Distribution Solution. Distribution Solution - Topics Substation Automation Conventional vs New Technology RED 500 protection relays REJ, REU Multipurpose.

Slides:



Advertisements
Similar presentations
Distribution Automation Product News
Advertisements

Variable Frequency Drives Bypass Options
CL100D series DSP controlled Uninterruptible power supplies.
VAMP 300 IED functionality Feeder relay Motor relay
SIPROTEC 4 Distance Protection 7SA6 1 1.
 UK Power Networks. All rights reserved Distribution Network Visibility Low Carbon Networks Fund Tier 1 project UK Power Networks & PPA Energy Omer.
MIFII DIGITAL FEEDER PROTECTION A Cost Effective Protection Solution for Overcurrent Protection at Any Voltage Level GE Multilin
AC Inverter Drives 500 Series Product Range Overview 2000 AC Inverter Drives.
G GE Power Management DDS Integrated P&C System INTGRATED PROTECTION AND CONTROL SYSTEM DDS INTEGRATED PROTECTION INTEGRATED CONTROL.
LP-31 Series Uninterruptible Power Supply Product Management GE Consumer & Industrial Power Protection.
Protections from the technical point of view “What you always wanted to know about protections and were afraid to ask…” Petra Píclová Online training
EVD4 - The Smart eVolution Primary distribution circuit-breaker with integrated protection, control and sensors © ABB Group 15. April 2017 | Slide 1 1.
LP33 Series UPS kVA 400Vac/CE
FP5000 Refer to for the latest information on this constantly evolving productwww.eatonelectrical.com.
W650 Wind Generator Protection System
Megger - Substation overview product groups, 2600 products.
SYMAP-BC SYMAP-BC.
FireClass FC501. What’s FC501 ? An entry level Triple Circuit Single Loop addressable system featuring Intelli-Zone mapping An “out of the box” panel.
Static Relays Static relays are those in which the designed response is developed by electronic or magnetic means without mechanical motion. The designation.
M Family Industrial Systems 1 M Family relays provide economical & reliable digital protection, metering, control and monitoring in an integrated package.
© ABB Group June 10, 2015 | Slide 1 1MRS A self healing power system for the accurate fault location and zone concept T&D Smart Grids Europe 2012.
Generator Protection. Amount of Protection Rated power of the generator Ratio of its capacity to the total capacity of the system Configuration of the.
1 PCA2 On-load Protection Condition Analyser. 2 PCA2 online testing concept Concept introduction: PCA2 is a new system test approach intended to save.
Industrial Systems Introducing the L90 Universal Relay Advanced transmission line protection and control High-speed current differential protection for.
Make the most of your energy December 2008 PowerLogic Enercept Submetering ….when space is at a premium PowerLogic® Enercept Meter.
MIG II DIGITAL FEEDER PROTECTION
Product choice offered by ABB Oy, Distribution Automation
Interconnect Protection of Dispersed Generators
G650 Generator Protection & Control System
LP Series 11/31T - Uninterruptible Power Supply Product Management GE Consumer & Industrial Power Protection.
4/21/2017 MicroSCADA Pro DMS 600 Matti Kärenlampi FISUB/Österbacka.
SFT 2841 IN CONNECTED MODE Prepare setting files.
Electrical Distribution Training
Medium Voltage products Energy reliability & revenue improvement Speaker: Jean-Yves Pocthier - Schneider Electric France Technical solution for improvement.
Unit 5 CONTROL CENTERS AND POWER SYSTEM SECURITY.
MicroSCADA Pro Ortviken upgrade & Crimea Wind Power Plant
Power Quality Enhancements for IEC Winston CHUA Ywee Ming South-East Asia Business Development Manager Energy Management Solution September 19, 2011.
AQ 100 Series Arc Flash Protection System. Characteristics of arc protection Speed, no intentional delays Sensitive, current set-points just above loads.
MV Network Operation and Control Barcelona May 2003 Eugenio Di Marino Italy Session 3 Alpha 1 Block 1.
3-Phase Submersible Motor Control
Power Plant Construction and QA/QC Section 4.4 – In-Plant Electrical Distribution Engineering Technology Division.
YASKAWA VS-606 V7 COMPACT VECTOR - CONTROLLED INVERTER FOR GENERAL USE 230V (Single-Phase).1Kw ~ 3.7Kw (.13HP ~ 5HP) 230V (Three-Phase).1Kw ~ 7.5Kw (.13HP.
Protection & Switchgear
SmartMQn Motor Horner APG, LLC September 9, 2008.
Franklin Electric - The Company You Trust Deep Down Provides The Ultimate Protection for Your Pump & Motor! Franklin SubMonitor.
NERC Lessons Learned Summary LLs Published in September 2015.
Evolution and Prospects of Relay Protection and Automation Systems Evolution and Prospects of Relay Protection and Automation Systems Moderator: Janez.
1 Industrial Systems BUS2000 Busbar Differential Protection System Differential overcurrent system with percentage restraint protection.
Survey of Smart Grid concepts and demonstrations Smart substation Ari Nikander.
MiCOM P125 P126 & P127 27th, Aug 2007 Lakshmikanthan Balaji Application Engineer.
Interconnect Protection of Dispersed Generators
SCADA for Remote Industrial Plant
GROUND-FAULT GROUND-CHECK MONITOR
FEEDER PROTECTION UNIT
MicroSCADA Pro Complete Scalability
PowerValue 11/31 T Sales Presentation
Peter Erning, PSP-T11, Power Gen 2010
Protection Philosophy
METER SPECIFICATIONS.
PowerLogic™ offer for the basic metering market
Meet demanding customer expectations with the right energy meter
Biosco: MV/LV prefabricated substations IEC Presentation of the standard Safety is a choice.
Presentation transcript:

Distribution Solution

Distribution Solution - Topics Substation Automation Conventional vs New Technology RED 500 protection relays REJ, REU Multipurpose Relays REX521 Feeder Protection REF54x Feeder Terminal REM54x Machine Terminal MicroSCADA Network and Control System Station Automation (SCS) Network Control System (NCS) Summary

Distribution Solution - Substation Automation Conventional Technology control panel, separate relay room, connectivity through hardwiring. New Technology local control, multifunction relays, connectivity through serial communication.

Distribution Solution - Example of automation Cost benefits for a new substation construction: conventional substation design compared with automated substation design. Configuration: 6 x 138 kV Circuit breakers, 1 1/2 CB arrangement 1 x 138/15 kV Transformer 2 x 6 lineups of 15 kV metalclad distribution switchgear

Distribution Solution - Automation vs Conventional Estimated benefitsQty cost / unitTotal control panels ,000 relay panels ,000 metering relays ,600 feeder relays ,000 reduced conduit (ft) ,000 reduced wiring (ft) ,000 bulding size m ,400 reduced RTU- 1 48, ,000 fault recorder- 1 29, ,000 reduced seq. event rec.- 4 7, ,000 reduced annunciator- 2 3,800- 7,600 Total - 336,600 Appr. Price for new installation150, ,000 Savings 86, ,000 Source: Newton & Evans report

Distribution Solution - Multipurpose Relays Voltage relays: REU 523 & REU 513 Overcurrent & earth-fault relays: REJ 525 & REJ 515 Overcurrent relays: REJ 523 & REJ 513 Earth-fault relays: REJ 521 & REJ 511 Directional earth-fault relays: REJ 527 & REJ 517 Multipurpose protection relay series

Distribution Solution - Multipurpose Relays Features A wide range of protection functions Wide and accurate numerical settings with perfect long-time stability Two sets of relay settings available Recorded and time-stamped data of the latest 5 events Event code buffer of the latest 60 events Disturbance recording function for fault analysis Output relay functions freely configurable for tripping and signalling Circuit-breaker failure protection unit

Distribution Solution - Multipurpose Relays Features Binary input for blocking, external resetting, triggering and selection of setting group Optical serial interface on the front panel for communication with portable computer Powerful and easy-to-use software tools for relay setting High system reliability and availability due to continuous hardware and software self-supervision High immunity to electrical and electromagnetic interference Relay case with a degree of protection according to IP 54 Rated frequency user-selectable 50/60 Hz CE marking according to the EC directive for EMC

Distribution Solution - REX521 Feeder Protection Easy to use - ready made configurations = local adaptations are not needed Wide protection functionality - covering the most essential protection functions Condition monitoring functions - for continuos supervision Control functions - local or remote Measurements Connectivity - for remote control and monitoring Easy to integrate in systems through communication protocols Easy to order The supervision of your network will be enhanced by using REX 521

Distribution Solution - REX521 Feeder Protection Functionality Protections 3 stages non directional OC 3 stages directional or non directional EF Phase discontinuity protection Thermal protection for cables Circuit breaker failure protection Autorecloser Directional OC Over / under voltage Residual over voltage Frequency Syncrocheck Measurements 3-phase current Earth fault current Neutral current Disturbance recorder Harmonics up to 13th 3-phase voltage Active & reactive power Active & reactive energy) Frequency & cos Ø

Distribution Solution - REX521 Feeder Protection Functionality Control Control of one circuit breaker Indication of 3 objects Pre-programmed interlocking conditions Condition Monitoring Self supervision (IRF) Trip circuit supervision Circuit-breaker wear Phase current supervision (MCS 3I) Phase voltage supervision (MCS 3U) Communication SPA, LON and IEC103 protocol Set values, measured values, registered values / events, uploading of disturbance recorder data, control, etc. available trough communication Easy to use Measured values shown as primary values The settings are made in primary values Easy menu navigation MMI in several languages

Distribution Solution - REF54x Feeder Terminal Everything in one box

Distribution Solution - REF54x Feeder Terminal Full range of protection, measuring, control and supervision functions Large amount of generic functions Freely drawable mimic view Freely programmable alarm indications Freely configurable function button Application-specific functionality Flexibility

Distribution Solution - REF54x Feeder Terminal Protection Functions Auto-reclosing (5 shots) Phase discontinuity Non-directional earth-fault I, h, i Directional earth-fault l, h, i Non-directional overcurrent l, h, i Directional overcurrent l, h, i Under/overfrequency Transformer inrush and motor start-up current detector Overvoltage l, h Undervoltage l, h Residual overvoltage l, h, i Synchro/voltage-check Thermal overload for cables

Distribution Solution - REM54x Machine Terminal Innovative total solution for rotating electrical machines Motor Protection Optimized protection functionality for asynchronous motor application Generator Protection Wide range of protection functions covering also generators and synchronous motors

Distribution Solution - REM54x Machine Terminal Motor protection Motor start-up supervision (48,14, 66) Thermal overload (49) Unbalance (46) Under current (37) Reverse phase rotation (46R) Over current and short circuit (50/51) High-impedance based /Flux-balance principle based 3-phase differential protection (87M) Earth fault, non-directional (51N) and directional (67N) RTD/analogue inputs Analogue outputs

Distribution Solution - REM54x Machine Terminal Generator protection Over current and short circuit (50/51) Voltage dependent over current (51V) Underimpedance protection (21G) Fuse failure supervision (60) Stabilized differential protection High-impedance based /Flux-balance principle based 3-phase differential protection (87G) Earth fault, non-directional (51N) and directional (67N) Residual over voltage (59N) Over and under voltage (59, 27) Positive/negative phase sequence voltage protection (27,47,59) Over current and short circuit (50/51) Overexcitation protection (24) Under excitation (40) Thermal overload (49) Unbalanced load, NPS (46) Reverse and forward power (32) Abnormal frequency including df/dt (81O/81U)

Distribution Solution - MicroSCADA MicroSCADA, the ABB solution for control and automation of power distribution for utilities and industry.

Distribution Solution - MicroSCADA Substation automation (SCS) Protection Monitoring and control Communication with NCC Power quality measurements Time synchronization Interlocking Metering MV & HV

Distribution Solution - MicroSCADA Network control system (NCS)

Distribution Solution - MicroSCADA - Based on industry standards Windows NT operating system Standard hardware - Open Wide range of communication protocols Interface to third-party SW and databases - Database Logical name (LN) Index /LN Address space for RTUs High performance, unique functionality Advanced process database, data- logging functions and timing functions Unique high-level programming language for the application engineer User authorization mechanism - Scalability From mobile lap-top to hot stand-by - Continuity Compatibility between program versions Consistency between application levels Upgradable. Continuity in development. - High system availability based on Verified SW development Rigorous test procedure for new releases (PVC) Coordination of system releases - Built for local engineering Easy engineering using library modules Established support concepts - Connection to office programs Reports to Excel, etc. MicroSCADA technology highlights

Distribution Solution - Summary ABB advantages Cost efficiency Ready made solutions available - local adaptations not needed By automating your substation you will be able to reduce hardware and installation time Compact design and size for easy installation Freedom of choice A wide range of products meeting all your needs and requirements Added value Products at all levels of automation, from stand-alone to a complete solution We have The experience and the know-how Improve efficiency through data information and prevent accidents from happening!