WRI400 WIRELESS READER INTERFACE Technical Services Training for the WRI400 Launched April 2011 June 16Technical Services – Engineering Support1.

Slides:



Advertisements
Similar presentations
MHSL - Dolphin Training Class
Advertisements

RK600 / RK600e Product Training
Assembly Manual Mike Fortney 04/09/2004 CricketSat Receiver.
TagMaster Training 2013 GEN4 Software Applications
GE job title/1 GE internal information - Not for external distribution 1 GE Security EMEA NPI template – v1 1X Series (phase 1) Conventional Fire Panel.
Technical Tips. Getting Started with emPower™ Learn-in your new Z-Wave-enabled Alarm.com module following the same process as before: – Perform a Module.
22 March Controller Diagnostics. 22 March Topics Covered: Diagnostics that allows you to check basic controller and reader functionality through.
EMerge Browser Managed Security Platform Module 2 Hardware install.
DAP-1520 FAQ’s Wireless AC750 Dual Band Range Extender.
GS3055-I GSM Universal Wireless Alarm Communicator
1 Strictly confidential | Engineering| © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of.

Trouble - Shooting ELR - Electric Latch Retraction.
EVOLUTION® Hands-On Demo This guide is meant to help lead a hands-on demo or presentation. The items listed are a suggestion for things to review, please.
SAC844 Anviz Online Training Lesson 8
PXL-500/-510 Tiger Controller II
ROTHENBUHLER ENGINEERING
Medical Gas Alarm Panels
I have almost 20 years experience in the components and devices used in industrial control, instrumentation and automation applications. Before I came.
Presents The Silver Family An Integrated Approach to Processors, Data Communication and Head End Integration.
Assembly Manual Mike Fortney 04/02/2006 CricketSat Receiver.
Slide 1 / 35 P&T - GPS - Training PhB - 01_TECH_TeSys_U_controller_ en 06/2004 Presentation of the range Composition of the controller  Control base 
Training.
10 February Door Configuration. 10 February Door Configuration Allows you to define the operating parameters for each door, individually There.
 Wireless, Web-Based Monitoring System  Alarm/Event Notifications by Text Message and or  VPN Connection for Fast Response to Alarms and Events.
(Smart Loop System) Installation Guide. Rev B Shipping Box Contains Everything that is included in the box being shipped to a customer should contain.
Confidential Document 1 EverAccess Product Overview By Julian Garcia.
SF-3000 Installation Manual. 2 Back of SF CON400) USB connector - User can use USB memory stick after connect USB connector of key PCB. CON500)
TR20 Series Wireless Training Slides New Product Introduction March 2009.
INTRUSION ALARM TECHNOLOGY
ESTeem Training Class ESTeem Overview. ESTeem Product Categories Licensed Serial – Long Range Application – Exclusive Use of FCC Frequency – PLC Emulation.
1 © Red Lion Controls Inc. Introducing the RAM 9000.
System Elements HighPoint Broadband Delivery System Sector 1 Sector 3
Invision TAC™ Integrated Telephone Entry and Access Control System Product Introduction June 2010.
Nokia Bluetooth Headset BH-108 for Contact Centers
Doc. Ver. : V1.10 Feb., R&D Center Union Community Co., Ltd. Doc. Ver. : V1.10 Feb., R&D Center Union Community Co., Ltd. Installation &
1 PAC530 | Output Controller. 2 The Output Controller (PAC530) provides the local connection on an RS-485 network between an Access and Alarm Server (PAC500)
High Speed Data Converter University
4 May I/O Control. 4 May What is I/O Control? A Doors feature that allows you to program input events to drive output responses – for example:
Setting up the Ricoh C305 Press F5 to start the Presentation
System Overview The Perfect Solution For Small ‘Entry Level’ Access Control Applications August 2014.
1 Security Systems ST-CO/GP | 11/21/2006 | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights.
The PAX Lite: PAX quality at a great low price.. PAX Lite Series Indication and Setpoint Control Simple field set-up Perfect the low-cost meter users.
BOOT MODE 1 BOOT MODE 2 BIOS COMMUNICATION DEFAULT CONTROLLER INVERT RELAY OPERATION ENABLE COMM FAIL RELAY CONTROL RELAY OFF / ON COMM.
GS3055-I GSM Universal Wireless Alarm Communicator
1 Security Systems ST-CO/GP | 11/21/2006 | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights.
Trey Herrington Electrical Engineer - Backup Power Supply - Backup Power Supply - PCB Design - PCB Design Samantha Prine Electrical Engineer -Enclosure.
Trey Herrington Electrical Engineer - Backup Power Supply - Backup Power Supply - PCB Design - PCB Design Samantha Prine Electrical Engineer -Enclosure.
Technical Introduction April Internal usage only 1 General Features  Self contained batch solution for small, standalone applications.  All functionality.
Hybrid Power Controller (HPC) Mid-Semester Presentation Senior Design II.
Ethernet I/O Set-Up This presentation will step through a typical configuration of the DVT CON-IOE. Intellect 1.0 is used for the software portion.
Confidential Document 1 EverAccess Product Overview By Rodney Guinto.
PIM Technical Training, December 2011 Brian Whitcomb 12/20/2011 Call-in Number = Pass code =
Door Controller Device. 2 Door Controller Device (DCD) The DCD is the “Remote Brains” of the system. It is the controller device located at each access.
R6 Marketing Guide Keypad and Proximity Access Controller Metal Shell, IP65&Vandal Resistant.
Hearty Welcome!.
Brooks Expert Support Tool (BEST) Software
Site Controller Unit and Trunk Interface Unit
IBM PC Controlled Keypunch4b
2N® Access Unit Bluetooth
2N® Access Unit Touch Keypad
Connections Topology of Apollo ACS.
GROUND-FAULT GROUND-CHECK MONITOR
FEEDER PROTECTION UNIT
2N® Access Unit Touch Keypad
Product Training Module
Model Output Current Battery Life BATPSU VDC 2A 1.2Ah BATPSU VDC 2.3Ah
TR20 Series Wireless Training Slides
Presentation transcript:

WRI400 WIRELESS READER INTERFACE Technical Services Training for the WRI400 Launched April 2011 June 16Technical Services – Engineering Support1

Training Overview WRI400 Description Information Installation Comparison to Legacy WRI SUS/HHD “Ah-Ha’s”

WRI400 installed in Systems; AD Series Wireless Technology and access features to openings June 16Technical Services – Engineering Support3 Door Opening Gate Elevators

WRI400 Description The Schlage WRI400 is an ON-LINE wireless interface module with AD- Series technology The WRI400 can configure any opening with equivalent AD400 features Using industry portal devices; credential readers, strikes, DPS, RTX and RTE switches The WRI400 Wirelessly Interfaces readers and access control devices to a PIM400 Link and assign the WRI400 like a AD400 for AD-Series features Assign as a Legacy (PIM-485 and WRI) for Legacy features (See later page) The WRI400 is for major Openings, decorative Openings, dual door Openings, Openings using magnetic-lock, electric strikes The WRI400 will also be in an Elevator and Gate “Access” kit, see user manual The SUS/HHD connects with the WRI400 USB for firmware updates, to view or edit “Lock Properties” like an AD400 The WRI400 uses the same main Printed Circuit board and enclosure as the CT5000. They can be re-classed with Firmware (Remember the LID Label) June 16Technical Services – Engineering Support4

WRI400 Description The WRI400 can be used with up to two (2) credential readers that have Wiegand or Clock and Data outputs (wave58171) Left-side/right-side readers, ADA reader and mullion reader, Gates, and Elevators NOTE ; Both readers are the same Opening, they have the same identical access rights WRI400 Supports three optional status inputs :, Request to Enter (RTE) Request to Exit (RTX) Door Position Switch (DSP) Reader 1 Tamper and Reader 2 Tamper are reported by the WRI400; but not indentified by Access Control Panels yet - Will call Tamper1/2 “Lock Clutch Engaged” or “Dead bolt” or “Latch bolt Engaged” Supports TWO (2) Form C, dry contact relays outputs, Strike - Electric Strike, magnetic lock, Auxiliary – ADA door opener (Automatic operator) CONTROLED BY ACCESS CONTROL PANEL

The Alarm relay Is not used by the WRI400 firmware The WRI400 has no “Buzz-in” reporting feature – Buzz-in switches can be wired across the STRIKE relay output The WRI400 is a powered device and must have +12 or +24 volt power, – No AA battery operation for the WRI400, relay control requires more power than batteries – No coin cell is needed or used by the WRI400, (Like the AD400) wave58154 Coin Cell batteries are not shipped in the WRI400 The PCB silk screen says “COIN CELL NOT NEEDED IF RADIO BOARD PRESENT” The WRI400 needs a UL294 Listed Class 2 power supply, not included. (example: Schlage models PS902, PS904, and PS906) Note: The WRI400 will not power the readers wave57830 When sharing the power supply you must get the polarities correct, and select a supply which is compatible with the reader and the WRI400. The WRI400 requires 12volt 500ma; and READERS are typically 12VDC to 5VDC 200 ma each WRI400 Description

Assigning BrightBlue Templates BrightBlue will be updated late this fall to include WRI400 assignment templates. Below Work Around With BrightBlue as it is now; AD-Series, Assign the WRI400 as an AD400 Request to Enter (RTE) Request to Exit (RTX) Door Position Switch (DSP) NO AUX function, (NO ALRAM function) Assign as a Legacy, Assign a PIM400 using a BB Legacy Template WRI400 as a Legacy WRI This PIM400 can now only link to a device on a Legacy Template, it can not be shared with AD400 locks) LINK the PIM400 and the WRI400 and they now report like a Legacy WRI with AUX operations

WRI400 in a System 8June 16Technical Services – Engineering Support

WRI400 User Interface Green LEDs RED Buttons Brown Relay Status LEDs Blue Jumper June 16Technical Services – Engineering Support9

WRI400 Information User guides - P Data Sheets Technical Bulletins Firmware down loads Knowledge Center for technical questions RADAR Reporting Siebel SR reports with actions into Test Track Pro June 16Technical Services – Engineering Support10

Agency UL ratings Suitable for outdoor use, ambient temperature range -35C to +66C (-31F to +151F) and weather tight NEMA enclosure when using a NEMA gland The WRI400 is listed under UL294 as an access control system subassembly UL listed panic hardware must be used to allow emergency exit from the protected area The WRI400 has not been evaluated to UL325 or UL508, UL325/508 are automation standards UL 325 is a safety standard for door, drapery, gate, louver, and window operators and systems. Specifically, it applies to electric operators for doors, draperies, gates, louvers, windows and other opening and closing appliances rated 600 volts or less. UL 508 is a standard for Industrial Control Equipment. 11June 16Technical Services – Engineering Support

PIM400 and WRI400 Installation Location WRI400 mounting location is similar to the AD Series for RF communication to the PIM400 Secured side of the access portal The maximum RF distance indoors between a PIM400 and a WRI400 is 200 feet (61 meters) Same floor in a building normal construction materials The maximum distance for a line-of-sight installation is 1000 feet (305 meters) 12June 16Technical Services – Engineering Support

PIM400 and WRI400 Installation Location WRI400 can use the ANT400 antenna kits for increased RF communication range Use of high-gain antenna (ANT400-REM I/O +6DB) will improve range The antenna KIT includes a 15 foot cable (4.5 meters) Don’t exceed this cable length Do not locate the WRI400 and remote antenna, or the PIM400 (and its remote antenna, if used) on separate floors within a building (However having both antennas on the same floor is OK) Mounting a WRI400 is just like a PIM400 Vertically with the radio board at the top of the enclosure If on a metallic surface, stand the WRI400 off 1 inch (25 mm) from the metal 13

WRI400 Installation Wiring Portal Inputs; Status Monitors RTE, RTX, and DPS expect dry contact inputs switched to Ground when the switch is closed and the signal is ACTIVE Reader 1 Tamper and Reader 2 Tamper expect dry contact switches tied to Ground when the switch is closed, OR a signal level input for 5V logic Don’t exceed 5V – it will cause damage Connect the shield of the portal input cables to the appropriate WRI400 GND terminal – see User Guide To ensure proper integration with the ACP, the input logic may be changed from the default condition using the Schlage Utility Software (SUS) on the HHD 14

Credential Readers Inputs READER inputs; Auto-Detect Wiegand (D1/D0) Magnetic (Clock and Data) -Two separate credential reader interface headers, J17 & J18 -Reader input ports are designed for 5V logic (Typical) - Don’t exceed 5VDC -The most extensive testing was with; -Essex Electronics model KTP-162 (Keypad) -Schlage SMR-5 & SMR-20 -Mercury Security MR-5 & MR-20 (Mag Stripe) - Schlage SXF-1050 & SXF-150 (Prox) - SXF-1100, SXF-1500, SXF-2100, SXF-2110 (Multi-Tech) 15June 16Technical Services – Engineering Support

WRI400 control of the READER - Beeper, Green LED, RED LED ! The WRI400 does not provide power to the readers ! The WRI400 will use the reader beeper with a FDR. -Please consult with the reader’s manufacturer for reader configuration, readers typically beep with a card present. - Reader beeper and LED controls are configured by the reader factory per order. Configuration can sometimes be changed in the field using a "Configuration Card" from the reader manufacturer -Example: If the reader is ordered with RED LED always ON (Indicating power at the READER), the WRI400 can not turn the RED LED off

Portal Outputs, to the Door Strike & AUX Outputs are Form C relays; C, NO, NC Transient suppression per the Load Ratings are in the User Guide, Strike - 24VDC, 240vac AUX – 24VDC, 120vac 17June 16Technical Services – Engineering Support

RF PCB; The WRI400 uses the same COM400 board as the PIM400 - It has a MCX/SMB jack for the optional antenna kit The MCX Jack is the only difference between the AD400 to WRI400/PIM400 COM400 - COM400 FW 2.2a and 2.2d are compatible everywhere 18

LEGACY PRODUCTS WRI400 AD SERIES Reader Interface Times Two Two Readers, same Door fileTwo Readers same door file Two readers Wired in ParallelTwo Reader Connectors J17 & J18 CLK/D1 DATA/D0 12VDC+n/a Reader powered separately GND GRN_LED RED_LED n/aBEEPER READER_TAMPER (Two) READER_TAMPER (subject to ACP interpretation) 19June 16Technical Services – Engineering Support

LEGACY PRODUCTS WRI400 AD SERIES 20June 16Technical Services – Engineering Support CREDENTIALS PIN only ONLY with “Card Emulation” using a 26-bit keypad (Special order READER Configuration) Credential + PIN ONLY if the keypad is 8-bit format (typical READER/Keypad) Prox/Mag Cards Prox/Mag Cards (AD Series) Smart Cards not supported Smart Cards (AD Series) Power, Supply must be UL 294 Listed 12 ma + READER Legacy WRI has a reader power jack 12 or 24 Volt ma No coin cell battery is needed/used No READER Power output - If using a 24 volt power supply, D o not over voltage the reader. Check the reader voltage requirements

LEGACY PRODUCTS WRI400 AD SERIES Legacy PIMPIM400 - AD-Series (TD2 & 485) 200' Horizontally through walls200’ Horizontally through walls 1000' line-of-sight ANT-REMANT 400 (Ceiling, HALL & I/O+6dB) Gate Gate Kit - GCK400 (WRI400 Out Door, PIM400- TD2, PIM Power Supply, and ANT400-REM-I/O) Mid-June 2011 ordering Elevator Elevator Kit - ECK400 (WRI400, PIM400-TD2, PIM Power Supply, and ANT400-REM-Ceiling) Mid-June 2011 ordering June 16Technical Services – Engineering Support21

Legacy WRI and WRI400 Wire Same Type, part number, Same Maximum Lengths (User Guide) June 16Technical Services – Engineering Support22

LEGACY PRODUCTS WRI400 AD SERIES Specifications FCC Part 15, Class B, FCC Part 15, Class B UL F to +151 F Plastic Enclosure Plastic Enclosure, and larger than a WRI Legacy Outdoor option Weather Tight 23June 16Technical Services – Engineering Support

WRI400 Set-Up HHD Connection – Automatic - HHD Diagnostics from the PIM400 for RTE, RTX, DPS and Lid Tamper (ala AD400) In the User Guide and the Lid Label HHD COUPLING - Hold the WRI400 SCHLAGE Button, hit the WRI400 LINK three times CONSTRUCTION - Hold the WRI400 SCHLAGE button and present the card to be Master Construction Credntial, use the Master Construction to enroll construction user access cards LINKING - Press the WRI400 LINK button for 3 seconds (Always do the PIM400 first) FDR - Hold the WRI400 Schlage & LINK for 3 seconds TEST - Hold the WRI400 SCHLAGE and press RESET button, after re-boot, all LED & RELAY change state and the end of the reset re-boot. 24June 16Technical Services – Engineering Support

WRI400 AD SERIES LINKING LINK to PIM /TD2 Door number assignment LINKING to a PIM400 -HHD assigns door number when LINKING to a PIM , LINK 0 or LINK 1 manually when LINKING to a PIM400-TD2 Just like an AD400 25June 16Technical Services – Engineering Support

June 16Technical Services – Engineering Support26 SUS Settings for the WRI400 SUS HHD Screens for the WRI400

June 16Technical Services – Engineering Support27

June 16Technical Services – Engineering Support28

June 16Technical Services – Engineering Support29

June 16Technical Services – Engineering Support30

SUS HHD Screens for the WRI400 from PIM400 Diagnostics June 16Technical Services – Engineering Support31

SUS HHD Screens for the WRI400 from PIM400 Diagnostics June 16Technical Services – Engineering Support32

SUS HHD Screens for the WRI400 from PIM400 Diagnostics June 16Technical Services – Engineering Support33

SUS HHD Screens for the WRI400 from PIM400 Diagnostics June 16Technical Services – Engineering Support34

WRI400 Lid Label, and in the User Guide LED blinks, LINK, FDR, Coupling, Construction mode and Test June 16Technical Services – Engineering Support Confidential 35

USER GUIDE June 16Technical Services – Engineering Support Confidential 36

User Guide June 16Technical Services – Engineering Support Confidential 37

WRI400 “Ah-Ha’s” Review No power is provided to the READERS (wave57830) Using Bright Blue or an OEM Access Control Panel Add the WRI400 just like the AD400 Or Add as a Legacy WRI, using a Legacy configured PIM400 SMS & BrightBlue update schedule for fall 2011 WRI400 has no integrated “BUZZ-in” feature. Just wire the “Buzz-in” switch across the WRI400 strike relay output. Might get a Forced Door WRI400 has no “ALARM” feature, alarm relay is not controlled by the WRI400 firmware. You must use the ACP to control the AUX for an alarm function. READER LED & BEEPER control are dependent on the as-ordered READER. The WRI400 can not completely control READER LED and BEEPER 100%. June 16Technical Services – Engineering Support38