Electrocardiogram (ECG) PhillipN, (2007) Display device of a medical monitor as used in anesthesia [photograph]. Retrieved from https://en.wikipedia.org/wiki/Monitoring_(medicine)#/media/File:Monitor_(medical).jpg.

Slides:



Advertisements
Similar presentations
CHAPTER 12 CARDIOVASCULAR SYSTEM
Advertisements

Circulatory Adaptations to Exercise
C h a p t e r 20 The Heart PowerPoint® Lecture Slides prepared by Jason LaPres Lone Star College - North Harris Copyright © 2009 Pearson Education, Inc.,
ECG Signal Processing Ojasvi Verma
Cardiovascular System Block The Electrocardiogram (ECG)
Aims Introduction to the heart.
The Heart Circulatory System.
ECE 501 Introduction to BME ECE 501 Dr. Hang. Part IV Bioinstrumentation Electrocardiogram ECE 501 Dr. Hang.
Location and function (13.0) Location: to the left of the midline in the Thoracic Cavity –Between the lungs and above the diaphragm Function: Pump blood.
The Circulatory System. Do you remember when you were little and had an earache and your parents gave you medicine to take? Were you confused as to how.
Transport system to carry oxygen and nutrients to all of the cells in the body. Takes away waste products (like CO2) Heart pumps blood continuously Uses.
Heart Actions Cardiac Cycle: One complete heartbeat. The contraction of a heart chamber is called systole and the relaxation of a chamber is called diastole.
CARDIAC CYCLE Renee Anderson.
C h a p t e r 20 The Heart PowerPoint® Lecture Slides prepared by Jason LaPres Lone Star College - North Harris Copyright © 2009 Pearson Education, Inc.,
A Case of Dizziness A 68 year old female arrives at the emergency room in an ambulance. That evening she had been feeling “weak and dizzy” after ingesting.
Chapter 13 HEART.
Color-Coded Cables Placement Black and white on front limbs – Placed at the elbow region Green and Red on back limbs – Placed at the stifle region Alcohol,
Cardiovascular System
CARDIOVASCULAR SYSTEM PHYSIOLOGY. Pulmonary circulation: Path of blood from right ventricle through the lungs and back to the heart. Systemic circulation:
Cardiovascular System
Chapter Goals After studying this chapter, students should be able to describe the general functions of the major components of the heart. 2. describe.
S. MORRIS Main functions: 1.Transports gases (from the respiratory system), nutrient molecules and waste materials (from the digestive system) 2.Regulates.
Exercise Science The Cardiovascular System Learning Goals Blood flows with oxygen to areas of need, then returns with waste products to be re oxygenated.
Heart. Closed Circulation Blood never leaves vessels Blood never leaves vessels.
Dr. Mona Soliman, MBBS, MSc, PhD Department of Physiology Chair of Cardiovascular Block College of Medicine King Saud University.
ECG How ECG is done? The electrical impulses originating from the heart can be transmitted to the body surface because the body contains fluids.
Electrocardiographs ECG. OUTLINES : Introducing what is meant by Biopotential signals. what is Electrocardiograph (ECG). The conduction system. The standard.
The Hearts Electrical Activity
Cardiovascular System. Functions of Cardiovascular System 1. generate blood pressure 2. send oxygenated blood to organs 3. insure one-way blood flow 4.
REVIEW: LABELED HEART DIAGRAM
Blood Flow Steps 1. Caudal/Cranial Vena Cavae 2. Right atrium 3. Tricuspid/Right AV Valve 4. Right ventricle 5. Pulmonary/pulmonic valve 6. Pulmonary arteries.
Circulation What is the pathway of the blood flow in the body?
HEART PHYSIOLOGY. What a Job!  It pushes your six liters of blood through your blood vessels over 1000 times a day!  Thousands of cells function as.
The Heart: ECG Signal The Heart: ECG Signal. Basic structure of the heart.
Starter Questions What is the difference between circulatory systems between unicellular and multicellular organisms. How many chambers does the heart.
How the Heart Works. Electrical activity in the heart.
Electrocardiography for Healthcare Professionals
Introduction to the EKG. Electricity of the Heart The contraction of any muscle is associated with electrical changes called depolarizations and can be.
Chapter 12 Circulation Sections 1 and 2 The Body’s Transportation and A Closer Look at Blood Vessels.
Heart Beat and Blood Pressure. Heart Beat Animation ions/ ions/
Cardiac Muscle In The“Heart” of Muscles. Introduction Take a look the instruments that are laid out before you These instruments are called stethoscopes.
Electrocardiograph. History Italian scientist Carlo Matteucci realizes that electricity is associated with the heart beat Irish scientist.
The Heart Dr. Isazadehfar. Location of the Heart The heart is located between the lungs behind the sternum and above the diaphragm. It is surrounded by.
Mammalian Transport System Ch. 8 Part 4 Heart Function.
The Heart. Pulmonary Circulation and Systemic Circulation The heart is considered to be a double pump because it pumps blood through 2 different loops:
ELECTROCARDIOGRAMS. WHAT IS IT?  Measures electrical activity of the heart that is produced by the myocardium Produces a graphic recording Can be printed.
The Circulatory System
Review of 4 Weeks in 20 Minutes or Less Blood o Components: plasma, red blood cells, white blood cells, platelets o RBC have hemoglobin that carry O2 o.
Respiration Rate Apnea Monitor “Apnea Monitor.” From the publication: Core Medical Equipment. Geneva, Switzerland, 2011.
Chapter 12 – Cardiovascular System Lecture 1. Intro  Cardiovascular System has three types of blood vessels 1. Arteries 2. Capillaries 3. Veins.
Cardiovascular System Notes: Heart Disease & Disorders.
Copyright © 2004 Pearson Education, Inc., publishing as Benjamin Cummings Ch. 20 The Heart Describe the organization of the cardiovascular system. Discuss.
Defibrillators WHO. “Defibrillator, External, Automated; Semiautomated.” From the publication: Core Medical Equipment. Geneva, Switzerland, 2011.
Electrocardiogram. Basic Anatomy Heart is a muscle called myocardium Heart is a muscle called myocardium Heart has 4 chambers- right atrium, right ventricle,
ADVANCED CARDIAC MONITORING HEALTH TECH 2 LANCASTER HIGH SCHOOL.
Cardiovascular System Notes: Physiology of the Heart.
The Circulatory System
The Cardiovascular System Chapter Components 1. There are two components to the system: the heart and the blood vessels. 2. The heart pumps the.
Blood Pressure Telehealth (2010), Blood Pressure monitor [picture]. Retrieved from
The Mammalian Circulatory System
The Circulatory System
Journal#2: Damage to the semilunar valve on the right side of the heart would affect blood flow to which vessel? Objective: Explain the events of the.
The Circulatory System
©2012 Lippincott Williams & Wilkins. All rights reserved.
The Cardiovascular System (Heart)
The Heart Section 11.4.
Heart Beat and Blood Pressure
Use of artificial pacemakers to regulate the heart rate
Journal#2: Damage to the semilunar valve on the right side of the heart would affect blood flow to which vessel? Objective: Explain the events of the.
Presentation transcript:

Electrocardiogram (ECG) PhillipN, (2007) Display device of a medical monitor as used in anesthesia [photograph]. Retrieved from

Summary Clinical Use Specifications History Principles of Operation Block Diagram Commercial Examples Preventive Maintenance Common Problems Test Procedures

Typical Heart Rate Normal heart rate – 60 to 80 beats/min (5 liters/min) During Exercise – 120 to 160 beats/min (15 to 25 liters/min) Tachycardia - heart rate more than 100 beats/min (resting). Bradycardia - heart rate less than 60 beats/min (resting). Maximum Heart Rate = 220 – Age Athletes - Max HR = 160 to 220

Circulation Two separate pumps: Right Side moves deoxygenated blood to the lungs for oxygenation Left Side moves oxygenated blood to the body Which leads to two distinct circulatory systems: Pulmonary vessels to and from the lungs Systemic vessels to and from the rest of the body Vessels that move blood away from the heart are called arteries and vessels that return blood to the heart are called veins. Blausen Medical Communications, Inc. (2013), Cardiovascular System [image]. Retrieved fromhttps://en.wikipedia.org/wiki/Talk:Circulatory_system#/medi a/File:Blausen_0168_CardiovascularSystem.png

The Nernst Equation E K =  log (K i /K o ) Animation: As we discussed, the inside of the cell is slightly negatively charged (resting membrane potential of -70 to -80 mV).cell A disturbance (mechanical, electrical, or sometimes chemical) causes a few sodium channels in a small portion of the membrane to open.electrical Sodium ions enter the cell through the open sodium channels. The positive charge that they carry makes the inside of the cell slightly less negative (depolarizes the cell). When the depolarization reaches a certain threshold value, many more sodium channels in that area open. More sodium flows in and triggers an action potential. The inflow of sodium ions reverses the membrane potential in that area (making it positive inside and negative outside -- the electrical potential goes to about +40 mV inside) When the electrical potential reaches +40 mV inside (about 1 millisecond later), the sodium channels shut down and let no more sodium ions inside (sodium inactivation). The developing positive membrane potential causes potassium channels to open. Potassium ions leave the cell through the open potassium channels. The outward movement of positive potassium ions makes the inside of the membrane more negative and returns the membrane toward the resting membrane potential (repolarizes the cell). When the membrane potential returns to the resting value, the potassium channels shut down and potassium ions can no longer leave the cell. The membrane potential slightly overshoots the resting potential, which is corrected by the sodium-potassium pump, which restores the normal ion balance across the membrane and returns the membrane potential to its resting level. Now, this sequence of events occurs in a local area of the membrane. But these changes get passed on to the next area of membrane, then to the next area, and so on down the entire length of the axon. Thus, the action potential (nerve impulse or nerve signal) gets transmitted (propagated) down the nerve cell.­ Membrane potential depends of ions concentration: Na +, K +, Cl - Ionic Current

Cell Depolarization Villetakanen (Own work), Nerve Cell Depolarization [CC BY-SA 4.0 ( via Wikimedia Commons

Cell Depolarization The cardiac pacemaker cell action potential: Silvia3 (2010), Pacemaker Action Potential [image]. Retrieved fromhttps://en.wikipedia.org/wiki/Cardiac _action_potential#/media/File:Pacemaker _potential_annotated.gif

Heart’s Anatomy Wikipedia. “Heart.” Wikipedia, p Retrieved from:

Four-chambered muscular vessel: Two Atria (left and right) Two Ventricles (left and right) Atrium: Filling chamber Pushes blood into ventricle Ventricle: Pressurization chamber Ejects blood into circulation Chambers separated by heart valves: One-way flow valves Four in total (tricuspid, pulmonary, mitral, aortic) Heart’s Anatomy Wikipedia. “Heart.” Wikipedia, p Retrieved from: Blood Flow in Heart:

Circulatory Pressures Yaddah (2006), View from the front [image]. Retrieved from

Clinical Use Measures –Rate and regularity of heartbeats –Size and position of the chambers –Presence of any damage to the heart –Effects of drugs

Specifications Input: Voltage (biopotential) Output : –Electronically (display) –Paper

Einthoven’s triangle Principles of Operation Kychot (2009), Einthoven Triangle [image]. Rwtrieved from

ECG Signal ECGpedia.org, “Basics.” Wikipedia. Retrieved from:

ECG Signal Openstax College. “The Cardiac Cycle, Fig ” From the publication: Biology. Rice University: 2013, pgs

ECG Signal P – atrial depolarization QRS complex – ventricular depolarization T – ventricular repolarization Anthony Atkelski (2007), Schematic diagram of a normal sinus rhythm [image]. Retrieved from

Signal of Heart Diseases Atrial Fibrillation Ventricular Fibrillation Michael Rosengarten BEng, MD.McGill [CC BY-SA 3.0 ( via Wikimedia Commons Jer5150 (Own work) [GFDL ( or CC BY-SA 3.0 ( via Wikimedia Commons

Sensor Disposable Ag/AgCl surface electrode Electrodes Malkin, Robert. Medical Instrumentation in the Developing World. Engineering World Health, 2006.

Electrodes Gel is important for a good contact with skin! TYPES: Disposable: $.05 to $.11 each Reusable Plate electrode

Diagnostic ECG Cooper, Justin and Alex Dahinten for EWH. “Electrocardiogram (ECG) Preventative Maintenance.” From the publication: Medical Equipment Troubleshooting Flowchart Handbook. Durham, NC: Engineering World Health, ECGpedia.org,.“ECG.Reference.Card.”.Wikipedia..Retrieved.from:.

Wave Forms Npatchett (2015), Derivation of the limb leads [image]. Retrieved from

Wave Forms Malkin, Robert. Medical Instrumentation in the Developing World. Engineering World Health, 2006.

Block Diagram for an analog ECG

Amplifier V OUT = (V 1 – V 2 )R 2 /R 1 Amplifies a difference. V OUT = A C (V 1 + V 2 ) + A D (V 1 – V 2 ) A D :differential (signal) gain, A C :common mode (noise) gain. The ratio A D /A C (Common Mode Rejection Ratio – CMRR) is a very important parameter. Ideally CMRR →∞

ECG amplifier (instrumentation amplifier) Input impedance >100 MΩ Range: 0.05–150 Hz Differential amplifiers with high gains (1000) CMMRs: 80 – 120 dB Amplifier

Differential Amplifier Arthur Ogawa (2014), Differential Amplifier with non-ideal on amp [image]. Retrieved from

Sampling The heartbeat rate itself is typically in the 60 to 200 beats per minute (1 Hz to 3.3 Hz) Range: 0.05–150 Hz 512 Hz sampling (2 ms) 10 samples at the QRS complex 12 bit resolution in analog-to-digital conversion ECGpedia.org,.“ECG.Reference.Card.”.Wikipedia..Retrieved.fro m:.

Sources of Interference AC interference: Cooper, Justin and Alex Dahinten for EWH. “Electrocardiogram (ECG) Preventative Maintenance.” From the publication: Medical Equipment Troubleshooting Flowchart Handbook. Durham, NC: Engineering World Health, Muscular interference

Commercial Examples PhillipN, (2007) Display device of a medical monitor as used in anesthesia [photograph]. Retrieved from (medical).jpg DiverDave (2010), Bispectral index monitor indicating a nearly isoelectric pattern of electroencephalographic activity [photograph]. Retrieved from _Monitor-Burst_Suppression.JPG

Commercial Examples Defibrillators also have a wave II ECG signal Pollo (2010), Biphasic defibrillator [photograph]. Retrieved from

Patient’s Safety Leak currents –Sometimes ECG may be used in direct contact with the heart –Even a small current running through the lead wires can cause death (ventricular fibrillation) Defibrillators display ECG leads I, II & III

Preventive Maintenance Calibration Clean reusable electrodes with alcohol and cloth physical checks-lead wires, Welch cups (if used), case damage, connectors, keypad/switches operation-paper speed, calibration pulse, trace/printout quality, front panel buttons and lights, battery life (if applicable) cleaning electrical patient safety

Weak or poor signal: –User error (may be no manual) –User error in position of electrodes –Loose wire –Dry disposable electrode –AC inference –Interference from other machines Common Problems

No signal: –No contact at Electrode (fallen off, no gel, broken wire) –Saturated Amp (gain too high) –Problem with cable connection –Damaged amplifier due to defibrillator Common Problems

User error –Manual lack or disregard –Complex user interface –Older models may require to adjust the gain for proper rate reading –Stylus position if applicable Common Problems

User error –Other electrode devices (ESU, bioimpedance) may interfere with each other –Wrong brightness settings – no display trace Common Problems

User error –Wrong electrodes positioning Symptom: Signal is saturated or distorted by power line noise Rules, electrodes should not be placed : 1 - On scar tissue 2 - Over a lot of body hair 3 - Closer than 2 inches from each other may Common Problems

Lead wires and main cord damage Lead interference Common Problems

AC interference –50 Hz/60 Hz: Check for a filter switch Common Problems

AC interference Line fluctuation Procedure: Test the machine in another room Connect the equipment to a voltage regulator Common Problems ligia diniz [CC BY 2.0 ( via Wikimedia Commons

Movement Artifact –Check to see if the patient is cold or nervous (muscle tremors interfere) –Patient or nurse touching any metal or wall Common Problems

Lack of disposable electrodes and gel –One can make cheap electrodes with sewing snaps and tape –Gel can be replaced by an ion free solution (Ex: salt water) or hand cream, shampoo, etc… Common Problems By Grkauls (Own work) [Public domain], via Wikimedia Commons

Paper feed problems No trace in the printer –Newer devices: clean the print head with alcohol gently with a fine soft clean cloth or Q-tip –Older devices (use alcohol to clean clotting in the ink tube) Common Problems

Test on yourself Check the heart rate alarms: –Lower than your own heart rate (upper rate alarm) –Higher than your own heart rate (lower rate alarm). Check battery (if present) charging circuit Test Procedures

Electrode lead leakage. (connect 1 KΩ resistor from electrode wire to ground, measure voltage (< 50 mV) in resistor and compute current (should be < 50 µA) Test Procedures 1 KΩ < 50 mV < 50 µA ECG Lead PhillipN, (2007) Display device of a medical monitor as used in anesthesia [photograph]. Retrieved from e:Monitor_(medical).jpg By Thiagoalmeidasa (Own work) [Public domain], via Wikimedia Commons David R. (Own work) [CC BY-SA 3.0 ( or GFDL ( via Wikimedia Commons

Troubleshooting Cooper, Justin and Alex Dahinten for EWH. “Electrocardiogram (ECG) Troubleshooting Flowchart.” From the publication: Medical Equipment Troubleshooting Flowchart Handbook. Durham, NC: Engineering World Health, 2013.