Omicron LT UHV STM Do’s and Don’ts. General (Instrument) Eye protection should be worn when near to a viewport, even if using protective covers. Never.

Slides:



Advertisements
Similar presentations
The drill press is the preferred tool for making holes in materials.
Advertisements

Filter Changing Procedures For TEOM Series 1400ab and Model 8500 FDMS (B & C Types)
Student Overview MMS Wireless Mobile Lab. Removing the laptops from the cart Each laptop is numbered. Each slot in the cabinet is numbered. Pick up your.
Safety Curriculum Project ChildSafe Putting A Lock On Safety! A nationwide program of the National Shooting Sports Foundation and its community partners.
Brio 2000 / Brio 2000-M E-Learning Service Manual Rev. 0.0.
Refrigerators.
Power Tools Safety. Portable Circular Saws Stock must be well supported in such a way that the kerf will not close and bind the blade.. Thin materials.
Servicing Welch DRYFAST ULTRA Pump Models 2032
3.1.9 Student Book © 2004 Propane Education & Research CouncilPage Replacing Valves and Fittings in ASME Tanks Replacing ASME tank valves and fittings.
1 FUEL SYSTEM SERVICE ENGINE CLEAN FUEL TOOL MODEL RX 777.
Sand Sampler User’s Manual Introduction Things to Know Before Starting your Sampler Starting and Operating Troubleshooting Maintenance.
Stanley DS11 Diamond Saw.
Installation. Indoor Unit Installation Typical Installation.
How to carry out experiments using MPMS March 2012 Takeshi NAKAGAWA.
Split steering gaiter (nearside) this is an MoT failure.
MyLock 644D Service Seminar.
Milling Machine Setups
© Blue Graphics Concept Sauer-Danfoss START-UP PROCEDURE PROPEL PUMP Instruction Sauer-Danfoss Belgium – T. Van Mossevelde.
Bellow valve (trap&pump) Inside glove box. (Note: Ar glove box is not necessary, if you work with single crystalline organic materials like rubrene that.
2.3.9 Student Book © 2004 Propane Education & Research CouncilPage Identifying Procedures for Purging Containers & Injecting Methanol Prior to.
Section 2 Safety, Tools and Equipment, Shop Practices Unit 4 General Safety Practices.
Tool removed during cycle Fault #2 Conditions for setting Tool cocked prox switch goes open during cycle AND force on load cell drops below limit in fault.
Terms and Definitions Base Metal: Metal to be welded Fusion Welding: process that joins metals by heating them to a melting point and allowing them to.
Omicron LT UHV STM Do’s and Don’ts. General (Instrument) Eye protection should be worn when near to a viewport, even if using protective covers. Never.
1 ENVIRONMENTAL ENERGY TECHNOLOGIES DIVISION JUNE 24, 2013 Hand Tool Safety.
ResQmax Line Deployment Kit -ResQmax Launcher- 5 nozzle protectors -2 Streamline Projectiles- O-ring kit -500’ 3mm line with container- Corrosion block.
If you use your computer more than a few hours per day, we suggest you not to turn off your computer at the end of the day. Instead turn off only the.
Clean Air Box Usage & Care CABs RAMs CO Monitors.
Sunday, May 17, 2015 Pressure Booster Service. Sunday, May 17, 2015 Booster Service Basics Control Panel Components Setting a pressure switch Setting.
Skills Instruction Backpacking Stoves Your Name Troop Guide N Totem Here.
Service Seminar Memory Craft Table of Contents MC10001 Top Cover Removal…………………………………………………………………..…………1 Belt Cover Removal……………………………………………………………..……………2-4.
1. Pump down the chamber from the atmosphere pressure 2. Using RHEED to obtain diffraction images 3. Open the RHEED chamber or venting from high vacuum.
Actuators.
Equipment Familiarization Amatrol 850 Basic Hydraulic Training System
Introduction to Operation of the XL- 30 Scanning Electron Microscope Tutorial # 2 Introduction to Operation and Imaging.
Chapter 8Basic Computer Maintenance  8.1Preventive Maintenance 8.1Preventive Maintenance 8.1Preventive Maintenance  8.2Monitoring System Performance.
Fuel Oil Systems Fuel Oil Systems consist of: Storage Tanks Pumps
Hydronic Mechanical Controls
Micro Practical 3 PRINCIPLE AND WORKING OF AUTOCLAVE Dr. Shahzad Ali Assistant Professor Department of Wildlife and Ecology UVAS, Ravi Campus, Pattoki.
How To Replace Your Fuel Filter On a 1998 Mustang GT.
2006 Hand and Power Tool Safety Basic Rules for Rube Goldberg Competition,
1 Battery Safety, Servicing & Testing R. Bortignon.
Annual Refresher Training Tools and Machine Guards.
I.C. ENGINES Practical No: 1 (17 Mar, 2014). Measurement of Cylinder Pressure If your vehicle has been running roughly or losing power, there may be a.
Drills and Drill Press Safety in the Lab
Safety Rules for 9 th Grade Shop Radial Arm Saw: Safety Rules Never cut a board that is less than 12 inches long. Always pull the saw using the handle;
Introduction to Soldering
Flex Cam – Training This shows one version of a complete FlexCam system including Power Unit HCP and Compact Cam CC for piercing operation.
T. Trimpe Body Tube Nosepiece Objectives Stage Clips Light Ocular lens (Eyepiece) Arm Stage Coarse Adjustment Fine Adjustment.
Unit 4: General Safety Practices
Clearing Procedures. DISASSEMBLY Major Groups Barrel Group Turn the cover latch and raise the cover group Grasp the retracting slide handle with the.
What tests are necessary to make sure your kegs are being cleaned, sanitized and filled correctly By Andrew J. Brewer
Fabrication of Fishtank Reservoir ENGR 121 living with the lab.
Tool Removed During Cycle Fault #2 Conditions for Setting Tool cocked prox switch goes open during cycle AND force on load cell drops below 5 lbs. Active.
AfterSalesTraining Welcome to AfterSalesTraining.
Rapid Change Technology The following is a presentation to aid Technicians in the replacement of the Rapid Change Technology Block.
STORAGE AND MAINTENANCE OF LARGE FARM EQUIPMENT Prepared by : Von G. Peavy South Region Ag Mechanics.
Air condition installation
Working with Ultra High Vacuum (UHV) Equipment
OBJECTIVES Discuss the various methods of loosening the brake bleeder valve. Discuss the need for brake bleeding. Describe the manual bleeding procedure.
Fault detection Lecture (1).
Actuators & Directional Control Valves
Student CD for Commercial Refrigeration for A/C Technicians Chapter 12 Ice Machines.
Fuel Supply System Service
Safety Training Molecular Materials Research Center Beckman Institute
Cryomodule Assembly Plan
Correct Procedures for Changing, Storing, and Maintaining Saw Blades
Presentation transcript:

Omicron LT UHV STM Do’s and Don’ts

General (Instrument) Eye protection should be worn when near to a viewport, even if using protective covers. Never touch any UHV surfaces with bare hands. Always use clean polythene gloves and degreased tools. Don’t touch table when it’s floating on air legs. Always be aware of which panel you’re dealing with (STM vs. Prep Chamber). Avoid burst valve on STM chamber. Remember that sample transfers have greatest potential for disaster. Never forget to update contents of carousel Never turn on ion pumps or gauges when pressure is >1x10 mbar Never stand on compressed air lines or let them get loose. -6

General Instrument continued Do not vent the chambers with ion pumps, ion gauges or STM on. Never flash the TSP with a clean sample in the chamber. Turn the TSP off on the control panel after it turns off in the chamber. Never turn off the sample heather without turning the dials on the panel all the way to zero. Never put large forces on the position handle on top of the STM. Never use the tunneling position, where STM is hanging freely, when moving the STM, operating the wobblestick, or during bakeout. Do not forget to take the cap off of the Helium cylinder before it’s returned to the Airgas company.

General (Nuts & Bolts) Do not use tools made from Ni-alloys when handling silicon samples. Steel and stainless steel contain sufficient amounts of nickel to contaminate the sample. Omicron recommends using molybdenum or ceramic tools. Never use a stainless steel sample plate at high temperatures, such as during degassing, in order to avoid nickel contamination in the UHV system. Use a tantalum sample plate. Use only the originally supplied molybdenum wrench for tightening the molybdenum nuts. The sample holders are delicate – use care when changing sample

General (Matrix) Do not press buttons while the matrix loads. Avoid excessive button-pressing after matrix has loaded. Be sure to load the experiment, change the Raster setting to Single Point, and choose the correct temperature settings after loading matrix. When a line scan is unresponsive, close it out and open another by duplicating the topology screen. Use the coarse movement remote box to move the scanner close to the sample, but use the auto-approach option in matrix when approaching.

Wobblestick The wobblestick can be moved to and fro, up and down and sideways, but should never be rotated. Avoid damage to bellows as to prevent vacuum leaks: – Do not scratch the wobblestick bellows at parts of the cryostat, carousel or chamber. – Do not bend the wobblestick too heavily to avoid deformations to the sleeve. If movements prove difficult try gently wobbling the wobblestick. – Always use small angle wobblestick movements. Never use wobblestick without fully retracting tip, or there is a danger of snapping off the scan tube. Never use wobble stick if STM stage isn’t locked in cold position. During a transfer, do not move the wobblestick up and down, as it will damage the sample holder clips. Always be sure that the wobblestick is secure after use, by wobbling it back and forth. Stay away from wobblestick when not in use.

Bakeout Maximum bakeout temperature: 150°C. Bring the LT STM to its bakeout position before starting a bakeout procedure or the suspension springs may extend and cause major problems to the eddy current damping system. Never bake in the cool-down position or the STM stage may stick to the chamber. Never leave a sample plate in the STM during a bakeout, because the clips could be damaged. Never use the Si diode for bakeout temperature control (considering the weak thermal coupling between SPM head and system during bakeout).

Bakeout continued In order to avoid charge build up during bakeout due to the pyroelectric effect fit all FT12/19 feedthroughs with their short circuit plugs. Remove all non-bakeable parts from the system (including the LHe cryostat fast coupling port and LHe probe) and check the table for loose plastic. Shield all viewports with aluminium foil. Never bake with the magnets on the sputter gun or the transfer arm in the load lock. Figure 28 (from manual) FT 12 connectors

Cool Down The sample stage must stay locked in the cool-down position with the STM firmly against the cryostat to ensure maximum thermal contact for cool-down process. The scanner should not be operated at temperatures above 50°C, because it may lead to a depolarization. Do not let N 2 vents get blocked or clogged with ice. Never leave liquid Helium cylinder with all vents shut (apart from transfer itself). Do not bend the LHe probe. The thin superconducting wire and stainless steel support tube are very fragile. Never scan > 200 nm when at 4 K. Never scan > 300 nm when at 77 K. The vacuum must be in the lower mbar regime to avoid residual gas particles adsorbing upon the cold sample surface. The surface sticking probability is close to 1 for temperatures of 10 K and below.

LHe Fill Procedure 1. Always fill any cryogen with the quiet room door(s) open for ventilation 2. Always wear safety glasses and cryogen appropriate gloves 3. Double check the extender on the long end of the transfer rod is tightened (it loosens after every fill) 4. Check pressure inside 60 L or 100 L liquid helium storage dewar with pressure gauge connected to the vent valve. Release any pressure that is above 0.5 psi. 5. Close all vent valves and open the top valve. Open the inlet of the inner cryostat of the LT-STM. Put LT in bakeout position. 6. Slowly insert the transfer rod in the storage dewar and in the inner cryostat, keeping the bellows horizontal at all times. 7. Monitor pressure of storage dewar with the pressure gauge during the fill. It can fill on its own at 0.5 psi. If additional “pushing” is needed, do not push higher than 1 psi. Only use helium gas to push, all other gases will freeze! 8. Once fill is complete, remove the helium gas line and open the vent valve to release pressure. Remove transfer rod from storage dewar and inner cryostat of LT-STM. 9. Close all valves and open the road safety valve. Added 4/6/16

Setup The allowed tip length is limited. The tip must not stick out more than 2 mm above the tip holder tube. During loading of sample and tip holder, make sure the scanner is fully retracted and at its lowest position, and lock stage. When transferring a sample, do not use up or down movements with the wobblestick, and check that the sample plate is rigidly clamped when fully inserted. Avoid running the coarse motors on the spot, e.g. at their limits, for longer periods of time. When changing temperatures with the tip in tunneling distance there is an increased danger of tip crash. Constantly observe the Z-position and be prepared to retract the tip with the coarse motion drive.

Setup Electronics Switch off all units, disconnect mains and wait for a few minutes (for discharge of the power supplies) before connecting or disconnecting any cables. Never connect or disconnect the preamplifier supply voltage with the MATRIX CU switched on. Never have the LT STM connected to the electronics in the corona pressure region, i.e. between to mbar so as to avoid damage due to corona discharge.

Data Management When scanning: – To save space, attempt to not save bad images – pressing start and stop for the experiment seems to work well. – Make a note in the notebook for every image that is saved, including the scan cycle number. It saves time when the Image Metrology Explorer is not opened. Instead open files through D:drive/OmicronNanotechnology/Matrix/default/Results Images are saved with the following file names: – User_date-time_project-experiment_count.mtrx where the user is default, the project-experiment is STM- STM _Spectroscopy, and the count is the run number_scan cycle. Each time start and stop is pushed (a new experiment is started), the run number increases by one.

Data Management cont. Each scan cycle is saved (up/forward, up/backward, down/forward, down/backward) and when one of those images is deleted, the others could be corrupted. Rather than deleting, files will be moved to different folders on a biweekly or monthly basis, sorted by date. It seems however, that images need to be moved back to the Results folder in order to be opened correctly in SPIP. (Upon opening a file with the Heuristic File Importer, the parameters of the image are guessed, and if we know the parameters, the image should open correctly.) Files currently can not be opened with WSxM program.