Www.HidenAnalytical.com Hiden EPIC Quadrupole Mass Spectrometer for Scientific Applications.

Slides:



Advertisements
Similar presentations
FC-MS from Teledyne Isco CombiFlash ® a Name You Can Rely On.
Advertisements

11-13/10/2007 ILC BDS Kick-Off Meeting, SLAC, US 1 BDS Vacuum System Dr. Oleg B. Malyshev ASTeC Daresbury Laboratory.
Inductively Coupled Plasma Mass Spectrometry or ICP-MS
KEK (High Energy Accelerator Organization), Japan
1 International Standardization for QMS 1. Introduction: The procedure of standardization 2. What we do and do not intend with QMS standardization 3. Content.
Market introduction CellaTemp PA.  Newest interface technology  Latest high-resolution microprocessors  Newest sensors  New amplifier technology 
Chapter 20 Molecular Mass Spectrometry. Introduction... Mass spectroscopy is perhaps one of the most widely applicable of all the analytical tools available.
Atomic Mass Spectrometry
Plasma Dynamics Lab HIBP Abstract Measurements of the radial equilibrium potential profiles have been successfully obtained with a Heavy Ion Beam Probe.
Molecular Mass Spectroscopy Chem Introduction In Mass Spectroscopy (MS), atomic and molecular weights are generally expressed in terms of atomic.
Mass Spectrometry.
An electrostatic ion trap for Fourier transform mass spectrometry
Mass Spectroscopy Quantitative Chemical Analysis Harris, 6th Edition
Photoelectron Spectroscopy Lecture 7 – instrumental details –Photon sources –Experimental resolution and sensitivity –Electron kinetic energy and resolution.
Introduction to the Varian ICP-MS. What is a mass spectrometer? The Inductively Coupled Plasma Mass Spectrometer (ICP-MS) is a fast, precise and extremely.
6. Mass Spectrometry Adv. Inst. Techs. How does it work? a very small amount of sample is bombarded by a beam of high energy (usually electron beam) produces.
Ahmad Aqel Ifseisi Assistant Professor of Analytical Chemistry College of Science, Department of Chemistry King Saud University P.O. Box 2455 Riyadh
Types of Analyses Single Collector –Uses only one collector or detector –This is the case with a Daly or EM Advantages: –Need only one detector –Peaks.
MALDI-TOF-TOF with High Resolution Precursor Selection and Multiplexed MS-MS Poster Number ThP 618 Kevin Hayden, Stephen C. Gabeler, Mark Dahl and Marvin.
Development of a TOF Version of the Desktop MiniSIMS Design & Applications A.J. Eccles, B. Cliff, C. Jones, N. Long, P. Vohralik Millbrook Instruments.
Ion Collectors and Detectors
Nitride Materials and Devices Project
Vacuum system in the main Linacs C. Garion CERN/TE/VSC CLIC09 workshop, October.
PC4250 Secondary Ion Mass Spectrometry (SIMS). What is SIMS? SIMS is a surface analysis technique used to characterize the surface and sub-surface region.
Secondary ion mass spectrometry (SIMS)
An Inductively Coupled Plasma Etcher
SEM (SCANNING ELECTRON MICROSCOPE) Özgen Buğdaycı Elif Topçuoğlu Yavuz Duran Hacettepe University
Mass spectrometry Ions are analyzed on the basis of their m/z Chlorine has 2 isotopes, 35 Cl and 37 Cl, in the approximate ratio of 3 :1. Electrons are.
Profile Measurement of HSX Plasma Using Thomson Scattering K. Zhai, F.S.B. Anderson, J. Canik, K. Likin, K. J. Willis, D.T. Anderson, HSX Plasma Laboratory,
Mass spectrometry and the PITZ Sven Lederer Technisches Seminar
Molecular mass spectrometry Chapter 20 The study of “molecular ions” M + e -  M e -
Gerardo E. Cornejo M. Bonner Denton Scott Tilden Roger Sperline Denton Research Lab Department of Chemistry University of Arizona
Corial 200ML COSMA Software with:  Edit menu for process recipe edition,  Adjust menu for process optimizing,  Maintenance menus for complete equipment.
P. Spiller, SIS18upgrade, Peter Spiller GSI, Darmstadt Kick off Meeting - EU Construction DIRAC Phase SIS18 upgrade.
Plans for the Characterization Program at Argonne Igor Veryovkin, Alexander Zinovev and Slade Jokela.
Yiting Zhangb, Mark Denninga, Randall S. Urdahla and Mark J. Kushnerb
1 Chemical Analysis by Mass Spectrometry. 2 All chemical substances are combinations of atoms. Atoms of different elements have different masses (H =
HiCAT- a Novel Diagnostic for Mass Loss and Species Composition Analysis Goal: Provide In-situ, real time characterization of ablated/ vaporized materials.
Negative Ions in IEC Devices David R. Boris 2009 US-Japan IEC Workshop 12 th October, 2009 This work performed at The University of Wisconsin Fusion Technology.
Hiden Analytical Excellence in plasma diagnostics An Introduction to the Hiden EQP Excellence in Plasma Diagnostics An Introduction to the Hiden EQP
TPD Workstation Software TPD software for control/ analysis of experiments Multiple temperature steps. Optimised data acquisition.
Plasma diagnostics using spectroscopic techniques
MS Intro. MS requires gas-phase ions, why? MS uses magnetic and electric fields to control the path of a compound based on mass to charge ratio (m/z)
Mass spectrometry (Test) Mass spectrometry (MS) is an analytical technique that measures masses of particles and for determining the elemental composition.
Ionization energy?. Ionization energy? EI Ionization??
A new RFQ cooler: concept, simulations and status Trapped Radioactive Isotopes:  icro-laboratories for Fundamental Physics E. Traykov TRI  P project.
1 US PFC Meeting, UCLA, August 3-6, 2010 DIONISOS: Upgrading to the high temperature regime G.M. Wright, K. Woller, R. Sullivan, H. Barnard, P. Stahle,
CLARA Gun Cavity Optimisation NVEC 05/06/2014 P. Goudket G. Burt, L. Cowie, J. McKenzie, B. Militsyn.
Secondary Ion Mass Spectrometry A look at SIMS and Surface Analysis.
UK Neutrino Factory Meeting Front End Test Stand (F.E.T.S.) Engineering Status by P. Savage 22nd April 2009.
Questions/Problems on SEM microcharacterization Explain why Field Emission Gun (FEG) SEM is preferred in SEM? How is a contrast generated in an SEM? What.
El-Mul Technologies Ltd – Confidential & Proprietary El-Mul Technologies El-Mul Technologies Ltd – Confidential & Proprietary Prof. Eli Cheifetz, Chairman.
TRI  P RFQ design, simulations and tests E. Traykov TRI  P project and facility RFQ tests and design Simulations Conclusion TRI  P Group: G.P. Berg,
Hiden QIC BioStream for Fermentation off gas analysis.
Quadrupole Mass Spectrometry Concepts Mass Spectrometers for Residual Gas Analysis.
Hiden HPR-20 QIC EGA for evolved gas analysis in TGA-MS.
Hiden Compact SIMS Mass Spectrometry in solid material.
MICRO-STRIP METAL DETECTOR FOR BEAM DIAGNOSTICS PRINCIPLE OF OPERATION Passing through metal strips a beam of charged particles or synchrotron radiation.
Quantitative Gas Analysis System Hiden QGA.
Instrumentation for Accelerators Technologies for the HL-LHC
Acknowledgements Slides and animations were made by Dr. Jon Karty Mass Spectrometry Facility Indiana University, Bloomington.
Study of vacuum stability at cryogenic temperature
Mass Spectrometry Obaid M. Shaikh.
Si DRIE APPLICATION In Corial 210IL.
Software description cosma pulse
ELIC Injector Working Group High-P, high-I source issues (DC)
Mass spectrometry Detection of ionic species to determine the molecular weight of and obtain structural information on a molecule.
Molecular Mass Spectroscopy
Mass spectrometry (MS) is an analytical technique that can be used to determine the mass, elemental composition or chemical structure of molecules. Mass.
Presentation transcript:

Hiden EPIC Quadrupole Mass Spectrometer for Scientific Applications

Quadrupole Mass Spectrometers for Advanced Science EPIC Applications UHV surface science Electron stimulated desorption Photon stimulated desorption Thermal desorption studies Radical analysis Clusters Time resolved studies The Hiden EPIC can be used for applications beyond the standard RGA including:

Quadrupole Mass Spectrometers for Advanced Science The EPIC advantage Pole bias mid-axis potential Negative ion capability Factory upgradable for inclusion of an energy filter ensuring compatibility with the Hiden plasma/SIMS systems Suitable for Electron Attachment Mass Spectrometry

Quadrupole Mass Spectrometers for Advanced Science Why have a triple filter? Two main advantages: 1.Strict control over the quadrupole entrance and exit fields provides enhanced sensitivity for high mass transmission and increased abundance sensitivity 2.Enhanced long-term stability. The bulk of the deselected ions from the quadrupole ioniser deposit harmlessly on the RF-only pre-filter stage, minimising contamination on the mass selective primary filter. Available configured with 6mm or 9mm pole diameter. Triple Filter Mass Spectrometer

Quadrupole Mass Spectrometers for Advanced Science Configuration Multiple ion source options Configured with 6mm or 9mm What pole diameter do I need? Total RF output power is fixed for a given generator Power demand increases dramatically with increasing RF frequency: ( ∝ ν 5 ) For given mass, performance improves with increasing frequency For given tolerances, transmission and mass separation improve with increasing pole diameter Overall size and cost increase with increasing pole diameter Enlarging pole diameter increases assembly capacitance and limits RF range (increases power losses) It is cost effective to keep the pole size to a minimum. 50/300/510 amu 50/300/510/1000/2500 amu 6mm 9mm

Quadrupole Mass Spectrometers for Advanced Science EPIC system – 6mm pole diameter Shown with stainless steel shroud Mass range options: 50, 300 or 510 AMU

Quadrupole Mass Spectrometers for Advanced Science EPIC System 9mm pole diameter with flange adapter for mounting on a DN-63-CF 114mm diameter, 4.5 “ conflat flange. Mass range options: 50, 300, 510, 1000 or 2500 AMU

Quadrupole Mass Spectrometers for Advanced Science Electron Impact (EI) - Ion Source UHV Low Profile EI source – Included as standard for EPIC systems. Twin filaments – Yttria coated iridium. Ion Source parameters are : settable, scan able, controllable over a wide range: Emission :1µA to 2 mA Electron energy:0.1eV to 150 eV Ion energy: 0 eV to 10 eV Probe axis potential: -100 eV to +100 eV eV to eV option Optimised for UHV TPD studies enabling closer proximity of the ion source to the evolution surface

Quadrupole Mass Spectrometers for Advanced Science Ion Source Options Basic Cross Beam – Used for analysis on molecular beams, where the beam may be liable to condense to condense on ioniser surfaces. The source features an unobstructed pathway through the ionising region of the source. External shrouds are available to protect the quadrupole mass filter from the condensing species Laser Cross Beam – Includes 2 orthogonal unobstructed pathways for laser photon ionisation within the source cage region, providing an alternative to electron impact and electron attachment ionisation

Quadrupole Mass Spectrometers for Advanced Science Ion Source Options 4 Lens Ion Optics with Integral Ioniser – Additionally enables analysis of low energy positive and negative ions generated externally to the analyser. For electron, photon and laser stimulated desorption studies. Included as standard in Hiden IDP systems. Platinum Ion Source – Configured for improved operation in reactive glasses. Radially symmetric, UHV compatible. Gold Plated Ion Source – Configured to minimise the effects of source outgassing. Radially symmetric, UHV compatible. Available as standard or low profile options.

Quadrupole Mass Spectrometers for Advanced Science UHV compatible mass filter shrouds EPIC 300 and quartz shroud Range of Shrouds Quartz shroud for UHV-TPD

Quadrupole Mass Spectrometers for Advanced Science EPIC – Detector Secondary Electron Multiplier SEM detector for positive and negative ions Secondary Electron Multiplier detector for positive and negative ions Fast pulse ion counting detector with continuous 7 decade measurement from 1 cs -1 to 10 7 cs -1 Analog detection mode with Faraday cup detector option extends dynamic range to > 10 decades Minimum detectable partial pressure: 5 x mbar 1 cs -1 ~ 1.3X mbar Pulse ion counting detection provides for fast data acquisition over a wide dynamic range. Ideal for fast event studies at UHV. UHV-TPD for example.

Quadrupole Mass Spectrometers for Advanced Science EPIC – performance at UHV Data from: EPIC 1000 series- 300 AMU mass spectrometer

Quadrupole Mass Spectrometers for Advanced Science Stability Measurements “Over two years the position of the flat peak measurement did not move significantly” High stability for precision isotope ratio measurement: 40 Ar/ 39 Ar geochronology research. Data taken by B Schneider et al. [1]

Quadrupole Mass Spectrometers for Advanced Science Application Specific Performance Data - 3F analyser 6mm pole diameter

Quadrupole Mass Spectrometers for Advanced Science Precise Analytical Capability

Quadrupole Mass Spectrometers for Advanced Science Precise Analytical Capability Instrument performance examples – application tailored for optimised performance 3F analyser - 6mm pole EPIC mm pole

Quadrupole Mass Spectrometers for Advanced Science EGAsoft – PC software application EGAsoft – Collect MS data and temperature in the same program. Includes special features for thermal analysis applications, temperature programmed desorption and evolved gas analysis for example. 3D bar data view in EGAsoft MS response vs. temperature

Quadrupole Mass Spectrometers for Advanced Science MASsoft Professional control software Template driven quick start operation Real time data display Mixed mode scanning including trend analysis Statistical analysis and peak integration Integrated mass spectral library

Quadrupole Mass Spectrometers for Advanced Science Summary High performance RGA with additional pole bias mid-axis potential and negative ion capability Designed and manufactured by Hiden in the UK, completely factory-upgradable and compatible with the Hiden plasma/SIMS series Suitable for vacuum fingerprint analysis, leak detection and trend analysis plus UHV surface studies

Quadrupole Mass Spectrometers for Advanced Science Hiden Customers include: Samsung NASA Intel Corporation, USA CERN Carl Zeiss, Germany California Institute of Technology Brookhaven National Laboratory Corning CCFE (JET) Durham University National Physical Laboratory Jozef Stephan Institut Max Planck Institut Bern University Rutherford Appleton Laboratory SLAC National Accelerator Laboratory University of Sao Paulo Los Alamos National Lab

Quadrupole Mass Spectrometers for Advanced Science Hiden Analytical Ltd. 420 Europa Boulevard Warrington, WA5 7UN, England Tel: +44 (0)