Zones 1 to 8 Siren Keypad Power 12V Data and clock By default: Zone 1 Entry Exit 2 Follower 3 Instant 4 Instant 5 Instant 6 Instant 7 Instant 8 Panic.

Slides:



Advertisements
Similar presentations
Prescient II Extinguishing Control Panels
Advertisements

GCC BUILDING SECURITY PROCEDURE STAFF TRAINING. Why is security so important? Burglary Burglary Vandals Vandals Loss of facility Loss of facility Cost.
INTRUSION ALARM TECHNOLOGY
Concord 4 Security System Advanced Training.
SCW9057 Key Features/Benefits
Welcome to the Radionet Monitoring Secure-Com Presentation.
Introducing The IP550 IP Telephone. Things you should know about an IP Telephone system The IPitomy system has many of the same features of traditional.
Burglar & Fire Alarm Basics
ANSI SIA CP-01 CONTROL PANEL STANDARDS
GS3055-I Installation Process
AIM Armstrong’s Intelligent Monitoring Training presentation.
GE job title/1 GE internal information - Not for external distribution 1 GE Security EMEA NPI template – v1 1X Series (phase 1) Conventional Fire Panel.
Motorcycle product sheets
TLA. Replacing The Battery On the Back of the pager press in this button while moving the door away from the pager, then lift up. On the Back of the pager.
WELCOME A Security Masterpiece. Control Panel Line-up Max Zones Basic Zones Max Zones Basic Zones n 1725EX14 6 (4 + 2) n 1728EX15 7 (5 + 2) n 1738EX16.
Meridian M2008 & 2616 Please press the F5 key on your PC to begin the presentation Press the space bar or arrow keys to advance 1 IT Support Center
ESI Phone System Training Adcom/Valentine Systems
GS3055-I GSM Universal Wireless Alarm Communicator
System Capacity MAP 5000 Release 1.2 Feature Overview
May 2007 North Zone – Communications Motorola W9 Control Head North Zone Communications Committee.
ROTHENBUHLER ENGINEERING
Motorcycle antitheft systems Spyball 6500 platform Benefits 6500 Description: compact motorcycle antitheft alarm and engine immobiliser. Arming/disarming.
MySOS User Guide.
Yuma Regional Communications System
The Comfort System Product Presentation The Intelligent Home System.
Reverb in Siren. What is Reverb? Reverberation is the persistence of sound in a particular space after the original sound is removed. A reverberation,
Confidential Document 1 EverAccess Product Overview By Julian Garcia.
Cisco VoIP Wireless Telephone 7921G Model Please press the F5 key on your PC to begin the presentation Click to advance IT Support Center or
1. 2 LXU800 User’s Manual 1.Installation – Windows XP UI Features Introduction Data Connection & Disconnection.
1 INTRUSION ALARM TECHNOLOGY KEYPADS (CONTROL UNITS)
Lynx Series Lynx Plus LynxR-2 LynxR-EN LynxR-i LynxR-iSIA
An Introduction to the Windows-based PC Programming Tool Version 0.91
ClearPath Hosted MVP Web Portal 1. Log In Page Users are able to access the Web Portal by using their assigned user name and password. Access Web Browser.
Burglar & Fire Alarm Basics
Chapter 2 What is an Alarm System? Alarms: The First Line of Defense
The Comfort System Product Presentation The Intelligent Home System Revised May 2009.
AVS Audio Verification System
The 4205 Set has ten fixed-function keys (SUPERKEY, TRANS/CONF, REDIAL, MESSAGE, HOLD, CANCEL, SPEAKER, MICROPHONE, arrow up, and down) and 14 personal.
TL250-Internet Communicator. Compatibility Specifications VDC current draw 12 VDC input voltage Size: 3.25” × 5.25” (8.3 × 13.3)cm Operating.
Power Series Basic Programming NTS# Agenda DSC PowerSeries Basic Programming Course Length 4 hrs Course Overview(5 Min).At the conclusion of.
4 May I/O Control. 4 May What is I/O Control? A Doors feature that allows you to program input events to drive output responses – for example:
Your New Cisco Phone.
An Introduction to the R3 19 inch Rack The R3 control system comprises a number of different plug in modules, each of which is dedicated to a particular.
Gauge Operation and Software by Scott A. Ager. Computer Recommendations 750 MHz Pentium III 64 Meg SRAM 40 Gig Hard Drive 1024 x 768 graphics CD Writer.
2 If you can install a Vista panel... you can install VistaKey!
BOOT MODE 1 BOOT MODE 2 BIOS COMMUNICATION DEFAULT CONTROLLER INVERT RELAY OPERATION ENABLE COMM FAIL RELAY CONTROL RELAY OFF / ON COMM.
GS3055-I GSM Universal Wireless Alarm Communicator
Introducing The IP550 IP Telephone. What to expect from your new IPitomy IP telephone system The IPitomy system has many of the same features of traditional.
1 THE VICTOR READER WAVE ● Plays DAISY books as well as music and books on MP3 or audio CD ● Powerful navigation features ● Go directly to any page number.
GS3055-I Installation Process
The Monitor 4000 Alarm provides the most cost effective, worry-free method of keeping backdoors secure during business hours…protecting your business,
2 December, 2015 New Conventional Fire Control Panel.
Features and Specs 512 Channels 32 Groups of 16 Channels High/Low Power 5 Watts High 2 Watts Low Multi-line Alphanumeric Display 3 year warranty.
Service Section Technical Training December 2005.
Spring Hill Assembly1 InnoSys Park Brake Tool Master Control Panel Screens 1 3-Mar-2008.
Puissant Panel User Training Esc.. 09:11:35 ACTIVE # * 3 6 RESET SYSTEM CLEAR DISPLAY TEST DISPLAY SILENCE BUZZER ESCAPE ENTER SILENCE.
All Freezer Advance. When the Freezer is first supplied with power or if a power outage occurs, the display will indicate this by flashing the temperature.
S3b Sim Secual Product Training March Connected to your smartphone Communication by SIM card Interact with your system everywhere you are Control.
R6 Marketing Guide Keypad and Proximity Access Controller Metal Shell, IP65&Vandal Resistant.
EGIS Man-Down - Quick User Guide Version
Advisor Advanced Release FW120.
GEM-P1632 Hybrid Control Communicator
with UCM/KNX Rev Sept 2010 Ref: UCM/KNX Manual
Slides include notes (more details about every slide information).
ADEMCO GROUP.
AIM Armstrong’s Intelligent Monitoring Training presentation.
Reliable Fixed-Zone Systems
Welcome to the Programming Seminar.
Main Unit Establishment
System 57 Gas Control System
Presentation transcript:

Zones 1 to 8 Siren Keypad Power 12V Data and clock By default: Zone 1 Entry Exit 2 Follower 3 Instant 4 Instant 5 Instant 6 Instant 7 Instant 8 Panic Outputs1 to 5 By default: Output 1 Panic 2 Burglary 3 Open Closed Removable dialler 16 Volts AC Aux. Power Positve12V

Star Key Enter key for Data Input Hash Key Cancel, Backspace or Exit key

Ready LED Will flash when in programming mode Away LED Indicates if a location has been entered and a value can be programmed

How to read the values in a location Value Each zone indicator is given a value

How to read the values in a location Example: Value in the location is 5 Each zone indicator is given a value To get the value in that location add the zone values together of any zones that are on

Press the # key to clear any previous key presses The default installer code is 9999 The ready LED will begin to flash indicating that programming mode has been entered How to enter into programming mode

All data that is entered must be entered into location A location is a storage area in the alarm panel’s memory. Each location or memory area is linked to a specific task. What is a location? Example: Location 15 is linked to making the alarm silent Location 18 is linked to the exit delay period during the arm cycle

You must be in programming mode To enter a value: 1. Enter the location to be programmed (The away light will come on to show that you are in the location) 2. Once in the location enter the value of the data and confirm by pressing the * key Once the data has been entered you are removed from the location Entering a location to programme a value

Location 0 ValueAction 0 Resets all locations to the factory default values. 1 Defaults the master user code to Resets all reporting codes to 0 Defaulting

Location 1 to 8 Zone Characteristics ValueType 0 Disable 1 Entry / Exit 2 Follower 3Audible priority / Panic 4Audible Instant 5Arm / Disarm 6Silent Priority 7Silent Instant 8Secondary Entry / Exit 10Fire Zone 12Push to Arm

LocationDescriptionDefault Value 9Entry / exit options Entry/ exit zones must be clear | Follower zones must be clear | Entry/ exit delay enabled 9 (Entry / exit zones clear, delay enabled) 10Secondary Entry exit delay5 (1min) 11Tamper per zone0 (Disable) 12Arming options Quick Arm | Entry/ exit delay with arm zone | Forced arming | Engineer reset 1(Quick Arm) 13Stay Arm Options Entry exit not violated | Always away arm no 5 key | Always away arm with 5 key 0 (Entry exit not violated) 14Silent Keypad Panic Options0 (Audible) 15Silent Alarm Options0 (Audible) 16Siren Toot on Arm & Disarm0 (no toot) 17Siren Time Out Period6 (2min) 18Exit Delay Period3 (30sec) 19AC Fail & Restore Time1 (2min) 20Primary Entry Delay3 (30sec) 21Hardware rest Switch Enable / Disable15 (Enable)

Exercise: 1.Change zone 7 to be an arm / disarm zone 2.Make the exit delay 10 seconds 3.Set siren toot on arm and disarm 4.When arming the front door must be allowed to remain open

Programmable OutputProgram Value PulseSet HighSet Low Output Output Output Output Output

LocationEventValue 22Alarm2 23, 26, 36Audible Panic, Duress, Silent Panic1 28Open8 29close13 22 to 41Output locations Zone programmable output Control Tamper output control

Exercise: 1.When the medical condition is triggered output 4 must pulse 2.Set output 5 to the strobe output

Reporting via Telephone LocationDescriptionDefault 42 Phone number and dialling options Join numbers | Pulse or Tone dialling | Single or Dual reporting 1 No join | Tone | Single Primary account code 47 Primary Communicator Format0 Secoa Superfast Primary Telephone number Secondary Telephone number 151 Dial Attempts Secondary Account code 156 Secondary Communicator Format0 Secoa Superfast 157 Communication Delay0

Note when entering telephone numbers:  0 is programmed as a 10  * Is an 11  # is a 12  12 second pause is a 14  4 second pause is a 15  Terminate the number with a 0 (zero not a ten)

Reporting Codes Location 80 to 133 Contact Id and Sescoa Superfast are the only reporting codes that are inserted when chosen as a reporting format. The rest of the reporting codes must be manually entered To disable a reporting code enter a 0 If a reporting code requires a 0 the use 10

Exercise: 1.Enter 0(4 second pause) as the telephone number 2.Account code of 1023 Reporting format is Contact ID

LocationDescriptionDefault Installer code Swinger shutdown count0 141Zone loop Response100mS 142Zone Trip count0 143Zone Trip count delay timer0 144Programmable Trouble Display Display of TLM Fail | Display of Siren Tamper 3 Display both 145Programmable Trouble Display 2 Display of Comms. Fail | Display of Keypad Tamper | Display of Eng. Reset 7 146Keypad sleep delay128 sec 147Auto test delay24 Hrs

LocationDescriptionDefault 148Number of rings before answer24 Hrs 149Keypad buzzer options Beep on communication | Beep on trouble | Beep on both Enable siren, telephone line, box tamper monitoring2 Beep on communication 800System time 801Auto-test time 802Auto Arm Time

A trouble condition is indicated by a flashing power light Press and hold the 7 key for 3 seconds ZoneTrouble Condition 2 Failure to communicate to monitoring Company 3 Mains power fail 4 Low Battery 5 Telephone line tamper or not present 6 Siren tamper 7 Keypad tamper 8 Engineer reset required

Ready LED Shows that the alarm is ready to arm Away LED Indicates that the alarm has armed in the away mode Armed LED Shows that the alarm is armed Power LED On means there is power Flashing shows that there is a trouble condition

3 Arming options Away arming In this mode the alarm is fully armed, all zones are active. The delay on the entry exit zones will be active Stay arming Zones that have been preselected will be automatically bypassed to allow people to move around without activating the alarm Stay and Go arming Zones that have been preselected will be automatically bypassed The delay on the entry exit zones will be active

2 options in how to arm in the away mode Enter a user code and when the exit beeps begin, exit through an entry / exit zone Press and hold the 1 key for 3 seconds and when the exit beeps begin exit through an entry / exit zone Note: Failure to exit via a entry / exit zone will force the panel to arm in the stay arm mode in the default configuration.

Press and hold the 5 key until armed LED is on The zones that were selected as stay zones will be bypassed and these zones will be shown on the keypad

To select zones to be bypassed in the stay mode Press and hold 3 until the buzzer sounds Then press the zone number then * Do this for all zones required When complete press #

2 Stay profiles Two different zone groupings to be bypassed can be created To change profiles Mode profile number + * Note: the second profile’s zones to be bypassed must be selected as before

The best of both away and stay arming In this mode all entry / exit zones are active and the zones selected in the Stay profile will be bypassed Note: the active stay profile is used to determine which zones to bypass

Disarming A valid user code must be entered Or A remote Transmitter and Receiver can be used

Press star then the zone number to be bypassed or un-bypassed

Alarm memory To see what zones were violated Press and hold the 0 key until the buzzer sounds Zone bypassed Memory To see which zones were bypassed Press and hold the 0 key until the buzzer sounds then press 1 Zone Tamper Memory To see what zones have been tampered with Press and hold the 0 key until the buzzer sounds then press 2 Memory is cleared when the panel is armed

15 user codes made up of the following: 12 x standard user codes (arm and disarm) 1 x Master User ( Slot 1 Administrator ) 1 x Maids Code ( Slot 14 Will only disarm if it was used to arm ) 1 x Duress ( Slot 15 Will arm or disarm and send a panic signal )

* Master code * slot number * new code * Eg. * 1234 * 4 * 5647* Deleting a user code * Master code * slot number * * Eg. * 1234 * 5**

Chime Zones The keypad will chime when a zone that has been made a chime zone is violated in the unarmed state Press and hold 2 until buzzer sounds then zone number then * Buzz Zones The keypad will buzz for 30 seconds when a zone that has been made a buzz zone is violated in the stay armed state Press and hold 4 until buzzer sounds then zone number then *

Zone Indicator Trouble Condition 2Failure to communicate to monitoring Company 3Mains power fail 4Low Battery 5Telephone line tamper or not present 6Siren tamper 7Keypad tamper 8Engineer reset required Press and hold 7 until buzzer sounds Press # within 5 seconds to clear the condition Some conditions will clear automatically when fixed