Electrical Events Involving Look-Alike Equipment within the DOE Complex.

Slides:



Advertisements
Similar presentations
Subcontractor Electrical Safety & NFPA 70E
Advertisements

Hazards Of Electricity
LIMITED APPROACH BOUNDARY
DOE Electrical Assessment of C-AD: Inaccurate Electrical Panel Schedules Missing Knockouts Panel Modifications Picture of the Week Collider-Accelerator.
EFCOG Electrical Improvement Project Electrical Hazards Awareness Briefing Excavation and Trenching Module 5.
Murray State University
Richard (Rick) Elwell Senior Operations and Safety Instructor and Consultant
1S25 Arc Fault Monitor. 1S25 Arc Fault Monitor 1S25 Arc Fault Monitor Electrical arc short circuits in metal clad switchgear may occur for many different.
 ELECTRICAL SAFETY Gerald P. Robinson Jr., P.E. – Hatch Mott MacDonald.
Arc Flash: Electrical Safety in the Workplace CCIA Safety Committee SAFETY ROUNDTABLE April 10, 2012 sm 1.
Finding a Common Thread… Presented by: Paul Pinto, National Accounts, Protective Apparel ARC Flash Protection, 70E and PPE.
This presentation is for illustrative and general educational purposes only and is not intended to substitute for the official MSHA Investigation Report.
CHREID 2008 ELECTRICAL SAFETY Introduction and Overview of Safety Clayton H. Reid September, 2010.
1 Hazardous Energy Module 5. 2Objectives After this module you should be able to – identify the most common energy hazards – take the necessary steps.
ELECTRICAL SAFETY FOR RADIOLOGICAL CONTROL TECHNICIANS
ELECTRICAL SAFETY / E N V I R O N H & S T R A I N I N G P R O G R A M ELECTRICAL SAFETY OSHA requires that electrical equipment be approved for use and.
When working on or near electricity or electrical equipment you must be trained in & use Electrical Safety Related Work Practices NFPA.
ARC FLASH ANALYSIS.
Construction Training
Slide 1 UNCLASSIFIED Breaker Operation Arc Flash Breakout Group EFCOG Electrical Safety Workshop – July 18, 2014.
Take 5 for Safety E. Lessard May 5, LANL Electrical Accident May 3, 2015  LOS ALAMOS, N.M. —Los Alamos National Laboratory workers were injured.
Electrical Safety Training
Utilizing Only Qualified Persons for Electrical Work can Reduce Risk Presented by: Dennis K. Neitzel, CPE Director Emeritus AVO Training Institute, Inc.
“Standard for Electrical Safety in the Workplace”
What is Arc Flash? Arc flash is a short circuit through air that flashes over from one exposed live conductor to another conductor or to ground. Arc flash.
Controlling Hazardous Energy
Danger Tags and Locks Picture of the Week Collider-Accelerator Department Take 5 for Safety.
This presentation is for illustrative and general educational purposes only and is not intended to substitute for the official MSHA Investigation Report.
2 Instructor Training MPTT Flow Loop System VLP-TRN-MPTT.
NWACC Business & Industry Workforce Development Institute J- 1 CONTROL OF HAZARDOUS ENERGY (LOCKOUT/TAGOUT) FOR GENERAL INDUSTRY.
CONTROL OF HAZARDOUS ENERGY LOCKOUT/ TAGOUT PROGRAM.
Establishing an Electrically Safe Work Condition May is Electrical Safety Month Training A product of the EFCOG Electrical Safety Task Group.
Proposed Revision to ORPS Criteria for Hazardous Electrical Energy Mike Hicks, DOE, Idaho Lloyd Gordon, LANL November 3, 2009.
© Evaluating Electrical Risk Factors Module 3.
Preliminary Analysis Results of Electrical Shocks Reported in the Occurrence Reporting and Processing System (2008 – August 2012) October 2,
Turbine Crane CRANES TURBINE NEA39. Turbine Crane PLANT STATUS! PV Daily Status Report.
Copyright © 2011 Rockwell Automation, Inc. All rights reserved. CENTERLINE 2100 Motor Control Center - SecureConnect™ September 1, 2011.
© Recognizing Electrical Risk Factors Module 2.
Take 5 for Safety E. Lessard May 12, Arc Flash Event at INL Involving Situational Awareness Barrier  On April 15, 2015, Idaho National Lab workers.
NFPA 70E Electrical Safety in the Workplace. Objectives What NFPA 70E covers Understand Arc Flash, Incident Energy, & Flash Protection Boundary Standards,
Electrical Safety and Electrical Safe Work Practices EHS Course #525 Reference EHS Electrical Safety Procedure
MNM Fatal Electrical Accident Electrical Accident October 10, 2010 (Oklahoma) October 10, 2010 (Oklahoma) Granite Operation Granite Operation Contract.
Isolation Lock-Out Room Johns River Quarry Site Contact: Blake Ardrey, Quarry Manager, BCM, Johns River Quarry Phone:
First Draft Language (B) Service Equipment. In addition to the requirements in (A), service equipment shall contain the following information: (1)
Electrical hazard Awareness. What does hazard mean? Hazard means: any potential or actual threat to the wellbeing of people, machinery or environment.
Electrical Safety, Subpart K
MNM Fatal Electrical Electrical November 18, 2013 (Kentucky) November 18, 2013 (Kentucky) Crushed Stone Mine Crushed Stone Mine Contract Electrician.
NCSX NCSX Safety Meeting The Arc Flash Event at SLAC – How Should We Respond? Wayne Reiersen 20 January 2005.
Core Drilling into an Energized 13.2 kv Manhole Near Miss Los Alamos National Laboratory, TA-55 Plutonium Facility Presented by Dan Carter, Facility Representative.
An introduction to… Lockout Tagout. Aim Every year thousands of workers get killed or injured while performing repairs or maintenance on industrial equipment.
Electrical Work Practices City of Council Bluffs Presented by: SilverStone Group © 2012 Zywave, Inc. All rights reserved.
Chicago Area Facilities (CAF) Electrical Safety Program.
Summary of Los Alamos TA-53 Arc-Flash Event John Anderson Jr. 13 August 2015.
Control of Hazardous Energy 29 CFR Lockout/Tagout Basics? Regulatory requirements Energy Isolation Devices Energy Sources Affected, Authorized.
CONTROL OF HAZARDOUS ENERGY (LOCKOUT/TRYOUT). LOCKOUT/TRYOUT The OSHA Standard for the Control of Hazardous Energy (Lockout/Tryout) 29 CFR covers.
The Dangers of Look-Alike Equipment EFCOG-ESTG Electrical Safety Month May 2016.
San Francisco Electricians. Why Do You Need to Call an Electrician? Most of us have studied that one subject about circuits, electricity, and electrons.
What is Arc Flash? Electrical arc flash and arc blasts release dangerous levels of heat energy, fire , molten materials, vaporized solids that can be inhaled,
Energy Control (Lockout/Tagout)
Maintenance Error Results in Bypassing Enclosure Electrical Lock Out Tag Out John E. Anderson Jr. Energy Facility Contractors Group Electrical Safety.
Review of Electrical Safety 2015
Chapter 9 Safety Permit Systems
Contractor Injury – Electrical Arc Flash Washington Site
Controlling the Beast: Controlling Hazardous Energy via Lock-out Tag-out (LOTO) and Check Energy is what drives the world, powers our industries and keeps.
Murray State University
This presentation is for illustrative and general educational purposes only and is not intended to substitute for the official MSHA Investigation Report.
Control of Hazardous Energy
Electrical Hazards By Kory Hildebrand.
Isolation Procedure Topic 2, Unit 6.
Presentation transcript:

Electrical Events Involving Look-Alike Equipment within the DOE Complex

Introduction Design and placement of electrical equipment for utilization purposes may require multiple sections of the same design to be installed. Multiple sections are typically the same size, color, shape, and configuration making them difficult to distinguish from one another. Multiple installations of similar equipment such as variable frequency drive cabinets, motors, disconnects all in close proximity has caused errors to occur in industry and the DOE complex. Errors involving similar or look-alike equipment have led to equipment damage and personal injury.

Idaho National Laboratory Electrician in support of an air compressor upgrade accesses an energized potential transformer cabinet resulting in a severe shock and minor equipment damage. Unlike the picture - the back of the switchgear was not labeled.

East Tennessee Technology Park Electrician enters wrong cabinet to disconnect transformer links using an open end wrench. Nearing the energized bus the worker realizes the equipment is energized and drops the wrench initiating an arc flash. Worker receives minor injuries and equipment is damaged.

Hanford Site Electricians locked and tagged pump #4 but electrically disconnect pump #1. Pump #1 circuit breaker was open but not locked and tagged.

Idaho National Laboratory Electrician disconnects wrong 480 Vac motor. Several motors of the same type and design located in same area. Classified as a near miss because the motor could have started automatically if conditions for start existed. Example only, not actual area of incident

Thomas Jefferson National Accelerator Laboratory Subcontractor incorrectly identifies and cuts energized 15 kV cable. The cable was remotely cut and no personnel were exposed to hazardous energy.

Los Alamos National Laboratory Electrician enters 13.8 kV switchgear to perform cleaning activities and initiates an arc flash. The worker entered a cubicle that was no longer controlled by the clearance. The arc flash injures the worker and damages equipment.

Summary Poor verification practices and flawed assumptions when working with look-alike equipment has lead to numerous errors resulting in personal injuries and equipment damage at DOE complex facilities. NFPA 70E addresses look alike equipment but does not describe how to eliminate or minimize errors involving look-alike equipment. It is up to the DOE complex facilities to implement policies, and procedures to mitigate the hazards of look-alike equipment. The Energy Facility Contractor Operating Group (EFCOG) electrical safety task group has been tasked to develop a best practice to guide facilities in their efforts to develop controls for look-alike equipment.