Characteristics of protection factor leakage based on induced failure mechanisms Lauren Drumm Mentored by Steve Yurechko Gas masks are used for protection.

Slides:



Advertisements
Similar presentations
Tool Mark Analysis Mrs. Ashley.
Advertisements

Digital Current Transformer Reporter
Respiratory Protection Program (RPP) San Joaquin Delta College Revised: 10/05/2011.
The purpose of this template is to allow the Subject Matter Expert (SME) to create on online training module in a familiar platform in Microsoft PowerPoint.
EXPERIMENTAL DESIGN STATEMENT OF PROBLEM Not a yes or no answered question Problem should be clearly testable and specific to your investigation.
Unit 7.2. Respirator fit testing TB Infection Control Training for Managers at National and Subnational Level.
Students will implement a simple experiment to learn about testing variables while furthering their knowledge of pulmonary health.
 Description of PressurePro System  Identify system components  Display and Operational Modes  Sensor alerts  Checking of tire pressures  Manual.
Two-mode Safety and Battery System Service
Implement Mission-Oriented Protective Posture (MOPP) Task: Skill Level 2 REFERENCE: STP SMCT.
Design of icons for use by Chinese in Mainland China Interacting with computers 9(1998) Yee-Yin Choong, Gavriel Salvendy Report: Yang Kun, Ou.
Writing a Research Paper
Lecture 6 Report Structure
Experimental Design Fr. Clinic II Dr. J. W. Everett.
OHD Quantifit Training
 The easiest way of visualizing this is through the motion of a pendulum.  An oscillation is the change in state from an extreme state (A) to the other.
Reduced Cervical range of motion (ROM) may have serious impact on ADL’s, possibly resulting in movement problems, creating local and/or referred pain,
Incident Reporting Procedure
Smart-Grid: Power Distribution and Monitoring Application Cheryl Limas, Daniel Rendon, Advisor – Dr. David Wetz, Advisor – Gregory Turner Department of.
Chemical Health Risk Assessment at Max Fasteners (M) Sdn. Bhd.
Lab Station #1 Directions: Chemistry is the study of the composition, structure, and properties of matter, the processes that matter undergoes, and the.
Interfacing Physics Sensors Using National Instruments Educational Laboratory Virtual Instrumentation Suite & LabVIEW by Eric Ethridge Left to right: motion.
EHSRM (v. 1/04) 1 Environmental Health, Safety and Risk Management Bob Grieshaber Sue Kerns January, 2004.
Respiratory Safety Public Safety Murray State University.
Stephen Joo and Daniel Kattan April 16, 2010 ECE 002, Group 8.
1 HAZARDOUS MATERIAL IDENTIFICATION SYSTEM. 2 A TRAINING PRESENTATION OF THE BRUNSWICK HILLS POLICE DEPARTMENT.
 Defines standard operating procedures to ensure the protection of all employees from respiratory hazards  Includes: ◦ Selection and Use ◦ Cleaning.
The Scientific Method Honors Biology Laboratory Skills.
Fit To Wear. MOHSG Jan 31st Fit To Wear. MOHSG Jan 31st Fit Test Training COSHH 2002.
ENGR 1181 College of Engineering Engineering Education Innovation Center Collecting Measured Data Pre-Class Reading.
Your guide to staying safe in the lab
SHINE SEP Campaign Events: Long-term development of solar corona in build-up to the SEP events of 21 April 2002 and 24 August 2002 A. J. Coyner, D. Alexander,
Does Knowing Who The Artist Is Affect A Listener’s View Of A Song? By Hannah Coombe, Alice Killalea and Lauren Maddock Aim To determine if knowing the.
Sort the graphs. Match the type of graph to it’s name.
EXPERIMENTAL DESIGN Science answers questions with experiments.
Chapter 7 Sampling Distributions Statistics for Business (Env) 1.
Lets prepare for natural disasters since we are not able to prevent them!
What is the purpose of inquiry design? Inquiry/Experimental Design is a series of steps used to investigate natural occurrences/phenomena.
Keeping a Balance: Homeostasis and Negative Feedback
Lab Report Guide IB.
CAD Versus BIM BIM systems contain several noticeable improvements over their CAD predecessors. These improvements lie within the modeling and design features.
Le parc japonais est beau et calme La fille japonaise est belle mais bavarde Ritsurin Park, Takamatsu.
AO-AD Unit 81 NYS Department of State Office of Fire Prevention & Control APPARATUS OPERATOR AERIAL DEVICE Outreach Training Course 79.
The PM DSU generated scorecards data row 11 error message “Assets must have serial numbers” or will not migrate. The NIINS and material descriptions to.
A Relevant and Descriptive Title Your Name and Your Partner’s Name Mrs. Ouellette, Honors Biology Licking Heights High School A Relevant and Descriptive.
Keys to writing a good discussion Remember you are writing the discussion assuming that the reader does not know the scientific theories, so when you make.
Lab Report & Rubric Exercise. Title Title is descriptive and appropriate for the study conducted Interpret and analyze scientific information.
Unit 10 Forensic Science Applications Unit 1 Collecting Evidence Hazards and Protection.
DURAM PERSONAL ESCAPE MASK A simple step for survival Training Manual.
Ruben Carcagno, Sandor Feher, George Velev (team leader) MQXFS1 status meeting Summary of the MQXFS1 Investigation.
Temperature Effect on Photosynthesis Chandler, Kyle, Elsa.
Quad Rat Vitals Monitor Robert Bjerregaard 1, Matthew Bollom 1, Caitlyn Collins 1, Derek Klavas 1 Advisor: Paul Thompson 1, PhD. Client: Alex Converse.
PRODUCT DEVELOPMENT Student Notes. PRODUCT DEVELOPMENT  Is the process of creating new or improved products  Involves brainstorming, designing, building,
Image Processing Diagnostics: Emphysema Alex McKenzie Metropolitan State College of Denver.
Optimization of Graphene Conductivity Under Pressure Variations Robert W. Raines Introduction The purpose of this experiment was to see if the conductive.
Accident analysis One-hour training.
Responsible Conduct of Research: Safe Laboratory Practices Jill M. Daniel Neuroscience and Psychology School of Science and Engineering.
Session 2: Cutting and Shaping Tools; Other Common Hand Tools
Lab Station #1 Directions: During the course of this school year, you will become very familiar with the use of the microscope in this class. A slide.
DEPARTMENT OF MECHANICAL AND MANUFACTURING ENGINEERING
Know About MS Access Database
NON-INVASIVE LUMBAR SPINE MOVEMENT: VALIDATION OF THE MOTIONSTARTM 3-D ELECTROMAGNETIC TRACKING SYSTEM & PRELIMINARY EVIDENCE Aubrey MONIE1,2, Roger PRICE1,3,
AUTOMATED LIQUID DELIVERY SYSTEM
Abby Webster Mentored by Dr. Timothy A. Kluchinsky Jr. Introduction
Instructor Notes There is no DVD associated with this topic.
Public Health Surveillance
Writing reports Wrea Mohammed
Do Rats Have the Ability to Discriminate Between Words?
Presentation transcript:

Characteristics of protection factor leakage based on induced failure mechanisms Lauren Drumm Mentored by Steve Yurechko Gas masks are used for protection against airborne chemicals during biological warfare. The dependability of these masks is essential. How they are put on, how they are transported and stored, and how they are produced, trigger failures when the mask is being worn. A common error with mask failure is the wearer donning the mask incorrectly. Officers from the local police department, when tested at the Protection Factor Facility, initially donned the mask incorrectly (Dalton, 2012). A small leak in a mask is significant to the safety of the person wearing the mask and it is important to recognize these types failures and prevent them. Each mask was tested with specific types of damages that are expected to cause the mask to fail. By testing the masks under conditions that simulate mask failure, it was anticipated that data trends would occur in the Protection Factor (PF) values based on the damage that was inflicted on the mask. The goal was to recognize these trends and create a troubleshooting manual that aids recognition and prevention of failures while the mask is being worn. The manual contains pictures, graphs and tables from each trial, a description of each mechanism, and characteristics from the test that will aid the Protection Factor team. This will reduce the number of hours the PF team spends troubleshooting mask failure and ultimately save the government money. It was anticipated that the failures introduced in the M40 and M50 masks would generate significantly different looking PF graphs. This was not the case. Varying the hole size and location of the hole only altered the magnitude of the PF graph and not the shape. The shape of the PF graph allows for quick comparisons while troubleshooting and was important for the goal of this project, however, these types of graphs are generally created through combinations of unique facial features of test subjects and the particular type of mask worn. There was not enough time to accurately conduct these types of trials. It was verified that negative pressure ground masks perform similarly, regardless of the type of damage that was introduced, Indicating that if future studies were conducted on ground masks, only one mask type may need to be tested (the M50). It is recommended that testing be conducted on aircrew type respirators in the future to determine if the types of damage introduced on the M40 and M50 affect aircrew type masks in a similar way. Conclusion Application Results of this investigation are displayed in the troubleshooting manual for the Protection Factor team. Each testing condition is on one manual page with a description of the type of damage that was introduced, how the damage occurs during normal use, and the graphs and tables of the PF values that were collected during each trial. The manual is organized based on mask type and condition to provide quick and easy access to results from this study. This provides a reference for troubleshooting during future studies, reducing the manpower hours necessary to identify what kind of failure occurred. I would like to thank Steve Yurechko and the Protection Factor team for aiding me throughout this project and allowing me to use their equipment. I would also like to thank Mrs. Gabriel for guiding me through the process. Dalton, K. (2012) Maryland State Police Test Gas Masks at U.S. Army Facility. The Official Homepage of the United States Army. Retrieved from sks_at_U_S__Army_facility/ It was found that regardless of the type of damage that was introduced, the PF graph that was produced followed three distinct trends. The graphs produced on the DAS showed the mask being able to reseal and prevent further leakage throughout a trial resulting in PF values similar to those shown by the green line below. For orifice holes like the 1/16” Hole in Eye Piece shown below, as anticipated, the PF values were consistently low. The trend represented by the blue line is for those conditions that are dependent on the exercise. A control test was performed on the M40 and M50 to ensure that each mask was in good condition before testing began. Five Exercises were completed on each mask for all trials which test the mask as the subject goes through a series of motions. The exercises tested were normal breathing, deep breathing, look left and right, look up and down, and on hands and knees while looking left and right. Graph 1: The graph above represents the trend lines from three completed tests over the five exercises. The exercises changed after each minute. The gold line demonstrates a consistent leak. The blue line demonstrates an unsteady leak. The green line demonstrates the leak closing up and resealing throughout the test. Figure 2: This is a standard M50 gas mask. In this image there is a hole in the eye piece that will be used for orifice testing conditions in the eye piece. Figure 1: The older mask type being tested is the M40 gas mask. A hole was made in the eye piece were orifices were attached for testing conditions. References Acknowledgements Results Materials and Methods Materials and Methods (cont.)Introduction On Hands and Knees Look Left/Right Look Up/DownLook Left/RightDeep BreathingNormal Breathing....