A Capillary Waveguide Biosensor for Marine Microbial Process Studies Kemp, P.F., Aller, J.Y., Dhadwal, H.S., Dantzler, M.M.

Slides:



Advertisements
Similar presentations
Experiment Design for Affymetrix Microarray.
Advertisements

Surface Plasmon Resonance Biosensors
REAL TIME PCR ………A step forward in medicine
Practical molecular biology
RNA-Seq An alternative to microarray. Steps Grow cells or isolate tissue (brain, liver, muscle) Isolate total RNA Isolate mRNA from total RNA (poly.
Tools for Molecular Biology Amplification. The PCR reaction is a way to quickly drive the exponential amplification of a small piece of DNA. PCR is a.
Analysis of gene expression by real-time PCR RBCS3 and Cab-1b transcript quantitation by real time PCR.
Jump to first page STATISTICAL INFERENCE Statistical Inference uses sample data and statistical procedures to: n Estimate population parameters; or n Test.
Charge-Based Biosensor Using Carbon Nanotube Transistors Array Presenter: Jui-Ping Chiang.
DNA Microarray: A Recombinant DNA Method. Basic Steps to Microarray: Obtain cells with genes that are needed for analysis. Isolate the mRNA using extraction.
Error Propagation. Uncertainty Uncertainty reflects the knowledge that a measured value is related to the mean. Probable error is the range from the mean.
Microarray analysis Golan Yona ( original version by David Lin )
Assays Molecular Diagnostics CSULA. What’s a molecular diagnostic assay? n A laboratory test for the presence or absence of a particular type of molecule.
RNA-Seq An alternative to microarray. Steps Grow cells or isolate tissue (brain, liver, muscle) Isolate total RNA Isolate mRNA from total RNA (poly.
Introduce to Microarray
Assigning Numbers to the Arrows Parameterizing a Gene Regulation Network by using Accurate Expression Kinetics.
Principles and Important Considerations
and analysis of gene transcription
Analysis of microarray data
Microarray Preprocessing
Real-Time PCR (Quantitative PCR)
Laboratory Training for Field Epidemiologists Polymerase Chain Reaction Investigation strategies and methods May 2007.
Variants of PCR Lecture 4
Mariya Smit and Holly Simon
Biotechnology. DNA technology DNA diagnostics DNA therapy.
6.3 Advanced Molecular Biological Techniques 1. Polymerase chain reaction (PCR) 2. Restriction fragment length polymorphism (RFLP) 3. DNA sequencing.
© Copyright 2009 by the American Association for Clinical Chemistry Mediator Probe PCR: A Novel Approach for Detection of Real-Time PCR Based on Label-Free.
Quantification of RNA by real-time PCR
Applying statistical tests to microarray data. Introduction to filtering Recall- Filtering is the process of deciding which genes in a microarray experiment.
Intro to Microarray Analysis Courtesy of Professor Dan Nettleton Iowa State University (with some edits)
Blotting techniques are based Complementarity and Hybridization Blotting techniques are used to answer questions like oHow do we find genes of interest.
Gene expression. The information encoded in a gene is converted into a protein  The genetic information is made available to the cell Phases of gene.
Northern blotting & mRNA detection by qPCR - part 2.
Deciphering the structure and function of complex microbial communities is a central theme in microbial ecology.
Genomics I: The Transcriptome RNA Expression Analysis Determining genomewide RNA expression levels.
Biogeochemical Cycling and Introductory Microbial Ecology
6.3 Advanced Molecular Biological Techniques 1. Polymerase chain reaction (PCR) 2. Restriction fragment length polymorphism (RFLP) 3. DNA sequencing.
Lecturer: David. * Reverse transcription PCR * Used to detect RNA levels * RNA is converted to cDNA by reverse transcriptase * Then it is amplified.
Biotech. Cloning a mammal PCR This is the polymerase chain reaction. It is a technique to multiply a sample of DNA many times in a short period of time.
DNA BIOSENSORS Hybridization indicator (bacteria , virus , genetic inherited diseases) Trace measurements of pollutants (intercalators,
PCR With PCR it is possible to amplify a single piece of DNA, or a very small number of pieces of DNA, over many cycles, generating millions of copies.
Online Counseling Resource YCMOU ELearning Drive… School of Architecture, Science and Technology Yashwantrao Chavan Maharashtra Open University, Nashik.
Genomics I: The Transcriptome RNA Expression Analysis Determining genomewide RNA expression levels.
Statistical Analysis for Expression Experiments Heather Adams BeeSpace Doctoral Forum Thursday May 21, 2009.
The Polymerase Chain Reaction (PCR)
Green with envy?? Jelly fish “GFP” Transformed vertebrates.
 Types of STR markers- 5 types based on sequence  STR allele nomenclature  Allelic ladder  Serological methods of identity profiling  Identity profiling.
Kevin Chen.  A method of amplifying or copying DNA fragments.
Chapter 13: DNA Quantitation.  Determining the amount of DNA is a sample is essential  A narrow concentration range is required for PCR  Must use human-specific.
HRM Assay and Optimization 1. DNA Quality 2. Amplicon LengthAmplicon  lengths of 100–300 bp 3. Primer Selection 4. Dye Selection 5. MgCl2 Concentration.
Detecting DNA with DNA probes arrays. DNA sequences can be detected by DNA probes and arrays (= collection of microscopic DNA spots attached to a solid.
Neethu Xavier St. Alberts College Cochin, India Microcantilever Biosensors: Making Sensors Reliable.
Enzyme-linked immunosorbent assay (ELISA)
Chemiluminecent microparticle)) immunoassay
Chemiluminecent microparticle MEIA)) immunoassay
Gel electrophoresis analysis Automated DNA analyzer.
Nucleic acid-based methods (I)
The Basics of cDNA Microarray Technology
Fluorescent In Situ Hybridization (FISH) Assay
SOUTHERN BLOTTING Ali Zaeri Medical Genetics and diagnostic lab Lab 5.
Introduction to cDNA Microarray Technology
(vary time, physiological state, disease, ...)
Nucleic acid-based methods (I)
A Novel Technology for Multiplex Gene Expression Analysis Directly from Whole Blood Samples Stabilized at Ambient Temperature Using an RNA-Stabilizing.
BIOSENSOR.
Interplay of Troponin- and Myosin-Based Pathways of Calcium Activation in Skeletal and Cardiac Muscle: The Use of W7 as an Inhibitor of Thin Filament.
A DNA Computing Readout Operation Structure-Specific Cleavage
Verigene solid-phase microarray.
RealTime-PCR.
Principles of Quantitative PCR
Presentation transcript:

A Capillary Waveguide Biosensor for Marine Microbial Process Studies Kemp, P.F., Aller, J.Y., Dhadwal, H.S., Dantzler, M.M.

What is a biosensor? A biosensor is an instrument that couples a biological material to a transducer. A biosensor is an instrument that couples a biological material to a transducer. The transducer converts a change in the biological material into a measurable response. The transducer converts a change in the biological material into a measurable response.

Optical Hybridization Biosensors A monolayer coating of single-stranded DNA (probe) is bound at one end to the surface of an optical waveguide (e.g. an optical fiber) A monolayer coating of single-stranded DNA (probe) is bound at one end to the surface of an optical waveguide (e.g. an optical fiber) Hybridization of target RNA or DNA to the probe DNA induces a response (e.g. fluorescence) Hybridization of target RNA or DNA to the probe DNA induces a response (e.g. fluorescence) Hybridization biosensors can be used to detect the presence, abundance, and activity (growth, gene expression) of targeted microorganisms. Hybridization biosensors can be used to detect the presence, abundance, and activity (growth, gene expression) of targeted microorganisms.

Design of Capillary Waveguide Biosensors Harbans Dhadwal, Paul Kemp, Josephine Aller and Megan Dantzler

The measurement cycle consists of a series of hybridization reactions (signal) separated by denaturing reactions (background). Measurements are confounded by: power fluctuations, power fluctuations, tube-to-tube variations, tube-to-tube variations, hybridization time, hybridization time, target concentration. target concentration.

Power fluctuations: Target signal and background co-vary with power.

Tube-tube variations: The response of different sensor tubes to a given concentration of target varies, probably because of differences in probe coatings.

Time versus concentration: The time required to develop a maximum signal varies with target concentration. Time versus concentration: The time required to develop a maximum signal varies with target concentration.

What really happens To measure and compare concentrations, use the initial slope in a brief hybridization.

Uncorrected target and background responses

Signal = Target/ background response (correcting for variations in power)

Signal = Target/Background, corrected for tube-to-tube variations. Sensor response is very repeatable.

After correction, 95% confidence intervals for triplicate measurements are ±6%.After correction, 95% confidence intervals for triplicate measurements are ±6%. A small increase in signal above background is sufficient to detect target sequences.A small increase in signal above background is sufficient to detect target sequences. The lowest concentration we have tested to date is 31 pg DNA/mL.The lowest concentration we have tested to date is 31 pg DNA/mL. Another example Raw data Corrected data

At 31 pg DNA/ml, signal is measurable after 5 minutes. At 31 pg DNA/ml, signal is measurable after 5 minutes.

Concentration can be estimated from the initial slope of the hybridization signal.

What’s next? Real world tests are underway. We are evaluating the abundance of alpha- Proteobacteria in deep water, mid water, subsurface, surface microlayer, and aerosol samples. Real world tests are underway. We are evaluating the abundance of alpha- Proteobacteria in deep water, mid water, subsurface, surface microlayer, and aerosol samples. We are working on procedures for estimating target concentration from initial slope of the hybridization signal. We are working on procedures for estimating target concentration from initial slope of the hybridization signal. We are testing alternative detection protocols, focusing on a capture probe/detection probe strategy that allows for multiple fluorochrome labeling and enhanced signals. We are testing alternative detection protocols, focusing on a capture probe/detection probe strategy that allows for multiple fluorochrome labeling and enhanced signals.

With thanks to: NSF OCE Optical Biosensor for Marine Microbial Process Studies: Development Phase II. (P.F. Kemp, J.Y. Aller, and H.S. Dhadwal)