Video: Fire Hydrant Time: 1:01 Chap 14-1

Slides:



Advertisements
Similar presentations
Chapter 12 Lesson Goal After completing this lesson, the student shall be able to make hydrant connections and draft from a static water source according.
Advertisements

Fire Apparatus Pump Theory
DESIGN LAYOUT OF DISTRIBUTION SYSTEMS
Chapter 12 Lesson Goal After completing this lesson, the student shall be able to make hydrant connections and draft from a static water source according.
Learning Objective 1 Describe the safety considerations taken when service testing a fire hose.
Buildings and Structures 2 Fixed Installations Aim To provide students with information to allow them to recognise the types of fixed fire protection.
1 WATER SUPPLY DISTRIBUTION On completion of this module you should be able to Describe pipe structures, types and installation design gravity and rising.
BS9990 : 2015 Updates and/or Changes
Pumping Apparatus Driver/Operator
Chapter 12 Systems and Equipment for Fire Protection.
LoneStar Fire Specialties
Pumping Apparatus Driver/Operator
CVFD Training – Water Supply SFFMA Training Objectives: –
Fire Streams SFFMA Training Objectives: –
FIREFIGHTER I LESSON 15. SPRINKLER SYSTEM DESIGN AND OPERATION Series of sprinklers arranged to automatically distribute enough water to extinguish or.
Characteristics of Water
WATER SUPPLY Copyright© Delmar is a division of Thomson Learning.
Purpose of Standpipe and Hose Systems
Chapter 9 Water Supply.
CE HYDRAULICS ENGINEERING
1402 Hybrid Firefighter I 6 th Edition Chapter 14 Water Supply.
Chapter 9 Water Supply.
C L A S #4 Driver Operator Refresher Training.
Pumping Apparatus Driver/Operator
Installing & Maintaining Irrigation Systems Ms. Gripshover Landscaping Unit 15.
Basic Hydraulics Irrigation.
Water Supply 1. Water Supply Components
Intermediate SFFMA Objectives: – Hrs received.
Mechanical for Oil Heat
Module C Sprinkler systems (4-20)
Learning Objective 1 Explain the ways water supply system components are used by firefighters.
Distribution System Control Strategies.  Tank Management/Operations  Flushing  Rerouting Water  Others  optimizing existing booster chlorination.
Assignment No. 1 [Grup 8] Figure below shows a portion of a hydraulic circuit. The pressure point B must be 200 psig when the volume flow rate is 60 gal/min.
Water Supply.
1. 2 Introduction We continue to develop new methods and materials for extinguishing fires Water still remains the primary extinguishing agent because.
Technical Review Needed Fire Flow Analysis Developer Services Summit November 16, 2010 Engineering - Asset Planning Joe Dugandzic, PE.
FIREFIGHTER II LESSON 12. TYPES OF VALVES Ball — Ball — Controls nozzle flow and pump discharge rates Gate — Gate — Controls hydrant flow Butterfly.
1 CTC 450 Review Water Quality Water Quality. 2 CTC 450 Water Distribution Systems Water Distribution Systems.
Water Distribution Systems. Distribution systems Designed to adequately satisfy water requirements for combination of: Domestic use Commercial Use Industrial.
3 Water. 3 Knowledge Objectives Describe the properties of water. Describe the three sources of water. Describe water’s role in extinguishing a fire.
CHAPTER 9 Copyright © 2007 Thomson Delmar Learning 9.1 Water Supply.
EWB-NCSU Bolivia Water Supply Project. Why Do They Need Additional Water Supplies? School Students Add to Population Rainfall – Avg. 8.5 in/yr – 0.7 in/month.
NFPA 31 Standard for the installation of Oil- Burning Equipment
Pumping Apparatus Driver/Operator
Water Supply Firefighter II.
FVCC Fire Rescue Water Supply.
15 Water Supply. 2 Objectives Describe the sources of water for a municipal water supply system. Explain the purpose of a water treatment facility. Describe.
Network Appurtenances Major operations within a water transport and distribution systems are: 1. Transmission. 2. Storage. 3. Pumping.
Firefighter III Module B Water Supply (4-19) (4-19)
ISX12 G & ISL G Cold Weather Operation 1. ISX12 G and ISL G Cold Weather Operation  Cold weather affects CEGR SI natural gas engines differently compared.
Achieving Maximum Flows The Water Triangle.... The FIRE Tetrahedron.
Components of Water Networks Eng. Mona Al-Gharbawi Eng. Ayman Al-Afifi
Friction Loss Tutorial Used in conjunction with the Friction Loss Check Sheet and any Irrigation Plan.
15 Water Supply. 15 Objectives (1 of 2) Discuss rural water supplies. Describe how portable tanks are used to supply water for firefighting. Describe.
Water supply definitions Water supply definitions Four Basic components of a water supply system Four Basic components of a water supply system Methods.
Water System Master Plan & Rate Study City of DeKalb, Illinois City Council Presentation May 16, 2015.
Apparatus Testing Sugar Land Fire Department Driver/Operator-Pumper Academy Spring 2003.
Water Shuttle Operations
Snohomish County Training Officers 2013Q3. Drafting Need for drafting operations Set up and resource considerations Shuttle operations Jet Siphon Operations.
Relay Pumping Operations Sugar Land Fire Department Driver/Operator-Pumper Academy Spring 2003.
Course Content  Layout of distribution  networks, methods of water  distribution, storage capacity of ESR, and underground service reservoir.
Fire Service Pump Operator - 03 Water.
CROSS CONNECTION CONTROL PROGRAM
Lecture (11): Water Distribution Systems
Plumbing system fundamental and design course
2013Q1.
WATER DEMAND (Chapter 24)
Essentials of Fire Fighting
State of Georgia BASIC FIRE FIGHTER TRAINING COURSE
Presentation transcript:

Essentials of Fire Fighting 6th Edition Firefighter I Chapter 14 — Water Supply

Video: Fire Hydrant Time: 1:01 Chap 14-1

Ways water supply system components are used by firefighters.

There are two types of water supply systems firefighters use. Public Private Function of local government May provide water under contract to municipality, region, or single property

The amount of water needed from a supply source considers several factors. History of consumption, estimated needs Averages, maximum daily consumption tracked Domestic needs added to flow requirements for fire protection System must be capable of supplying both Calculated based on history of consumption and estimates of anticipated needs

Piping is an important aspect of the water distribution and storage system. Determines ability of water system to deliver sufficient quantity of water at adequate pressure Often referred to as water mains Generally made of cast iron, ductile iron, asbestos cement, steel, polyvinyl chloride (PVC) plastic, or concrete Water flowing through piping creates friction that may reduce water pressure

Piping Two or more primary feeders should run from source of supply to high-risk and industrial districts of community along separate routes Secondary: Intermediate pipes that interconnect with primary feeder lines to create grid Distributors: Serve individual fire hydrants and commercial and residential consumers

Storage tanks are also another component in the system. May be located throughout system to create pressure through gravity and ensure constant pressure Usually constructed of steel or concrete Higher the tank, more elevation head pressure generated

Isolation and control valves use several methods to interrupt water flow.

Isolation valves are used to isolate sections of the water supply system. Location intended for minimum disruption Maximum spacing lengths Tested at least once a year Located on easement, below ground Usually marked Directions for use Usually indicating-type for private systems

Control valves are located between public and private systems. Typical types Water flowmeter, backflow preventer also installed

Post Indicator Valves Hollow metal post that houses valve stem; plate attached to valve stem has words OPEN and SHUT

Fire hydrant locations vary depending on the water system. Connected at specified intervals Not more than 300 feet (100 m) apart in high-value districts Every building within one block May require intermediate hydrants Located along system Building constructions Occupancy Building density Size of water main Required fire flows in area Factors impacting location, spacing

Friction loss and locations can affect volume and pressure. Friction Loss: May be caused by encrustations of minerals and sediment that accumulate over period of years.Reduces pressure& volume available from hydrants. Circulating hydrant: Receives water from more than one direction Dead-end hydrant:Hydrant that receives water from only one direction; has limited water supply

Types of fire hydrants and hydrant markings.

Fire hydrants, while a dependable water source, can fail. May result from Damaged hydrant valves and connections Broken water mains Greater demand than the system can provide Hydrants located on dead end water mains Closed isolation valves Restricted mains caused by sediment and mineral deposits Pipes or hydrants that are frozen

There are several commonalities in hydrants a firefighter may encounter. Construction materials Two components to be standard Specifications At least one large (4 or 4½ inches [100 mm or 115 mm]) outlet Two hose outlet nozzles for 2½-inch (65 mm) couplings Valve opening and water main connection requirements Male threads conform with local use NFPA® 1963 regulations Most made of cast iron Internal working parts made of bronze

Dry- and wet-barrel hydrants are designed for different climates. Usually installed in warmer climates where prolonged periods of subfreezing weather are uncommon Designed for use in climates that have freezing temps

Pop quiz: Is this a dry hydrant or submarine gone aground?

Fire hydrant markings can be used to designate flow capacity.

Fire hydrant operation and inspection considerations.

Hydrant operation and inspection requires specific knowledge. Inspection frequency Wet-barrel operation Dry-barrel operation Precautions for opening, closing all hydrants

Some potential problems may be present during hydrant inspections.

Alternative water supply sources and methods of access.

Alternative water supply sources can be found in a variety of places. Private water systems Lakes, ponds, rivers, ocean Swimming pools Farm stock tanks Rainwater collection Examples Sufficient quantity Not contaminated health hazard Depth is considered Static source can be used if

Drafting operations may be required to access alternative water supplies.

VIDEO: Fire Truck Drafting Time: 0:41 Chap14- 2

Methods used for rural water supply operations.

Rural water supply operations require planning and practice. Areas lack public water distribution system System has inadequate volume, pressure Needed when

The water shuttle method transfers water to tanks for use.

There are several key components in a water shuttle operation. Dump site Fill site Mobile water supply apparatus Located near incident One or more portable tanks At water source Hauls water from fill to dump

Portable tank types require specific set up guidelines. Salvage cover or tarp As level as possible Allow easy access Several set up at once

Water supply volume is calculated on several variables. Total gallons (liters) in apparatus Round trip Fill time Travel time Dump time Gallons per minute (L/min)

Use of self-filling vacuum mobile apparatus has increased.

Establishment factors Relay pumping is used when the water source is close enough to the fire scene. Establishment factors Set up factors Other considerations Maintain volume for duration needed Must be quick enough to be worthwhile Volume of water Distance between water source, fire scene Supply hose size, amount available Pumper capacity Apparatus with greatest pumping capacity located at water source Causes of friction loss Plan in advance, practice often

VIDEO: Shuttle Relay Time: 1:02 Chap 14-3