Methodology for Molecular weight determination by MALDI instrumentation One of the application of MALDI is for the determination of the molecular weight.

Slides:



Advertisements
Similar presentations
FC-MS from Teledyne Isco CombiFlash ® a Name You Can Rely On.
Advertisements

Logical Operations on Images Boolean logic is a system of logical operations defined by George Boole in the mid 19th century to apply algebraic operations.
Methodology for the Removal of abundant protein from the serum “Complex biological samples like serum requires a multistep robust protocol to remove the.
High Boost filtering In image processing, it is often desirable to emphasize high frequency components representing the image details without eliminating.
Evaluation of Peptides in Wisconsin Beer Mckenna L. Missfeldt, Dr. Jennifer Grant, University of Wisconsin-Stout Abstract Matrix-assisted laser desorption/ionization.
MALDI-TOF Mass Spectrometry and Introduction to Proteomics Dr. Steve Hartson Oklahoma State University Dept. Biochemistry and Molecular Biology Recombinant.
Laser Desorption Ionization Mass Spectrometry of Ink Katie Axwik Jory Schlitt Broc Glover.
Lecture 9. MALDI/TOF. Introduction Matrix-assisted laser desorption/ionization (MALDI) is a soft ionization technique used in mass spectrometry, allowing.
Peptide Mass Fingerprinting
MALDI MS Imaging on the 4800 MALDI TOF/TOF™ Analyzer Prepared by Andrew James, PhD.
Mass Spectrometry in the Biosciences: Introduction to Mass Spectrometry and Its Uses in a Company Like Decode. Sigurður V. Smárason, Ph.D. New Technologies.
PROTEIN IDENTIFICATION BY MASS SPECTROMETRY. OBJECTIVES To become familiar with matrix assisted laser desorption ionization-time of flight mass spectrometry.
Mascot: an introduction Basics oWhat is Mascot? oIt is a search engine which uses mass spectrometry (MS) data to identify proteins.
Molecular Mass Spectrometry
Basics of 2-DE and MALDI-ToF MS
My contact details and information about submitting samples for MS
Hamming Code A Hamming code is a linear error-correcting code named after its inventor, Richard Hamming. Hamming codes can detect up to two bit errors,
SDS-PAGE gel analysis SDS-PAGE analysis is done to study the expression of a protein from the control and the sample, to detect the molecular weight of.
Matrix-Assisted Laser Desorption Ionization Time of Flight (MALDI TOF)
Ogden Air Logistics Center. Purpose of Excel2FV Many agencies produce point lists of different data (target lists, force locations, etc.) in either Excel.
Syndrome Decoding of Linear Block Code
Affinity Chromatography Affinity chromatography is based on the principle of specific interaction between the protein or antigen and antibody for separation.
Segmental Mobility – Region of Viscoelasticity  Related LOs: > Prior Viewing – Single Chain Conformation-Ideal Chain > Future Viewing – Unit cells in.
Mass Spectrometry I Basic Data Processing. Mass spectrometry A mass spectrometer measures molecular masses. The mass unit is called dalton, which is 1/12.
INF380 - Proteomics-61 INF380 – Proteomics Chapter 6 – Mass Spectrometry – MALDI TOF The MALDI-TOF instruments are the simplest MS instruments suitable.
1 Chemical Analysis by Mass Spectrometry. 2 All chemical substances are combinations of atoms. Atoms of different elements have different masses (H =
MALDI demonstration Frímann, Helgi, Long, Nanna. Sample preperation The sample of interest and matrix are dissolved in a volatile solvent The sample/matrix/solvent.
In-Gel Digestion Why In-Gel Digest?
Welcome This is a document to explains the chosen concept to the animator. This will take you through a 5 section process to provide the necessary details.
The Future of Time-of-flight Mass Spectrometry
Gel Filtration Chromatography The method mostly involves the separation of the proteins based on its molecular size. This method is also known as Size.
Electrical Resistivity in Superconductors The electrical resistivity of many metals and alloys drops suddenly to zero when the specimen is cooled to a.
Separates charged atoms or molecules according to their mass-to-charge ratio Mass Spectrometry Frequently.
 Related Los: Dye binding properties > Prior Viewing – IDD-17. SDS-PAGE, IDD-18. Second dimension separation of proteins > Future Viewing – IDD-22. 2D-gel.
Edge Detection using Laplacian of Gaussian Edge detection is a fundamental tool in image processing and computer vision. It identifies points in a digital.
CSMA/CA Simulation  Course Name: Networking Level(UG/PG): UG  Author(s) : Amitendu Panja, Veedhi Desai  Mentor: Aruna Adil *The contents in this ppt.
Welcome This is a document to explains the chosen concept to the animator. This will take you through a 5 section process to provide the necessary details.
Gaussian Smoothing Gaussian Smoothing is the result of blurring an image by a Gaussian function. It is also known as Gaussian blur.  Course Name: Digital.
CSMA/CD Simulation Carrier Sense Multiple Access (CSMA), although more efficient than ALOHA or slotted ALOHA, still has one glaring inefficiency: When.
Linear Search Linear Search is a fundamental search algorithm. Linear search, also known as sequential search, is a process that checks every element in.
Median Filtering In signal processing, it is often desirable to be able to perform some kind of noise reduction on an image or signal. The median filter.
Electrical Resistivity in Superconductors The electrical resistivity of many metals and alloys drops suddenly to zero when the specimen is cooled to a.
Go-Back-N ARQ (Sliding Window Protocol) Go-Back-N is an instance of the Automatic Repeat-request (ARQ) Protocol, in which the sending process continues.
2014 생화학 실험 (1) 6주차 실험조교 : 류 지 연 Yonsei Proteome Research Center 산학협동관 421호
Workflows to set up acquisition methods for scheduled sMRM-HR on the TripleTOF 5600 Start from a data dependent acquisition (DDA) Perform data base search.
What is Mass Spectrometry? Mass spectrometry could be considered as an analytical technique that involves the study in the gas phase of ionized molecules.
RANIA MOHAMED EL-SHARKAWY Lecturer of clinical chemistry Medical Research Institute, Alexandria University MEDICAL RESEARCH INSTITUTE– ALEXANDRIA UNIVERSITY.
Related Los: Eexcitation and Emission property, Pixels > Prior Viewing- IDD-11. Protein quantification, IDD-13. Cyanine dye labeling, IDD- 14. Isoelectric.
Yonsei Proteome Research Center Peptide Mass Finger-Printing Part II. MALDI-TOF 2013 생화학 실험 (1) 6 주차 자료 임종선 조교 내선 6625.
Sub-Cellular Fractionation
Peptide Mass Finger-Printing Part II. MALDI-TOF
Methodology for the analysis of the data of the separated proteome
Mass Spectrometry 101 (continued) Hackert - CH 370 / 387D
Ion Exchange Chromatography
MALDI-TOF MS Bergdís Björk Bæringsdóttir Daníel Arnar Tómasson
Methodology for the Quantification of protein
Methodology for the labeling of proteins with cyanine dyes
Methodology for LC-MS/MS data analysis
Time-of-Flight Mass Analyzers
Prof. Saravanan Vijayakumaran
Welcome 1 This is a document to explains the chosen concept to the animator. This will take you through a 5 section process to provide the necessary details.
Mass spectrometry Detection of ionic species to determine the molecular weight of and obtain structural information on a molecule.
Closing One of the important morphological operations applied to either grayscale or binary images is Closing. It is derived from the fundamental operations.
Binary Search A binary search algorithm finds the position of a specified value within a sorted array. Binary search is a technique for searching an ordered.
Sorted Linked List A linked list is a data structure that consists of a sequence of data records such that in each record there is a field that contains.
Mass Spectrometry THE MAIN USE OF MS IN ORG CHEM IS:
Welcome 1 This is a document to explains the chosen concept to the animator. This will take you through a 5 section process to provide the necessary details.
M.Prasad Naidu MSc Medical Biochemistry, Ph.D,.
Opening One of the important morphological operations applied to either grayscale or binary images is Opening. It is derived from the fundamental operations.
Image Sharpening using Laplacian
Presentation transcript:

Methodology for Molecular weight determination by MALDI instrumentation One of the application of MALDI is for the determination of the molecular weight of the peptide and protein, which can be done from the peptide mass fingerprint or from the spectrum  Related Los: Laser properties, Matrix properties > Prior Viewing – IDD-27. In gel digestion, IDD-29. Matrix preparation for MALDI analysis, IDD-30. Matrix Instrumentation > Future Viewing – IDD-31. MALDI-TOF data analysis, IDD-45. Proteomic Profiling Global  Course Name: Molecular weight determination by MALDI instrumentation  Level(UG/PG): PG  Author(s) : Dinesh Raghu, Vinayak Pachapur  Mentor: Dr. Sanjeeva Srivastava *The contents in this ppt are licensed under Creative Commons Attribution-NonCommercial-ShareAlike 2.5 India license

Learning objectives After interacting with this learning object, the learner will be able to: 1. Operate the MALDI instrumentation 2. Analyze the mechanism behind the MALDI-MS analysis 3. Calculate the molecular weight of the protein 4. Assess the troubleshooting steps involved in the experiments

Master Layout Sample loading Parameters setting Firing of spots Spectrum analysis Slide Slide 7 -9 Slide 6 Slide 5

Definitions and Keywords Mass Spectrometry (MS): is a analytical technique used to measure intrinsic property of a bio-molecule, its mass, with very high dynamic sensitivity. 2. Matrix Assisted Laser Desorption Ionization (MALDI): MALDI is effective ionization system for generating gas-phase ions of proteins and peptides for mass spectrometric detection. The analyte of interest is embedded in dried matrix-sample is exposed to pulses from a UV laser for further separation and detection. 3. Spectrum data: is nothing but the collection of data in the mass to charge ratio plotted along the X-axis and its intensity on Y-axis.

Step 1: T1: Sample loading Audio Narration (if any) ‏ Description of the action/ interactivity Take the user through the slides of IDD-29. Matrix preparation for MALDI analysis. Let user take the apomyoglobin sample as known standard for the analysis.

Step 2: T2: Parameter settings Audio Narration (if any) ‏ Description of the action/ interactivity Take the user through the slides of IDD:30 MALDI instrumentation. Animate the steps from the same IDD till the firing step for sample. Let user take the sample as apomyoglobin as known standardand spot it on the MALDI plate.

Step 3: T3: Firing of spots Audio Narration (if any) ‏ Description of the action/ interactivity Now let user select the actual target spot, by right-click on yellow region, and specifing the target spot and clicks on Fire button. Animate initially low peaks, now let user makes fine adjustment with 5 buttons, make movement in camera view also, now display more peaks with much high intensity. Let user keep playing around to complete 100 profiles. Now highlight Store button, after user click, let user have option to save the data. User must play around the spot region to find sweet spot, where the peaks are more in number with high intensity. After the 100profiles user can save the data.

Step 3: T3: Firing of spots Audio Narration (if any) ‏ Description of the action/ interactivity Now user can select some other spot and start firing like in previous slide. In between firing, if user likes to pause, user hav a option like Abort, Resume. In case the peaks obtained are not fine, user can click on “abort” and click on “clear data” to clear all the data collected to re-start again. In between firing user have option for abort, resume, suspend and clear data. User can select these options depending on the profile data obtained.

Step 3: T3: Firing of spots Audio Narration (if any) ‏ Description of the action/ interactivity In most cases the default parameters for peak processing are best suited. If user is not okay with the data collected, user can make peak processing with the required settings. Instruct user to carry out peak processing. Let user select Processing> peak processing. Display peak processing with user controls. Let user have option for methos selection, baseline subraction, threshold, average display of profiles.

Step 4: T4: Spectrum analysis Audio Narration (if any) ‏ Description of the action/ interactivity After peak processing the data is ready to be saved and exported. Let user select File>Export>ASCII. A small window display for user control must pop up. Let the user selects the default values ad clicks on Save as.. to open the Save As window. Browse to your desired location, enter a File name, and click ‘Save’. The PMF data will be saved. Once the PMF data is ready, data in the excel format can be exported, and saved.

Step 4: T4: Spectrum analysis Audio Narration (if any) ‏ Description of the action/ interactivity Instruct user to calculate the molecular mass. let user select any two peaks. For example in the figure highlight x1 and x2. let user make a note of it. The mass can be calculated from any two peaks by taking the difference and applying the formulas.

Step 4: T4: Spectrum analysis Audio Narration (if any) ‏ Description of the action/ interactivity Instruct user to calculate the molecular mass. Display the above 4 equation. Now that user knows x1, x2 and mH is 1, user can calculate the value for Z by equation 3. now all the values must be put in equation 4 to calculate the value for M. Animate the steps. M:molecular mass of the analyte molecule. x1: m/z ratio of the analyte molecule with z protons. X2: m/z ratio of the analyte molecule wit (z+1) protons. mH: mass of hydraogen ataom

Step 4: T4: Spectrum analysis Audio Narration (if any) ‏ Description of the action/ interactivity Instruct user to calculate the molecular mass. With the values of x1=998.2 and x2= deduce the calculation of mass for apomyoglobin. The mlecular mass of apomyoglobin is around u. This can be cross checked by doing the data analysis through MASCOT serach. mH: mass of hydraogen ataom

Step 4: T4: Spectrum analysis Audio Narration (if any) ‏ Description of the action/ interactivity In similar way molecular mass of a given spectrum of a particular protein can be calculated easily. In case of confirmation the same spectrum can be analysed through the MASCOT engine. For more information please go through future viewing IDD. In similar way provide few x1 and x2, or let user choose few peaks and their values to calculate the molecular mass.

Animation area In slide-14: if user is unable to find the Molecular weight from the spectrum. Instruction: let user note down the peaks and carry out MASCOT search to get the Molecular weight from the database. Instructions/ Working area Credits Name of the section/stage Interactivity area Tab 01Tab 02Tab 03Tab 04Tab 05Tab 06 Button 01 Button 02 Button 03 Introduction Slide Slide 7 -9 Slide 6 Slide 1-4 Slide 5

Questionnaire: APPENDIX 1 Question 1 The moleclar weight of apomyoglobin? a) 16kDa b) 10kDa c) 11kDa d) 5kDa Answer : a) 16kDa Question 2 In time of flight, analytes are separated depending upon? a)Distance travelled b)Velocity of alalyte c)Mass d)Non of above Answer:c) Mass

Questionnaire: APPENDIX 1 Question 3 For higher molecular weight proteins, separation is best in? a)Reflectron mode b)Linear mode c)Acquisition mode d)Laser mode Answer : a) Reflectron mode Question 4 Which of the following is not a mass analyzer? a) Time-of-Flight (TOF) b) Quadrupole (Q) c) Ion traps d) MALDI Answer: d) MALDI

Questionnaire: APPENDIX 1 Question 5 The wavelength of laser used for ionization? a) 337nm b) 437nm c) 537nm d) 637nm Answer: a) 337nm 6. Question 5 MALDI is a a) Soft ionization technique b) Hard ionization technique c) Both of them d) None of them Answer a) Soft ionization technique

Links for further reading Papers: 1.Hillenkamp F, Karas M, Beavis RC, Chait BT. Matrix-assisted laser desorption/ionization mass spectrometry of biopolymers. Anal Chem. 1991, 63, 1193A-1203A. 2. Karas M, Glückmann M, Schäfer J. Ionization in matrix- assisted laser desorption/ionization: singly charged molecular ions are the lucky survivors. J Mass Spectrom. 2000, 35, Hillenkamp F, Karas M. Mass spectrometry of peptides and proteins by matrix-assisted ultraviolet laser desorption/ionization. Methods Enzymol. 1990, 193, Books:  Proteomics: A cold spring harbor laboratory course manual by Andrew J L and Joshua L, APPENDIX 2

Summary APPENDIX 3 MALDI-MS instrument helps to determine or calculate molecular weight of an protein by just going through the spectrum data. The rough estimate from the spectrum data for molecular weight determination helps user to save lot of time and carry out further analysis by selecting each peak properly.