Ashraf M. Mahmoud, Associate professor CHROMATOGRAPHYCHROMATOGRAPHY.

Slides:



Advertisements
Similar presentations
Introduction to Chromatography
Advertisements

Gas Chromatography Introduction 1.) Gas Chromatography
Chromatographic Process Provides the analyte transport. Immobile phase. Mixture of components dispersed in the mobile phase.
ANALYTIC METHODS II. PART Jana Švarcová.  Chromatography  Electrophoresis  Potentiometry  Titration  Spectrophotometry.
HPLC 1. Introduction 1.Introduction CHROMATOGRAPHY Chromatography basically involves the separation of mixtures due to differences in the distribution.
Small particles (3-10  m) give high performance but require high pressure 1. Scope of LC Four types of liquid chromatography -Partition - Adsorption (liquid-solid)
Chapter 32 HIGH-PERRORMANCE LIQUID CHROMATOGRAPHY High-performance liquid chromatography (HPLC) is the most versatile and widely used type of elution chromatography.
Four basic types of column chromatography where mobile phase is a liquid Partition Chromatography Bonded-Phase Liquid-Liquid Adsorption Chromatography.
Chem. 133 – 5/5 Lecture. Announcements Lab Report 2.4 due Thursday – can turn in today for reduction of late penalties Term Project Progress Report –
High-Performance Liquid Chromatography HPLC, when GC won’t cut it!!!
High Performance Liquid Chromatography. HPLC originally refered to: High Pressure Liquid Chromatography currently refers to: High Precision Liquid Chromatography.
PRESENTED BY:- GAIKWAD OVESH & MD.NADEEM MANSOORI
B IOCHEMICAL INSTRUMENTAL ANALYSIS -11 Dr. Maha Al-Sedik.
CHAPTER 29 Supercritical Fluid Chromatography The mobile phase is a supercritical fluid (a fluid above its critical T and critical pressure) Supercritical.
LECTURE 4: CHROMATOGRAPHY Content: - Chromatographic separation - classifying analytical separations; column chromatography, planar chromatography - gas.
High Performance Liquid Chromatography High Performance Liquid Chromatography Chem. 331.
Analytical Chemistry Section D Separation Techniques.
Chapter 6 - Chromatography
Created with MindGenius Business 2005® Performance parameters (Advanced) Theoretical Plate Model Performance parameters (Advanced) Theoretical Plate Model.
Chapter 27 Gas Chromatography 1. Principles
1 HPLC HIGH PERFORMANCE LIQUID CHROMATOGRAPHY High Performance Liquid Chromatography (HPLC) is one of the most widely used techniques for identification,
High Performance Liquid Chromatography
Chromatography Chromatographic separation is based on distribution of separated compound (analyte) between mobile phase and stationary phase Richard Vytášek.
Chromatography Separates components in mixture: Based on - polarity
Chromatography Chapter 6.
Magnet Analytical Chemistry Unit 4
LECTURE 9 CHROMATOGRAPHIC SEPARATIONS The “stuff” you do before you analyze a “complex” sample.
1 High Performance Liquid Chromatography (HPLC) Lecture 40.
High Performance Liquid Chromatography Instrumentation.
1. Fast Protein Liquid Chromatography 2 FPLC A semi-automatic microprocessor controlled machine used primarily for the separation of macromolecules A.
History of Chromatography n Early LC carried out in glass columns n diameters: 1-5 cm n lengths: cm n Size of solid stationary phase n diameters:
Gihan Gawish.Dr High Performance Liquid Chromatography.
INTRODUCTION TO CHROMATOGRAPY
Intensive General Chemistry Chemical separations II Isabelle Vu Trieu
High Performance Liquid Chromatography. The chromatogram is a record of detector output Vs time as the analyte passes through the chromatography.
Introduction  High-performance liquid chromatography (HPLC) is a form of liquid chromatography.liquid chromatography  The main purpose is to separate.
1 Gas Chromatography Lecture Liquid Stationary Phases In general, the polarity of the stationary phase should match that of the sample constituents.
1 HPLC Lecture Displacement pumps Displacement pumps, on the other hand, is composed of a one directional motor driven plunger that pushes the mobile.
Best Broken into four categories
Chromatography High Performance Liquid Chromatography HPLC Chapter Dr Gihan Gawish.
HPLC.
High Performance Liquid Chromatography
Chapter 28 High Performance Liquid Chromatography.
Separation Techniques
HPLC.
1 High Performance Liquid Chromatography (HPLC) Lecture 40.
HPLC 1. Introduction 1.Introduction  INSTUMENTAL ANALYSIS  PRACTICAL 213 PHC  HPLC.
Chapter 33 High-Performance Liquid Chromatography.
Chem. 133 – 5/3 Lecture. Announcements Lab – Term Project Progress Report Due Today – Last Assignments: Term Project Poster and Peer Review Grading (Friday,
Dr. Ashraf M. M. Mahmoud, Associate professor
Instrumental Analysis (I)  HPLC Tutorial #7 PHCMt561 – 5 th Sem. Pharm.
Principles of chromatography
 Laboratory technique for the Separation of mixtures  Chroma -"color" and graphein - "to write”.  Colour bands - separation of individual compounds.
High Performance Liquid Chromatography. What is HPLC ? It is a separation technique that involves: Injection of small volume of liquid sample Into a tube.
High Performance Liquid Chromatography Presented by Dr. Kamal Modi 2 nd Year Resident.
High Performance Liquid Chromatography
High-Performance Liquid Chromatography HPLC, when GC won’t cut it!!!
Chromatography- TLC & HPLC
HPLC.
Size Exclusion Chromatography (SEC)
Chromatographic separation
Best Broken into four categories
HPLC.
High Performance Liquid Chromatography
BASICS OF SUPERCRITICAL FLUID CHROMATOGRAPHY
Four basic types of column chromatography
High Performance Liquid Chromatography
Principle of separation of different components:
High-Performance Liquid Chromatography
High-Performance Liquid Chromatography
Presentation transcript:

Ashraf M. Mahmoud, Associate professor CHROMATOGRAPHYCHROMATOGRAPHY

Thin Layer Chromatography (TLC) High-Performance Liquid Chromatography (HPLC) Gas Chromatography (GC) Common Techniques of Chromatography Common Techniques of Chromatography

What is the principle ? What is the Instrumentation ? What is the Applications of this Method ? For HPLC

time Respons e Principles of Column Chromatography

Instrumentation of HPLC Principles Behind the Instrument

Instrumentation of HPLC Mobile phase reservoir Solvent mixing valve Pump HPLC Chart Column Sample injection valve Recorder Waste Detector

Often the reservoirs contain a filtration system for filtering dust and particulate matters from the solvent to prevent these particles from damaging the pumps or injection valves or blocking the column. The reservoirs are equipped with a degasser for removing dissolved gases- usually oxygen and nitrogen-that interfere by forming bubbles in the column and the detector. Mobile-Phase Reservoir Mobile phase reservoir Solvent mixing valve Pump Chart Column injection valve Recorder Waste Detector

The Function: The pump provide a flow of the mobile-phase The pump provide a flow of the mobile-phase through the HPLC injector, column, and detector. through the HPLC injector, column, and detector. HPLC Pump Types of HPLC Pumps:  Constant-Pressure Pump.  Constant-Flow Pump. The requirements of standard HPLC pump include:  Generation of pressures up to 6000 Ibs/in2.  Pulse-free output.  Flow rate ranging from 0.1 to 10 ml/min.  Made of corrosion-resistant materials (stainless steel). Mobile phase reservoir Solvent mixing valve Pump Chart Column injection valve Recorder Waste Detector

HPLC Pump Constant-Pressure Pump: Advantages: Simple, inexpensive, easy to operate, and free from pulsations, resulting in smooth baselines. Disadvantages: Flow rate must be monitored carefully and constantly. Causes: change in the solvent viscosity (due to change in the temperature) Causes: change in the solvent viscosity (due to change in the temperature) Effect: influence both qualitative and quantitative analysis. How:

How: change in the flow rate reflects on change in retention volume (used for matching in the qualitative analysis). The component location and identification becomes difficult. In quantitative analysis, the most common detectors (UV and refractive index) are concentration sensitive. Changes in flow rate affect the time that a chromatographic band passes through the detector, which changes the peak area (which is used for quantitation. This type is used only for column packing

Advantages: Ability to repeat elution volume and peak area (regardless of viscosity changes or column blockage, up to the pressure limit of the pump). Constant-Flow Pump: This type is the most widely used in all common HPLC applications

Sample Injection System The Function: Introduction of the samples into the HPLC system with high precision, without interruption of the mobile phase flow. Injection valve (loop) is preferred for quantitative analysis Mobile phase reservoir Solvent mixing valve Pump Chart Column injection valve Recorder Waste Detector

HPLC Column The dimensions: cm long 4-5 mm internal diameter. Packing material:  Pellicular (spherical, non-porous, polymer beads with typical diameter of 30 to 40  m.  Porous particles (porous silica particles with typical diameter of 3 to 10  m. Porous silica particles gives better column efficiency, sample capacity, and speed of analysis Mobile phase reservoir Solvent mixing valve Pump Chart Column injection valve Recorder Waste Detector Column

HPLC Detector The function: Monitoring the mobile phase as it emerges from the column. as it emerges from the column.. The ideal characteristics: 1. Adequate sensitivity for the particular task. 1. Adequate sensitivity for the particular task. 2. Good stability and reproducibility. 2. Good stability and reproducibility. 3. Wide linear dynamic range of response. 3. Wide linear dynamic range of response. 4. Short response time that is independent on flow rate. 4. Short response time that is independent on flow rate. 5. Insensitive to changes in solvent, flow rate, and temperature. 5. Insensitive to changes in solvent, flow rate, and temperature. 6. Cell design that eliminates remixing of the separated bands. 6. Cell design that eliminates remixing of the separated bands. 7. High reliability and ease of use. 7. High reliability and ease of use. 8. Non-destructive for the sample. 8. Non-destructive for the sample. Mobile phase reservoir Solvent mixing valve Pump Chart Column injection valve Recorder Waste Detector

HPLC Detector Types of HPLC Detectors:  Bulk Property Detectors.  Solute Property Detectors. Respond to some physical property of the mobile-phase : Respond to some physical property of the mobile-phase (refractive index, dielectric constant, or density). Advantages: they are universal in application. Advantages: they are universal in application. Disadvantages: they have poor sensitivity and limited range Disadvantages: they have poor sensitivity and limited range

 Solute Property Detectors. They respond to some physical or chemical property of solutes (UV absorbance, fluorescence, or diffusion current). (UV absorbance, fluorescence, or diffusion current). Advantages: They high sensitivity and a wide range. Disadvantages: They are more selective; more than one detector may be required to meet the demands of an analytical problem. demands of an analytical problem. HPLC Detector

Type TypeResponse Sensitivity Sensitivity (ng/mL) (ng/mL) Refractive index Universal ConductimetricSelective UV/visible absorption Selective Mass-spectrometrySelective FluorescenceSelective HPLC Detector Characteristics of Typical HPLC Detectors :

HPLC Recorder Sample injected Peaks correspond to individual components Mobile phase reservoir Solvent mixing valve Pump Chart Column injection valve Recorder Detector Waste

Silica Gel: Polymers of polysilicic acid The OH groups attached to silicon atoms are reactive and account for the adsorptive properties of silica gel. properties of silica gel. Substances are adsorbed on silica gel via hydrogen bonding, and the surface hydroxyls serve as hydrogen donors. Si Si O OH O O O O O How we Can Select the HPLC Method ? How we Can Select the HPLC Method ? Adsorption Chromatography Alumina: Crystalline modifications of Al 2 O 3. Physical properties of alumina are similar to silica in terms of particle size, surface area, and average pore diameter.

Reversed-Phase Normal-Phase OH OH OH OH OH OH OH OH Polar stationary phase Polar stationary phase Non-polar mobile phase CH 3 No-Polar stationary phase No-Polar stationary phase Polar mobile phase Polar mobile phase Highlypolar Moder-atelypolar Nonpolar Highlypolar Moder-atelypolar Nonpolar Types of Partition Chromatography

Sephadex: Prepared from modified dextran gels that have an open network (molecular sieve) formed as a result of cross-linking. Sephadex gels are used for separation of hyrophilic solutes (peptides and nucleic acid) based on their molecular size. Size Exclusion Chromatography

Ion Exchanger: Chemically-modified HMW cross-linked polymers with attached ionic groups (anions or cations). These ionic groups are exchanged with ions of the same charge in the mobile phase. Anion exchange NR 3 OOCH 3 NH Cation exchane SO 3 - Na HCOO NH 3 Aln OOCH 3 NH O Ph - Ion Exchange Chromatography

IonExchange Adsorption Partition Nonionic polar Reversed-phase Normal-phase Gel permeation Gel filtration Sample Water-insolubleWater-soluble NonpolarIonic 10 4 Molecular weight Exclusion How we Can Select the HPLC Method ? How we Can Select the HPLC Method ?

What is the Applications of HPLC ? What is the Applications of HPLC ? Qualitative Analysis Purification of Compounds Identification of Compounds Peaks correspond to individual components CompoundImpurity Separation of Mixture ComponentsAuthentic Unknown

Quantitative Analysis  g/mL  g/mL  g/mL  g/mL  g/mL  g/mL 0 10 Unknown Concentration Peak hight Calibration curve External Standard Method

Quantitative Analysis Concentration Peak hight ratio Calibration curve Internal Standard Method  g/mL  g/mL  g/mL  g/mL  g/mL  g/mL Internal Standard Compound 0 10 Unknown

 Peak Base: An interpolation of the base line between the extremities of the peak..  Peak Area: The area enclosed by the peak and the peak base.  Peak Height: The distance from the peak maximum to the peak base.  Peak Width (t W ): The magnitude of the peak base intercepted by the tangents to the inflection points of the peak.  Retention time (t R ): The time between sample injection and the appearance of a solute peak at the detector of a chromatographic column.  Dead time (t m ): The time it takes for an unretained species (mobile phase) to pass through a column.  Adjusted Retention Time (t R ' ) is the time solute spent in the stationary phase and equals to [ t R - t m ].

 The Capacity Factor (k') is used to describe the migration rates of solutes on columns, It is defined as: For solute A, k A ' = (t R,A – t 0 )/t 0 ; = t' R,A /t 0  The Selectivity Factor (  ) of a column for the two solutes A and B in a mixture is defined as  = k' B /k' A  Chromatoaraohic column efficiency is determined by 1- Plate height (Height Equivarent to Theoretical Plate (HETP)= L/N 2- Number of Theoretical Plates(N) =16 (t R /t W ) 2 L = length of column  Resolution of the column (Rs) = (t R,B – t R,A )/0.5 (t w,A +t W,B ) R s = √N/4 x [α-1]/ α x [k' B /(k' B +1)] Column efficiency Selectivity Capacity

Example: Substances A and B have retention times of 16.4 and min; respectively, on a 30-cm column. An unretained species passes through the column in 1.30 min. The peak widths (at base) for A and B are 1.11 and 1.21 min, respectively. Calculate: (a) column resolutIon, (b) average number of plates in the column, (c) plate height, (d) length of column required to achieve. resolution of 1.5, and (e) time required to elute substance B on the longer column. (a.) Calculate the column resolution. R s = (2((t R ) y - (t R ) x ))/(W x + W y ) R s = (2(17.63 min min))/( 1.11 min min) = 1.06 (b.) Average number of plates N = 16 * (t R /W) 2 for peak A N = 16 * (16.4/1.11) 2 = 3493 plates for peak B N = 16 * (17.63/1.21) 2 = 3397 plates Average av N = ( )/2 plates = 3445 plate (c.) Height equivalent of a theoretical plate H = L/N = (30 cm/3445 plates) = cm/plate