LIGHTING MANAGEMENT | PRODUCTS & SYSTEMS PUTTING A STOP TO ENERGY WASTE LIGHTING MANAGEMENT SYSTEM PUTTING A STOP TO ENERGY WASTE.

Slides:



Advertisements
Similar presentations
1 Signals, Circuits, and Computers John Athanasiou Part B Spring 2010.
Advertisements

Lighting concepts – Ballasts and Lighting Controls
Operating Functions.
Tom Johanson – DNV KEMA Senior Engineer Building Automation Systems.
How Electronic Security Solutions can Help the Government in Securing its Assets and Reduce Energy expenditure Presented By- Nimish Vishnoi Manager-Product.
Lighting and Wastewater Controls Smithfield Foods Engineering.
Lighting Automation LLC 800-LED Lighting Automation Smart Lighting Systems.
© Universal Lighting Technologies | 1 Wall-Switch Sensors Ceiling Sensors Power Packs.
I can see the light! Energy Efficient Lighting. Energy webinar series.
Applications © 2013 Sensor Switch. nLight Feature: Varying Time Delay Application: Hallway Morning: Lights automatically turn on for early arriving workers.
Chapter 7 Discrete Control Using Wireless Field Devices.
Wired lighting systems Lighting energy accounts for nearly 50% of commercial building electricity consumption and represents 11% of California peak.
BRE Energy Efficient Office of the Future
Lighting Techniques and Technology Practical Applications Britnei Godusky LC, LEED AP BD+C June 4, 2014AOBA / Current Trends in Sustainability.
Wired lighting systems Lighting energy accounts for nearly 50% of commercial building electricity consumption and represents 11% of California peak.
Providing services that help make The University of Memphis a safe and healthful place to learn and work Environmental Health and Safety.
Key Technology Overview. All PIR is not Created Equal… Sensors are fine-tuned at the factory for optimum detection for its coverage pattern – no PIR sensitivity.
Basics of Movement Presence Detection ISC Learning Centre July 2009.
Motion Sensors Occupancy Sensors Presence Sensors PIR Sensors.
SMART HOMES The way we nest now Suhasini K Vamsi Priya V Sushmitha K.
Changes to Mandatory Title 24 Lighting Requirements Bill Blackley LC Director Product Marketing California's new building energy efficient standards took.
A solution to ATM Energy and Security Management
Energy Efficiency with ABB i-bus® KNX
Leviton, your single source for energy management lighting control.
Introducing The Revolutionary ENSA  EN ergy SA ving Automated Wireless Light Switch A World First For The Security Industry By Making Alarm Sensors Dual.
Wired lighting systems Lighting energy accounts for nearly 50% of commercial building electricity consumption and represents 11% of California peak.
SENSORS Question: Question: Which technological system can help us to save energy?
Motion detector ​ Bikesh Shrestha ​ Ari Rajamäki.
An Activity to Explore Material Properties and Lighting Controls Beating the Motion Sensor.
WSK-24 Wireless Occupancy Solution New Product Introduction Customer Sales Presentation June 2009.
Daikin Australia Pty. Limited Ducted Split Systems 2011.
PIR MOTION SENSOR Created by: Zaryab Altaf S
Static Pressure Control Loop The purpose of the static pressure control loop is to maintain an optimal static pressure in the ductwork. The control loop.
Energy Performance Certificates
Melcotel TM Features and Benefits Melcotel - Introduction New features –Links with up to 250 room units –Settings reset –Automatic switch OFF –Setback.
Motion Sensor Policy Reform  Brief review of Motion Sensor Policy History  Key Regulator Requirements  Potential for conflict with Fire Code  Case.
1 Probably The Most Advanced Presence Sensors In The World. Ultra Fine MotionFine MotionHigh Frequency H.F.CorridorSmoke / FireCO2 Automatic Time delay.
Copyright 2010 – Johnson Controls, Inc. 1 A Day in the Life of a Smart Campus Clay Nesler VP, Global Energy & Sustainability Johnson Controls
Basics of Lighting Controls U.S. Department of Energy Rebuild America And Novitas, Inc.
Building Control with KNX Health - Hospital, clinic, home of the elderly.
AN INDIVIDUAL PROJECT FOCUSED ON A SMALL SCHOOL Integrating ICT Sustainability.
Building Control with KNX Education - Schools. Schneider Electric 2 - IS&C - GPatt – School’s classroom Manage according to external conditions.
1 Intelligent Lighting Solutions for Professionals.
1 INTELLIGENT HIGHTLIGHTS. THE TYCOON FAMILY OF INDIRECT LUMINAIRES.
Student Name USN NO Guide Name H.O.D Name Name Of The College & Dept.
Service Section Technical Training December 2005.
MECVEL SIGNS THE “SLIDING DOORS” REMAKE: SLIDING DOORS ONLY WITH OUR LINEAR ACTUATORS!
LIGHTING MANAGEMENT | PRODUCTS & SYSTEMS PUTTING A STOP TO ENERGY WASTE 1/22 LIGHTING MANAGEMENT OFFER PUTTING A STOP TO ENERGY WASTE.
目录 12 in 1 Sensor Features ● PIR motion sensor ● Ultrasonic sensor ● LUX sensor ● Temperature sensor ● 2 Dry contacts ● 2 external condition inputs ● IR(infrared)
Multifunctional LCD Panel HDL-MPL8.48. LCD Panel Description The HDL-MPL8.48 series is a new generation of wall mounted switch, with a total of 8 metal.
目录 8 in 1 Sensor ◆ 8 in 1 Sensor Unique Features ● Built in PIR motion sensor and light intensity sensor ● Built in 2 Dry Input Ports ● Built in 32 Logics.
Lighting and Sunblind Management Configurable Controllers - RCL-Light / Blind Series.
Building Lighting Controls
Lighting facts.  Lighting can be a big energy consumer in offices and production areas and experience shows that energy savings may be achieved - often.
Turning Off the lights Simples!!!. The Switch Person leaves the room – turn off the lights Its that simple but! So why do lights get left on? Who is responsible?
Motion Sensors By Elva S. Agbon ICS 30 B MOTION SENSORS A sensor specifically designed to detect a gentle or sharp up and down or side to side motion.
Smart Home Temperature System with Spinning LED Display Group 49: Jianxi Lu, Jia Shi, Xingchang Cheng May 4th, 2016 ECE445.
Wally Creer Director of Product Management, Systems Products
- Usable range of 0 to 6 feet. - Find dark or bright areas.
Multifunctional Sensor
DALI-Gateway DG/S 8.1.
Network Lighting Controls – How to get inside the black box
Motion Sensors By Elva S. Agbon ICS 30 B.
INTELLIGENT ENERGY SAVING SYSTEM USING PIC MICROCONTROLLER
Lighting Control Indoor Lighting
Obstacle Detection Ultrasonic Sensor.
Stand-Alone Systems / Occupancy Sensors
Light level sensor Temperature sensor Motion detection ecDeskSensor
SpaceWise DT Richard Cremmen
Presentation transcript:

LIGHTING MANAGEMENT | PRODUCTS & SYSTEMS PUTTING A STOP TO ENERGY WASTE LIGHTING MANAGEMENT SYSTEM PUTTING A STOP TO ENERGY WASTE

LIGHTING MANAGEMENT | PRODUCTS & SYSTEMS PUTTING A STOP TO ENERGY WASTE Ambitions “Legrand makes buildings more energy efficient through lighting controls”

LIGHTING MANAGEMENT | PRODUCTS & SYSTEMS PUTTING A STOP TO ENERGY WASTE LEGRAND LIGHTING MANAGEMENT PHILOSOPHY  Maximize Day lighting Day light is by far the best light source. It's free, sustainable and can give a sense of energy and well being.  Keep control Combine automatic control with manual, scene & time-based control to offer the desired light when where required. BE SMART WITH YOUR LIGHTING CONTROL AND PUT A STOP TO ENERGY WASTE

LIGHTING MANAGEMENT | PRODUCTS & SYSTEMS PUTTING A STOP TO ENERGY WASTE Day Light level control Occupancy & Vacancy-based control Dimming control Scheduled control LEGRAND LIGHTING MANAGEMENT PHILOSOPHY 4 FUNDAMENTALS of Lighting management for -Energy & money savings, -Comfort & well being

LIGHTING MANAGEMENT | PRODUCTS & SYSTEMS PUTTING A STOP TO ENERGY WASTE LIGHTING MANAGEMENT STRATEGIES A variety of lighting mangement strategies TIPSLux set point ≠ Day light harvesting Day light level control

LIGHTING MANAGEMENT | PRODUCTS & SYSTEMS PUTTING A STOP TO ENERGY WASTE LIGHTING MANAGEMENT STRATEGIES A variety of lighting mangement strategies TIPSIdeal for corridors, lobbies, stairs

LIGHTING MANAGEMENT | PRODUCTS & SYSTEMS PUTTING A STOP TO ENERGY WASTE LIGHTING MANAGEMENT STRATEGIES A variety of lighting mangement strategies TIPSIdeal for individual offices, meeting rooms

LIGHTING MANAGEMENT | PRODUCTS & SYSTEMS PUTTING A STOP TO ENERGY WASTE LIGHTING MANAGEMENT STRATEGIES A variety of lighting mangement strategies TIPSComplete occupancy & vacancy control

LIGHTING MANAGEMENT | PRODUCTS & SYSTEMS PUTTING A STOP TO ENERGY WASTE LIGHTING MANAGEMENT STRATEGIES A variety of lighting mangement strategies TIPSOffer visual comfort

LIGHTING MANAGEMENT | PRODUCTS & SYSTEMS PUTTING A STOP TO ENERGY WASTE 1 KEY product: the sensor LEGRAND LIGHTING MANAGEMENT PHILOSOPHY  The right sensor Detection adapted to the environment Day-light measurement Load control  At the right place  With the right adjustment

LIGHTING MANAGEMENT | PRODUCTS & SYSTEMS PUTTING A STOP TO ENERGY WASTE 1 KEY product: the sensor LEGRAND LIGHTING MANAGEMENT PHILOSOPHY  The right sensor Detection adapted to the environment UltrasonicDual 3 detection Technologies PIR. MOTIONOBSTACLES SMALL MOVEMENTS

LIGHTING MANAGEMENT | PRODUCTS & SYSTEMS PUTTING A STOP TO ENERGY WASTE 3 Detection technologies LEGRAND LIGHTING MANAGEMENT PHILOSOPHY PIR Passive infrared technology detects occupancy by reacting to infrared energy sources (such as a human body) in motion. Ultrasonic The sensor emits ultrasonic sound waves that bounce off objects in the covered space, and then measures the amount of time it takes for the waves to return. Dual Occupancy sensors with multiple sensing technologies are usually referred to as 'dual technology' or hybrid devices. Most commonly, PIR and ultrasonic technologies. Technologies Sensors use a variety of technologies in order to detect occupants and send appropriate signals to lighting devices.

LIGHTING MANAGEMENT | PRODUCTS & SYSTEMS PUTTING A STOP TO ENERGY WASTE LIGHTING MANAGEMENT TECHNOLOGIES PIR sensor detects occupancy through the difference between heat emitted by body in motion and the ambient space. Passive Infra Red Sensing Symbol Heating sources Technology to be used in obstacle free open areas

LIGHTING MANAGEMENT | PRODUCTS & SYSTEMS PUTTING A STOP TO ENERGY WASTE LIGHTING MANAGEMENT TECHNOLOGIES Occupancy Motion Motion detection Outdoor: drive ways, entrance, car parks Indoor: : garages, corridors, store rooms Occupancy detection Indoor: offices, warehouses, Best suited for obstacles free areas

LIGHTING MANAGEMENT | PRODUCTS & SYSTEMS PUTTING A STOP TO ENERGY WASTE Tips for PIR Sensors placement The PIR sensors must be located where there will be no obstacles blocking the person to be detected PIR must not be able to “see” outside the desired detection area Better detection can be achieved when a person crosses the detection areas s s s No! No Detection!

LIGHTING MANAGEMENT | PRODUCTS & SYSTEMS PUTTING A STOP TO ENERGY WASTE LIGHTING MANAGEMENT TECHNOLOGIES Ultrasonic detection operates by transmitting ultrasonic sound waves throughout an area and measuring the speed at which they come back. Occupant movement changes the frequency at which sound waves return. Ultrasonic detection Symbol Technology to be used in enclosed areas that are obstructed by obstacles Air flow sources

LIGHTING MANAGEMENT | PRODUCTS & SYSTEMS PUTTING A STOP TO ENERGY WASTE LIGHTING MANAGEMENT TECHNOLOGIES Occupancy Motion Motion detection Outdoor: none Indoor: : store rooms with shelves Occupancy detection Indoor: toilets, washrooms Best suited for enclosed areas obstructed by obstacles

LIGHTING MANAGEMENT | PRODUCTS & SYSTEMS PUTTING A STOP TO ENERGY WASTE Tips for Ultrasonic Sensors placement Ultrasonic sensors can detect occupancy even though there might be obstacles between the sensor and the moving person Undesired detection outside the controlled area should be avoided They should be located away from air flows such as AC currents, fans and mounted of still surface u u No! u A/C

LIGHTING MANAGEMENT | PRODUCTS & SYSTEMS PUTTING A STOP TO ENERGY WASTE LIGHTING MANAGEMENT TECHNOLOGIES We combine the best of both technologies: PIR (ideal for cross detection) and US (ideal for front detection). The sensor switches on the lights when both sensing technologies detect presence, and keeps lighting on as long as one technology continues to detect. Dual-Tech Sensing Symbol And Combination of PIR and Ultrasonic technologies to benefit from the strengths of both while at the same time eliminating their weaknesses!

LIGHTING MANAGEMENT | PRODUCTS & SYSTEMS PUTTING A STOP TO ENERGY WASTE LIGHTING MANAGEMENT TECHNOLOGIES Occupancy Motion Best suited for obstacles free areas with low movements Motion detection Outdoor: none Indoor: : storage areas, stock rooms Occupancy detection Indoor: classroom, open spaces, meeting rooms

LIGHTING MANAGEMENT | PRODUCTS & SYSTEMS PUTTING A STOP TO ENERGY WASTE Tips for Dual Sensors placement Dual sensors can detect occupancy skipping obstacles due to their intrinsic ultrasonic capability If occupancy must for the first time be determined by both PIR and ultrasonic technologies simultaneously, the sensor should be located where it can “see” the person Mount it on a vibration proof surface d Ultrasonic u No! u A/C

LIGHTING MANAGEMENT | PRODUCTS & SYSTEMS PUTTING A STOP TO ENERGY WASTE 1 KEY product: the sensor LEGRAND LIGHTING MANAGEMENT PHILOSOPHY  The right sensor Detection adapted to the environment Day-light measurement Constant day light measurement = capacity to turn off or dim down artificial lights when natural light is sufficient

LIGHTING MANAGEMENT | PRODUCTS & SYSTEMS PUTTING A STOP TO ENERGY WASTE LIGHTING MANAGEMENT | PRODUCTS & SYSTEMS PUTTING A STOP TO ENERGY WASTE 11 Still in the room. The detector switches on the light automatically Leave the room. Switch off with the push-button. If forget, the detector will switch off the light automatically. Stay in the room. The sensor is going to switch off the light automatically if the level of brightness is reached (1) At the start: no lighting (1) If need to maintain the light on, just have to press the push-button. High luminosity Decrease of the Lighting Departure: end of day Enter the room. Turn on the light with the push-button. Daylight : Dynamic Measurment SWITCH SENSOR SOLUTION

LIGHTING MANAGEMENT | PRODUCTS & SYSTEMS PUTTING A STOP TO ENERGY WASTE LIGHTING MANAGEMENT | PRODUCTS & SYSTEMS PUTTING A STOP TO ENERGY WASTE Daylight : Active Measurment Cycle ON-OFF 11 10mn 20s LUMINOSITY Luminosity Rise Luminosity Setpoint 1 st Detection Step-down regulation Step-up regulation TIME Natural Daylight Artificial Light Daylight + Artificial Light SWITCH SENSOR SOLUTION

LIGHTING MANAGEMENT | PRODUCTS & SYSTEMS PUTTING A STOP TO ENERGY WASTE LIGHTING MANAGEMENT | PRODUCTS & SYSTEMS PUTTING A STOP TO ENERGY WASTE This type of regulation enables the light level of the room to be constantly varied and adjusted. We have chosen an algorithm for a rapid increase in the light level, so that the occupant always has an adequate level, and a slow decrease in the light level. The time taken to decrease from 100% to 1% can vary between 30 minutes and 90 minutes. Daylight : Active Measurment Cycle DImming SWITCH SENSOR SOLUTION

LIGHTING MANAGEMENT | PRODUCTS & SYSTEMS PUTTING A STOP TO ENERGY WASTE LIGHTING MANAGEMENT | PRODUCTS & SYSTEMS PUTTING A STOP TO ENERGY WASTE Daylight : Installation Rules 11 h hw L SWITCH SENSOR SOLUTION

LIGHTING MANAGEMENT | PRODUCTS & SYSTEMS PUTTING A STOP TO ENERGY WASTE 1 KEY product: the sensor LEGRAND LIGHTING MANAGEMENT PHILOSOPHY  The right sensor Detection adapted to the environment Day-light measurement ON-OFF or DIMMING CONTROL for all types of loads. LEDs, FLUO, DALI & 1-10V ballasts Load control

LIGHTING MANAGEMENT | PRODUCTS & SYSTEMS PUTTING A STOP TO ENERGY WASTE 1 KEY product: the sensor LEGRAND LIGHTING MANAGEMENT PHILOSOPHY  The right sensor  At the right place Adapted mountings Indoor & Outdoor.Wall, flush, ceiling mounting Detection drawings

LIGHTING MANAGEMENT | PRODUCTS & SYSTEMS PUTTING A STOP TO ENERGY WASTE 1 KEY product: the sensor LEGRAND LIGHTING MANAGEMENT PHILOSOPHY  The right sensor  At the right place  With the right adjustment Necessity to adjust precisely time, lux, mode parameters to secure savings

LIGHTING MANAGEMENT | PRODUCTS & SYSTEMS PUTTING A STOP TO ENERGY WASTE Better Detection for all kinds of area Switch Sensors The Legrand promises for INVESTORS Optimum Energy savings –PERFORMANCE OF DETECTION 3 detection technologies to give appropriate answer to any application Dual-technology  security to detect small movement –Detection scheme combination: initial, maintain Visualization of detection through LED blinking Additional functions: walkthrough function, audible alert –PERFORMANCE OF DAY LIGHTING Constant day-light harvesting: precise measurement in Lux Capability to turn artificial light off when natural light is sufficient Combination with Luxmeter –PERFROMANCE OF COMMISIONING Capability to download all sensors parameters: secure commissioning, Norms conformity 3 main operations consult, check, save –AESTHETICS Flat sensors A secured configuration

LIGHTING MANAGEMENT | PRODUCTS & SYSTEMS PUTTING A STOP TO ENERGY WASTE THANK YOU