Sector 0 To improve the performance of FACET, sectors 2-6 and 12-16 (a total of 900m beam-line) were realigned using the laser alignment system as their.

Slides:



Advertisements
Similar presentations
Research Instrumentation Special Interest Group Sensors & Instrumentation Knowledge Transfer Network Report on American Light Source Facilities Oliver.
Advertisements

LHC Collimator Survey Train Concept / Development / Status Patrick Bestmann CERN BE/ABP/SU IWAA /09/2010 Remote Controlled Measurements in the LHC.
Experience Report with the Alignment Diagnostic System Georg Gassner September 17 th 2010.
FAC review, 10/27 D. Schultz 1 e-Beams System Update Injector System Installation has started. Linac System Preparing for ’06 installation. Controls System.
Accelerator and Beam Delivery The LC-ABD (Linear Collider: Accelerator and Beam Delivery) consortium is a group of UK institutes aiming to develop new.
James Welch October 30, FEL Commissioning Plans J. Welch, et. al. FEL Commissioning Plans J. Welch, et. al. Accelerator.
Undulator Alignment Strategy – April 20, 2006 Heinz-Dieter Nuhn, SLAC / LCLS FAC 1 Undulator Alignment Strategy Heinz-Dieter Nuhn,
LTU & Electron Beam Dump Linac Coherent Light Source Stanford Synchrotron Radiation Laboratory Stanford Linear Accelerator Center LCLS Technical Design.
Richard M. Bionta XTOD October 12, 2004 UCRL-PRES-XXXXX X Ray Transport, Optics, and Diagnostics, Overview Facility Advisory Committee.
Alignment Strategy for Light Source Facilities LCLS Case Catherine LeCocq SLAC 03/31/08.
October 20-21, 2005 Internal LCLS Undulator Alignment and Motion Review Catherine LeCocq, SLAC 1 Undulator Alignment Concept &
Linac Coherent Light Source Stanford Synchrotron Radiation Laboratory Stanford Linear Accelerator Center LCLS Undulator Systems.
Wire Position System LCLS Undulator Alignment and Motion Review, Oct. 22, Franz Peters Wire Position System The Undulator.
John N. Galayda LCLS Commissioning 22 September 2004 Welcome/Charge Welcome to the Workshop LCLS Status Since the January.
Yurii Levashov LCLS Undulator Fiducialization October 20, 2005 *Work supported in part by DOE Contract DE-AC02-76SF LCLS.
Accelerator Systems Division FACET Project Management John Seeman for the FACET Study Group PPA Directorate Stanford Linear Accelerator Center DOE FACET.
Linac Coherent Light Source Stanford Synchrotron Radiation Laboratory Stanford Linear Accelerator Center LCLS Undulator Alignment.
Robert Ruland Installation Alignment -Magnetic Measurements – Fiducialization April 7-8, 2005 FAC Meeting 1 Installation Alignment,
BBA Related Issues Linac Coherent Light Source Stanford Synchrotron Radiation Laboratory Stanford Linear Accelerator Center Undulator.
John Arthur Photon April 20, 2006 Photon Systems Update John Arthur SLAC Photon Systems Manager.
Linac Coherent Light Source Stanford Synchrotron Radiation Laboratory Stanford Linear Accelerator Center LCLS Undulator Physics.
Richard M. Bionta X-Ray Transport, Diagnostic, & Commissioning September 22, 2004 UCRL-PRES Two Problems... LCLS Diagnostics.
Opening Comments and Charge 19 January 2004 Linac Coherent Light Source Stanford Synchrotron Radiation Laboratory Stanford Linear.
Overview of Proposed Parameter Changes Linac Coherent Light Source Stanford Synchrotron Radiation Laboratory Stanford Linear Accelerator.
John Arthur X-ray April 20, 2006 X-Ray Beamline and Experiment Layout John Arthur LCLS Photon Systems Manager.
NLC - The Next Linear Collider Project IR Working Group Summary Tom Markiewicz LC R&D Workshop, UCSC June 29, 2002.
A U.S. Department of Energy Office of Science Laboratory Operated by The University of Chicago Argonne National Laboratory Office of Science U.S. Department.
LCLS Undulator Systems TDR Charge Linac Coherent Light Source Stanford Linear Accelerator Center Technical Review, March 3, 2004.
Prepared using support of U.S. Department of Energy under Contract No. DE-AC02-76SF00515 by the Stanford Linear Accelerator Center, Stanford, California.
Zachary Wolf Undulator Oct 12, LCLS Undulator Tuning Zack Wolf, Yurii Levashov, Achim Weidemann, Seva Kaplounenko,
DELTA Quadrant Tuning Y. Levashov, E. Reese. 2 Tolerances for prototype quadrant tuning Magnet center deviations from a nominal center line < ± 50  m.
Status of LCLS A. Brachmann, SLAC National Accelerator Laboratory.
ALIGNMENT DESIGN AND STATUS OF TAIWAN PHOTON SOURCE WEI-YANG LAI October,
David Urner, Oxford University, RHUL – June StaFF Stabilization of Final Focus Motion Stabilization with Nano-Meter Precision David Urner Paul Coe.
Tube Laser Alignment System Georg Gassner. 2 Delta Undulator Project Tube Laser Alignment System SLAC, December 11 th 2012 Period 32 mm, Length 3.2m Gap.
LASER AND ADVANCES IN METROLOGY
Tilt meter fiducial Guide rail Abstract This poster covers the survey and alignment techniques selected for installation of the SPIRAL2 accelerator devices.
Franz Peters, Georg Gassner WPM/HLS Status and June 17 th, WPM & HLS Status and Schedule Franz Peters, Georg Gassner.
1 Kenneth Osborne, 9/14/07 Inter Group communications at the Advanced Light Source. Overview of the different methods of communication between different.
1 BROOKHAVEN SCIENCE ASSOCIATES Abstract Magnet and Girder Integration Lewis Doom, NSLS-II Project National Synchrotron Light Source II (NSLS-II) will.
SCU Segmented Cryostat Concept M. Leitner, S. Prestemon, D. Arbelaez, S. Myers September 2 nd, 2014.
Low Emittance RF Gun Developments for PAL-XFEL
Orbit Control For Diamond Light Source Ian Martin Joint Accelerator Workshop Rutherford Appleton Laboratory28 th -29 th April 2004.
Global Design Effort Beam Delivery System => EDR LCWS07 June 2, 2007 at DESY Andrei Seryi for BDS Area leaders Deepa Angal-Kalinin, A.S., Hitoshi Yamamoto.
BEPCII Prealignment Installation Survey and Alignment Accelerator Center of IHEP Xiaolong Wang
CLIC survey and alignment 1 CLIC CES meeting STARTSLIDE CLIC SURVEY AND ALIGNMENT Hélène MAINAUD DURAND.
ELECTRON MOVING AT CONSTANT VELOCITY
FACET User Support Carsten Hast Accelerator Research Division Test Facilities Department
Calibration of the Nikon D200 for Close-Range Photogrammetry
CLIC Module WG 20/07/2009 H. MAINAUD DURAND, BE-ABP/SU Pre-alignment system and impact on module design.
Dec 04 Beam Stability First considerations for beam stability at ALBA Marc Muñoz ALBA Team.
CERN, 27-Mar EuCARD NCLinac Task /3/2009.
1 Jennifer L. Loos 1 SULI Presentation August 13, 2009 Design and Implementation of a Thermal and Acoustic X-ray Detector to Measure.
Catherine LeCocq, SLAC Alignment Plan for the LCLS Undulator IWAA 2006,1 Alignment Plan for the LCLS Undulator Catherine.
October 27-28, 2005 FAC Meeting Undulator Metrology Catherine LeCocq, SLAC 1 Undulator Metrology Catherine LeCocq, SLAC October.
The LCLS-II project consists of a new gun, a new superconducting linac, and new variable gap undulators. Civil construction will be at a minimum, and existing.
Tube Laser Alignment System
Heung-Sik Kang Pohang Accelerator Laboratory
Survey for SPL Dominique Missiaen BE-ABP/SU. Outline 12/11/2008 Dominique Missiaen BE-ABP-SU, Survey for SPL 2  Scope & Main Parameters  Technical Description.
November 12-13, 2007 Super-B Factory: Accelerator Costing, PEP-II Hardware and Schedule J. Seeman SLAC International Review Committee meeting November.
The Alignment of DTL in CSNS Institute of High Energy Physics, CAS KE Zhiyong
Laser beam trajectory measurement with a CCD camera Georg Gassner.
Tutorial On Fiducialization Of Accelerator Magnets And Undulators
Scintillation Material Encapsulation Fixture
LumiCal mechanical design, integration with LDC and laser alignment
Experimental Facilities Planning
The SPEAR3 Upgrade Project at SLAC
The SPEAR3 Upgrade Project at SLAC
Robert Pushor, Catherine LeCocq, Brian Fuss, Georg Gassner
Alignment Diagnostic System Status
Presentation transcript:

Sector 0 To improve the performance of FACET, sectors 2-6 and (a total of 900m beam-line) were realigned using the laser alignment system as their primary alignment tool. Geodetic Laboratory The Geodetic Laboratory at Sector 10 along the linac is situated in an old access tunnel with very stable temperatures and stable walls. It is used for a variety of tasks from routine calibration runs of leveling equipment and distance meters to photogrammetric calibration. Laser tracker distance and angle measurement calibration tests are carried out as well as general acceptance tests performed after instruments are shipped across the country for maintenance. A setup to determine the thermal coefficient of expansion of leveling rods is presently being commissioned. To determine the angle of small objects or mirrors an alignment system was developed. The system is based on measuring the incoming and outgoing trajectories of a laser beam, which is reflected off a surface. We developed a calibration procedure which allows us to fiducialize a CCD camera. The laser beam hits the CCD chip of the camera directly. Watching the image of the CCD on a computer screen enables the camera to be aligned with respect to the laser dot. By measuring the fiducials on the camera a point on the laser line can be determined. Measuring multiple points along the line of the laser beam allows the trajectory to be determined. Acknowledgments We would like to thank our colleagues Brendan Dix, Brian Fuss, Francis Gaudreault, Michael Gaydosh, Levirt Griffin, Hans Imfeld, Franz Peters, Michael Rogers and Bryan Rutledge. Work supported by Department of Energy contract DE-AC02-76SF00515 Acknowledgments We would like to thank our colleagues Brendan Dix, Brian Fuss, Francis Gaudreault, Michael Gaydosh, Levirt Griffin, Hans Imfeld, Franz Peters, Michael Rogers and Bryan Rutledge. Work supported by Department of Energy contract DE-AC02-76SF00515 During the September 2011 machine shut down the linac and the linac to booster area were disassembled and re-aligned to correct for floor movements. Stanford Synchrotron Radiation Light Source Since the SPEAR ring is built on unstable soil, an HLS system has been installed in the ring and on several beam lines. Based on the results of the HLS measurements it was decided to insulate walls and ceilings of selected areas around the ring to reduce floor movements. Sector 2-7Sector 10-1Sector 20-3 Camera Position X=0.000 mmX=3.352 mmX=6.576 mm Y=0.000 mmY= mmY= mm Facility for Advanced aCcelerator Experimental Tests FACET uses part of SLAC's two-mile-long linear accelerator to generate high-density beams of electrons and their antimatter counterparts, positrons. This produces large electric and magnetic fields in a very short time - ideal for creating exotic states of matter and researching advanced accelerator technologies. Construction at Sector 20 was completed and the first user run finished this July. During the last two years all beam components and experiments were aligned. Linac Coherent Light Source Machine The alignment network was been re-measured several times to correct the network for shrinking walls in the tunnel. The data were analyzed utilizing the fact that the 33 quadrupoles in the undulator hall form a straight line after beam-based alignment. One of the alignment tasks was to align the HXRSS (Hard X-Ray Self Seeding Project). The goal was to align a small diamond crystal ~2 X 4mm without touching it. To do this, optical tooling was used to determine its translation and a laser beam was used to determine its orientation within a few arc seconds. Alignment Diagnostic System (ADS) correcting 2 components, quadrupole position and beam position monitor (BPM) offset drifts. Currently, the ADS is used to correct quadrupole offsets. After this correction the BPM offsets are readily available. The figure on the left shows a comparison of BPM offsets determined after the ADS application (Fast Cal) and as obtained by BBA (BBAFinal). Linac Coherent Light Source Experiments The LCLS I is now in its 6 th user run. All experimental hutches have been brought up and are user operated, experiments change constantly and require the alignment group to adapt from electron beam alignment to laser beam alignment. One of the more challenging tasks was relative alignment of mirrors with respect to each other to better than 15µrad. Linac Coherent Light Source Machine The alignment network was been re-measured several times to correct the network for shrinking walls in the tunnel. The data were analyzed utilizing the fact that the 33 quadrupoles in the undulator hall form a straight line after beam-based alignment. One of the alignment tasks was to align the HXRSS (Hard X-Ray Self Seeding Project). The goal was to align a small diamond crystal ~2 X 4mm without touching it. To do this, optical tooling was used to determine its translation and a laser beam was used to determine its orientation within a few arc seconds. Alignment Diagnostic System (ADS) correcting 2 components, quadrupole position and beam position monitor (BPM) offset drifts. Currently, the ADS is used to correct quadrupole offsets. After this correction the BPM offsets are readily available. The figure on the left shows a comparison of BPM offsets determined after the ADS application (Fast Cal) and as obtained by BBA (BBAFinal). Linac Coherent Light Source Experiments The LCLS I is now in its 6 th user run. All experimental hutches have been brought up and are user operated, experiments change constantly and require the alignment group to adapt from electron beam alignment to laser beam alignment. One of the more challenging tasks was relative alignment of mirrors with respect to each other to better than 15µrad. The undulator spans a distance of 132 meters and is structured into 33 girders. Each girder is equipped with four hydrostatic leveling sensors and four wire position monitors, part of the ADS. The ADS uses these sensor readings to provide relative position information for all girders with respect to each other. That system is in continuous operation since Recently, a new application of the ADS was commissioned to reduce the frequency of beam based alignment (BBA). BBA establishes the electron beam straightness required for FEL operation based on large changes in electron beam energy, a procedure which takes 3 – 4 hours. It does this by LCLS-II construction has started with civil construction of the Injector area. An alignment network has been established in the first 200m of the accelerator by tying the new network to the jack points of the laser alignment system of the linac light pipe. For the engineering we supplied terrain models, and monuments for civil construction in the LCLS-II coordinate system. One of the studies we participated in was a vibration measurement of simulated LCLS-II construction activities on LCLS-I beam stability. Tube Laser Alignment System For magnetic measurements of a delta undulator the position of a Hall probe has to be known to a few tens of micrometers. The hall probe is inserted through a 3.2m long 4.8mm diameter vacuum chamber. To localize the hall probe while it is being pushed through the vacuum chamber a laser alignment system is under development. The system is based on an interferometer laser which is narrowed down to a 3mm beam and a retroreflector at the end of the hall probe package. The laser beam travels through the vacuum chamber, reflects off of the retroreflector back out through the vacuum chamber where it is projected 90 degrees onto a CCD camera. The image on the CCD camera is used to determine the position of the retroreflector normal to the tube axis, More details in: G. Gassner, 10:15 CCD Camera Vacuum Tube (Ø4.8mm, length=3.2m) Retroreflector Laser Head Mirror Interferometer Beam Splitter Receiver Focusing Lenses GIS During the last 2 years, the GIS system has matured and opened new avenues for a growing customer base. Specialized web applications have been designed for a site-wide mechanical utilities network and a real-time space management system. These are integrated with the SLAC enterprise databases providing key information for the Facilities planners. Prototypes for mobile interactive applications are being tested. They are developed to be cross-platform, i.e. running on iOS, Android and Windows operating systems. For emergency planning, a GIS model has been implemented that allows for handling simultaneous updates. A first real-scale test was conducted during a site-wide earthquake drill. Building evacuation status and damage assessment were updated in the field by the emergency response teams and coordinated from the control center. Currently this GIS mobile app relies on network connectivity; the next step will be to allow switchable live-cached versions and integration with external self-contained network hardware. Hall Probe Mirror