Period 5 Orac. The cathodic protection equivalent circuit.

Slides:



Advertisements
Similar presentations
CIRCUITS AND ELECTRICAL FLOW. The amazing image which follows shows a picture of earth taken at night from outer space. The street and house lights illuminate.
Advertisements

» When you have completed this module you will know, what components do, what they physically look like and how they are represented in a circuit diagram.
Chapter 20 Electricity. Section 1 Electric charge and static electricity.
Electricity & Magnetism
Current. Current Current is defined as the flow of positive charge. Current is defined as the flow of positive charge. I = Q/t I = Q/t I: current in Amperes.
Series and Parallel Circuits
© 2007 Pearson Prentice Hall This work is protected by United States copyright laws and is provided solely for the use of instructors in teaching their.
Fundamentals of Circuits: Direct Current (DC)
Electric and Magnetic Phenomena
VOLTMETER LOADING EFFECTS
Cutnell/Johnson Physics 8th edition
Cutnell/Johnson Physics 8th edition
2/6/07184 Lecture 171 PHY 184 Spring 2007 Lecture 17 Title: Resistance and Circuits.
MEASUREMENT DEVICES OUTLINE Multimeters Analog Multimeters
Foundations of Physics
Chapter 11 – Inductors Introductory Circuit Analysis Robert L. Boylestad.
CHAPTER 17 Current Electricity
RESISTANCE. The resistance of a conductor is the ratio of the potential difference across it to the current flowing through it.
Dynamic Presentation of Key Concepts Module 2 – Part 3 Meters Filename: DPKC_Mod02_Part03.ppt.
Electrical Electricity Fuses Relays Solenoids Electrical Testing
Chapter 27 Lecture 12: Circuits.
Chapter 19 DC Circuits.
Lecture Outline Chapter 21 Physics, 4th Edition James S. Walker
Current. Current Current is defined as the flow of positive charge. Current is defined as the flow of positive charge. I = Q/t I = Q/t I: current in Amperes.
In conclusion, there are two requirements which must be met in order to establish an electric circuit. The requirements are: 1.There must.
Chapter 21 Electricity. Opposite charges attract, like repel Charged objects can cause electrons to rearrange their positions on a neutral object.
7.2.3 Student Book © 2005 Propane Education & Research CouncilPage Identifying Procedures for Measuring Resistance Between Two Given Points in.
Electric Circuits AP Physics B.
Unit 7: Electricity and Magnetism
Electric Circuits.
Electric Components. Basics 1 Current: electrons moving together in same direction (electrons are always moving in materials like metals but in a random.
Chapter 26 DC Circuits. Units of Chapter EMF and Terminal Voltage - 1, Resistors in Series and in Parallel - 3, 4, 5, 6, Kirchhoff’s.
Nature of Electricity. Nature of Current Electricity To make things work  Need source 1.5 V cell has a limited life ( use it then throw it away) 240.
1 Pulsing Dial Limits : The nominal dial characteristics are speed = 10 pps, ratio = 2/3 break, 1/3 make. In practice dials are set to maintenance limits.
Electricity and Magnetism
Chapter Electric Current
Chapter 20 Electric Circuits. A battery consists of chemicals, called electrolytes, sandwiched in between 2 electrodes, or terminals, made of different.
Corrosion control measurements Incorrect assumptions are making pipeline corrosion control impossible.
Today Course overview and information 09/16/2010 © 2010 NTUST.
© 2002 University of North Carolina at Charlotte, ALL RIGHTS RESERVED Basic DC Circuits Review.
Unit 5 Learning Objective(s) L5.1a To understand the need for safe working practices when carrying out practical electronics L5.1b To understand relevant.
AP Physics C Electric Circuits.
Chapter 22 Magnetism and its uses Characteristics of Magnets Greeks experimented more than 2000 years ago with a mineral that pulled iron objects.
35 Electric Circuits Electrons flow from the negative part of the battery through the wire to the side (or bottom) of the bulb through the filament inside.
For week three go over electron flow and conventional flow. Electrons only flow in one directions.
Mr. Gillis’ Science Class. What needs to happen to get the bulb to light?
The Basics Electronics. To familiarise yourself with electronics To have an understanding of how and why we test electronic circuits. To complete a test.
Electricity and Magnetism
Electric Circuits AP Physics C. Potential Difference =Voltage=EMF In a battery, a series of chemical reactions occur in which electrons are transferred.
Period 3 The issue. Attempted solutions The key to all this activity was the field use of the half-cell as a reference electrode. Very early in my field.
Electricity and Magnetism  16.1 Electrical Potential Energy  16.2 Equipotentials and Electric Fields  Capacitance and dielectrics  17.1 Batteries.
Period 4 Instrumentation. Misunderstanding instruments. The development of the digital voltmeter had a considerable influence on those involved with cathodic.
Solar Magnetic Fields. Capacitors in Circuits Charge takes time to move through wire  V is felt at the speed of light, however Change in potential across.
Automotive Heating and Air Conditioning CHAPTER Automotive Heating and Air Conditioning, 7e James D. Halderman | Tom Birch SEVENTH EDITION Copyright ©
Objectives 1. Demonstrate the requirements for an electrical circuit that works. 2. Use a multimeter effectively to measure voltage and current in a simple.
Unit 11 - Electric Circuits Physics Book Chapters 19 and 20 Conceptual Physics Book Chapters 33, 34, 35.
Automotive Heating And Air Conditioning
Electrical Circuits They keep the lights on!!.
Associate Professor, ECE Dept.
Lesson 4: Series DC Circuits and Kirchhoff’s Voltage Law (KVL)
Electronics Circuits.
Basic DC Circuits Review
Period 6 What is Orac 2?.
Basic Corrosion Theory
ELECTRICAL QUANTITIES IN CIRCUITS
Unit 2.3 Electric Current.
Resistors and Ohm’s Law
Foundations of Physical Science
Savannah, Javier, Donovan, Amelia
Presentation transcript:

Period 5 Orac. The cathodic protection equivalent circuit.

Above ground

Below ground

Orac has been re-made The original was stolen by someone in the cathodic protection industry. I made another in the UK that is out on loan, and forgotten to give back. I made another with the help of a trainee technician in Brazil and that is still at our training centre. I made another in South Africa with the help of a trainee and it is still there. The one you see in the pictures in this presentation is part of my laboratory, here in the UK.

Orac works well. ( Named after the portable computer in the television series 'Blake Seven') Orac is a demonstration of the features encountered during the measurement of voltages in cathodic protection field work. The original Orac was based on the lid from a biscuit tin, made of a handful of scrap electronic components, a battery and two multi-meters all set in a briefcase. It was seen by the head of corrosion control at Shell International in the Hague who wanted to buy it.

Why is Orac? It was build to investigate the claims of some of the worlds most respected cathodic protection experts, and proves that some of their theories simply do not work in practice. This is fine, but destructive criticism is not much good to anyone.

The ‘IR drop in the soil’ measured at ground level

The ‘IR drop in the soil’ measured 1 strata down

The ‘IR drop in the soil’ measured 2 strata down

The ‘IR drop in the soil’ measured close to coating fault.

How does Orac Help? Orac was built to show some more likely explanations for the value of voltages read during conventional cathodic protection monitoring. The electronic components have been constructed to give similar readings to those actually experienced in field work. This helps the engineer to build up a concept of cathodic protection which enables effective cathodic protection trouble shooting.

The bits and pieces. Meter 1 This is a typical digital multi-meter such as is used in cathodic protection monitoring. It measures similar values with similar accuracy to those used in industry, world-wide. It allows very little current to pass through the measuring circuit. Meter 2 This is a cheap, analogue multi-meter based on a galvanometer. It is not particularly accurate as it requires current to pass through the measuring circuit to activate the magnet which then pulls against the hairspring, to move the indicator needle across the face of the meter. Drawing this current reduces the potential difference between the poles of the meters, and therefore reduces the value of the voltage which is read. The reduction in voltage, caused by this meter can be measured using the digital meter and Orac.

Components The battery This is simply a method to create an electrical imbalance in the circuit. This can be replaced with a small 'plug-in' transformer rectifier, such as is readily available to power a multitude of domestic devices. The demonstration works equally well with either source of power and will even function when connected directly to a cathodic protection transformer rectifier in the field. The base This was a biscuit tin lid, made of tin plated steel sheet to which electronic components can be soldered to give a good electrical connection. This base enables a simulation of the 'mass earth' concept which is an axiom in cathodic protection theory. Both in the field and in Orac there is a virtually resistance free path for current which has entered 'mass earth'. This is now a copper sheet from any electronics supplier.

Arrangement The input control This is a variable resistor which allows control of the current which is fed from the battery to the base. The groundbed resistors This is a network of randomly selected resistors soldered together in three dimensions. It is a concept of any part of the earth in which the current distributes itself throughout the network according to the basic laws of electricity. This feature is provided to demonstrate the impossibility of measuring the exact amount of current passing through any particular node in the same way that it is impossible to determine the exact amount of current passing through any particular point in the earth in the groundbed area. The whole area is 'charged up' and the current will pass to mass earth through the least line of resistance. Groundbed to remote earth resistances Two variable resistors connect the groundbed network to the base. This enables the demonstration of the effects of a high groundbed resistance, and illustrates the advantages of seeking to build a low resistance groundbed.

The pipelines … conductors The pipeline The pipeline is represented by a series of resistors soldered end to end to show the typical resistance in the metal of a fairly long, large diameter, pipeline. The actual value of the resistance of each pipeline depends of the wall thickness, the diameter and the length but the values in Orac will be found to be fairly typical, and can be calculated from the colour coding of the resistors which are used. It was necessary to use some resistor in parallel during the construction of Orac, but these can be imagined as pipeline manifolds for the purposes of experiments. The coating resistance The pipeline is connected to the base on 'pillars' which are in fact high resistances and two variable resistances. Each of the fixed resistances can be conceived as the actual coating resistance and the variable resistors can represent coating faults. It is possible to adjust the total resistance of the coating and the disposition of this resistance along the pipeline to simulate areas of poor coating. The variable resistors are under the plastic cover and difficult to access in the same way the it is necessary to excavate to the pipeline to make any effect on the coating. It is appreciated that the pipeline can be short-circuited to other buried metal but this can be simulated on Orac by direct connection between the 'pipeline' and a suitable variable resistor connected to the base. This is one use of the extensions on the right hand side of Orac.

Test posts The test post positions These are represented by access holes through which the meter connections can be made. This is the same as making a direct connection to the pipeline metal through a test facility in field work, and the same affect is achieved on Orac. Earth contact positions These are provided as bare ends of the wires that poke through the plastic cover of Orac. These are displayed in this way so that the connection can be made using the meter probes or by making contact with the porous plug of a standard copper/copper sulphate electrode. Model extensions A red and a green wire are provided at the right hand side of Orac to enable the pipeline and the groundbed to be connected to other demonstration pieces. Electrolytic capacitor This is included to demonstrate the including it in the circuit can reproduce the effect of the so-called decay in cathodic protection which is manifest when the cathodic protection is switched off. Orac can therefore demonstrate 'immediate off' readings using a recording voltmeter or data-logger.

What can Orac demonstrate? Orac was built to test the truth of statements made in leading text books relating to cathodic protection practice. Many of these quote 'equivalent circuits' and have illustrations similar to those that are seen in electronic drawings. It is therefore logical to build the arrangement and apply the potentials to become familiar with the behaviour of the meter when used for monitoring the electrical behaviour. Theory has to be correct for the model to work, but when it does it then makes the theory easy to understand. Orac enables all experiments to become readily repeatable and facts to be properly established. Orac can demonstrate the difference between an analogue meter and a digital meter. The meter is placed between the two potentials and the current passing through the meter allows the potentials to equalise, to a limited extent. The analogue meter continues to demand energy to balance the elastic memory of the hair spring, whereas the digital meter can be likened to filling up a number of containers in a row and displaying the amount of the fill on a screen powered from an independent source of energy.

One of the demonstrations Orac can demonstrate the difference between analogue and digital meters by the following procedure. Connect the battery terminals to the two clips. Connect the digital meter to test post 1 and a half cell position in normal soil. Switch on the meter and adjust the output until the meter reads 1.5 volts. Set the analogue meter to the 10 volts DC range. Connect the negative pole of the meter to the green extension lead from the pipeline. Watch the digital meter reading, while touching the positive analogue connection to the same half cell position connection as that connected to the digital meter. Note that the reading reduces from about 1.5 volts to about 0.72 volts. Watch the dial of the analogue meter while touching its positive connection to the same half cell position on Orac as that connected to the digital meter. Note that the meter needle shows about 0.5 volts. Connect the analogue meter permanently across the same connections and disconnect the digital meter positive connecting. Note that there is little detectable movement to the analogue meter caused by the disconnection of the digital meter. Touching the digital meter lead to and from the connecting points will confirm this.

Important basic understanding. This experiment proves that the meter simply short circuits the two subject potentials and that the higher the resistance in the meter the lower the ratio of error that it introduces. Applying this principal to cathodic protection monitoring it becomes apparent that the introduction of digital meters increased the apparent success of applying cathodic protection, by increasing the value of the voltages that were measured. Cathodic protection engineers were able to attain the criterion of volts and pipelines were considered to be protected, but some time later failed due to external corrosion.

The position of the electrode is critical. Orac can allow engineers to measure voltages and current measurements that can be computer analysed. These can be compared directly to measurements made in the field during CIPS surveys How to do this using Orac. By leaving the negative terminal of the digital meter connected to the pipeline at test post 1 and moving the positive connection to a variety of connecting points, it can be seen that the resistances between the groundbed and the electrode have a major effect on the readings. Four connections are provided and labelled 'half-cell positions in normal soils'. These connections are extensions of a network of resistors which are connected to the base. This is the same concept as connecting the electrode to a random point on earth while taking a conventional 'pipe to soil potential reading' during cathodic protection monitoring. The connection is at the earth surface to a finite point of resistance as represented on Orac.

Equivalent CIPS survey Connect the DC V pole of the digital meter to the pipeline through test post 1 and the common pole of the digital meter to the left hand wire of the 'half cell positions in normal soils'. Switch on the meter and connect the battery. Adjust the output to get a steady reading of 1 volt. Move the positive meter connection to the second position from the left, then to the third and then the fourth. Note that this produces little change, in spite of the slightly different resistances in the measuring circuit. Move the positive meter connection to the wire labelled 'dry tarmac'. Note that the meter reading reduces from 1 volt to about 0.95 volts. This is due to the increased resistance between the base and the connection point. It reduces the amount of current which is available to be measured by the meter and thereby reduces the reading. Move the positive meter connection to the wire labelled 'dry concrete' and the reading reduces to about volts for the same reason that it reduced as described above. Note that the resistances in steps 5 and six are introduced in the measuring circuit.

CIPS continued Move the positive connection of the digital meter to the position labelled 'half-cell positions at the top of the excavation'. Note that the reading is about 1 volt and that the arrangement of resistors is similar to that of the 'normal soil' positions. This section has been constructed to show the reasons for the lower readings obtained when moving the electrode closer to a coating fault immediately before it has been exposed by excavation. Of course, once the fault is uncovered it has no connection to the electrolyte and the pipeline is effectively 'coated’ by the air. Move the positive connection of the digital meter progressively down the row of wires labelled 'moving half-cell down excavation', noting each reading. Note that the readings reduce as the resistance between the electrode and the pipeline reduces. This can be regarded as a different effect from that of a resistance in the measuring circuit. Here we are looking at the true voltage measurement and not an error due to the inefficiency of the meter. The potentials at each pole of the meter are of closer value due to the passage of current through the cathodic protection system. This is the improperly named 'IR drop in the soil'.

CIPS continued In the field this voltage is due to the resistance of the soil where the cathodic protection current passes onto the metal. Where there is no coating fault, this voltage is high, as demonstrated on Orac at the 'top of the excavation', which is out of the area of influence of the low resistance path to the pipeline. As the contact point moves closer to the lower value of resistance between itself and the pipeline the voltage between this point and the pipeline is reduced, as seen on the meter. Typical readings on Orac during this procedure are as follows:- Top of excavation volts Position volts Position volts Position volts Position volts Position volts Position volts Position volts Similar values will be obtained when moving a 'half-cell' electrode down the sides of an hole which is being excavated towards a coating fault. Indeed this is a method of guiding an excavation to the coating fault following a condition monitoring survey.

Contact with the pipeline. Moving the contact point along the pipeline has undetectable effect on the reading. During the massive voltage survey conducted by North Thames Gas, during the 1980's I was part of a team of technicians working for the Slough Office in the High Wycombe area. We were measuring voltages between the pipeline and an electrode which was stepped along the ground above the route of a coated, steel, high pressure gas pipeline. This was done at 10 meter steps while the impressed current cathodic protection was automatically switched on and off at the closest transformer rectifier. In order to carry out this survey we had to use a long thin wire (actually armature winding wire) as a connection to the pipeline through the normal cathodic protection test post facilities. These test posts were positioned at access points such as road crossings, and were up to 1 mile apart. We would connect the wire to the test post and unreel it from a spool which we carried, the other end of the wire being connected to the positive pole of the high resistance digital voltmeter. On one occasion I was instructed to chose two test posts approximately 1 mile apart and to take two voltage readings at each end. The thin wire was to be connected to the local test post and then to the test post one mile away. The readings showed that connecting to the pipeline one mile distant made no detectable difference to the voltage shown on the meter from that shown on the meter when connected locally. However, the reading was altered considerably by moving the location of the electrode a few meters. We carried out several tests to prove these facts and submitted a report, but got no feed back or further information.

This feature can be demonstrated on Orac by the following procedure. Connect the battery and adjust the output to achieve a voltage of 1.500v when the negative terminal of the meter is connected to test post position 1 and the positive connected to 'half-cell in normal earth'. Connect the negative terminal of the meter to the pipeline at test post position and note that the voltage has not changed. Connect the negative terminal of the meter to test post 3 position and note that the voltage has not changed. Calculate the total resistance along the 'pipeline' on Orac and you will find that it is the equivalent to the total resistance in the metal along several miles of large diameter steel pipeline. Movement of the position of the negative connection produces little or no change in the voltage but movement of the positive connection produces significant variations. This is the most significant fact in understanding monitoring of cathodic protection and the measurement of voltages in the study of the corrosion reaction. Using Orac can give an engineer a good concept of the electrical balances involved in the application of cathodic protection in the field.

Orac 1984