Development of the X-ray Detectors for XTP Cao Xue-lei Institute of High Energy Physics, CAS 2014.02.21 IHEP, Beijing.

Slides:



Advertisements
Similar presentations
The group is developing readout electronics for initial use with the prototype test-stand at Fermilab. This work will contribute towards the design and.
Advertisements

Sci-Fi tracker for IT replacement 1 Lausanne 9. December 2010.
Technical Board, 12 July 2005Børge Svane Nielsen, NBI1 Status of the FMD Børge Svane Nielsen Niels Bohr Institute.
Outline May 10-15, 2014 Warrenton Progress of HXMT Science Ground Segment: Calibration and Background analysis Zhang Juan , on behalf of HXMT.
CADMIUM ZINC TELLURIDE (CZT) IMAGER INTRODUCTION : 1.SCIENTIFIC REQUIRMENT 2. DETECTORS USED IN IMAGER 3. ELECTRICAL CIRCUITS (FRONT END ELECTRONICSUSED)
*Shuji Maeo 1,2, Takayuki Yanagida 1, Yuui Yokota 1 and Akira Yoshikawa 1,3 1 Division of Physical Process Design, Institute of Multidisciplinary Research.
Science Specification Table 12 keV keV for neutral particles 40.5 cm 2 image plane Electronic Noise 3 keV FWHM Proton Dead Layer
Shu Zhang (on behalf of the HXMT team) Institute of High Energy Physics, Chinese Academy of Science The current status of HXMT and its calibrations.
Xiaodong Wang ( 王晓冬 ) School of Nuclear Science and Technology Lanzhou University, Lanzhou, China MPGD activities at Lanzhou University July 5, 2013.
X-ray Timing and Polarization mission & instrumentation DONG Yongwei Center for Particle Astrophysics Institute of High Energy Physics, Chinese Academy.
Development of Readout ASIC for FPCCD Vertex Detector 01 October 2009 Kennosuke.Itagaki Tohoku University.
Calibration, simulation and test-beam characterisation of Timepix hybrid-pixel readout assemblies with ultra-thin sensors International Workshop on Future.
Report on SiPM Tests SiPM as a alternative photo detector to replace PMT. Qauntify basic characteristics Measure Energy, Timing resolution Develop simulation.
Development of Tracking Detector with GEM Kunihiro Fujita RCNP, Osaka Univ. Yasuhiro Sakemi CYRIC, Tohoku Univ. Masaharu Nomachi Dep. of Phys., Osaka Univ.
CZT Imager for ASTROSAT CONFIGURATION. CZT Module.
The High Resolution Array The High Resolution Array is a detector designed to detect and identify light charged particles like protons, deuterium, triton,
THE FAST X-RAY MONITOR (FXM) BASED ON YAP:CE SCINTILLATOR (YTTRIUM ALUMINUM PEROVSKITE ACTIVATED BY CERIUM) FOR THE “CORONAS-PHOTON” SATELLITE PROJECT.
Fully depleted MAPS: Pegasus and MIMOSA 33 Maciej Kachel, Wojciech Duliński PICSEL group, IPHC Strasbourg 1 For low energy X-ray applications.
11 th iWoRiD, Prague, Czech Republic Low-power Wide-dynamic-range Readout System for a 64-channel Multi-anode PMT of a Scintillation Gamma Camera Satoru.
Performance of a 128 Channel counting mode ASIC for direct X-ray imaging A 128 channel counting ASIC has been developed for direct X-ray imaging purposes.
Peter, Wieczorek - EE Low Noise Charge Sensitive Preamplifier Development for the PANDA Calorimeter Design and Measurements of the APFEL - Chip.
Self triggered readout of GEM in CBM J. Saini VECC, Kolkata.
1 Development of the input circuit for GOSSIP vertex detector in 0.13 μm CMOS technology. Vladimir Gromov, Ruud Kluit, Harry van der Graaf. NIKHEF, Amsterdam,
Beam diagnostics in the beamlines
The ALICE Forward Multiplicity Detector Kristján Gulbrandsen Niels Bohr Institute for the ALICE Collaboration.
Fine Pixel CCD for ILC Vertex Detector ‘08 7/31 Y. Takubo (Tohoku U.) for ILC-FPCCD vertex group ILC vertex detector Fine Pixel CCD (FPCCD) Test-sample.
Development of CCDs for the SXI We have developed 2 different types of CCDs for the SXI in parallel.. *Advantage =>They are successfully employed for current.
Pixellated CZT high-energy X-ray instrument
65 nm CMOS analog front-end for pixel detectors at the HL-LHC
JRA-1 ISRSI Consortium Meeting Perugia, INAF/IASF (BO,PA)
Design for Wide FOV Cherenkov telescope upgrading THE 2 nd WORKSHOP OF IHEP Shoushan Zhang Institute of High Energy Physics.
HT-7 A new soft x-ray PHA diagnostic in the HT-7 tokamak Zhongyong Chen, Yuejiang Shi,Bo Lv,Baonian Wan, Shiyao Lin,Liqun Hu,Qingsheng Hu, Shenxia Liu,Shiyao.
Lecture 3-Building a Detector (cont’d) George K. Parks Space Sciences Laboratory UC Berkeley, Berkeley, CA.
Simbol–X workshopMay 14th, 2007 The Simbol-X Detector Payload P. Laurent CEA/Saclay & APC.
Readout Architecture for MuCh Introduction of MuCh Layout of Much ( proposed several schemes) Read ASIC’s Key features Basic Readout chain ROC Block Diagram.
The DAMPE STK G. Ambrosi INFN Perugia. The DAMPE Detector Mass: 1480 Kg Power: 600 W Data: 16 Gbyte/day Liftime: 5 years 2.
WG3 – STRIP R&D ITS - COMSATS P. Riedler, G. Contin, A. Rivetti – WG3 conveners.
BESIII EMC Simulation & Reconstruction He Miao
August DESY-HH VFCAL Report W. Lohmann, DESY Infrastructure for sensor diagnostics FE Electronics Development Sensor test facilities Laser Alignment.
SphinX Workshop Wrocław 2007PP SphinX electronic delay times and priorities.
MPI Semiconductor Laboratory, The XEUS Instrument Working Group, PNSensor The X-ray Evolving-Universe Spectroscopy (XEUS) mission is under study by the.
Development of a Single Ion Detector for Radiation Track Structure Studies F. Vasi, M. Casiraghi, R. Schulte, V. Bashkirov.
Update on works with SiPMs at Pisa Matteo Morrocchi.
CdTe prototype detector testing Anja Schubert The University of Melbourne 9 May 2011 Updates.
MICRO-STRIP METAL DETECTOR FOR BEAM DIAGNOSTICS PRINCIPLE OF OPERATION Passing through metal strips a beam of charged particles or synchrotron radiation.
12 th Pisa Meeting, Isola d’Elba, 25 May 2012 Politecnico di Milano, Italy New Development of Silicon Drift Detectors for Gamma-ray.
Readout Electronics for high-count-rate high-resolution
CEA DSM Irfu IDeF-X HD Imaging Detector Front-end for X-ray with High Dynamic range Alicja Michalowska, CEA-IRFU 1 Journées VLSI June 2010.
0 Characterization studies of the detector modules for the CBM Silicon Tracking System J.Heuser 1, V.Kyva 2, H.Malygina 2,3, I.Panasenko 2 V.Pugatch 2,
Study of PC-HPGe detector for dark matter search CDEX collaboration Application of Germanium Detector in Fundamental Research Apr. 7-13,2013.
A Low-noise Front-end ASIC design based on TOT technique for Read-out of Micro-Pattern Gas Detectors Huaishen Li, Na Wang, Wei Lai, Xiaoshan Jiang 1 State.
Status of ULE-HPGe Experiment for WIMP Search in YangYang
The PFA focal plane camera
Silicon microstrip detector for imaging of fast processes at high intensity synchrotron radiation beam. Budker INP V.Aulchenko1,2, L.Shekhtman1,2, B.Tolochko3,2,
A General Purpose Charge Readout Chip for TPC Applications
CTA-LST meeting February 2015
Application of VATAGP7 ASICs in the Silicon detectors for the central tracker (forward part) S. Khabarov, A. Makankin, N. Zamiatin, ,
Development of a Compton Camera for online range monitoring
Low-power Wide-dynamic-range Readout System
DCH FEE 28 chs DCH prototype FEE &
A Low Power Readout ASIC for Time Projection Chambers in 65nm CMOS
The response function of semiconductor pixel detectors for highly ionizing particles Jan Jakubek, P. Soukup Institute of Experimental and Applied Physics,
On behalf of CEPC calorimeter working group
ASIC Electronics development for CDEX PCGe detector
High Rate Photon Irradiation Test with an 8-Plane TRT Sector Prototype
VATA-GP5 block diagram fast gain shaper discr. monostable trigger out
Overview of the Low Energy Telescope and its Performance in-orbit
HE instrument and in-orbit performance
ME instrument and in-orbit performance
Test Setup SiPM Hamamatsu S C Pixel size( 25um)
Presentation transcript:

Development of the X-ray Detectors for XTP Cao Xue-lei Institute of High Energy Physics, CAS IHEP, Beijing

Outline Payload configuration Primary design of the HE collimating telescope  Detector architecture  Performance of the CZT detectors with the readout chips. Development of the Focal Plane Detectors  Characteristics  Tests of the SPD  Performance of the SDD

3 XTP payload configuration

Architecture of Detectors of the Collimator Telescope The telescope consists of lots of modules 25 Units In each unit there are 25 modules, with the HV power for the detectors, the ADC and the FPGA controllers. 25 Modules in one Unit. 16 CZT detectors used one ASIC for readout in one module. So there are channels for the hard X-ray collimated telescope. Collimator Telescope Unit1 (ADC, FPGA, HV) Unit2 (ADC, FPGA, HV) Unit3 (ADC, FPGA, HV) …. Module-1 16-ch ASIC CZT detector and PreA -1 CZT detector and PreA -2 CZT detector and PreA -3 CZT detector and PreA -16 …. Module-2 16 –ch ASIC Module-3 16-ch ASIC …. Module ch ASIC Unit25 (ADC, FPGA, HV)

Characteristics of the High energy X-ray Collimating Telescope FOV : 1°×1° 。 Active area : 2500 cm Detector : CZT Energy resolution : FWHM Time resolution : 200μs Energy coverage : 8-100keV Single detector size: 5mm*5mm*2mm Total number of the DET: Total mass: ~200kg Power dissipation: ~200W CZT detectors Front-to-end electronics Collimator

Characteristics Prototype (From to ) of the Collimator Detectors DetectorsCZT Single detector size5mm*5mm*2mm Number of detectors192 Energy resolution FWHM -10 Time resolution200µs Power dissipation45W

The CZT detectors The CZT detectors are made by the Northwestern Polytechnical University; The efficiency is about 87% at 100 keV for a 2mm thickness CZT. Thickness (mm) Efficiency The CZT Crystal and the electrode preparation CZT detectors with different size Pixels electrodes Spectrums of the CZT detector Vs scintillator Spectrum of the LaBr 3 CZT has better energy resolution than LaBr 3

CZT detectors for the prototype

Test of the CZT chips code Volt-Ampere characteristic Am-241 source test -100v (nA) 100v (nA) -200v (nA) 200v (nA) -300v (nA) 300v (nA) V Energy resolution v4.68% v4.89% v5.30% v5.55% v6.37% v6.47% Size : 5mm×5mm×2mm >200 pieces have already made

Performance of the CZT detector Single channel readout system of the CZT detector Spectrum of the Am-241 source used the CZT detector prototype Functional block diagram of the prototype Energy resolution : FWHM 。 CZT detector size : 5mm*5mm*1mm Temperature : 23 ℃, Humidity : 18% Preamplifier CZT HV Power Amplifier MCA

The Chips made in IHEP Include three parts: Pre-Amplifier, Amplifier, Comparator and Peak-Holder Some results of the readout chips Preamp: Charge-sensitive amplifiers Resistor -capacitor feedback Noise : ENC ~60e , for Si detector, the Cd=0.1pF Peaking Time : 0.3μs, 1μs, 6μs, 12 μ s Power : ~5 mW/per channel Input:: +/- signals Process: 0.35 um N-well CMOS

The test board for the readout chips Pre- Amp Si-Detector Am p Comparator and Peak-Holder power

Bonding wire for Pre-Amp

Simulated result Result from the test board Input signals, blue Signal from the preamp ( red ) Signals from the amplifiers ( green ) Peak holding signals

Test with the Si-PIN detector Detector and Pre-Amplifier connect by bonding wire directly 5mm 2 Si - PIN detector Am-241 radioactive source Commercial MCA room temperature FWHM is V

A Single-channel test board for CZT with readout chips

Nine-channel prototype 9 CZT detectors with the size of 5mm*5mm*2mm Nine channels wire bonded-chip

Spectrum of the Am-241 of the 9-channel prototype Energy resolution about FWHM

ASIC for CZT pixel detectors Type: VA32TA6 Made by: Ideas company Power: <1mW /Channel Channel: 32 Noise: e/pF ADC: 10 bit SEL : 18 MeV Process: 0.35 um N-well CMOS VA32TA6 are Used in HXMT ME telescope The VA-TA principle The architecture of VA parts

Some tests on the VA32TA6 A prototype of the Si-PIN with the VA32TA6 Arrival time intervals(us) Counts Spectrum of the Am-241 source by the 6mm 2 Si-PIN with the VA32TA6 ASIC, with the energy resolution of FWHM keV This fig shows the arrival time interval distribution of the VA32TA6 prototype. The dead time is shorter than 180 us.

SEU/SEL test Single event test in the tandem accelerator line. The single particle lock threshold is about 18 MeV.cm 2 /mg Experiment with VA32TA6 work in the temperature -50 ℃, 14 days Electrostatics discharge test of the VA32TA6, it is very impressible for the ESD, <50V

Architecture of the Focal Plane Detectors 3 focal plane detectors 256 pixels CZT detectors are used. For one focal plane detectors, 4 64-channels ASIC are used for the read-out electronics. with the HV power for the detectors, the ADC and the FPGA. 16*16 pixel CZT Pixel size: 1mm*1mm*1mm

Characteristics of the focal plane detectors of the HE telescope Detector : CZT pixel detector DET Number : 3 Pixel Number per DET : 256 CZT pixel size : 1mm*1mm*1mm Power dissipation : ~80W Energy resolution : FWHM Time resolution : 10us Work temperature : -10 ~ +20 ℃ Energy coverage: 8-30keV

Prototype of LE Focal Plane Detectors based on SPD Detector Si-PIN pixel detectors, SPD Pixel size 1mm*1mm*0.5mm Number of the pixels 100 Energy resolution FWHM -40 Time resolution 20µs Power 35W

SPD detectors Pixel size : mm 2 Thickness : 300μm-2mm Pixel structure : P-I-N Superiority : 1 ) High detection efficiency in keV, 2 ) Good energy resolution , FWHM ; 3 ) Acceptable spatial resolution: 300μm-3mm ; 4 ) High time resolution , <1us

SPD chips The 100 pixels SPD packaged on PCB The leakage current of SPD in +25 ℃ Parameters of the SPD  Pixel size : 1mm*1mm  Thickness : 500um  Pixel number : 10*10  Leakage current : < 0.4nA depleted The first prototype

The Prototype Based on the SPD SPD prototype block diagramThe testing photo of the SPD

Si-PIN 像素探测器样机(3) The spectrum of the Am -241 source by the 20 pixels of the SPD Am-241 source spectrum of one pixel, temperature 21 ℃, Results :  Energy resolution: FWHM at room temperature  Dead time : 20us

Si-PIN 探测器低温测试 Temperature control system in vacuum, for SPD detector test Peltier device Results : Si-PIN pixel detector at -15 ℃, for the Am- 241 source, the energy resolution, FWHM The spectrum of the Am-241 used SPD, in -15 ℃

7-channel SDD detectors(2010) 7 SDD detectors. Active area 1cm^2 FWHM -35 ℃

Summary SDD and SPD is suitable for the low energy X-ray focal plane detector, the energy resolution better than FWHM The high energy collimated telescope uses the CZT detectors, it has an active area of 2500 cm 2, and the energy resolution is better than The CZT pixel detectors are used for the HE focal plane detectors. The energy resolution should better than 2