ELECTRICAL INSTALLATION IN BUILDING

Slides:



Advertisements
Similar presentations
L.T Circuit Breakers.
Advertisements

Electrical Installation
Basic electrical circuitry & applications
CIRCUIT ARRANGEMENT (Note: All the mentioned tables in this course refer to, unless otherwise specified, Low Voltage Electrical Installation Handbook,
Chapter : 7 : Mains Electricity
Chapter 2 ELECTRICAL POWER SUPPLY AND DISTRIBUTION IN BUILDINGS
EET Survey of Electronics
Electrical Power Systems
Circuit Protection Electrical circuits require protection to prevent fire or electrocution in the event of a fault. There are two main types of circuit.
USING ELECTRICITY – Class 7 HEATING EFFECTS OF ELECTRICITY Done by Mrs. Aparna.S.
The Home Inspection Book: A Guide for Professionals By Marcia Darvin Spada Copyright, Thomson/South-Western, 2003, Revised, 2006.
By Carlin Bright. Electricity The flow of electrons in a conductor.
Engineering Practice Electric Fitting Resistance Electrical resistance is the ratio of voltage drop across a resistor to current flow through the resistor.
Area of Study 2: Electricity
Vidhyadeep Institute Of Management & Technology, Anita, Kim Electronics & Communication Department Guided by Mr. Vicky Paperwala.
COMMERCIAL ELECTRICAL (Chapter 11)
Electricity © PDST Home Economics. TASK!!!! Make a list of all electrical appliances you have in your home.
1 HVACR116 – Trade Skills Plumbing, HVAC, Electrical Overview.
Practical Electricity
Practical Electricity. Recap…  5 important formulae: Q = Charge (Coulomb) I = Current (Ampere) t = time (second) V = Voltage or potential.
NGfL CYMRU GCaD ELECTRICAL WORKS DISCLAIMER Neither WJEC or NGfL accepts any responsibility whatsoever for any injury, however caused,
35 Electric Circuits In a parallel circuit, each device operates independent of the other devices. A break in any one path does not interrupt the flow.
The 13 Amp PLUG Fuse Insulating Casing Live Wire Neutral Cable grip Flexible Copper conductors Earth.
Consumer’s Main Switchroom & Main L.V. Switchboard
SERVICE ENTRANCE EQUIPMENT
A SEMINAR ON 400 KV GSS(RRVPNL) BIKANER.
Testing of Low Voltage Installations
19.2 Domestic electricity Paying for electrical energy  Most of the electrical appliances in your home use mains electricity.  Mains electricity: alternating.
DOMESTIC ELECTRICAL CIRCUITS National Diploma Mechanical and Electrical Services Construction.
Electrical Circuits Chapter 20 Section Three. Science Journal Entry #42 Expound upon Ohm’s Law and its relationship to current, resistance, and voltage.
Timing (minutes) Learning ObjectiveMain tasks / ProcessResources / tools 5TitleStandard Operating Procedures for Power Press Machine Slide 1 5Index 
Switches and Over Current Protective Devices Class Instructor ALPHER E. DE VERA, uap.
Residential Wiring Unit 3 – Installation and Planning.
ELECTRICAL WIRING WIRING BASICS Written by Bobby Joslin
Electricity. TYPES OF CIRCUITS Individual electrical circuits normally combine one or more resistance or load devices. The design of the automotive electrical.
ELECTRICAL INSTRUMENTS ( service and utilization )
Chapter 3 PHYSICAL INJURY AND CONTROLS 3.2 Electrical Safety
Domestic Circuits – Learning Outcomes
SYNERGY INSTITUTE OF ENGINEERING AND TECHNOLOGY
Residential Wiring Unit 3 – Installation and Planning Chaps 9-12.
Electrical Circuits Section 7.3. Electrical Circuits Circuits rely on generators at power plants to produce a voltage difference across the outlet, causing.
4.0 DOMESTIC ELECTRICITY Domestic electricity is that electricity which is supplied to homes under specific conditions of current and voltage. Voltage,
Current.
Sub Station.
PROTECTION AGAINST INDIRECT CONTACT
Circuits Electrical Wiring.
Electrical Gas Plumbing Heating & Cooling
5.3 : BUILDING ELECTRICAL SUPPLY
Effects of an Electric Current and Domestic Circuits
ELECTRICAL INSTALLATION AND MAINTENANCE (EIM) 5 INSTALL ELECTRICAL PROTECTIVE DEVICES FOR DISTRIBUTION, POWER, LIGHTING, AUXILIARY, LIGHTNING PROTECTION.
Series and Parallel Circuits
ESTIMATING AND COSTING OF DOMESTIC INSTALLATION
Practical electricity
Engineering Project Cable Management.
ELECTRICAL POWER-II Electrical engineering sixth semester
SERIES AND PARALLEL CIRCUITS
Domestic Electricity AIM: To understand the use of domestic electricity and safety features such as fuses, circuit breakers and the earth circuit
EET 323 – Electrical System Design Lecture 9: Grounding
The Safe Use of Electricity
Conductor A material, such as copper, that permits the flow of electricity; usually refers to the a wire.
A. Touching both terminals with the hands can cause electrical shock
Objectives Learn about Electricity Pricing Electric systems.
Objectives Review conductor and conduit selection
Objectives Finish Transformers Introduce HW5 (Pricing)
Electrical components and systems
Presentation transcript:

ELECTRICAL INSTALLATION IN BUILDING Elements of Electrical Design (2150904) ELECTRICAL INSTALLATION IN BUILDING PRESENTATION BY:- Guided By:- RONAK ANTALA 130240109002 Prof. RAJ PATEL PRAGNESH CHOVATIYA 130240109010 Prof. JIGAR THAKKAR JANAK DESAI 130240109011 JENIL DHOLAKIYA 130240109013 JAIMIN MATHUKIYA 130240109042 HASMUKH GOSWAMI COLLEGE OF ENGINEERING

Contents Domestic Electrical Installations Electricity Board Intake POWER CIRCUITS Electrical Building Protection Distribution in High Rise Buildings Types of Light Fitting Lighting Design

DOMESTIC ELECTRICAL INSTALLATIONS Most domestic premises receive a single-phase supply of electricity from an area electricity board at a rating of 240 volts and frequency of 50 hertz. The area electricity board's cable, from which the domestic supply is taken, consists of four lines, three lines each carrying a 240 volt supply and the fourth is the common return line or neutral

Neutral is connected to earth at the transformer or substation as a safety precaution should a fault occur on the electrical appliance. Each line or phase is tapped in turn together with the neutral to provide the single-phase 240 V supply

ELECTRICITY BOARD INTAKE The supply or intake cable may enter building in two ways Underground duct  Overhead supply. An underground supply is preferred since all of the electrical service is hidden.

From the sealing chamber the supply passes through the meter, which records the electricity consumed in units of kilowatt/hours, to the consumer unit which has a switch controlling the supply to the circuit breakers or circuit fuses These fuses are a protection against excess current or overload, the fuse or circuit breaker will isolate the circuit from the source of the problem.

The consumer unit should be fitted close to the point of service entry and from here the service is divided into a number of sub-circuits. It is normal in a domestic installation to separate power circuits and lighting circuits so that if a fault occurs then not all socket outlets or lights are isolated.

Sometimes an external cabinet is used for easy meter reading Sometimes an external cabinet is used for easy meter reading. This is located in an outside wall as shown below. EXTERNAL CABINET

POWER CIRCUITS When deciding on the number of circuits for a house, a useful rule is; one power circuit for every 100m2 of floor area. In larger houses this means that two circuits can be used for power socket outlets,  in a two-storey house this would be one circuit for upstairs and one for downstairs. In some larger houses a separate power circuit is also installed for the garage / utility area

In all domestic installations a separate power circuit is required for the cooker since the electrical demand is likely to be high. The immersion heater in the hot water cylinder can also be supplied from a separate circuit since a 3kW load is quite high. Ring circuits are used as a safe and economic method of distribution of electricity to socket outlets. Many consumer unit manufacturers produce 8 way and 12 way units.

Electrical Building Protection Protection against electric shock is provided by insulating and placing live parts out of reach in suitable enclosures, earthing and bonding metal work and providing fuses or circuit breakers. A fuse or miniature circuit breaker (MCB) will disconnect the supply automatically before the overload current can cause a rise in temperature which would damage the installation.

An isolator is a mechanical device, which is opened manually and is provided so that the whole of the installation, one circuit or one piece of equipment may be cut off from the live supply. In addition, a means of switching off for maintenance or emergency switching must also be provided. In practice it is the aim to bring the Electrical supply to the appliance with as small a loss of voltage through the conductor as possible. This means that the wiring must have the smallest resistance that is economical

Distribution in High Rise Buildings The electrical distribution system in high rise flats and office buildings uses a bus bar system. A bus bar is a solid copper bar that carries the electrical current. The bus bars run vertically inside trunking and are supported by insulated bars across the trunking chamber. The electrical supply to each floor is connected to the rising main by means of tap- off units.

To balance electrical distribution across the phases, connections at each floor should be spread between the phase bars. To prevent the spread of fire and smoke, fire barriers are incorporated with the busbar chamber at each compartment floor level. The chamber must also be fire stopped to the full depth of the floor.

Types of Light Fitting The types of light fitting that we use in modern buildings can be divided into five sections. 1.    Decorative lighting   2.    Commercial lighting 3.    Industrial lighting 4.    Outdoor lighting 5.    Emergency lighting

Lighting Design Quantity of light The amount of light emitted from a light fitting is given in lumens (lm). A lumen is the unit of luminous flux. The amount of light falling on a surface is measured in lux. One lux is equal to 1 lumen per square metre …….. 1 lux  =  1 lm/m2.

Illuminance (lux) Activity Area 100 Casual seeing Corridors, changing rooms, stores 150 Some perception of detail Loading bays, switch rooms, plant rooms 200 Continuously occupied Foyers, entrance halls, dining rooms 300 Visual tasks moderately easy Libraries, sports halls, lecture theatres. 500 Visual tasks moderately difficult General offices, kitchens, laboratories, retail shops. 750 Visual tasks difficult Drawing offices, meat inspection, chain stores. 1000 Visual tasks very difficult General inspection, electronic assembly, paintwork, supermarkets. 1500 Visual tasks extremely difficult Fine work and inspection, precision assembly. 2000 Visual tasks exceptionally difficult Assembly of minute items, finished fabric inspection.