ERICSSON MICROWAVE COMMISSIONING GUIDELINES

Slides:



Advertisements
Similar presentations
Introduction. Introduction: Things to Prepare before Assembly Anti-static wrist strap Set of screwdrivers and pliers Piece of cloth CPU Thermal compound.
Advertisements

Microsoft windows By Sadat Kemal Mohammed
Orion Telecom Networks Inc Slide 1 STM-1 63 E1 (Optical / Electrical) SDH Add-Drop Multiplexer Updated: Dec, 2010Orion Telecom Networks Inc
PowerEdge M-Series CMC Management
Digital RF Stabilization System Based on MicroTCA Technology - Libera LLRF Robert Černe May 2010, RT10, Lisboa
SGI Confidential Copan 400 Installation. SGI Confidential Installation Overview The approximate minimum time to complete this procedure is.
MINI-LINK TN ETSI Technical
3U ATCA Shelf October Proprietary and Confidential-
DASAN NETWORKS GPON Training
Presents The Silver Family An Integrated Approach to Processors, Data Communication and Head End Integration.
Lesson 15 – INSTALL AND SET UP NETWARE 5.1. Understanding NetWare 5.1 Preparing for installation Installing NetWare 5.1 Configuring NetWare 5.1 client.
DP Cabinet.
SGI Confidential Application Processor. SGI Confidential Application Processor Overview Application Field Replaceable Units The Application.
MUST HAVE SHOULD HAVE COULD HAVE Module # 010. Qi Hardware Objectives Recognize hardware Know how to interface to field equipment Know the 4 different.
VCL-MX Version 6 DXC 80 E1, 160Mbps Digital Access Cross Connect Switch.
Orion Telecom Networks Inc Slide 1 4 x Ethernet over E1(4*FE1) Updated: April 2010Orion Telecom Networks Inc Ethernet over E1 (4xFE1)
Dainis Krakops’ Wireless Network MOTOROLA SURFboard SB5101 CABLE MODEM Enables cable operators to provide broadband Internet connection for my LAN devices.
Chapter 7Assembling Your Own Computer System  7.1Assembling the Hardware 7.1Assembling the Hardware 7.1Assembling the Hardware  7.2Installing the Operating.
Lecture’s Biography Lecture ISAM 7302/7330 Speaker Mao Monirum Phone
Field Proven Performance – Industrial Grade Support DATA-LINC GROUP Training: LincView OPC Released: 2012/02/04.
XP Practical PC, 3e Chapter 17 1 Upgrading and Expanding your PC.
System Elements HighPoint Broadband Delivery System Sector 1 Sector 3
Chapter 1 An Introduction to Networking
1 P ROTEUS AMT Adaptive Modulation Transport. 2 Product Overview AMT-Series Indoor Unit Outdoor Unit L-Series Indoor Unit.
Tutorial 11 Installing, Updating, and Configuring Software
Embedded Sales Meeting COM Express Carrier. COM Express Carrier Card What is it? –Two PMC slot or two XMC slot on the top side of the board and one COM.
Identifying SLC 500™ System Components. SLC 500 System Options  The SLC 500 line of processors comprises both fixed and modular processor styles.:
Chapter 7 AC 800M Hardware Course T314.
Slide 1 Orion Telecom Networks Inc Slide 1 VCL-MX Version 2 – DLX (Deluxe Version) xcvcxv Updated: September 2010Orion Telecom Networks Inc
Hands-On Virtual Computing
All rights reserved © 2010, Mobiserve Prepared By: RIZWAN AHMED RAFIQ Operation Support Engineer (Training & Consultancy) ALCATEL BTS.
MXclusters, Redundancy, XRS12, EPA3 Yang Guo Manager of Business Development for Asia Pacific.
Ch Review1 Review Chapter Microcomputer Systems Hardware, Software, and the Operating System.
E1 / T1 Series Product Introduction.
What does a Computer Do?. What is a Computer? A computer is an electronic device, operating under the control of instructions stored in its own memory,
Basic LAN techniques IN common with all other computer based systems networks require both HARDWARE and SOFTWARE to function. Networks are often explained.
XS26-2 Expandable Safety Controller.
Repeaters and Hubs Repeaters: simplest type of connectivity devices that regenerate a digital signal Operate in Physical layer Cannot improve or correct.
SGI Confidential Power Bay. SGI Confidential Power Bay Front View AC OK LED DC OK LED Alarm LED Release Latch Power Bay 1 Power Bay 0 Power.
EMerge Browser Managed Security Platform Module 3: Startup eMerge Certification Course  Physical connection  TCP/IP Characteristics of PC  Initial connection.
Otasuke GP-EX! Chapter 11 GP-Viewer EX
 The Control Panel window will pop up. Existing LAN USB-to-Ethernet adapter  Use an inexpensive USB-to-Ethernet adapter and connect it to your computer’s.
 The devices which each intercorrect several computer or different to each other, each nones network devices.  There are various types of Network devices.
Hardware Training Product: ITMS2.
Orion Telecom Networks Inc Slide 1 Ethernet over E1(FE1) Updated: April 2010Orion Telecom Networks Inc Ethernet over E1 (FE1) Product Presentation.
COMMUNICATION INFOTECH. BTS COMMISSIONING Switch of the bts cabinet & disconnect a bts connectors from DDF before offline start Disconnect the bts connection.
-Proprietary and Confidential-
Computer Hardware Maintenance & Repairs Computer Hardware Maintenance & Repairs Suleiman Mohammed (mncs,mcpn) Instructor Institute of Computing & ICT,
CIMON TOUCH KDT SYSTEMS Introduction  Excellent Durability  The mobile CPU of the TOUCH gives excellent durability under industrial environment.
1 Syllabus at a glance – CMCN 6103 Introduction Introduction to Networking Network Fundamentals Number Systems Ethernet IP Addressing Subnetting ARP DNS.
Overview of Fylde MPT1327 Trunking Equipment & Features OR
TOPIC 1.3 INTRODUCTION TO NETWORKING. Router – A netwok interconnection device & associated software that links two networks. The networks being linked.
Information Systems Technology Ross Malaga A Copyright © 2005 Prentice Hall, Inc. A-1 INSIDE YOUR COMPUTER.
VCL-SE IEEE-1588v2 PTP Protected Synchronous Packet-Optical Transport Interface Presentation.
Rohde & Schwarz Topex TOPEX IP Radio Gateway July 2011.
AEON 4000 Including the SMPS 4000 rectifier and the AEON Gold Alarm & Monitoring Unit.
A Competitive Overview Jon Cramer and Steve Floth Regional Sales Managers.
Enclosures & ComponentsBackplanesSystem PlatformsSwitches, Knobs & LEDsCabinets Friedrich Fix 1 AdvancedTCA Systems Platforms according to PICMG.
1 © 2016 Samsung Electronics America - Confidential Introducing MagicInfo Lite I 4.0.
LAN Connections.
CMV-NET Chigo VRF Network Centralized Control System
Chapter Objectives In this chapter, you will learn:
ETS Inside Product Launch
Computer and Information Technology for HKCEE
Introducing MagicInfo Lite I 4.1
Ericsson Microwave Products Overview
Indoor GPON ONT September 2010.
Vertical Cryostat Kick-off metting
VCL-MX™ Version 2-DLX (Deluxe Version) 4 x E1, 30 Channel Drop-Insert
VCL-MX™ Version 3-STD (Standard Version)
Presentation transcript:

ERICSSON MICROWAVE COMMISSIONING GUIDELINES

INTRODUCTION TO ERICSSON MINI LINK CRAFT Overview: The Ericsson MW Indoor comprises of the following: Radio Transmission Cabinet (RTC) AMM (Access Module Magazine) The RTC is the cabinet where the Ericsson equipment are been installed. Within it you have the AMM and other equipment like the SAU e.t.c

Access Module Magazine (AMM) The AMM is like empty mini equipment which in it can accommodate various Modules. The indoor plug-in units are installed in an AMM. The AMM can be fitted directly into a 19” or metric rack. It provides the mechanical housing and interconnection for the plug-in unit’s through the backplane. It has different slots according to design specification. There are like three (3) Design Specifications for AMM: 2p Magazine 6p Magazine 20p Magazine Each specification is according to the number of MMU cards/ Site Design.

2p Magazine 6p Magazine

AMM 2p The AMM2p has two half-height slots, one equipped with NPU3, NPU3B, or NPU3C, the remaining half-height slot can be equipped with LTU, ETU, SAU or SXU. The power supply is not included in NPU3, NPU3B, or NPU3C; it is separately integrated in the AMM on the left hand side. At the Right Hand Side are slots for Two (2) MMU’s. The AMM Kit delivery comprises: One assembled AMM 2p One Rack Screw Kit One Earthen Cable, 1m One NPU3, or One NPU3B, or One NPU3C. One RMM Two MMU Note: AMM2p requires a DC cable RPM517560/nnnn which must be purchased separately.

AMM 6p AMM 6p C or D have four (D) or five(C) full-height horizontal slots, four (D) or two(C) half-height horizontal slots and two half-height vertical slots. They house one NPU3, NPU3B, or NPU3C, one or two PFU3B, and one FAU2. The remaining slots in AMM6pC/D can be equipped with MMU, LTU, SAU, AAU, SXU, SMU or ETU. An AMM6pC/D Kit delivery comprises: One assembled AMM6pC or one assembled AMM6pD One Rack Screw Kit One Earthling Cable, 1m OneNPU3, or One NPU3B, or One NPU3C One RMM One DC Connector Kit One FAU2 One PFU3B, (one additional PFU3B Kit is needed for redundancy)

AMM 20p The AMM20p has twenty full size slots of which 10 are available as standard. Additional slots can be made available by ordering the optional feature “AMM20p Slot Extension”. The NPU1B or NPU1C occupies one slot. One or two PFU1 are fitted in dedicated slots at the left hand side of the AMM. The AMM20pB -10R4 Kit delivery with 10 available slots comprises: One assembled AMM20p Two Rack Screw Kits One DC Connector Kit One Earthing Cable, 1m One NPU1B, or One NPU1C One RMM One Cable Shelf, an additional cable shelf can be used when routing many cables. One PFU1, one additional PFU1 Kit is needed for redundancy One Fan Alarm Cable Note: Power Input for all magazines is -48v, this tells in the breaker each power cable should be terminated.

The Node Processor Unit (NPU) An NPU provides the main control system functions and holds a Removable Memory Module (RMM) for storage of license and configuration information. In addition to this, it provides some traffic handling functions and interfaces, but which ones are depending on type of NPU. The different types are: NPU1 B: used for AMM 20p B provides user I/O interfaces, eight unstructured E1 interfaces, an Ethernet interface for Site LAN, and a USB port for local management. NPU1 C: used for AMM 20p B provides User I/O interfaces, eight unstructured E1 interfaces, one combined Ethernet Site LAN/traffic interface and one Ethernet Traffic interface, two Ethernet SFP interfaces, and a USB port for local management. It contains a non-blocking gigabit Ethernet switch. The switch is a managed VLAN switch (IEEE 802.1Q and IEEE 802.1D) and HW prepared for Provider Bridge switching (IEEE 802.1ad). NPU3: for AMM 2p, 6p C, and 6p D, provides four unstructured E1 interfaces, one Ethernet Site LAN and one Ethernet Traffic interfaces, two User Outputs, and one USB port for local management. NPU3 B: Provides four Unstructured E1 interfaces, one combined Ethernet Site LAN/traffic interface and one Ethernet Traffic interface, two User outputs, and one USB port for local management. It contains a non-blocking gigabit Ethernet switch. The switch is a managed VLAN switch and HW prepared for provider bridge switching. NPU3 C: Provides four unstructured E1 interfaces, one combined Ethernet Site LAN/traffic interface and one Ethernet Traffic interfaces, two User Outputs, and one USB Port local management. It contains a non-blocking gigabit Ethernet switch. The switch is a managed VLAN switch and HW prepared for provider bridge switching. The NPU3 C supports Synchronous Ethernet.

Modem Unit (MMU) The MMU is the indoor interface with the radio unit. One MMU is required per radio unit. Note: Before you slot in your MMU, make sure you have Connected your IF cable properly.

System Requirement in Commissioning of Ericsson MW link A laptop Computer USB Cable Microsoft Operating System OS XP, Vista, Windows 7 Mini link Craft version 2.13 Software running on your laptop

Parameters needed for Configuration TX frequency TX Power Capacity/number of E1’s Modulation

Step by Step Procedure in Configuration Connect your laptop to the NPU Card using the USB cable (USB port on your laptop to the USB port on the NPU card) Lunch your Mini link Craft Application Type in the IP address, User, and Password. IP: 10.0.0.1, User: control_user, Password: ericsson; and click “login”.

@ The ‘Alarms and Status Page’, click on the Site name at the Left Hand Side of the screen. Click on ‘AMM 2p B’ (that’s the type of magazine been installed) still the RHS of the Screen. Select ‘MMU2 D’ and Right Click on it. On the drop down menu options, click on the option ‘Configure Radio link’. Start to input the parameters as required by the fields. When you are through, at the top left of the screen click on ‘Save’ Your configuration parameters are saved in the RMM and you are ready for alignment. Close the page.

THANK YOU