Noise Control in Architecture

Slides:



Advertisements
Similar presentations
Noise Control & Room Modes
Advertisements

AMERICAS TOTAL NOISE CONTROL COMPANY Sound pressure is measured in a unit called decibels and is often abbreviated dB. Zero decibels is the lowest sound.
Airborne Sound Insulation in Buildings
Isolation and Acoustic Preparation Wall's Isolation Window's Isolation Doors Isolation Isolation materials.
SOUND WAVES.
Sound. Sound Waves  Sound waves are longitudinal waves.  The source of a sound wave is a vibrating object.  Only certain wavelengths of longitudinal.
BASIC CONCEPTS IN ARCHITECTURAL ACOUSTICS ENVIRONMENTAL CONTROL III
Do NOW Explain the difference between kinetic and potential energy. Create a KWL chart and fill in the first to columns Copy homework: Read unit 5 lesson.
 PRACTICE PROBLEM ONE: From Previous lecture A 16’ x 20’ x 9’ room has absorptive coefficients as follows: Ignore doors & windows. Walls.30 Floor.25.
Noise Control A Guide for Workers and Employers. Steps used to solve Noise Control Problems Define the problem Establish a noise reduction target Determine.
Noise Reduction Coefficient (NRC)
-ِAcoustics -Arch 353 -Dr. Abdelrahman Elbakheit -References الصوتيات, د. سعود صادق حسن.1.
 Noise Pollution  Noise & Our Hearing  Level of Noise  Measurement of Noise  Classification of Noise  Sources of noise  Impacts of noise  Control.
Sound and Waves.
Acoustical Properties of Materials Chapter 8. Mehta, Scarborough, and Armpriest : Building Construction: Principles, Materials, and Systems © 2008 Pearson.
STRUCTURE-BORNE SOUND INTRODUCTION IMPACT ISOLATION IMPACT ISOLATION CLASS (IIC) IIC IMPROVEMENTS IMPACT NOISES DESCRIPTION:  IMPACT NOISES ARE ERRATIC.
Properties of Sound Physical Science Ms. Pollock
Sound Waves Physic 11 · Chapter 9.
Waves. Examples –Water waves –Sound waves –Light waves –Radio waves –microwaves.
Noise Pollution and Control
Fundamentals of Audio Production. Chapter 1 1 Fundamentals of Audio Production Chapter One: The Nature of Sound.
Terminologies in Acoustics Building Utilities 3 M.S.Chua.
 Space… the sonic frontier. Perception of Direction  Spatial/Binaural Localization  Capability of the two ears to localize a sound source within an.
Sound
Technology in Architecture Lecture 19 Sound Privacy Sound Privacy Enhancement Sound Privacy Reduction Structure Borne Sound Lecture 19 Sound Privacy Sound.
Case Study: The Chapman Graduate School of Business Nicole Figueroa/ Kamilah Bermudez/Elizabeth Berryman Acoustics Assignment #5.
PSAA Curriculum Unit Physical Science Systems. Problem Area Energy and Power Systems.
Sound 13-1 A “physical phenomenon that stimulates the sense of hearing.”
Shrishail Kamble Acoustics is usually very broadly defined as "the science of sound." Hall Acoustics The shaping and equipping of an enclosed space to.
EE Audio Signals and Systems Room Acoustics Kevin D. Donohue Electrical and Computer Engineering University of Kentucky.
EQ: How do different mediums affect the speed of sound?
SELECTING INSULATION MATERIALS  Insulation can serve as more than just an energy barrier, providing fire resistance, humidity control, and noise reduction.
Sound Waves Vibration of a tuning fork
Sound Waves Chapter 13. General Characteristics Longitudinal wave; requires elastic medium for propagation Series of compressions and rarefactions in.
UNIT EIGHT: Waves  Chapter 24 Waves and Sound  Chapter 25 Light and Optics.
Technology in Architecture
SOUND INSULATION. SOUND INSULATION: Is process whereby structures and materials are arranged to reduce the transmission of sound from one room or area.
ARCHITECTURAL ACOUSTICS
ACOUSTICS Stein Reynolds Chapter 17 The Fundamentals of
SOUND ABSORBING MATERIALS. Sound absorption? Or sound proofing If the objective is to stop sound from entering or leaving a space, then you will most.
As you can see, low frequencies are not absorbed as well. This means low frequencies will travel farther. That graph comes from this extremely detailed.
SOUND INSULATING MATERIALS PRESENTED BY : TANDEL RAJAT B. ( ) GUIDED BY:- PROF.N.B.KAGRA GOVERNMENT ENGINEERING COLLEGE, DAHOD CIVIL ENGINEERING.
Unit 14 Lesson 1 What Is Sound? Copyright © Houghton Mifflin Harcourt Publishing Company.
Noise Control of Buildings
Unit 2 Lesson 1 Sound Waves and Hearing Copyright © Houghton Mifflin Harcourt Publishing Company.
 Sound is a longitudinal wave created by a vibrating object.  Sound is a mechanical wave.  PhET Simulation PhET Simulation  Demo: Standing Sound Waves.
Technology in Architecture Lecture 14 Noise Reduction by Absorption Sound Paths Sound Isolation Lecture 14 Noise Reduction by Absorption Sound Paths Sound.
Fundamental Acoustics
ACOUSTICS Aural Comfort & Noise.
Sound Principles of Sound
Regulation and compliance with performance standards
? If a tree fell in a wood and there was no-one there to hear it – would it make a sound?
MASS LAW.
WELCOME.
Sound and Waves.
Objective Sound and Psychoacoustics
Topic 10: Now hear this © Siemens AG All rights reserved.
NOISE CONTROL TECHNIQUES (ENCLOSURES and ABSORPTION)
‘Hearing, sound and the acoustic environment in dementia care’
Sound and Waves.
KS3 Physics 8L Sound and Hearing.
SOUND INSULATION.
Sound and Waves.
Sound.
Sound and Waves.
SOUND WAVES.
Sound and Waves.
Presentation transcript:

Noise Control in Architecture CONTENTS Lesson 1 Noise Control in Architecture What is noise? Sound transmission in architecture Noise Control through architectural design | Noise Control in Architecture | Lesson 1 – Noise Control in Architecture

Noise Control in Architecture Lesson 1 Noise Control in Architecture | Noise Control in Architecture | Lesson 1 - What is Noise?

What is Noise? In daily life, noise means unwanted sound. As you have no doubt experienced, unwanted sounds can include distractions, sounds that are loud enough to damage hearing and even sound leakage that could affect privacy. In architecture, one of the many goals of the designer is to create rooms and buildings that maximize sound performance. This means that unwanted sounds should be prevented, and desired sounds should be enhanced. | Noise Control in Architecture | Lesson 1 - What is Noise?

What is Noise? Sound Intensity I and Sound Intensity Level L Sound intensity is a scientific concept distinct from the more subjective “loudness”. It is defined as power of sound wave per unit area (Wm-2). For example, sound intensity from ticking of watch is around 1 x 10-11 Wm-2, but a jet taken off generates 1 x 102 Wm-2. Difference of powers of sound wave between the watch ticking and a jet is 1013 times. This scale is not comprehensive enough to tell the loudness of sound. A logarithmic scale is used to measure sound intensity. It is called sound intensity level. Sound Intensity Level is defended as: L = Sound intensity level (dB); I = Measured sound intensity (Wm-2); and I0 = Standard sound intensity (Wm-2), the softest sound intensity that human ear can hear. The standard reference of I0 is 10-12 Wm-2. | Noise Control in Architecture | Lesson 1 - What is Noise?

What is Noise? Difference Between Noise and Sound Intensity Level Noise is a subjective and relative perception, but sound intensity level is a scientific measure of the power of sound. Even if a sound source has a relatively low sound intensity level, some individuals might find a certain frequency of sound wave annoying because the human ear reacts differently to different frequencies of sound (pitches) and the hearing ability of individuals is subjective. Sound intensity level can only be used as a standard to identify the volume of sound that could cause hearing damage. It does not represent the exact perception of the sound to individuals. | Noise Control in Architecture | Lesson 1 - What is Noise?

What is Noise? Sound Transmission in Architecture Sources of Noise The two major sources of noise in architecture are: Airborne noise, or sound waves transmitted from a source to a receiver through the air. Structure-borne noise is caused by vibration from within the building caused by footsteps or machines. The vibration is directly transferred through the building’s structures and materials. A B C The sound of a plane’s engine is a kind of exterior airborne sound that may affect communities near airports. The MTR’s operating systems are quiet, but the vibration of the train rail generates exterior structure-borne noise. In a gymnasium, cheering spectators may cause interior airborne noise to the surrounding rooms, while the athletes’ activities generate interior structure-borne noise. | Noise Control in Architecture | Lesson 1 - Sound transmission in architecture

What is Noise? Sound Transmission in Architecture | Noise Control in Architecture | Lesson 1 - Sound transmission in architecture

What is Noise? Noise transmission paths Sound waves travel from the source to the receiver via multiple paths. Altering the paths of sound transmission is a common way to control noise in architecture. When sound strikes on a surface, part of the sound reflects off the wall surface back into the space, and part of it is transmitted through the wall to the space beyond. Flanking transmission of sound Flanking transmission is the propagation of sound wave via building elements. An air gap can stop the transmission of sound effectively. [Discussion] How is unwanted sound transmitted in this diagram? | Noise Control in Architecture | Lesson 1 - Sound transmission in architecture

Noise Control through Architectural Design Reducing Transmitted Sound Intensity Level When sound wave travels through air or materials, the transmitted sound intensity level is reduced due to sound power loss. Almost every material exhibits sound insulating properties. They only vary in their level of acoustic performance, which is measured in terms of the Sound Transmission Loss or Sound Reduction Index. Sound Reduction Index When two partitions or sound barriers are completely separated and isolated from one another, their ability to reduce sound is increased. | Noise Control in Architecture | Lesson 1 – Noise Control through Architectural Design

Noise Control through Architectural Design Extended Knowledge The Sound Reduction Index of a material as it affects a specific frequency of sound can be found using the following equation: Where, SRI= Sound Reduction Index (dB) M= The mass per unit area of the material (kgm-2); and f =Frequency of the sound (Hz). The sound insulation performance of any homogenous material depends mainly on its mass. | Noise Control in Architecture | Lesson 1 – Noise Control through Architectural Design

Noise Control through Architectural Design Possible Perspectives Sound Reduction Index of common building materials (Source: “Noise Control in Mechanical Services”, 1972) Sound reduction required from the meeting room = 45 - 35 dB = 10dB Sound reduction required from the nearby sports courts = 70 – 25 dB = 45dB The wall of the meeting room should have a Sound Reduction Index ranging from 10 dB to 45 dB. According to the graph of Sound Reduction Index, three building materials could be suitable for the meeting room: • 50 mm Plastered Breeze Block (a light concrete building block made with cinder aggregate) • 9 mm Glass • 0.7 mm Sheet Steel After obtaining the data from an acoustic consultant, architects decide what materials should be used for the functions and aesthetics of the space. Other considerations include structural tolerance, environmental concerns and universal design for all users. | Noise Control in Architecture | Lesson 1 – Noise Control through Architectural Design

Noise Control through Architectural Design [Discussion] The school principal prefers using plywood as the wall surface. He comments that a glass wall is not good for privacy but he wants to introduce natural lighting and ventilation to the new meeting room. What possible solution would you suggest? | Noise Control in Architecture | Lesson 1 – Noise Control through Architectural Design

Noise Control through Architectural Design Possible Perspectives A double-leaf plywood wall could be constructed with a row of double-glazed operable clerestory windows for natural lighting and ventilation. Double-partition wall insulation When two sound barriers are completely separated and isolated from one another, sound insulating performance is enhanced. Sound absorption materials like mineral wool can be used to fill the cavity for extra sound insulation against flanking transmission. © NAP Acoustics (Far East) Ltd Double-glazing An operable double-glazed window provides horizontally offset openings that allows natural ventilation while preventing direct propagation of traffic noise. The narrow path between the double window panes dissipates sound energy and lowers noise levels relatively. | Noise Control in Architecture | Lesson 1 – Noise Control through Architectural Design

Noise Control through Architectural Design Redirecting Sound away from Receivers Artificial noise screen Noise barriers can redirect the paths of noise away from receivers. They can be artificial (for example, a wall) or natural (a forest). One common application for noise barriers is to prevent traffic sounds from penetrating nearby neighborhoods or habitats. Sometimes noise barriers are integrated with the building design. Noise sensitive buildings like residential blocks may be built above a podium or a shopping mall that inhibits the transmission of noise to the apartments. | Noise Control in Architecture | Lesson 1 – Noise Control through Architectural Design

Noise Control through Architectural Design [Discussion] Can you identify the noise sources and barriers in the images and trace the sound transmission paths? Mark them on the following picture. | Noise Control in Architecture | Lesson 1 – Noise Control through Architectural Design

Noise Control through Architectural Design Case Study – Kwai Tsing Theatre Isolating structure-borne noise from the building © WAAGNER-BIRO AG Kowloon’s Kwai Tsing Theatre illustrates how architectural design can be used to protect quiet spaces against airborne and structure-borne noises from inside and outside the theatre. Its location next to the MTR railway and heavy traffic is particularly challenging given the requirements of the theatre’s multifunctional spaces, which sometimes host simultaneous events. | Noise Control in Architecture | Lesson 1 – Noise Control through Architectural Design

Noise Control through Architectural Design Case Study – Kwai Tsing Theatre Photographs showing how the springs integrate with the structure of Kwai Tsing Theatre; © VIPAC Engineers & Scientists (HK) Ltd Springs placed on the pile caps of the building can absorb exterior structure-borne noise before it is transmitted to the interior. Theatre and music rooms are built inside an isolated shield to reduce flanking transmission of noise. Noise-isolating springs c NAP Acoustics (Far East) Ltd | Noise Control in Architecture | Lesson 1 – Noise Control through Architectural Design

Noise Control through Architectural Design Case Study – Kwai Tsing Theatre Improving the Sound Reduction Index of the Structure The ceilings, walls and floors of the theatre are isolated from building structure by springs or resilient pads. An air gap around the floating floors and suspended ceilings also improves the Sound Reduction Index of the structure. | Noise Control in Architecture | Lesson 1 – Noise Control through Architectural Design

Noise Control through Architectural Design Case Study – Kwai Tsing Theatre The air gap is the most important factor – increasing it (rather than increasing the mass of the floors) would achieve greater reductions in noise as compared to increasing the mass of the structure or the floating floor. © VIPAC Engineers & Scientists (HK) Ltd | Noise Control in Architecture | Lesson 1 – Noise Control through Architectural Design

Summary Noise means unwanted sound. It is subject to human perception. Sound Intensity Level is a scientific approach providing A logarithmic scale is used to measure sound intensity (Wm-2), and is expressed as: Noise control in architecture is dealing two sources of noise: airborne and structure-borne. | Noise Control in Architecture |

Summary Two ways to control noise: reducing transmitted Sound Presure Level and reddirecting sound transmission paths to the receivers. Sound Reduction Index is used for the purpose of choosing the appropriate sound insulating performance for a building. It indicates the degree of sound intensity reduction when a sound wave passes through a material. Noise barrier redirects noise transmitting paths to the receivers. | Noise Control in Architecture | 22 22