Www.HidenAnalytical.com Quadrupole Mass Spectrometry Concepts Mass Spectrometers for Residual Gas Analysis.

Slides:



Advertisements
Similar presentations
A guide for GCSE students KNOCKHARDY PUBLISHING
Advertisements

Measurement of Gas Concentrations by Mass Spectrometers Günter Peter, N. Müller, W. Neff, Bled April 2012 Quadrupole Mass Spectrometers are gas-specific.
FTIR ● Quite often EDS analysis will give only C and O peaks meaning that the material is organic. ● FTIR is sensitive to vibrations between bonds in materials.
Chem. 133 – 2/12 Lecture. Announcements Lab Work –Supposed to Cover Set 2 Labs – but I probably won’t cover all and then will give an extra day for period.
FC-MS from Teledyne Isco CombiFlash ® a Name You Can Rely On.
Advanced Higher Unit 3 Mass Spectrometry. Mass spectrometry can be used to determine the accurate molecular mass and structural features of an organic.
Atomic Mass Spectrometry Yongsik Lee Introduction ► Atomic mass spectrometry  Versatile and widely used tool  All elements can be determined ►
Mass spectroscopy. In a typical MS procedure:  1- a sample is loaded onto the MS instrument, and undergoes vaporization.  2- the components of the sample.
12-1 Molecular Mass Spectroscopy Molecular structure Composition of mixtures Molecular mass spectra Ion Source Mass Spectrometers Applications.
Mass Spectrometry The substance being analyzed (solid or liquid) is injected into the mass spectrometer and vaporized at elevated temperature and reduced.
17.1 Mass Spectrometry Learning Objectives:
Mass Spectroscopy Mass Spectrometry ä Most useful tool for molecular structure determination if you can get it into gas phase ä Molecular weight of.
Chapter 20 Molecular Mass Spectrometry. Introduction... Mass spectroscopy is perhaps one of the most widely applicable of all the analytical tools available.
Atomic Mass Spectrometry
Mass Spectrometry.
Molecular Mass Spectrometry
Mass Spectroscopy Quantitative Chemical Analysis Harris, 6th Edition
Mass Spectroscopy 1Dr. Nikhat Siddiqi. Mass spectrometry is a powerful analytical technique that is used to identify unknown compounds, to quantify known.
6. Mass Spectrometry Adv. Inst. Techs. How does it work? a very small amount of sample is bombarded by a beam of high energy (usually electron beam) produces.
Mass Spectrometer Mass spectrometere is a very powerful method to analyse the structure of organic compounds.
Mass Spectrometry.
Chapter 8 – Mass Spectrometry. Mass Spectrometry The mass spectrometer can be used for: – Quantitative analysis – as a sophisticated and very sensitive.
GCMS: gas chromatography and mass spectrometry
Mass spectrometry Ions are analyzed on the basis of their m/z Chlorine has 2 isotopes, 35 Cl and 37 Cl, in the approximate ratio of 3 :1. Electrons are.
Understanding mass spectroscopy. Mass spectroscopy is a very powerful analytical tool that can provide information on the molecular mass of a compound,
Mass spectrometry and the PITZ Sven Lederer Technisches Seminar
Molecular mass spectrometry Chapter 20 The study of “molecular ions” M + e -  M e -
1 Chemical Analysis by Mass Spectrometry. 2 All chemical substances are combinations of atoms. Atoms of different elements have different masses (H =
Hiden Analytical Excellence in plasma diagnostics An Introduction to the Hiden EQP Excellence in Plasma Diagnostics An Introduction to the Hiden EQP
Mass Spectroscopy 1 Mass Spectroscopy (Mass Spec) Applying Atomic Structure Knowledge to Chemical Analysis.
Mass Spectroscopy Mass spectroscopy is a powerful tool in organic chemistry that can be used to provide information about the molecular formula and structural.
CH 908: Mass Spectrometry Lecture 4 Interpreting Electron Impact Mass Spectra – Continued… Recommended: Read chapters 8-9 of McLafferty Prof. Peter B.
Atomic Structure HL and SL 2.1 The Atom Atoms were thought to be uniform spheres like snooker balls. Experiments, however, have shown that atoms consist.
MS Intro. MS requires gas-phase ions, why? MS uses magnetic and electric fields to control the path of a compound based on mass to charge ratio (m/z)
Chemistry Topic: Atomic theory Subtopic : Mass Spectrometer.
Created with MindGenius Business 2005® Mass Spectrometry Mass Spectrometry.
Mass spectrometry (Test) Mass spectrometry (MS) is an analytical technique that measures masses of particles and for determining the elemental composition.
Ionization Detectors Basic operation
Combining and Choosing Analytical Techniques Chapter 8.
Starter: Spec links 1.06–1.10. Green pens out! Spec links 1.06–1.10.
MATTER 1.1ATOMS AND MOLECULES MATTER CONTENTS Define relative atomic mass and relative molecular mass based on the C-12 scale Analyze mass spectra in.
Mass spectrometry L.O.: Understand how fragmentation can be useful to find the molecular structure.
F LORIDA I NTERNATIONAL U NIVERSITY Advanced Mass Spectrometry Piero R. Gardinali/Yong Cai/ Bruce McCord Revised on August 23, 2009.
Mass Spectroscopy Introduction.
Secondary Ion Mass Spectrometry A look at SIMS and Surface Analysis.
LIQUID CHROMATOGRAPHY-MASS SPECTROMETRY
Relative Mass ysis/masspec/elements.html.
Chem. 133 – 2/11 Lecture. Announcements Lab today –Will cover 4 (of 8) set 2 labs (remainder covered on Tuesday) –Period 1 will extend one day Website/Homework.
CONTENTS Fragmentation of molecular ions - theory What a mass spectrum tells you Molecular ions Fragmentation Mass spectra of alkanes Mass spectra of halogenoalkanes.
Applications as Residual Gas Analyzer (RGA)
Hiden EPIC Quadrupole Mass Spectrometer for Scientific Applications.
Hiden HPR-20 QIC EGA for evolved gas analysis in TGA-MS.
1 Chapter 12 Mass Spectrometry ( 質譜 ) Organic Chemistry, 7 th Edition L. G. Wade, Jr. 藥學系 藥物分析科 許秀蘊 教授
Objective  To develop methods for analysis of compounds in organic aerosol particles Why is this important?  Environmental impact  Alternative fuels.
Atomic structure L.O. To be able to recall definitions of relative atomic, isotopic and molecular mass. To demonstrate an understanding of the basic.
FURTHER MASS SPECTROMETRY KNOCKHARDY PUBLISHING
Components of Mass Spectrometer
Acknowledgements Slides and animations were made by Dr. Jon Karty Mass Spectrometry Facility Indiana University, Bloomington.
Atomic structure L.O. 1. To be able to recall definitions of relative atomic, isotopic and molecular mass. 2. To learn about the key principles of mass.
Starter Complete the quiz and hand in..
Mass Spectroscopy. Mass Spectroscopy Mass Spectrometry Most useful tool for molecular structure determination if you can get it into gas phase Molecular.
Mass Spectrometer Basics and Spectra Interpretation
Lecture 22 Introduction to Mass Spectrometry Lecture Problem 7 Due
FURTHER MASS SPECTROMETRY KNOCKHARDY PUBLISHING
Mass Spectroscopy tutorial
Mass Spectrometry THE MAIN USE OF MS IN ORG CHEM IS:
FURTHER MASS SPECTROMETRY KNOCKHARDY PUBLISHING
Mass spectrometry (MS) is an analytical technique that can be used to determine the mass, elemental composition or chemical structure of molecules. Mass.
Presentation transcript:

Quadrupole Mass Spectrometry Concepts Mass Spectrometers for Residual Gas Analysis

Quadrupole Mass Spectrometers for Advanced Science Residual Gas Analysis What does Residual Gas Analysis allow us to do? RGA is the examination of the molecular components present in a vessel or evolved from a system. It allows us to analyse, ON-LINE and in REAL time: Base Pressure Fingerprint Leak Detection Virtual Leaks / desorption Outgassing / Bakeout Cycles Pump Performance Chamber contaminants Characterise your system and process for optimum results

Quadrupole Mass Spectrometers for Advanced Science Typical contaminant species present may be readily identified: Air leak: m/e 28 / 32 (ca. 4.5:1 ratio) confirm by the presence of peaks at m/e 14, 16 Water: m/e 18 confirm by m/e 17 Residual Gas Analysis

Quadrupole Mass Spectrometers for Advanced Science Typical contaminant species present may be readily identified: Hydrocarbons: characteristic groups of peaks, typical peaks at m/e 57, 55, 45, 43 High mass peaks - back-streaming of oil or Vacuum Grease Low mass peaks - Cleaning fluid / solvent residue Residual Gas Analysis

Quadrupole Mass Spectrometers for Advanced Science IONISATION – Electron Impact Ionisation (EI) Operation depends on the conversion of gas molecules into charged particles, typically positive ions / fragments. Achieved by electron impact ionisation via thermionic emission from a hot filament. A typical current is 1x10 -4 Amps. Ions extracted into the mass filter. Note: Ionisation depends on the nature of the species involved. If a species is readily ionised it produces a higher MS signal than one which is poorly ionised. Use N 2 as a standard, RELATIVE SENSIVITY = 1 c.f. Benzene = 5.9 and Helium = Residual Gas Analysis : How it works

Quadrupole Mass Spectrometers for Advanced Science IONISATION – Electron Impact Ionisation (EI) Residual Gas Analysis: How it works

Quadrupole Mass Spectrometers for Advanced Science How it works : IONISATION The choice of filament material is important: Residual Gas Analysis

Quadrupole Mass Spectrometers for Advanced Science How it works : IONISATION It is also important to note that EI yields several types of ions: See cracking pattern section for further details. Note: Fragment ions are also known as Product or Daughter Ions Residual Gas Analysis

Quadrupole Mass Spectrometers for Advanced Science How it works : THE MASS FILTER The mass filter differentiates the ions produced and selects species for detection. The most common form of mass filter is the Quadrupole. A Quadrupole is 2 pairs of parallel, equidistant metal rods (poles) biased at equal, but opposite potentials These twin potentials contain fixed DC and alternating RF components. By varying the RF component the resultant field produced by the rods may be varied. Residual Gas Analysis

Quadrupole Mass Spectrometers for Advanced Science How it works: THE MASS FILTER Any ions entering the quadrupole field experience potential differences deflecting them from their original trajectory. The extent of deflection of any ion entering the field is related to its mass : charge (m/e or m/z) ratio. At each interval on the RF scan only one m/e ratio resonates with the field allowing the ion to pass along the z-axis. All other species are deflected and neutralised by impact upon the rods of the quadrupole Residual Gas Analysis

Quadrupole Mass Spectrometers for Advanced Science How it works : THE MASS FILTER +(V dc + V rf cos  t) - (V dc + V rf cos  t) x y Residual Gas Analysis

Quadrupole Mass Spectrometers for Advanced Science How it works : THE MASS FILTER -Mathieu Stability Diagrams YZ XZ Residual Gas Analysis

Quadrupole Mass Spectrometers for Advanced Science How it works : THE DETECTOR Filtered ions strike the detector to result in an ion current which is measured by a sensitive amplifier. Two main types of Detector: a) The Faraday Cup – an earthed passive conducting surface with a suppressor electrode to avoid false measurement. Fast moving ions strike the cup cause a ‘shower’ of ‘secondary’ electrons. The use of the ‘cup’ rather than a plate, allows all electrons to be collected. Hence, one ion arriving at the Faraday needs one electron for neutralisation but causes several electrons to be emitted; this provides amplification – several electrons for each ion. Residual Gas Analysis

Quadrupole Mass Spectrometers for Advanced Science How it works : THE DETECTOR The Faraday Cup: Detection limits Ion current for N 2 is amps / Torr At Torr of N 2, * = amps At Torr of N 2 = amps  Detection limit for conventional analogue amplifier Residual Gas Analysis

Quadrupole Mass Spectrometers for Advanced Science How it works : THE DETECTOR b) Secondary Electron Multiplier / Single Channel Electron Multiplier (SEM / SCEM): A surface designed to generate secondary electrons. The ion impacts the surface generating 2 or 3 electrons each of which undergo further surface collisions generating more electrons, and so on in a cascade effect. Power for this cascade provided by an applied voltage. Gain is typically 10 3 (10 2 for a channel plate) Minimum detectable pressure Torr to Torr Residual Gas Analysis

Quadrupole Mass Spectrometers for Advanced Science Detector Pros and Cons: Faraday Cup : Lower cost Indestructible Accurate BUT : Detection limit Torr Measurement relatively slow near detection limit Residual Gas Analysis

Quadrupole Mass Spectrometers for Advanced Science SEM / SCEM : Detection limit Torr with analogue detection Faster measurement BUT : Expensive/Expendable/Sensitivity species dependent Sensitivity time / application dependent Typical maximum pressure of Torr Residual Gas Analysis

Quadrupole Mass Spectrometers for Advanced Science Resolution : The ability to separate /resolve ions of different m/e ratios All definitions directly / indirectly relate peak width to height For example: M /  M M at 10% peak height where  M <1 a.m.u. i.e. For any given mass M, the peak width at 10% of the peak height, measured from the baseline, is less than 1 amu This may be complicated if the mass peaks of trace species occur in the peak tail of a major species e.g. the detection of m/e 27 or m/e 29 in the presence of N 2 at m/e 28. Residual Gas Analysis

Quadrupole Mass Spectrometers for Advanced Science Interpretation and Cracking Patterns: RGA data can be presented as a profile of mass / charge peaks. e.g. the RGA of Air : Residual Gas Analysis

Quadrupole Mass Spectrometers for Advanced Science Cracking Patterns: Cracking arises during ionisation when the high energy electrons used not only ionise species but fragment them. For CO: 12 C 16 O + e -  ( 12 C 16 O) + Ionisation to give a peak at m/e= C 16 O + e -  12 C + 16 O + Cracking to give a peak at m/e =16 12 C 16 O+ e -  12 C OCracking to give a peak at m/e= 12 This fragmentation can be used to differentiate isobaric species: 12 C 16 O from 14 N 2 for example. 14 N 2 has peaks at m/e 28 ( 14 N 2 + ) and m/e 14 ( 14 N + ) from: 14 N 2 + e -  ( 14 N 2 ) + Ionisation to give a peak at m/e= N 2 + e -  14 N + 14 N + Cracking to give a peak at m/e =14 ( 14 N 2 ) + + e -  ( 14 N 2 ) ++ Ionisation to give a peak at m/e= 14 Note: CO/N 2 are ISOBARIC  the same mass but different composition Residual Gas Analysis

Quadrupole Mass Spectrometers for Advanced Science Interpretation and Cracking Patterns: Using Cracking Patterns it is possible to identify all species NOTE: The cracking pattern is directly related to the energy of the electrons used i.e. Under normal conditions the Cracking pattern is characteristic of a species N 2 m/e 28, 14 H 2 O m/e 18,17 O 2 m/e 32, 16 Ar m/e 40 CO 2 m/e 44, 28, 16 Residual Gas Analysis

Quadrupole Mass Spectrometers for Advanced Science Interpretation and Cracking Patterns: Cracking pattern example – Linear Hydrocarbons Decane (C 10 H 22 ) and Butane (C 4 H 10 ) show similarities – why? Both compounds show Clusters of Peaks at: m/z 57 m/z 43 m/z 29  Loss of unit of mass 14 Residual Gas Analysis

Quadrupole Mass Spectrometers for Advanced Science Interpretation and Cracking Patterns: Cracking pattern example The mass 14 unit  loss of alkyl-type species CH 2 i.e. C 10 H 22 + e -  C 10 H e -  CH 3 +, C 2 H 5 +, C 3 H 7 +, C 4 H 9 +, C 5 H 11 + etc. And C 4 H 10 + e -  C 4 H 9 + +e -  CH 3 +, C 2 H 5 +, C 3 H 7 +  FRAGMENTATION – Bond cleavage AND Ionisation. Residual Gas Analysis

Quadrupole Mass Spectrometers for Advanced Science Interpretation: Isotopic Abundance. Many species exist as several naturally occurring isotopes : Residual Gas Analysis

Quadrupole Mass Spectrometers for Advanced Science Interpretation : Isotopic Abundance eg: Sulfur isotopes in the MS of SF 6 32 SF SF SF SF SF SF SF SF 2 + Residual Gas Analysis 34 SF SF SF SF SF SF SF 2 +

Quadrupole Mass Spectrometers for Advanced Science Interpretation: General steps in interpretation of a Mass Spectrum. 1. Look for the Molecular Ion(s) 2. Note the general appearance of the spectrum 3. Check spectrum for peak clusters for Isotope patterns 4. Check for low-mass neutral fragment loss e.g. CH 2 5. Check for characteristic low-mass fragments 6. Compare to reference spectra Residual Gas Analysis

Quadrupole Mass Spectrometers for Advanced Science Quadrupole Mass Spectrometers Hiden manufactures a wide range of MS systems, all tailored to specific customer applications. Options include: Mass Ranges of 50, 100, 200, 300, 510, 1000 and 2500 amu Ioniser options including cross-beam, gold plated and platinum Detectors: Faraday, and electron multipliers, channelplate, channeltron, analogue current measurement and digital pulse ion counting options. 6mm, 9 mm or 12mm pole diameter Single and triple filter options Ethernet, USB, and serial comms.

Quadrupole Mass Spectrometers for Advanced Science Hiden Gas Analysers Rugged modular construction with precision machined radial ceramic rod supports Powerful processor with data buffering for true multi-tasking operation Ion blast free for maximum sensitivity in He leak detection Detection to 5x Torr / PPB levels Bench, cart or console mounted Fully automated operation Application specific gas inlets Corrosive gas / oil free pumping Multi-stream options Quantitative gas analysis

Quadrupole Mass Spectrometers for Advanced Science Appendix 1 Table 1a gives some of the common RGA contaminants.

Quadrupole Mass Spectrometers for Advanced Science Appendix 2 Table 1b gives more common RGA contaminants.