Frei verwendbar / © Siemens AG 2014. Alle Rechte vorbehalten.siemens.com/answers 5SU9 Residual Current Circuit Breakers with Overcurrent Protection SENTRON.

Slides:



Advertisements
Similar presentations
L.T Circuit Breakers.
Advertisements

Electrical Installation
Basic electrical circuitry & applications
M iniature circuit breakers to UL 489
Circuit Breakers and Busbars. Circuit Breakers Altech’s Circuit Breaker Line UL1077 (R-Series) UL508 (V-EA Series) UL489 (L-Series, AB-Series)
ABB SACE LPD RCDs System pro M compact ®. © ABB SACE RCDs: 3 families RCCB’sRCBO’sBlocks Earth leakage Indirect contact Overload Short circuit.
December, 2010 Vmax – Indoor vacuum circuit-breakers for Primary Distribution Product presentation 1VCP – Rev. D, en – Presentation –
Electric Currents Physics Department, New York City College of Technology.
Miniature Circuit Breakers (MCB) Multi 9
Domestic Installation: Switch Circuits
Current Electricity - Symbols Identify the Symbol.
Circuit Protection Electrical circuits require protection to prevent fire or electrocution in the event of a fault. There are two main types of circuit.
Electrical Engineering. A circuit is a combination of different components that allow electricity to flow through them. Each component serves its own.
SECTION 4 ELECTRIC MOTORS UNIT 19 MOTOR CONTROLS.
Electrical Fundamentals
Rocker Switches  Available in illuminated, Non-illuminated and Central illuminated version  Suitable for switching resistive and inductive load  Wide.
Standards LOW VOLTAGE Below or Equal to 1000V for AC & 1200V for DC
New ranges System proM compact® and Compact Home
Overcurrent protection devices
Electrical Installation Practice 2
Electrical Installation 2
MNS Sprint - A Market Driven Solution
Vadodara institute of engineering,kotambi NAME:NAFISKHANPATHAN(13ELEE181) BARIYA VIPUL(13ELEE182) PATEL AMIT(13ELEE180) BRANCH:EE-2 PPT OF EEE.
SARDAR PATEL INSTITUTE OF
Physics I Honors 1 Current and Circuits Circuits Schematics Use of Meters.
Moeller GmbH GB Leistungsschalter Protective note to rule DIN ISO is to be considered The new line of circuit breaker IZM ILS-P / W. Wagner July.
Welcome to Electric Dept. Rajkot Division. How MCB works.
© Siemens AG 2012 / All rights reserved. 5SM6 AFD Units – Advanced Preventative Fire Protection Comprehensive protection against fires caused by electricity.
Protection & Switchgear
Sales Training Outline 2006 Klaus Tum Product Manager PIN & Sleeve Devices 35 Royal Road Flemington, NJ
Residual Current Device Created by Clare,Huw and Conner.
ΜΕΣΑ ΔΙΑΚΟΠΗΣ, ΠΡΟΣΤΑΣΙΑΣ ΚΑΙ ΕΛΕΓΧΟΥ ΚΥΚΛΩΜΑΤΩΝ ΟΙΚΙΑΚΩΝ ΗΛΕΚΤΡΙΚΩΝ ΕΓΚΑΤΑΣΤΑΣΕΩΝ ΣΤΟΧΟΣ: Ο μαθητής να: αναγνωρίζει και να επιλέγει τα κατάλληλα Μέσα.
Main contacts closed – RED Colour with ON
Testing of Low Voltage Installations
Presentation Topic: Circuit Breakers Represented to: Dr. M. Riaz Khan Represented by: M. Mujahid.
5SV9 Residual Current Circuit Breakers with Overcurrent Protection
Electrical Safety "Shocking Statistics“  There are approximately 290 accidental electrocutions each year.  An additional 800 people die in fires caused.
MCB Connor, Sunny, Kia. What does it do? A circuit breaker is an automatically operated electrical switch designed to protect an electrical circuit from.
5SL4 10 kA / 5SL6 6 kA miniature circuit breakers
OEZ s.r.o. Quick and universal solution for your order Modeion 05/2012.
E Control Devices have a wide range of Latching Relays. The range of latching includes Relays, 16 Amp Latching Relays, 30Amp Latching Relays, 80 Amp Latching.
  The traditional molded-case circuit breaker uses electromechanical (thermal magnetic) trip units that may be fixed or interchangeable.  An MCCB provides.
Electrical Safety.
PROTECTION AGAINST INDIRECT CONTACT
Work Book / Text Book.
Unit 45: Circuits and components Dr
Projekt Anglicky v odborných předmětech, CZ.1.07/1.3.09/
3AH5 Vacuum Circuit-Breaker For Standard Applications
Different Types of Relays.
Principles & Applications
3AH5 Vacuum Circuit-Breaker For Standard Applications
ELECTRICAL INSTALLATION AND MAINTENANCE (EIM) 5 INSTALL ELECTRICAL PROTECTIVE DEVICES FOR DISTRIBUTION, POWER, LIGHTING, AUXILIARY, LIGHTNING PROTECTION.
Circuits and Circuit Elements
Engineering Project Cable Management.
ELECTRICAL POWER-II Electrical engineering sixth semester
Overcurrent Protection— Fuses and Circuit Breakers
Agenda Introduction of Protective Relays
The Safe Use of Electricity
3AH5 Vacuum Circuit-Breaker For Standard Applications
Electric Circuits.
Basic Electric 3 HVAC Electric Components
Presentation transcript:

Frei verwendbar / © Siemens AG Alle Rechte vorbehalten.siemens.com/answers 5SU9 Residual Current Circuit Breakers with Overcurrent Protection SENTRON

Frei verwendbar / © Siemens AG Alle Rechte vorbehalten. 5SU9 Residual Current Circuit Breakers with Overcurrent Protection Residual Current Operated Circuit Breakers (RCBOs) are a combination of an RCCB and MCB in a compact design for personnel, fire and line protection. For personnel protection and fire protection, the residual current part of the type AC trips in the event of sinusoidal AC residual currents, type A also trips in the event of pulsating DC residual currents. RCBOs with a rated residual current of maximum 30 mA are used for personnel, material and fire protection, as well as for protection against direct contact. The MCB part of the 5SU9 RCBOs protects lines against overload and short circuits and is available in characteristics B, C and D. RCBOs comprise one part for fault-current detection and one part for overcurrent detection. They are equipped with a delayed overload/time-dependent thermal release (thermal bimetal) for low overcurrents and with an instantaneous electromagnetic release for higher overload and short-circuit currents.

Frei verwendbar / © Siemens AG Alle Rechte vorbehalten. Residual Current Circuit Breakers with Overcurrent Protection Portfolio Overview 5SU9, 5SV9 (electronic, voltage dependant)

Frei verwendbar / © Siemens AG Alle Rechte vorbehalten. 5SU9 RCBOs Overview 5SU9 1+N solid N (5SU9.0.-.KK..) Rated current: 6A... 45A Rated switching capacity:6kA, 10kA acc. IEC MCB tripping characteristics: B, C Rated voltage: AC 230V RCD TypeType AC, Type A I∆n: 10mA, 30mA, 100mA, 300mA Poles: 1P+N (solid N) Switching cycles: > (electrical & mechanical) Ambient temperature range:-25°C to +45°C Dimensions (HxWxD):125mm x 18mm x 77mm Terminal conductor cross-sections: Solid and stranded wire: 0, mm² Finely stranded with end sleeve: 0, mm² Outgoing:0, mm² N- and FE wire length:600mm Environmental awareness:Compliance with RoHS Approvals & markings:CE Compliance with standards: IEC , IEC

Frei verwendbar / © Siemens AG Alle Rechte vorbehalten. 5SU9 RCBOs Overview 5SU9 solid N special voltage (5SU KX..) Rated current: 6A... 40A Rated switching capacity:10kA acc. IEC MCB tripping characteristics: C Rated voltage: AC 110V / 120V; 50/60Hz RCD TypeType A I∆n: 30mA Poles: 1P+N (solid N) Switching cycles: > (electrical & mechanical) Ambient temperature range:-25°C to +45°C Dimensions (HxWxD):125mm x 18mm x 77mm Terminal conductor cross-sections: Solid and stranded wire: 0, mm² Finely stranded with end sleeve: 0, mm² Outgoing:0, mm² N- and FE wire length:600mm Environmental awareness:Compliance with RoHS Approvals & markings:CE Compliance with standards: IEC , IEC

Frei verwendbar / © Siemens AG Alle Rechte vorbehalten. 5SU9 RCBOs Overview 5SU9 1+N switched N (5SU9.5.-.K...) Rated current: 6A... 63A Rated switching capacity:6kA, 10kA acc. IEC MCB tripping characteristics: C, D Rated voltage: AC 230V, AC 110V RCD TypeType AC, Type A I∆n: 10mA, 30mA Poles: 1P+N (switched N) Switching cycles: > (electrical & mechanical) Ambient temperature range:-25°C to +45°C Dimensions (HxWxD):90mm x 36mm x 77mm Terminal conductor cross-sections: Solid and stranded wire: 0, mm² Finely stranded with end sleeve: 0, mm² Environmental awareness:Compliance with RoHS Approvals & markings:CE Compliance with standards: IEC , IEC

Frei verwendbar / © Siemens AG Alle Rechte vorbehalten. 5SU9 RCBOs Dimensions – Symbols 5SU9.0.-.KK.. Dimensions Symbols / Connection diagram and lettering

Frei verwendbar / © Siemens AG Alle Rechte vorbehalten. 5SU9 RCBOs Dimensions – Symbols 5SU9.5.-.K... Dimensions Symbols / Connection diagram and lettering

Frei verwendbar / © Siemens AG Alle Rechte vorbehalten. 5SU9 RCBOs Terminals and busbar compatibility Terminal capacity Solid and stranded wire: 0, mm² Finely stranded with end sleeve: 0, mm² Outgoing:0, mm² Busbar compatibility 5ST36 fixed length busbar system 5ST37 busbar system suitable for cutting at desired lengths Example image depicting busbar capabilities, here shown at MCB By overlapping of fixed length busbars, quite boundless possiblilities for device combinations can be realized. Overlapping of busbars can also be used for conductor-crosssection increase up to 32mm² (by use of adequate busbars from the 10mm² and 16mm² portfolio) 5ST3601

Frei verwendbar / © Siemens AG Alle Rechte vorbehalten. 5SU9 RCBOs Additional Components Busbar systems for 5SU9.0.-.KK.. (RCBO 1+N solid N) 5ST37 busbar system, single-phase, 10mm², for MCB 1P or 5SU9 RCBO 1+N solid N, can be cut, with end caps 5ST360 busbar system, single-phase, for MCB 1P or 5SU9 RCBO 1+N solid N, can not be cut, fully insulated 10mm², for 2 MCBs or RCBOs 5SU9.0.-.KK.. : 5ST3600 (10 per pack) 10mm², for 6 MCBs or RCBOs 5SU9.0.-.KK.. : 5ST3601 (10 per pack) 10mm², for 12 RCBOs 5SU : 5ST3602 (10 per pack) 10mm², for 12 MCBs or RCBOs 5SU9.0.-.KK.. : 5ST3730 (1 per pack) 16mm², for 12 MCBs or RCBOs 5SU9.0.-.KK.. : 5ST3700 (1per pack) 16mm², for 2 MCBs or RCBOs 5SU9.0.-.KK.. : 5ST3630 (10 per pack) 16mm², for 6 MCBs or RCBOs 5SU9.0.-.KK.. : 5ST3631 (10 per pack) 16mm², for 12 MCBs or RCBOs 5SU9.0.-.KK.. : 5ST3632 (10 per pack)

Frei verwendbar / © Siemens AG Alle Rechte vorbehalten. 5SU9 RCBOs Additional Components Busbar systems for 5SU9.5.-.K... 5ST36 busbar system, four-phase, 10mm², for MCB 1P+N or 5SU9 RCBO 1+N switched N, can not be cut, fully insulated 10mm², for 6 MCBs 1P+N or RCBOs 5SU9.5.-.K... : 5ST3623 (10 per pack) 5ST36 busbar system, four-phase, 16mm², for MCB 1P+N or 5SU9 RCBO 1+N switched N, can not be cut, fully insulated 16mm², for 6 MCBs 1P+N or RCBOs 5SU9.5.-.K... : 5ST3653 (10 per pack)

Frei verwendbar / © Siemens AG Alle Rechte vorbehalten. 5SU9 RCBOs Additional Components Handle locking system for 5SU9 RCBOs Handle locking device, suitable for all padlocks from 3mm to 6mm:5ST3801 5SU9 RCBOs are lockable in ON and OFF position Padlock for 5ST3806 handle locking device:5ST3802

Frei verwendbar / © Siemens AG Alle Rechte vorbehalten. Residual Current Circuit Breakers with Overcurrent Protection Tripping characteristic type "B" For universal use in socket outlet and lighting circuits Tripping characteristic type "C" For lamp circuits and motor circuits with high starting currents

Frei verwendbar / © Siemens AG Alle Rechte vorbehalten. Residual Current Circuit Breakers with Overcurrent Protection Tripping characteristic type "D" For electrical circuits with strong pulse-generating equipmentsuch as transformers or solenoid valves.

Frei verwendbar / © Siemens AG Alle Rechte vorbehalten. Contact Page Peter Karl Product Manager IC LMV LP IEC P CP Siemensstrasse Regensburg Phone: +49 (941) Fax: +49 (941) Mobile: +49 (173) Answers for infrastructure and cities.