I add the analysts, etc. Mike Needham, Phil Cocks and Georgina Fradley 3M Healthcare Ltd., Loughborough, Leicestershire, UK Efficient drug delivery is.

Slides:



Advertisements
Similar presentations
Introduction A challenge of single kernel testing using an instrument such as the Perten Single Kernel Characterisation System (SKCS) is to relate the.
Advertisements

Introduction Acoustic radiation forces on particles within standing waves are used in processes such as particle separation, fractionation and agglomeration.
Cyclones A CENTRIFUGAL FORCE IN AIR SAMPLING
FLOW measurements.
Profile Analysis of Cascade Impactor Data: An Alternative View Andrew R Clark, Ph.D. Orally Inhaled and Nasal Drug Products Subcommittee of the Advisory.
Training Workshop on Pharmaceutical Development with a Focus on Paediatric Medicines / October |1 | Training Workshop on Pharmaceutical Development.
Methods of tablet manufacturing
5-9-B Cyclone Separators Cyclone separators are gas cleaning devices that  employ a centrifugal force generated by a spinning gas stream  to separate.
Copyright © 2005 Advantica Inc. (USA Only) and Advantica Ltd. (Outside USA). All rights reserved by the respective owner. Own Use Gas Review of Pre-heater.
Dispersion In Air of Micron and Nanometer Sized Particulate Systems: PREDICTING AGGLOMERATE STRENGTH N. Stevens H. El-Shall*, K. Powers*, A. Ranade**,
Novel Design of a Dry Powder Inhaler (DPI) for the Treatment of Acute Asthmatic Episodes University of Pittsburgh Senior Design – BioE 1160/1161 Annemarie.
SIX STROKE ENGINE. CONTENTS  Introduction  How six stroke engine works  Working principles  Specification of six stroke engine  Comparison of six.
2006 GSK Mathematical Modeling Symposium Modelling Particle Flow Dynamics Using Discrete Element Methods Mark Palmer, Valeriu Damian-Iordache, Pankaj DoshiRob.
Process Analytical Technologies Subcommittee Product and Process Development: An Industry Perspective David Rudd PhD Process Technology GlaxoSmithKline.
“Investigating the Effect of Nano-Silica on Recycled Aggregate Concrete” Colby Mire & Jordan Licciardi Advisor: Mohamed Zeidan ET 493.
SIX STROKE ENGINE.
Thermal Analysis and Design of Cooling Towers
Choking Pressure Ratio Guidelines for Small Critical Flow Venturis
Method conditions Excellent resolution and fast run times 2 x OligoPore, 4.6 x 250 mm columns gave excellent oligomeric resolution for the PS 580 sample.
SIZING PNEUMATIC SYSTEMS. Introduction Pneumatic systems are sized to meet output power requirements. The air distribution system is sized to carry the.
Introduction The traditional method for actuating microengineered structures using PZT has been to use bulk PZT bonded to the structure in question. Work.
A RAPID METHOD FOR ASSESSING REGIONAL LUNG DEPOSITION KN Chang (1), SH Huang (1), CP Chang (2), CW Chen (2), CC Chen (1) (1) Institute of Occupational.
Flow Measurement and Control. Orifice Meter The orifice meter consists of an accurately machined and drilled plate concentrically mounted between two.
Mosby items and derived items © 2008, 2002 by Mosby, Inc., an affiliate of Elsevier Inc. Chapter 3 Administration of Aerosolized Agents.
Aerosol Therapy and Nebulizers
Flow Measurement and Control
CALCULATIONS IN NANOTECHNOLOGY
Inhalation Devices Heba Abd El-fattah Sabry Pharm D.
Aerosols Dr. Aws Alshamsan Department of Pharmaceutics Office: AA87 Tel:
1 Subcommittee Report: Orally Inhaled and Nasal Drug Products (OINDP) Wallace P. Adams, Ph.D. OPS/CDER/FDA Advisory Committee for Pharmaceutical Science.
Port Fuel Injection VS. Direct Fuel Injection The Basics of DFI The main focus of DFI is to effectively and precisely control the fuel-to-air ratio. To.
Orally Inhaled and Nasal Drug Products Subcommittee Introduction and Objectives Eric B. Sheinin Deputy Director Office of Pharmaceutical Science Center.
Sarah D’Oyley – 3M Health Care Ltd, Loughborough Louisa Nelmes, Chris Blatchford – 3M Health Care Ltd, Loughborough (contact authors) The size of particles.
Jean Kelly 1, Steve Stein 1, Tom Robison 1, Zhaolin Wang 1, Allan Bohlke 1, John Simons 1, Jacqueline Ganser 1,Tucker Silberhorn 1, Randy Bay 2 ; 1 3M.
Stephen Stein 1, Dave Hodson 2, Todd Alband 1, Rich Sitz 1, Tom Robison 1, Zhaolin Wang 1, Herbert Chiou 1, John Simons 1, Rebecca McNally 1, and Jacqueline.
Andrew R Henry. 3M Drug Delivery Systems, Morley Street, Loughborough, Leicestershire. United Kingdom. The correlation chart illustrated the effect changing.
John Simons 1, Herbert Chiou 1, Louis Sigtermans 1, Tom Robison 1, Debra Wright 1, Jacqueline Ganser 1, Steve Stein 1, Les Harrision 1, Paul Ratner 2 1.
Andy Cooper and Chris Blatchford 3M Drug Delivery Systems Ltd, Loughborough, Leicestershire, LE11 1EP Text Here – Body copy will vary in size depending.
CIBSE HCNW 28 August 2014 Modular boilers. Traditional or low-tech replacement boiler installation; Multiple boilers eg 2 no 66% of load for security.
Comparing the Surface Energetics and Mechanical Properties of two Potential Sub-micron Sugar Bulking Excipients for use in Low-dose, Suspension Formulations.
P Bainbridge and P A Jinks 3M Drug Delivery Systems Loughborough Leicestershire LE11 1EP Text Here – Body copy will vary in size depending on how much.
Milling Is the reduction in the size mass by conversion of the large solid unit mass into smaller one by mechanical process. This needs energy.
1 A latent information function to extend domain attributes to improve the accuracy of small-data-set forecasting Reporter : Zhao-Wei Luo Che-Jung Chang,Der-Chiang.
1.Needham M., Cocks P. and Fradley G (2010), Investigating the Efficiency of the 3M Conix™ Reverse Cyclone Technology for DPI Drug Delivery, Respiratory.
3M Drug Delivery Systems 3 Chris Blatchford & Gemma Nixon, 3M Drug Delivery Systems, Morley St, Loughborough, UK. Graham Hargrave, Tim Justham & Edward.
3M Drug Delivery Systems 3 Introduction The headspace of pressurized metered dose inhaler (MDI) canisters is filled by the vapor of volatile components,
3M Drug Delivery Systems 3 Introduction A combination MDI product has been developed containing two active drug substances (designated as A and B) in solution,
KJ Hansen, JK Simons, TA Peterson 3M’s hMTS provides intradermal delivery of relatively high volumes of liquid API formulations. Infusion time may be anywhere.
Taper DPI FeatureImpact Efficacy Safety Compliance Cost High Efficiency  Equivalent lung dose achieved in- vitro with approximately 50% lower delivered.
Loss of Dose Patient Simulation Dan Clarke 3M Drug Delivery Systems Loughborough Leicestershire LE11 1EP Testing was performed using two suspension formulations.
Thomas Bell and Andy Cooper 3M Drug Delivery Systems Ltd, Loughborough, Leicestershire, LE11 1EP 3M Drug Delivery Systems Monitoring of Droplet Size Changes.
TYPES OF COMBUSTION CHAMBERS - CI Engines
OrbEEt Project Introduction <Location>, <Date> Presenter
CYCLONE SEPARATOR.
PNEUMATICS Chapter 5 Secondary Air Treatment
Author : Development and characterization of Budesonide pressurized metered dose inhaler (pMDI) using gamma scintigraphy Sharma.
Introduction Methodology Results Conclusion Reference
KJ Hansen, JK Simons, TA Peterson
Comparison of Pharmaceutical Performance
Enabling direct compaction at high drug loading via dry coating of APIs: Towards a predictive framework Presenter(s): Kuriakose T. Kunnath, NJIT Research.
Rahul Kumar Verma1, Hooman Yari and Lucila Garcia-Contreras1 
Aerosol Therapy & HFNC Natalie Napolitano, MPH, RRT-NPS, FAARC
Aerosol Drug Therapy Copyright © 2013, 2009, 2003, 1999, 1995, 1990, 1982, 1977, 1973, 1969 by Mosby, an imprint of Elsevier Inc.
Flow properties of pharmaceutical particles
Micrometrics. It is the science and technology of small particles. Knowledge and control of the size and the size range of particles are of significant.
AIR Quality Control Treatment of Emissions
RESULTS AND DISCUSSION
POWDER AND GRANULES FADHILAH FAIROZA FATIN HUSNA
The Aerosol Drug Management Improvement Team
The Aerosol Drug Management Improvement Team
Presentation transcript:

I add the analysts, etc. Mike Needham, Phil Cocks and Georgina Fradley 3M Healthcare Ltd., Loughborough, Leicestershire, UK Efficient drug delivery is essential due to the rising cost and increasing potency of active pharmaceutical ingredients (APIs). The 3M Conix™ reverse-cyclone dry powder inhaler (DPI) technology provides one potential way to achieve high efficiency delivery to the lung. This paper will seek to demonstrate, through in-vitro impactor testing, that the Conix™ technology preferentially releases respirable particles from the reverse cyclone vortex system thus reducing pre-separator and throat deposition when compared to a leading commercial DPI device. The robustness of this performance to fill weight, pressure drop and flow volume will also be demonstrated. It will be shown that this is achieved using the same commercial API/lactose blended formulation and a simple passive system that is readily incorporated into single and multiple use devices. 3M Drug Delivery Systems Investigating the Efficiency of the 3M Conix™ Reverse Cyclone Technology for DPI Drug Delivery Pharmaceutical Performance Theory of Cyclone Delivery References Introduction Acknowledgements. Conclusions Most dry powder inhaler devices utilize a blend of micronized active pharmaceutical ingredient and coarse carrier particles (usually lactose) to bulk out the formulation, thus making the metering and delivery of the API more reproducible. DPI devices are designed to separate the two types of particles through application of shear forces or induction of particle/particle & particle/surface impaction. These techniques generally result in separation, as the formulation leaves the device and the larger carrier particles subsequently impact on the patient’s throat, whilst the smaller API particles are delivered to the lung. The design intent of the 3M Conix™ DPI system was to approach the deagglomeration process in a different way. The aim of the Conix™ technology is to preferentially release small (API) particles that are potentially respirable whilst retaining larger lactose particles and lactose / drug clusters so that they can continue to be worked on and deagglomerated further. Thus the emitted dose would be reduced whilst the fine particle fraction would be high compared to a more traditional approach. The high efficiency of the 3M Conix™ DPI has been demonstrated through assessment of fine particle distribution compared to a marketed albuterol sulfate DPI product. The albuterol sulfate blend was harvested from a commercial DPI (GSK’s Accuhaler™, 200 mcg albuterol per dose, blister fill = approx. 240mcg, nominal emitted dose = 200mcg per dose, 12.5mg per blister) product and filled into Conix™ blisters (10 mg per blister), total blister content = approx. 160mg, emitted dose = 100mcg). Testing was performed using test pieces of a recently developed version of the Conix™ cyclone ‘engine.’ These test pieces were made from injection moulded polypropylene cyclones and rapid prototype (stereo lithographic) air inlet & mouthpiece components which were bolted together. The Conix™ engine represented in these test pieces could readily be incorporated into any one of the Conix™ device family. The particle size distribution in Figure 2 illustrates the significant difference between the particle size distribution profiles of Conix™ and that of Accuhaler™. The Conix™ device emits significantly fewer large particles and more particles of a potentially respirable size. This supports the theory that the larger particles are retained and re-entrained into the deagglomeration process. This is of benefit, not only as it potentially increases the respirable dose delivered, but also the reduction of deposition on the throat and pre- separator is likely to reduce systemic absorption and may improve patient acceptability through reduced lactose inhalation and systemic API uptake. The 3M Conix™ technology has been designed to address the challenge of deagglomeration in a different manner to most other DPI devices currently available. The initial studies performed here have demonstrated that the original design intent of holding on to large, non-respirable, particles and clusters, so that they can be worked on further, to improve the emitted respirable mass whilst reducing the output of larger particles, has been achieved. The Conix™ technology brings high efficiency API delivery to the passive DPI development arena using tradition ‘simple’ API / lactose blended formulations. This increased efficiency is achieved through a novel process which both deagglomerates the formulation in an effective manner but also preferentially retains particles that are still agglomerated such that they can continue to be ‘worked upon’ until the drug particles are released and are suitable for delivery to the lung. Thus, Conix™ technology should improve delivery to the lung as indicated by increased efficiency, and reduced throat and pre-separator deposition. This is achieved from a fundamentally simple device which is expected to have a competitive cost to produce. The absolute of performance of >50% efficiency across a range of fill masses is also impressive, especially for such an intrinsically simple device. This high efficiency of the Conix™ device brings potential benefit to those wanting to deliver high cost compounds where waste needs to be minimised, and also to those delivering highly potent agents where delivery to the lung needs to be maximised whilst limiting systemic delivery. 3M offers a full range of feasibility, development and manufacturing capabilities combined with regulatory guidance to help bring products to market. Broader 3M corporate technologies further offer the ability to leverage expertise in materials and particle engineering as well as process development. For more information, visit our website at 3M.com/dds 1.Nichols, S. and Wynn, E., (2008) “New Approaches to optimizing dispersion in dry powder inhaler – dispersion force mapping and adhesion measurements,” Respiratory Drug Delivery 2008, Dalby, R.N, et al. (eds), DHI Publishing, River Grove IL, pp The vortex produced by the reverse flow cyclone creates relatively high velocities (and therefore energy) in the air flow which imparts the energy required for deagglomeration through collisions with the cone wall, other particles and through particle shear. Previous work has shown that impaction events are more effective at deagglomerating than airflow shear alone (1). Figure 1 – The reverse flow cyclone principle Figure 3 shows increased fine particle fraction (percent of particles less than 5 microns) for Conix™ compared with the Accuhaler™ DPI. Device efficiency is calculated as the fine particle mass as a percentage of total blister content. This increase in respirable particles and reduction in the number of large non-inspirable particles is also demonstrated through mass mean aerodynamic diameter (MMAD); Conix™ mean MMAD = 0.97μm, half that from the Accuhaler™ DPI which had an MMAD of 1.99μm. Figure 2 – Fine Particle Distribution for albuterol sulfate DPIs Figure 3 – Pharmaceutical performance summary for albuterol sulfate DPIs In Conix™, deagglomeration and aerosolization of the API occurs through reverse flow cyclone technology (Figure 1). Upon inspiration, a flow of air enters the cone and forms a free vortex. In traditional methods of cyclone separation, such as separation of sawdust from air in saw mills, the bottom of the cone is open and particles suspended in the vortex exit to a collection hopper and the cleaned air exits separately. However, in Conix™ the base of the cone is blocked such that when the vortex hits the bottom the flow reverses and is forced through the centre of the incoming air towards the exit orifice. This is known as a forced vortex. The performance of the Conix™ technology also needs to be robust across a range of fill masses to enable different strengths of a single product to be produced in a simple manner without the need for re-formulation of each variant. This was demonstrated using fill masses of 5 mg, 10 mg and 15 mg with harvested albuterol formulation (GSK’s Accuhaler™) and evaluating the in-vitro performance using Andersen Cascade Impaction (ACI) at 4kPa for 4L. The data, presented in Figure 4, show consistent emitted dose, fine particle mass and lactose retention across the range of fill masses investigated. The impact of pressure drop and flow sensitivity were also assessed using a 5 mg fill mass and harvested albuterol formulation (GSK’s Accuhaler™). The performance of the system was again assessed by ACI, this time run at 4kPa / 4L, 4kPa / 2L and 2kPa / 2L. These data (Figure 5) show good robustness to changes in pressure drop and flow volume with some indication of a slight decline in performance as the pressure drop and flow volume are reduced. The data from the 2kPa / 2L study were also more variable based on these small data sets. The authors thank Karen Hunt, Dave Hodson, Rob Miller, Ashish Dasani, Rich Sitz, Adam Stuart, Andrew Henry, Steve Stein, Susy Halling, Paul Bainbridge, Alex Slowey, Emma Ross, Paul McCreath, Scott Parker, Chi-Tung Li, Matt Potts, Matt Kelly, Anthony Hayes, Sarah Dexter, Cambridge Consultants Ltd and David Harris for their contributions to the development of the 3M Conix™ DPI technology. Figure 4 – In-vitro performance for albuterol sulfate formulation across a range of fill masses Figure 5 – In-vitro performance for albuterol sulfate formulation at different pressure drops and flow volumes As deagglomeration occurs, the large lactose particles are flung to the sides of the cone and the lighter API particles are carried along by the air flow and exit the cyclone. Therefore, any API still adhered to lactose particles are re-entrained into the deagglomeration process rather than being emitted, typically to impact in the throat. Error bars are max / min throughout