1 PCE 4.4 New Development In DC Containment Steve Howell.

Slides:



Advertisements
Similar presentations
SAN DIEGO SUPERCOMPUTER CENTER at the UNIVERSITY OF CALIFORNIA, SAN DIEGO Green Datacenter Initiatives at SDSC Matt Campbell SDSC Data Center Services.
Advertisements

Optimizing High Density Cooling Solutions for Data Centers
Clair Christofersen Mentor – Aaron Andersen August 2, 2012
Session Title: Demystifying Efficiency in the Data Center Utilizing Airflow as a System Presented By: Jon deRidder Enabled Energy.
1 Using CFD as a Guide When Making Changes to the Data Centre. Nagy Daniel Senior IT Manager Magyar Telekom Technical Unit, IT Operations Directorate.
Matt Warner Future Facilities Proactive Airflow Management in Data Centre Operation - using CFD simulation to improve resilience, energy efficiency and.
Hot Aisle vs. Cold Aisle Containment
1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – July 2012eere.energy.gov Building Science Basics WEATHERIZATION INSTALLER/TECHNICAN FUNDAMENTALS.
Columbia University’s Advanced Concepts Data Center Pilot June 17, 2011.
Smart Devices. Smart Buildings. Smart Business The Potential for DCx Technology Enabled HVAC Operation Scot Duncan, P.E.
Zycko’s data centre proposition The very best products and technologies Focus on what your customers need Turning products into solutions Wide range of.
Cooling Product Positioning
PG&E and Altera Data Center Energy Efficiency Project.
VIACOM Data Center Optimization Project
Anand Vanchi- Intel IT Ravi Giri – Intel IT Sujith Kannan – Intel Corporate Services Comprehensive Energy Efficiency of Data Centers – Case study shared.
02/24/09 Green Data Center project Alan Crosswell.
Standardized Curriculum WAP Training Plans and Resources.
Effect of Rack Server Population on Temperatures in Data Centers CEETHERM Data Center Laboratory G.W. Woodruff School of Mechanical Engineering Georgia.
Thermal Management Solutions from APW President Systems
 Site  Requirements  Local Resources  Initial layout ideas  Brief material selection  Supply options.
September 18, 2009 Critical Facilities Round Table 1 Introducing the Heat Wheel to the Data Center Robert (Dr. Bob) Sullivan, Ph.D. Data Center Infrastructure.
Steve Craker K-12 Team Lead Geoff Overland IT and Data Center Focus on Energy Increase IT Budgets with Energy Efficiency.
1Taylor Engineering, LLC HVAC System Design Mark Hydeman, P.E., FASHRAE Taylor Engineering, LLC
Current trends in data centre outsourcing
Saving up to 60% of Energy With The Precision Cooling SmartAisle ™ Configuration.
Best Practices in HVAC Design/Retrofit
Accelerating Your Success™ 1 Green IT April 22, 2009.
Overview of Liquid Cooling Systems Peter Rumsey, Rumsey Engineers.
Applying Precision Air Conditioning Systems
Optimising Data Centre Power Planning and Managing Change in Data Centres - 28th November Cirencester.
Air Conditioning and Computer Centre Power Efficiency The Reality Christophe Martel Tony Cass.
Designing the Building of the Future Practical Experience in IT Deployment Collaborate to Accelerate.
Data centre air management Case studies Sophia Flucker.
Energy Usage in Cloud Part2 Salih Safa BACANLI. Cooling Virtualization Energy Proportional System Conclusion.
Smartcool Systems Inc. Providing effective and reliable energy efficiency solutions for HVAC-R customers around the globe.
Infrastructure Gina Dickson – Product Manager Kevin Jackson – Sales Manager.
Thermal Design Project Final Report John Wallerich Principal Engineer Wallerich Group, LLC.
Dealing with Hotspots in Datacenters Caused by High-Density Computing Peter Hannaford Director of Business Development EMEA.
Architectural Engineering Senior Thesis Mechanical System Redesign Saint Joseph Medical Center Chris Nicolais.
Schneider Electric: Total Cooling Solutions for Data Centers
High Performance Computing (HPC) Data Center Proposal Imran Latif, Facility Project Manager Scientific & Enterprise Computing Data Centers at BNL 10/14/2015.
We can…. 2 GLOBAL REFERENCES Rev: 00 References :
Containment Solutions. Cooling Efficiency Solutions Passive Thermal Containment Blanking Panels Foam, Skirts and Covers Raised Floor Grommets Brush Seal.
Energy Savings in CERN’s Main Data Centre
All content in this presentation is protected – © 2008 American Power Conversion Corporation Row Cooling.
1 ITM 4.1: A Three-Step Approach to Better Instrumentation of the Data Center and Use of KPIs in Decision Making George Clement.
Date of download: 5/27/2016 Copyright © ASME. All rights reserved. From: Experimentally Validated Computational Fluid Dynamics Model for a Data Center.
Hot /Cold Aisle Containment  Traditional Data Center/Telco designs are changing significantly!
1 ITM 1.2 How IT Decisions Impact Data Center Facilities: The Importance of Collaboration Lars Strong P.E. Upsite Technologies, Inc.
1 PCE 2.1: The Co-Relationship of Containment and CFDs Gordon Johnson Senior CFD Manager at Subzero Engineering CDCDP (Certified Data Center Design Professional)
1 EIT 2.2 Is your company missing out on the cost-savings opportunities offered by data center consolidations? Andy Abbas Co-Founder and Vice President.
Ventilation & Airflow NetShelter CX 18U,24U,38U Ambient office air is drawn in to the soundproofed air-intake chambers on either side of the NetShelter.
Restricted © Siemens AG 2016 Page 1 Tower to Rack: Driving the Next Generation of Cooling Optimization Technology Jay Hendrix, Siemens Industry Inc. Aaron.
Monitoreo y Administración de Infraestructura Fisica (DCIM). StruxureWare for Data Centers 2.0 Arturo Maqueo Business Development Data Centers LAM.
1 DB 3.1 The Life Cycle of a Data Center Steven Shapiro PE, ATD Morrison Hershfield Mission Critical Company Logo OK.
[Eco 2 System] A Fundamental Twist To Data Centre Cooling Ecological Friendly & Economical.
West Cambridge Data Centre Ian Tasker Information Services.
1 Copyright © 2016, The Green Grid The webcast will begin shortly Today’s live session will be recorded.
CANOVATE MOBILE (CONTAINER) DATA CENTER SOLUTIONS
Containment Solutions
Lars Strong P.E. Upsite Technologies, Inc.
Unit 2: Chapter 2 Cooling.
Green IT Focus: Server Virtualization
Using Heat to Increase Cooling George Hannah BEng (Hons) CEng MIMechE
Date of download: 11/2/2017 Copyright © ASME. All rights reserved.
Grunenwald Science and Technology Building
Closing the Gap to Free Cooling in the Data Center
Technician’s Guide and Workbook for Zoning Section 1: Introduction
Liebert DSE High efficiency thermal management
OCP Engineering Workshop Hosted by Flex
Presentation transcript:

1 PCE 4.4 New Development In DC Containment Steve Howell

2 Data Center World – Certified Vendor Neutral Each presenter is required to certify that their presentation will be vendor-neutral. As an attendee you have a right to enforce this policy of having no sales pitch within a session by alerting the speaker if you feel the session is not being presented in a vendor neutral fashion. If the issue continues to be a problem, please alert Data Center World staff after the session is complete.

3 New Development In DC Containment Overview: o Current Data Center Challenges/Initiatives Cooling Efficiency in the White Space  (consolidation/expansion) Rise in energy costs Driving down operational costs Maximizing PUE o Existing Containment Best Practice Containment Systems Benefits of Containment Reduction in cooling capacity IT equipment savings

4 New Development In DC Containment Overview: o Challenges with Containment Dynamic DC environments  Footprint expansion  Aisle consolidation  Server virtualization Updated NFPA regulations User Environment  Traffic  Plug & Play o Virtual Containment Development Development Identifying the need Industry transformation Existing DC Manager containment challenges Science & Engineering

5 New Development In DC Containment Overview: o Implementation Case Study #1 Project Scope  Retrofit Thermal Results Annual Savings Simple Payback o Case Study #2 Project Scope  New Technology Thermal Results Annual Savings Simple Payback

6 New Development In DC Containment Overview: o Future of the Technology Top Down applications New Build architecture Server closets 2016 projected deployments

7 New Development In DC Containment Data Center Industry Challenges: Globally, Data Center energy costs continue to rise at an exponential rate. On average, the cost of energy accounts for 25% of the total operating costs inside the Data Center. In some areas of the United States, kWh costs have risen over 30% between 2012 and With a rate of change that high within 3 years, energy efficiency will continue to be a high priority in the Commercial & Industrial space. As clients continue to virtualize on new servers, move to co-lo facilities & even expand within their existing Data Centers, airflow management will continue to be an area of concern in such dynamic environments.

8 New Development In DC Containment Data Center Industry Initiatives: o Maximize PUE (Power Usage Effectiveness)  Direct relationship with cooling during DC space transformation  Reducing chilled water usage  Cooling maximization with increased/decreased server heat production  Decommissioning of Legacy equipment  New technology integration

9 New Development In DC Containment Data Center Industry Initiatives: o Maintain ASHRAE Standard  Reach optimum inlet temperature while reducing costs  Directing the cooling capacity to the server face (Containment)  Improved Delta T  Controlled heat rejection & return air temperatures  Proper CFM delivery per rack kw requirement

10 New Development In DC Containment Current Containment Practice: o Ceiling Mount o Overhead softshell/ rigid panels o End Aisle curtain/ rigid doors o Slide or clip-on panel installation o Hot/Cold Application o NFPA non compliant Figure 1: Thermal Soft Shell Containment

11 New Development In DC Containment Current Containment Practice: o Top of Cabinet Mount o Heat Shrink/Mechanical Drop away panels o End Aisle curtain/ rigid doors o Hot/Cold Application o NFPA compliant Figure 2: Panel Rigid Containment Benefits: Improved rack cooling capacity index Elimination of Hot Spots Energy savings at server fan level Energy savings associated with less cooling

12 New Development In DC Containment Industry Challenges with Containment: o NFPA Regulations o Retrofit containment solutions with Legacy fire suppression o Structural costs associated with new fire suppression/smoke detection o Dynamic infrastructure environment

13 New Development In DC Containment Industry Challenges with Containment: o Managing IT equipment growth Aisle Expansion/Consolidation Installation of new cable trays o Equipment decommissioning/re-location Server re-location & new stack buildouts Removal of racks causing voids in containment

14 New Development In DC Containment Industry Challenges with Containment: Figure 3: Rack removal with physical containment 3 existing racks were decommissioned & moved, leaving voids in the physical containment causing hot air recirculation.

15 New Development In DC Containment Developmental Initiatives: o Solution that meets all NFPA regulations o Dynamic, structure-less solution that can fit/evolve seamlessly within any raised floor DC. o Elimination of physical walls for high traffic DC environments. o Scientific approach utilizing turbulent flow technology which requires less cool air distribution. o Elimination of high cost associated with new/retrofitted architectural changes. Fire Suppression Wall replacement/Curtain modifications

16 New Development In DC Containment New Containment Development: o Understand 90% of existing Data Center’s still sit on a raised floor, the goal was to first develop a solution that could integrate seamlessly into the raised floor space. o The development began in QTR. 1 of 2014, after the revised NFPA 75 & 76 standards were released which states the risks and regulations against fusible links & heat-shrink panels found in modern containment solutions. o Acknowledging the physical limitations of existing Data Centers such as inconsistent rack dimensions, floor space & legacy equipment, the goal was to design a much more “transparent” solution, that could achieve similar or greater results to Physical Containment, but on a much more dynamic level.

17 New Development In DC Containment New Containment Development: o New Containment practices utilize a combination of static pressure balancing & turbulent air flow technology, which cuts through the thermal layers and provides directional cold air delivery further up the face of equipment racks, directly impacting the face of the servers. o Structure-less systems are based on science & intellectual properties which eliminates the need to build a room within a room, and evolve within the data center space as the Data Center space continues to change. Figure 4: Structure-less Containment

18 New Development In DC Containment Science in Technology: Laminar Flow o Existing Raised floor cooling systems/tiles utilize standard Laminar Flow vented tiles. o Laminar Flow naturally has a lower stratification due to the inability to break through heat barriers. o Existing Raised floor systems rely on the principal of greater static pressure=greater CFM delivery through the tile. o Increasing the CFM “throw” inside containment simply enhances wasted cooling. Figure 5: Airflow path comparison chart

19 New Development In DC Containment Science in Technology: Turbulent Flow Figure 5: Airflow path comparison chart o Utilizing Turbulent Flow technology in the data center helps maximize the AUE (Airflow Utilization Efficiency) in breaking down the thermal heat layers much more effectively. o Turbulent flow produces air streams in 360 degrees, which allows the servers to pull airflow throw the device with 50% less force at the fan level. o In addition to standard containment results, By improving the AUE, studies have shown you can decrease the usable cooling by 20%.

20 New Development In DC Containment Case Study #1 Overview: o 1,500 Sq. Ft. Raised Floor o 18” Plenum Depth o (2) 20 Ton DX Down-flow CRAC units o 34 kW IT Load Client Initiatives: o Eliminate Critical Rack Temperatures o Reduce Costs Associated with Cooling & IT o Become N+1 redundant Deployment: o Samurai Containment™

21 New Development In DC Containment Case Study #1 Model: Current Conditions Installation Results X Figure 6: Physical containment with 9 tiles in cold aisle. Figure 7: Structure-less containment with 1 unit cycled off, drop in inlet temperature and 7 tiles in cold aisle.

22 New Development In DC Containment Case Study #1 Results: Current Future (1 unit off) Vented Tile Production (CFM) 20,92811,952 Inlet Temperature Avg. (°F) Static Pressure (wg) Annual Cooling Reduction Savings:$17, Annual IT Consumption Savings:$1, Simple Payback:14 Months

23 New Development In DC Containment Case Study #2 Overview: o 10,250 Sq. Ft. Raised Floor o 24” Plenum Depth o (9) 30 Ton CW Down-flow CRAH units Client Initiatives: o Eliminate Rigid Containment due to dynamics/shifting of equipment inside DC o Reduce Costs Associated with Chilled Water cooling o Eliminate hot spots in critical areas Deployment: o Samurai Containment™

24 New Development In DC Containment Case Study #2 Model: Current Conditions Figure 8: Physical containment deployed with gaps & voids inside rows due to dynamic changes inside the DC environment. Significant hot spots inside cold aisle. Figure 9: Structure-less containment with elimination of all critical hot spots inside cold aisle. Installation Results

25 New Development In DC Containment Case Study #1 Results: Current Future Vented Tile Production (CFM) 170,478181,440 Inlet Temperature Avg. (°F) Static Pressure (wg) Annual Chilled Water Savings:$36, Annual IT Consumption Savings:$6, Simple Payback:20 Months

26 New Development In DC Containment Future of the Technology: o Development of ceiling plenum solution utilizing turbulent flow technology. Suitable environments to include all top down applications:  New Build Slab Infrastructure  Existing Ceiling plenum HVAC  Office space retrofit  Server Closet new build  Server Closet retrofit  Release 1.0 expected Q3 2016

27 New Development In DC Containment Future of the Technology: o Based on fire code compliancy, expected to become new Data Center standard by o 72 implementation deployments expected in o Integrated step in all “new build” data center designs.

28 New Development In DC Containment Summary: o Existing Data Center containment practices: Efficiency gains to be had through proper cold/hot air separation. Some applications do not meet new NFPA standard. As Data Centers become much more dynamic, the difficulty in maintaining the integrity of physical containment is an uprising issue.

29 New Development In DC Containment Summary: o New Structure-less containment practices: Efficiency gains while meeting NFPA requirements. Ability to evolve and change with the up-rise in dynamic data center environments. Integrating science with existing best practices allows for much more efficiency & eco-friendly cooling. Less overhead cost associated with architectural work needed for existing containment practices.

30 3 Key Things You Have Learned During this Session 1. Existing Industry Practices 2. New Containment Practices 3. Future of the Technology

31 Thank you Steve Howell, CEO Technology Connection, LLC