Electrocardiogram Amplifier Design Using Basic Electronic Parts Background Lecture.

Slides:



Advertisements
Similar presentations
Resting ECG An overview.
Advertisements

Removing the Mysteries
BIOPOTENTIAL AMPLIFIERS
ECG Biopotential Amplifier ASHLEY MULCHRONE ZEXI LIU.
A brief introduction to the standard 12-lead ECG (EKG)
The electrocardiogram (ECG or EKG)
12-Lead ECGs and Electrical Axis
The Electrocardiogram
Cardiac Physiology II Frank A. Acevedo, PA-C. Excitation.
ELECTROCARDIOGRAM (ECG)
Cardiovascular System Block The Electrocardiogram (ECG)
Aims Introduction to the heart.
ECE 501 Introduction to BME
The Standard 12-ECG System
Example Problem You are measuring the EEG of a patient and accidently choose two different types of electrodes for EEG lead. One of them has a source impedance.
Sandipan Dasgupta (10MS12) 3 rd year UG, Department of Biological Sciences Electro Cardio Graphy Sandipan Dasgupta, Indian Institute of Science Education.
Cardiovascular Block Electrocardiogram (ECG)
Electrocardiography Prof. K. Sivapalan ECG 2 Principle of Electrocardiogram. Trunk as volume conductor. Positively charged and negatively charged.
Co-ordination of the Cardiac Cycle Aims Describe how heart action is coordinated with reference to the sinoatrial node (SAN), the atrioventricular node.
EKG Basics.
ECG Dr Mahvash Khan MBBS, MPhil. The ECG is a record of the overall spread of electrical activity through the heart.
Enhancing the Capabilities of a Wireless Holter Monitor Senan Garry 4 th ECE.
Chapter 4 The Operational Amplifier
Your heart is a muscle that works continuously like a pump Each beat of your heart is set in motion by an electrical signal from within your heart muscle.
Topic 28: Direct Sensing 28.1 Sensing devices
Introduction to Electrocardiography
Lecture 8 Electrical energy EMF Resistors in series and parallel
Disease of Cardiac System
Normal electrocardiogram
1 ECG Signal Make-up. 2 Biopotential Requirements n High Input Impedance –Minimum loading of the signal being measured –Minimum 10M  n Input circuit.
EE 1270 Introduction to Electric Circuits Suketu Naik 0 EE 1270: Introduction to Electric Circuits Lecture 13: Operational Amplifiers Part 2 Chapter 5.
EKG. Objective: The student will become familiar with an EKG and how it works to record the electrical activity of the heart The student will become familiar.
Copyright © 2007 by Saunders, Inc., an imprint of Elsevier Inc. Principles of Electrocardiography Chapter 48.
Dr. Mona Soliman, MBBS, MSc, PhD Department of Physiology Chair of Cardiovascular Block College of Medicine King Saud University.
Vital Signs Monitor UConn BME 4900 Vital Signs Monitor Purpose As the population ages, many people are required by their doctors to take vital signs.
The Conducting System and EKG Danny Golinskiy, Joel Levy, Emily Brames.
OBJECTIVE Without reference, identify at least four out of six principles pertaining to the application of transducers related to patient care.
ECG How ECG is done? The electrical impulses originating from the heart can be transmitted to the body surface because the body contains fluids.
ELECTROCARDIOGRAM (ECG)
Electrocardiographs ECG. OUTLINES : Introducing what is meant by Biopotential signals. what is Electrocardiograph (ECG). The conduction system. The standard.
ECG Basics.
Erwinanto Div. Of Cardiology, Dept. of Internal Medicine Padjadjaran University School of Medicine Hasan Sadikin Hospital Bandung.
1 Electrocardiography – Normal 6 Faisal I. Mohammed, MD, PhD.
ECG M.Bayat Ph.D.
Cardiovascular Physiology
The Heart Continued... Human heartbeats originate from the SA node near the right atrium. Cardiac muscle cells contract, sending a signal to other muscle.
Electrocardiogram (ECG/EKG)
Electrocardiograph. History Italian scientist Carlo Matteucci realizes that electricity is associated with the heart beat Irish scientist.
Electrocardiography (ECG) Electrocardiogram  The tracing made by an electrocardiograph  Electrocardiograph an instrument for recording the changes.
Electrocardiogram Amplifier Design Using Basic Electronic Parts
ECG (EKG) Electrocardiogram This PowerPoint is set up as a self-tutorial. View on full-screen mode.
22nd April 2009 ECG Recording and Basic Interpretation.
Physiologic signals Lecture (2).
Biomedical Instruments Design Biopotential Amplifiers
ECG 1.BIPOLAR LEADS I II III 2.UNIPOLAR LIMBS LEADS AVR AVL AVF
Electrocardiography A recording of the electrical activity of the heart over time Gold standard for diagnosis of cardiac arrhythmias Helps detect electrolyte.
Electrocardiography – Normal 5
The Heart and Circulation
Cardiovascular Block Physiology The Electrocardiogram (ECG)
ELECTRICITY WITHIN THE BODY
Introduction to the E.C.G.
Design Team 3 Texas Instruments Contact: Pete Semig Facilitator:
©2012 Lippincott Williams & Wilkins. All rights reserved.
ECG 1.BIPOLAR LEADS I II III 2.UNIPOLAR LIMB LEADS aVR aVL aVF 3.UNIPOLAR CHEST LEADS C1………..C6 4.RECORDING OF THE ECG.
Biomedical Instruments Design Biopotential Amplifiers 1.
Biopotential amplifiers
The Heart and Circulation
ECG – electrocardiography
(VII.) Electrocardiography
Presentation transcript:

Electrocardiogram Amplifier Design Using Basic Electronic Parts Background Lecture

Outline of Discussion Project scope: What are you going to do? Background: What is ECG? –Clinical relevance and importance –Technical challenges in measuring this signal Project description: How will you do the project? –Overview of project stages –Technical principles related to each stage Conclusion: What are the learning outcomes?

Project Scope

Overview of Project Topic: Biomedical circuits –Interdisciplinary in nature –Involve technical concepts in three areas: 1)Electric circuits 2)Biomedical instrumentation 3)Human physiology Project aim: Develop an ECG amplifier circuit from scratch –Learn about technical details behind bio-potential measurement devices –Help build your interest in BME or EE!

Background Overview of ECG

Background: Where is your heart? ABC

Background: Heart Diseases Statistics from World Health Organization (2005) –Heart disease kills one person in every 5 seconds –7.6 millions of death worldwide each year Common types of heart problems –Heart rhythm disorder: Irregular beats –Coronary heart disease: Cannot supply adequate circulation to cardiac muscle cells –Tachycardia: Heart beats very fast even whilst at rest ** Electrocardiogram (ECG) Monitoring ** One common way to help diagnose for heart diseases

Basic Principles of ECG Physiological origin: Sequential electrical activation of cardiac cells –Electrical excitation propagates from top to bottom of heart –Starting point: sinoatrial node (at top of heart) –End point: ventricular muscles Responsible for triggering cardiac contraction –Activation does not rely on brain signals  Heart can operate on its own Source:

ECG: A Time-Varying Signal Heart can be viewed as a time-varying voltage source –Net voltage amplitude = Sum of cardiac cell potentials –Voltage vary periodically based on cardiac cycle

ECG Waveform Characteristics Waveform usually contains three distinct segments P wave (atrial excitation) QRS complex (ventricular excitation + atrial recovery) T wave (ventricular recovery)

Clinical Importance of ECG Can provide critical insights on potential abnormalities in the subject’s heart functioning –Commonly used as a first line of monitoring for cardiac problems Example #1: Heart rhythm disorder –Technically known as arrhythmia –Give rise to aperiodic ECG waveforms

Clinical Importance of ECG Example #2: Atrial fibrillation –Missing P waves due to asynchronized excitation of atrial cardiac cells Example #3: Premature ventricular contraction –Sudden broad change in the QRS complex shape

How to measure ECG? Back in the old days…

ECG Measurements: Basic Principles General approach: Place electrodes at multiple places on the body surface –Measure potential difference across a lead (i.e. a pair of electrodes) –Exploit the fact that body tissue is a conductive medium that can relay cardiac potentials Commonly used electrodes: Metal disk surrounded by an adhesive foam pad –Can self-attach to subject during operation

Project Description

Challenge in ECG Measurements Raw ECG signals often low in amplitude and distorted by noise sources –Magnitude range: 0.1 to 5 mV –Examples of interference sources: 1) muscle contractions, 2) power-line radiations Problem with having poor signal quality: Hard to obtain physiological insights –Low signal level  Difficult to detect –High noise level  May mask out useful clinical info

General Solution: Amplification Circuit Aim: To boost the raw ECG signal level –Preferably without boosting the noise at the same time Approach: Amplify only the potential difference across two contact points –Theoretically allows only AC signals to be amplified ** This is what you will do in this project!! ** Amplifier Amplified Lead Output Contact Node #1 Contact Node #2 V+V+ V–V–

What you will do in this project… Objective: Prototype an electronic circuit to amplify the potential difference across a lead –Circuit built on a breadboard –Use only basic circuit components like op-amp chips, resistors, and capacitors –Testing conducted using an ECG signal simulator (MCI-430, MediCal Instruments) Time required: hours Work in teams of at most three people

Project Structure Stage #1: Instrumentation amplifier design –Develop an amplifier with a gain large enough to boost raw ECG signals –Account for common-mode noise Stage #2: Power source reduction –Fine-tune ECG amplifier circuit by using only one 9V battery to drive it –Involve creating a virtual circuit ground Stage #3: Multi-lead ECG measurements –Use the completed amplifier to estimate direction of ECG propagation in the simulator –Involve measuring ECG from 12 different leads

Stage #1: Instrumentation Amplifier

Stage #1: Technical Description Aim: Design a circuit that only amplifies the differential voltage –Common-mode voltage level remains unchanged Method: Build an instrumentation amplifier –Circuit structure involves two main stages Input Conditioner vovo Difference Amplifier vava vbvb + – Ensure input impedance approach infinity, and apply a gain Amplify the difference of the conditioned input signal

Main Design Considerations 1)Amplifier gain –How much amplification is needed given that raw ECG signal is between 0.1 to 5 mV? 2)Circuit noise level –How can we reduce power-line interference? 3)Power consumption –Can we save power and extend the battery life?

Technical Details: Instrumentation Amp. Overall differential gain is given by: R4R4 R3R3 vovo R3R3 R4R4 R2R2 vava R2R2 R1R1 vbvb V S+ Difference Amplifier Input Conditioner V S–

Problem: Power-Line Interference Origin of common-mode noise: Radiations from power lines –Emitted radiation induces current  Give rise to voltage when connected to circuit load –v cm can be as high as 50 mV!!! Instrumentation amplifier can reduce common-mode noise, but not completely

Power-Line Noise Reduction Approach: Suppress common-mode voltage via shunting the displacement current to ground Implemented by adding an extra contact node with subject –Usually the at the right leg (RL)

Stage #2: Power Source Reduction

Stage #2: Technical Description Aim: Convert amplifier to a single-supply-driven circuit without affecting its operations –i.e. Use only one battery to power the op-amp chips Method: Create a virtual circuit ground via voltage divider –Involves creating an extra circuit block  Circuit becomes more complicated v+v+ v–v– vovo V S+ Dual-Supply Op-AmpSingle-Supply Op-Amp v+v+ v–v– vovo V S+ V S– Physical GND

Main Design Considerations 1)Impact of removing the negative battery –How would this affect the operation of the circuit? 2)Virtual ground voltage –What should the ground voltage value be to sustain normal operation of the amplifier circuit? 3)Suppression of virtual ground fluctuations –How can we ensure that the virtual ground voltage remains the same regardless of circuit load?

Technical Details: Virtual Ground Virtual ground voltage is given by: –Can adjust it by changing R a and R b !! This voltage can be stabilized via two ways: V battery Physical Ground RaRa V virtual RbRb V S+ V virtual Op-amp voltage bufferShunt capacitors Virtual Ground V S+ C C

Stage #3: Multi-Lead ECG Measurements

Stage #3: Technical Description Aim: Estimate the true direction of ECG potential propagation using your completed amplifier Method: Acquire ECG signal from multiple leads –12 leads commonly used in clinical diagnoses

Technical Details: Lead Angle Detected voltage affected by electrode location due to spatial dependence of cardiac electric field –Strongest potential when lead parallel to ECG field –Zero potential when at 90° –General relationship: | V detected | = | V actual | cos  Makes sense to measure ECG from multiple angles in practice!

Clinical Practice: Frontal ECG Useful for examining cardiac electric field along front side of human body –Often regarded as the traditional form of ECG recording Three basic electrode points placed at the limbs –Locations: 1) Right arm (RA), 2) Left arm (LA), 3) left leg (LL) –Forms three leads with pointing directions at ~60° against each other  Forms a triangle known as Einhoven triangle

Clinical Practice: Frontal ECG Three additional leads sometimes included in clinical ECG systems –Formed from connecting RA, LA, and LL electrodes with a central ref. node (Wilson’s central terminal) –Naming: 1) aVR (right arm); 2) aVL (left arm); 3) aVF (foot) Total frontal ECG leads = 6 –3 basic + 3 augmented –Helps to more accurately identify the instantaneous cardiac cycle phase during operation

Technical Details: Central Terminal General approach: Voltage summing circuit –Need the resistor R in each branch to avoid short circuit Connect the RA, LA, and LL nodes to this summing circuit to get Wilson’s central terminal –This node is positioned at center of Einhoven triangle

Clinical Practice: Transverse ECG Useful for examining cardiac electric field over a cross-section around the heart Six electrode points placed below chest –Forms six leads with pointing directions at ~30° against each other Clinical systems usually perform frontal and transverse ECG simultaneously –Involve 12 leads in total (6 frontal + 6 transverse)

Concluding Remarks

Conclusion: Learning Outcomes 1)Explain biopotential amplifier circuits to others –Their practical importance and technical details –How they can be used for ECG potential measurements 2)Develop an ECG amplifier –Implemented on a breadboard –Use only basic parts like op-amp chips, resistors, & capacitors 3)Address the power-line interference problem –Why they appear as common-mode noise in ECG signals –How to reduce them 4)Describe the issue of measurement lead angle –Why the detected ECG magnitude depends on the angle between a lead and the actual ECG potential direction