ClearFire-LC Hydronic Boiler Solution. ClearFire Family Capacities from 400 to 12,000 MBH 2 ClearFire-H - Steam ClearFire-C - Condensing ClearFire-V -

Slides:



Advertisements
Similar presentations
Boilers Presented by: Lisa Chang Objective: To describe and explain the boilers functions and the two main types of boilers.
Advertisements

Boilers & Thermic Fluid Heaters
1 BOILERS AND EFFICIENCY Gary Archer Vice President of Sales JW Stevens Co.
HVAC523 Heat Sources.
ENERGY CONVERSION MME 9617A Eric Savory
Energy Efficient Steam Systems
Energy Efficiency and Conservation Program Overview Taking the heat off the bottom line…
Assumptions: Incompressible substance, B. Negligible heat transfer
VF™ Series Boiler.
TYPES OF MECHANICAL SYSTEMS
Exhaust Heat Recovery Systems
Heat Recovery for Commercial Buildings
PARKER BOILER PARKER BOILER HOT WATER PIPING SYSTEM 1. 3 way valve and O.S.A. reset. 2. Single boiler piping schematic. 3. Single boiler with 3 way valve.
Learning Outcomes Upon completion of this training one should be able to: Identify open loop and closed loop campus-type hydronic water system applications.
Energy Efficient Steam Systems. Steam Systems Steam systems most widely used type of process heating Advantages of steam: –Heat carrying capacity of steam.
Honeywell Proprietary 1 Document control number 4/11 Rev 0 Marketing - Muncie Ultra Low Emissions Burner.
Elliott Microturbines Absorption Chiller Integrated System Development
Introduction to the BRYAN 1. 2 Quality Construction Features Standard Operating Parameters ­Maximum Boiler Design Pressure  All Models – 160 Psig ­Maximum.
An independent heating system consists of: 1) wall-mounted boiler flue 2) manifold of copper and its connection to the boiler 3) internal boiler chimney.
Engineered Products Make-Up Air for Heating and Cooling.
Bachelor Degree in Maritime Operations (BMO)
Generation and Control of Vacuum in Furnace
Power Plant Construction and QA/QC Section 2.4– Boiler Auxiliaries
Presented by: Terry Stohs Viessmann Manufacturing Company Inc.
Engineer Presentation
“Energy Efficiency Guide for Industry in Asia”
Steam Power Plant.
RETScreen® Energy Efficiency Projects
UTSW Thermal Energy Plants, Power Generation and Electrical System What do we do to meet the Emission Reduction, Energy usage Reduction and Electrical.
POWER GENERATION TECHNOLOGIES
Combined_Cycle_Power_Plant Prepared by: Nimesh Gajjar.
Power Generation Cycles Vapor Power Generation The Rankine Cycle
Refrigeration and Heat Pump Systems Refrigeration systems: To cool a refrigerated space or to maintain the temperature of a space below that of the surroundings.
Thermo-economic Optimization of STHE P M V Subbarao Professor Mechanical Engineering Department I I T Delhi Minimizing capital and operating costs of shell.
Lesson 7 Steam Power Plant.
Exergy Analysis of STHE P M V Subbarao Professor Mechanical Engineering Department I I T Delhi Formalization of Thermo-economics…..
Gas Turbine Power Plant
8/27/ ENERGY VS EFFICIENCY Bob Witt CPD.
Prof. D.N. Reddy Director Centre for Energy Technology University College of Engineering Osmania University.
Perfect solution for large building
Outline (1) Heat Exchanger Types (2) Heat Exchanger Analysis Methods
Plant Utility System (TKK-2210) 14/15 Semester 4 Instructor: Rama Oktavian Office Hr.: M-F
NOVO ETS IMPROVING YOUR ORGANIZATIONS’ ENVIRONMENTAL, HEALTH AND SAFETY PERFORMANCE ENERGY MANAGEMENT IN THE CONTEXT OF GREEN PRODUCTIVITY.
COMMERCIAL BOILERS. HIGH MASS Advantages Flow Indifferent Primary Piping Resistant to low return temperature issues Up to 1200 H.P. 20 plus year life.
Heating Cost for 5000 Gallons of Water at 100 o T $ % 90% 80% $30.87$29.15 Thermal Efficiency Daily Operating $0.63/Therm.
Bachelor Degree in Maritime Operations (BMO) Diesel Technology and Emissions Waste Heat Recovery Lecturer: Mr. Kalyan Chatterjea Presented By: Tam Kong.
The key to comfort and reduced fuel use for all heating systems.
Seamless Solutions from Study to Revamp tailor made solutions at least cost with minimum outlay We deliver Moscow / St Petersburg, March 2011.
1 System planning 2013 Lecture L9: Short term planning of thermal systems Chapter Contents: –General about thermal power –Production cost –Start.
World Leaders in Combustion Management Solutions PID Control (P)roportional (I)ntegral Internal Stat PID (D)erivative Further.
World Leaders in Combustion Management Solutions Training School Autoflame Training 2013 PID.
Boilers Present By: Jason Gillier 4M-H. OBJECTIVE: To provide the audience with a brief, but concise overview of what boilers are and there components.
Baldwin Wallace College (Berea, Ohio). Two KN20 boilers installed to replace old atmospheric cast iron boilers. KN boilers are true cast iron sectional.
Exquisite Heat For Steam Boilers. Time based system  Thermostat Demand Analysis over time will determine the length of burner fire time of the boiler.
THERMAL POWER PLANT.
1 Hospital Building and Campus Piping. 2 Hospital Building Occupancy – office and patient areas Patient areas: 24 hours per day Office areas: 8 am – 5.
Condensing Hydronic Heat Exchangers Make-Up Air Units Meets.
7/15/2002PP.AFD.09 1 of 43 Yaskawa Electric America Variable Frequency Drives In HVAC Applications.
I Need A Space Heating System Let’s Look At A Central Steam Plant Option.
CIBSE HCNW 28 August 2014 Modular boilers. Traditional or low-tech replacement boiler installation; Multiple boilers eg 2 no 66% of load for security.
I-RACH range I-RACH range I-RACH range I-RACH range High efficiency air/water heat pump with INVERTER scroll compressor Range Modularity Components Highlights.
R.N.S. INTERNATIONAL Heat Pumps
Lesson 7 Steam Power Plant.
Exhaust Heat Recovery Systems
Elliott Microturbines Absorption Chiller Integrated System Development
Exhaust Heat Recovery Systems
Presented By: Jim Lombardo Herbert & Conway, Inc.
“Desuperheater” High Efficient Energy conservation Device for Refrigeration Use
Flo-Direct®.
Presentation transcript:

ClearFire-LC Hydronic Boiler Solution

ClearFire Family Capacities from 400 to 12,000 MBH 2 ClearFire-H - Steam ClearFire-C - Condensing ClearFire-V - Steam ClearFire-W - Near Condensing ClearFire-LC - Condensing

ClearFire-LC Overview Total integration in a small footprint with unprecedented power for hydronic applications New in 2013, the revolutionary CFLC line provides maximum flexibility for larger facilities with enhanced efficiency The larger capacity design allows the most effective installation by using fewer units as opposed to banks of smaller boilers, thus reducing capital cost, complexity and maintenance Rounds out the ClearFire product offering 3

ClearFire-LC Features Fully condensing hydronic boiler Ultra-low emissions True counter-flow heat transfer – up to 99% efficiency Maximized effective heating surface Reduce energy consumption by as much as 40–50% compared to traditional non-condensing boiler systems Standard 5:1 turndown Compact footprint and application versatility for maximum design flexibility Complete factory integrated package Standard design: ASME Section IV Hot Water 160# MAWP, 250F MAWT cULus Listed, ASME CSD-1 4

ClearFire-LC 5 Six sizes ranging from 4,000 to 12,000 MBTU/hr Can support facilities requiring as much as 96,000 MBH in one condensing heating plant – when implementing our integrated lead-lag control with up to 8 boilers Capacity 4000=4,000 MBTU/hr 5000=5,000 MBTU/hr 6000=6,000 MBTU/hr 8000=8,000 MBTU/hr 10000=10,000 MBTU/hr 12000=12,000 MBTU/hr

ClearFire-LC 6 Applications Building Heating, Process Heating Institutional: hospitals, schools, universities Larger office, hotels or corporate campuses Hybrid hydronic heating systems – new and retrofit Any hydronic system requiring fewer number of condensing boilers Applications Building Heating, Process Heating Institutional: hospitals, schools, universities Larger office, hotels or corporate campuses Hybrid hydronic heating systems – new and retrofit Any hydronic system requiring fewer number of condensing boilers

ClearFire-LC 7

8 ClearFire-LC Optimized Heat Exchanger True Counter-Flow Arrangement EX Spiral Tubes Premix Gas Burner SS AluFer® Tubes

9 ClearFire-LC Optimized Heat Exchanger Water Supply Outlet Large Water Volume Low Water- side Pressure Drop Low Flow Tolerant Thermal Shock Resistant No Minimum Return Temp Water Return Inlets

10 ClearFire-LC Dual Temperature Returns Low Temperature Return Inlet High Temperature Return Outlet Enhanced Condensing Performance More Energy Saving Opportunities

11 ClearFire-LC Premix Burner, Ultra-Low Emissions Combustion Air Inlet Venturi Fuel Train Full Modulation With 1:1 Fuel-Air Ratio Control Flue Gas Outlet Flue & Condensate Collection Chamber Low Emissions – Linear PID Modulation Variable Speed Premix Blower

12 ClearFire-LC Integrated Control Built-In Lead-Lag (Up To 8 Boilers), Outdoor Reset & Pump/Valve Control Falcon Hydronic Control Building Energy Management System Interface To Minimize Energy Wasting Short Cycling

More Resources Click hereClick here for specs, technical data and drawings Click hereClick here for product brochure Click hereClick here for AHRI certified ratings Click hereClick here for tip sheet Click hereClick here to find a representative 13