Calibration Material Characteristics

Slides:



Advertisements
Similar presentations
Lesson 17 HEAT GENERATION
Advertisements

Thermal Analysis of a 1 Hour Fire Resistive Joint Design for Architectural Expansion Joints Preliminary Final Report Jason Shaw.
Heat Conduction of Zinc Specimen Femlab Simulation Measurement Calibration Technique: Effects of Heat Loss Through Specimen Surface Area.
Jordan Holmes Stephen Merrill. Objective Our goal was to find the thermal conductivities (k) of different kinds of gloves. We tested the following: Conventional.
Regression Analysis Module 3. Regression Regression is the attempt to explain the variation in a dependent variable using the variation in independent.
Calibration Methods Introduction
NOAA-CREST GPR Study Eric Harmsen, Associate Researcher Agricultural and Biosystems Engineering.
Chapter 2: Overall Heat Transfer Coefficient
Basic Questions Regarding All Analytical & Instrumental Methods (p 17-18) What accuracy and precision are required? How much sample do I have available,
Bald Head Convective Calculator Jess Rose Jeff Amelang Winter 2009.
Al 2 O 3 Post Combustion Chamber Post Combustion Chamber ANSYS Thermal Model (Embedded Fuel Grain Concept) Outer radius: 1.25” ( m) Inner radius:
Characterisation and Reliability Testing of THz Schottky Diodes Chris Price University of Birmingham, UK
One Dimensional Steady Heat Conduction problems P M V Subbarao Associate Professor Mechanical Engineering Department IIT Delhi Simple ideas for complex.
Solutions of the Conduction Equation P M V Subbarao Associate Professor Mechanical Engineering Department IIT Delhi An Idea Generates More Mathematics….
SENSORS AND TRANSDUCERS
Engineering 80 – Spring 2015 Temperature Measurements
Temperature Sensors.
Principles of Surveying
Temperature 1.  Temperature is defined as the degree of hotness or coldness of a body measured on a definite scale  Temperature is the driving force.
Feasibility Analysis h T1 T2 T3 T4 T5 One Dimensional Transient Analysis One Dimensional Finite Difference Steady State Analysis T1 and T5 will be known.
Heat Transfer Rates Conduction: Fourier’s Law
Topic 1 different attributes that characterize sensors ETEC 6405.
Vielitzer Straße Selb GERMANY Tel.: Fax: Linseis Inc. 20 Washington Road P.O.Box 666 Princeton-Jct.
Metrology and Gauging Instructed by: Dr. Sajid Zaidi
S. Pistacchio2 , G. Bovesecchi1 , P. Coppa1
Flexible Assessment of Thermal Transport Properties of Thermal Barrier Systems Measured by The Hot Disk Method Caroline Goddard 1, Tobias Öhman 2 ; Nicolaie.
Revised Theory of the Slug Calorimeter Method for Accurate Thermal Conductivity and Thermal Diffusivity Measurements Akhan Tleoubaev, Andrzej Brzezinski.
Transient Plane Source Techniques for measuring Thermal Conductivity of Various Materials Evitherm September 15, 2003 Dr. Lars Hälldahl Hot Disk AB.
Fire Resistive Materials: THERMAL PERFORMANCE TESTING
1 THERMAL CONDUCTIVITY OF SILICATE BONDED SAMPLES Status of measurements with the thermal conductivity facility in Firenze June, 7 th 2007.
Chapter 21: Molecules in motion
Uncertainties Using & Calculating Uncertainties for Electrical Measurement.
1 Atmospheric Radiation – Lecture 9 PHY Lecture 10 Infrared radiation in a cloudy atmosphere: approximations.
Thermo-mechanics J. Cugnoni, LMAF / EPFL Three kind of « thermo-mechanics » 1. Un-coupled: Known temperature field => mechanical model (linear statics.
3. Sensor characteristics Static sensor characteristics
Records force & distance. * Calibration “strain gauge” * 6 Samples * What it Means * Video * Results.
Objectives Calculate heat transfer by all three modes Phase change Next class Apply Bernoulli equation to flow in a duct.
One-Dimensional Steady-State Conduction
ATLAS Calorimeter Argon Gap Convection Test Bed April 25,
Lecture I Sensors.
Silesian University of Technology in Gliwice Inverse approach for identification of the shrinkage gap thermal resistance in continuous casting of metals.
Aerospace Engineering Laboratory I  Basics for Physical Quantities and Measurement  Physical Quantity  Measured Quantity VS Derived Quantity.
EVITherM EVITherM Bruno HAY 16/09/2003 Task 4.1 : Best Practice Guides  Compile information on measurement methods and laboratories  Direct the Evitherm.
Chapter 1: Introduction 1. Type of instrumental methods Radiation Electrical method Thermal properties Others 2. Instruments for analysis Non-electrical.
Evan Selin & Terrance Hess.  Find temperature at points throughout a square plate subject to several types of boundary conditions  Boundary Conditions:
CHAPTER 2 GMI | Production Technology. BASIC INSPECTION AND PROCEDURES Learning Objectives Define and differentiate measuring and gauging List the advantages.
Improve Accuracy with Software: S 0 Calibration. Calibrating the System Plot Draw the best straight line fit for the above function –You can find the.
ABOUT INSTRUMENTATION Instrumentation is used in almost every industrial process and system, where consistent and reliable operations are required. Instrumentation.
Indicate the length up to one estimated value…. A. B. C.
Hot Disk Transient Plane Source (TPS) Technique
Fundamentals of Data Analysis Lecture 11 Methods of parametric estimation.
Tutorial 2b: Thermo-physical properties
Accurate Simultaneous Measurements of Thermal Conductivity and Volumetric Specific Heat Of Rubber, Elastomers, and Other Materials Akhan Tleoubaev, Andrzej.
Date of download: 10/20/2017 Copyright © ASME. All rights reserved.
Types of graphs, their relationship and equation
Chapter 8 : Natural Convection
Heat Transfer Ana Galvao, Julie Kessler, Luke O’Malley, Matteo Ricci & Jessica Young “L JJAM” aka “Dream Team” aka Team 3 CHBE446 02/02/18 Aka “Haha. A.
Statistical Methods For Engineers
Introduction to Instrumentation Engineering
Thermophysical Laboratory
Thermo-mechanics J. Cugnoni, LMAF / EPFL 2009.
1. Use the quadratic formula to find all real zeros of the second-degree polynomial
Linear Models and Equations
Boiling Heat Transfer Exercise
Lesson 10: Sensor and Transducer Electrical Characteristics
Hot wire measurement method based on inverse method
The NETZSCH LFA 457 MicroFlash -125 … 1100°C
Unit 1-2 Test Guide Matter Review Density
© E.P. Belan and D.V. Khar’kov, 2019
Thermo-mechanics J. Cugnoni, LMAF / EPFL 2012.
Presentation transcript:

Thermal Conductivity & Thermal Effusivity Calibration of the C-Therm TCi (MTPS) and TC-30

Calibration Material Characteristics Isotropic- should be isotropic, free of directional thermal properties. Homogenous- should be highly homogenous. Surface- testing surface smooth and parallel. Stable- moisture resistant and non-degrading over calibration period. Temperature- the temperature dependent relationship with temperature should be the same for all calibration materials. i.e. If the thermal conductivity increases with increase in temperature, the same should be true for all calibration materials.

Calibration Material Selection Thermal Conductivity or thermal effusivity- Three or more materials should be used which span the thermal conductivity of your unknown sample i.e. for a range of 0.1 to 4 W/mK, which covers mostly polymers, the following standards could be used: Lexan: 0.25 W/mK Pyrex: 1.14 W/mK Steatite: 2.23 W/mK Pyroceram: 3.97 W/mK The larger the calibrated range of thermal conductivity / thermal effusivity, the more materials required. C-Therm TCi Manual

Measurement of Calibration Materials- Thermal Conductivity Thermal Conductivity- for highest accuracy, the calibration materials should be measured by absolute method (non-comparative). These include: Laserflash Apparatus (LFA), measures thermal diffusivity. Thermal Conductivity can be calculated with known density and specific heat. Range: 0.1 to 2000 W/mK. Accuracy: < 7% Hot Disk Transient Plane Source (TPS), measures thermal conductivity and thermal diffusivity. Range: 0.001 to 1800 W/mK. Accuracy: < 5% Guarded Hot Plate (GHP), measures thermal conductivity. Range 0.001 to 2 W/mK. Accuracy: < 3% *Measurement Accuracy: The accuracy of your MTPS or MTHW measured values is dependent on accuracy of calibration materials!

Measurement of Calibration Materials- Thermal Effusivity Thermal Effusivity- This is the square root of the product of thermal conductivity (W/mK), Specific Heat (J/kg-K) and Density (kg/m3). Thermal Conductivity- for highest accuracy, the calibration materials should be measured by absolute methods (non-comparative). These include: LFA, TPS and GHP. Accuracy: 3% to 7% Specific Heat- this property can be measured by a differential scanning calorimeter (DSC) or the Hot Disk TPS Specific Heat Testing Module. Accuracy: <3% Density- method would depend on material type and desired accuracy. *Measurement Accuracy: The accuracy of your MTPS or MTHW measured thermal effusivity values is dependent on composite accuracy of calibration materials: 10% to 15%. C-Therm / Mathis TC-30 Manual

MTPS Calibrating For the desired range, each calibration material is measured to generate a calibration graph of 1/m vs calibration material. It is important the calibration incorporate all parameters: Power, test time & start-time Contact agent & testing temperature. Any changes to these parameters would require re- calibration. Needs to be repeated at multiple temperature points to complete calibration process. TCi C-Therm TCi Manual

MTPS Calibrating con’t C-Therm TCi vs TC-30 predecessor to the TCi (MTPS), the TC-30 (MTHW) is calibrated in a similar manner. Calibration Graphs: Thermal Effusivity: 1/m vs calibration material < ~2000 Effusivity- linear fit. > ~2000 Effusivity- Polynomial fit. Thermal Conductivity: 1/m-m* vs calibration material- straight line fit.

MTPS Measurement If testing conditions are the same as the calibration, testing of unknown materials may begin for materials with-in the calibrated range. Raw data of 1/m (slope) C-Therm TCi Manual

MTPS Measurement Con’t Thermal Effusivity: Using the test slope (1/m), the result can be calculated using the created calibration. Straight-line fit for low effusivity materials Polynomial fit for high effusivity materials C-Therm TCi Manual

MTPS Measurement Con’t Thermal Conductivity Algorithm to calibrate and calculate k is the m*, it uses an iterative process to calibrate the sensor against measured materials with known thermal conductivity. The calibration process generates a value called m*. Using the test slope (1/m), the result can be calculated using the created calibration. C-Therm TCi Manual

MTPS Calibration Materials Here is list of OEM calibration materials, more can be found / tested at added to calibration for expanded ranges. C-Therm TCi Manual

MTPS Additional Reading http://www.google.com/patents/US6676287 http://www.ndt.net/article/ecndt2010/reports/1_05_11.pdf C-Therm TCi Manual (Can be found online) Mathis Instrument TC-30 Manual (Can be found online)