov,
O Level Physics Chapter :24: Radiation and Half Life Prepared By: Shakil Raiman.
Rachel Martin Displacement and Density. Introduction Animals are dosed by being given a specific volume of a test item (or control) formulation.
Introduction to nuclear medicine technology NMT 231 Aya Ahmed Saeed.
B ABY F RIENDLY H OSPITAL I NITIATIVE IN M ONGOLIA Dr.G. Soyolgerel Dr. Sh. Oyukhuu.
Diagnostic reference levels in Medical Imaging. Concept and practice
Why Accelerator Mass spectrometry (AMS) The determination of the concentration of a given radionuclide in a sample can be done in 2 ways: a) measure the.
CfE Advanced Higher Physics
Radiopharmaceutical Production Radionuclidic identity STOP.
Experimental Errors and Uncertainties
Radiopharmaceutical Production Radioassay STOP. Radiopharmaceutical Production Radioassay Example STOP Radioassay Acceptance Criteria: The product label.
Uncertainty2 Types of Uncertainties Random Uncertainties: result from the randomness of measuring instruments. They can be dealt with by making repeated.
Unit 4 Assignment 3 Practical techniques. Task 1 (P4) You will need to complete the following experiments. You will need to hand in a portfolio of your.
MBF1413 | Quantitative Methods Prepared by Dr Khairul Anuar 8: Time Series Analysis & Forecasting – Part 1
Nuclear Medicine Physics and Equipment 243 RAD 1 Dr. Abdo Mansour Assistant Professor of radiology
Nuclear Medicine Instrumentation 242 NMT 1 Dr. Abdo Mansour Assistant Professor of radiology
Chapter 1: The Nature of Analytical Chemistry
Measurements and Units Chemistry is a quantitative science – How much of this blue powder do I have? – How long is this test tube? – How much liquid does.
DCAQ, How to… Kris Wright Improvement & Support Team.
Notes 1.2: Significant Figures
Quality Assurance Procedure Manuals.
Unit #6 - Basic Quality Control for the Clinical Laboratory
METHODS A series of measurements were taken from six locations throughout our institution. A standard dose of F-18 was measured in addition to three standards;
Height and Pressure Test for Improving Spray Application
Learner name:   Assessor name: D Roczniak Issue date: 13/11/17
Lecture 4(Unit II): Gas-Filled Detector Quality Control
CLRS 321 Nuclear Medicine Physics & Instrumentation I
A –Level Physics: Accuracy + Uncertainty
Choice of Methods and Instruments
Instructions for Wipe Testing for Radioactive Material Contamination
Comparing the Matrix and EPID Flatness/Symmetry/Output Measurement
How Science Works The following PowerPoint is aimed at enhancing skills learnt at GCSE when performing experiments. Pupils must commit the terminology.
Using Scientific Measurements
Understand Accuracy and Precison
Computed Tomography (C.T)
Radiopharmaceutical Production
Presentation transcript:

Measurement Technique A technique was developed for measuring the radioactive concentration of breast milk samples for Tc-99m labelled radiopharmaceuticals. It utilises equipment that can be commonly found in most Nuclear Medicine departments. Key to the accuracy of this technique is consistency in positioning and geometry. Initial Setup A ‘Standard’ sample of Tc-99m (approx. 5 MBq) in a 2 ml volume is prepared. This is placed in a flat bottomed cylindrical plastic tube and measured inside a radionuclide calibrator. The radionuclide calibrator should comply with the quality control requirements set out in Good Practice Guide No. 93 [3]. A NaI scintillation probe (Radhound SS404 Al Sodium Iodide Scintillation Probe), as commonly used by Nuclear Medicine departments for contamination monitoring, is then positioned on a workbench (Figure 1). The detector is secured and its position marked in such a manner that it can either not be moved or can be accurately repositioned when required. Dr Ewan Eadie Department of Nuclear Medicine, Ninewells Hospital and Medical School, Dundee, DD1 9SY Milk Metrology: A Simple Technique for Measuring the Radioactive Concentration of Breast Milk Secretion of radioactivity in breastmilk Following the administration of a radiopharmaceutical, mothers may be required to interrupt breast feeding in order to reduce the radiation dose to the child from excreted radioactivity. Interruption periods for a range of radiopharmaceuticals are specified in the ARSAC Notes for Guidance [1]. However the published data on feeding interruption is limited and there is wide variation in the reported excreted activities [2]. With appropriate measurement it may be possible to reduce the feeding interruption time. Measurement of radioactive concentration in breast milk is not routinely performed. This may be because of a lack of access to the equipment needed. The measurement technique described here should be accessible to all Nuclear Medicine departments. System Tests A number of tests were carried out to determine the uncertainties associated with this measurement technique. The largest of these are listed below. Comparison The results from this measurement technique were compared to a Multi-Channel Analyser (Ortec digiBase). Average difference = 1.0% Maximum difference = 3.7% Patient Sample To date, only a single patient sample has been measured. This is mainly due to logistical problems accessing the samples. The concentration of the patient sample was: Contamination monitor technique: 37.5 kBq ml -1 Multi-Channel Analyser: 37 kBq ml -1 The sample was taken four hours post administration of Tc-99m MAA. Had the infant been allowed to resume feeding after this sample they would have received an effective dose of 1.2 mSv, based on 140 ml feeds separated by four hours [1]. However as no further measurement was possible, the mother was advised a standard interruption to feeding of 12 hours. Conclusion Nuclear Medicine departments are encouraged by the ARSAC Notes for Guidance to measure the radioactive concentration of breast milk following the administration of a radiopharmaceutical. The technique described here can easily be employed by any Nuclear Medicine department. The uncertainty in the final result is acceptable, especially when put within the context of the assumptions made about ingested volume. Measurement has shown good agreement between this technique and a multi-channel analyser. Future Work Access to patient samples is a major obstacle in performing measurements on the radioactive content of breast milk. To tackle this I would like to design a system that could be employed on post- natal wards, allowing the midwives to carry out the measurement and determine when feeding can resume. Recent work by PHE suggests external radiation dose from close contact with mother would increase feeding interruption by 1 hour for Tc-99m MAA [4]. Linearity (25 – 400 counts s -1 )13% (Ave. difference) Repeatability (Long Term)6% (CoV) Variation between users5% (CoV) Repeatability (Short Term)4% (CoV) Repeatability (Daily)4% (CoV) Source Placement2% (CoV) Detector Placement1% (CoV) The ‘Standard’ sample is positioned at a distance of 30 cm from the front window of the NaI probe. The position of the ‘Standard’ is also marked for consistency. This is done by drawing round the bottom of the tube (Figure 1). The ‘Standard’ is left to decay until the concentration is approximately that expected from a breast milk sample (i.e. 50 kBq ml -1 ). Once decayed, an average of ten background measurements and ten ‘Standard’ measurements are performed. This provides a background corrected sensitivity calibration in counts per second per kBq (counts s -1 kBq -1 ). Breast Milk Measurement It is important that the breast milk sample is measured with precisely the same positioning and geometry as the ‘Standard’. Therefore 2 ml of the milk sample is withdrawn (or the volume is increased to 2 ml depending upon the supplied sample) and placed inside another flat bottomed cylindrical tube. The tube is placed within the pre-marked circle and ten measurements are taken. From these measurements the concentration of the breast milk sample in kBq ml -1 is calculated. Once the concentration is known it is possible to determine the effective dose to the infant. Figure 1: Photograph of measurement setup References [1] Notes for Guidance on the Clinical Administration of Radiopharmaceuticals and Use of Sealed Radioactive Sources. Administration of Radioactive Substances Advisory Committee (revised 2014). [2] Stabin, M.G. and Breitz, H.B. Breast Milk Excretion of Radiopharmaceuticals: Mechanisms, Findings, and Radiation Dosimtery. J Nucl Med. 2000; 41: [3] A National Measurement Good Practice Guide No.93: Protocol for Establishing and Maintaining the Calibration of Medical Radionuclide Calibrators and their Quality Control. National Physical Laboratory [4] Fraser, L. and Evans, W. D. Calculation of interruption times for breastfeeding following the administration of radiopharmaceuticals to patients. Presented at BNMS Harrogate 2014.