Chapter-2 The Planar Imaging Important points in chapter 2 (chapter 13 from the book) The gamma camera (the basic principles of the gamma camera) The types.

Slides:



Advertisements
Similar presentations
Topic 8. Gamma Camera (II)
Advertisements

Instruments for Radiation Detection and Measurement Lab # 4.
NUCP 2371 Radiation Measurements II
Formation Characteristics
Gamma-Ray Spectra _ + The photomultiplier records the (UV) light emitted during electronic recombination in the scintillator. Therefore, the spectrum collected.
Geiger-Muller detector and Ionization chamber
Dispersive property of a G-M tube HV - + In the proportional region a G-M tube has dispersive properties tube voltage.
Chapter 8 Planar Scintigaraphy
LENSES. LENSES A light ray bends as it enters glass and bends again as it leaves ◦This refraction is due to the difference in the average speed of light.
1. 2  Ray Imaging u Inject a pharmaceutical labelled with a radioactive nuclide  Detect where  -rays are coming from u Local concentration in patient.
Remote sensing in meteorology
Nuclear Medicine Spring 2009 FINAL. 2 NM Team Nuclear medicine MD Nuclear medicine MD Physicist Physicist Pharmacist Pharmacist Technologist Technologist.
Gamma Camera Technology
Computed Tomography RAD309
INTERACTION OF IONISING RADIATION WITH MATTER
Main detector types Multi Pixel Photon Counter (MPPC) and Charge Coupled Devices (CCDs) How does it work? 1. Photon hits a pixel producing electron hole.
Lecture 2-Building a Detector George K. Parks Space Sciences Laboratory UC Berkeley, Berkeley, CA.
Instruments for Radiation Detection and Measurement
Planar scintigraphy produces two-dimensional images of three dimensional objects. It is handicapped by the superposition of active and nonactive layers.
Lecture 11  Production of Positron Emitters, Continued  The Positron Tomograph.
Instruments for Radiation Detection and Measurement Lab # 3 (1)
5.4.1 X-Rays. (a) describe the nature of X-rays Stowmarket Physics X-rays - nature Forms of electromagnetic radiation Short wavelength High frequency.
Radiation therapy is based on the exposure of malign tumor cells to significant but well localized doses of radiation to destroy the tumor cells. The.
Stopping Power The linear stopping power S for charged particles in a given absorber is simply defined as the differential energy loss for that particle.
Lenses Chapter 30.
HABIS X-RAY PRODUCTION AND EXPOSURE FACTORS X-RAY PRODUCTION AND EXPOSURE FACTORS PREPARED BY PREPARED BY Dr fahad albadr radiology chairman radiology.
LIGHT.
Fundamental Limits of Positron Emission Tomography
بسم الله الرحمن الرحيم و الشمس تجري لمستقر لها ذلك تقدير العزيز العليم صدق الله العظيم.
Nuclear Medicine: Planar Imaging and the Gamma Camera Katrina Cockburn Nuclear Medicine Physicist.
Light The Facts of Light – Notes Light Intro Shadows.
Medical Image Analysis Interaction of Electromagnetic Radiation with Matter in Medical Imaging Figures come from the textbook: Medical Image Analysis,
Dow Now What do you already know about light and how it moves?
Cosmic rays at sea level. There is in nearby interstellar space a flux of particles—mostly protons and atomic nuclei— travelling at almost the speed of.
1BTC - April, 1999 Natural Formation Gamma Ray Logging HGNS : Highly-integrated Gamma ray Neutron Sonde SGT-L : Scintillation Gamma ray Tool.
Nuclear Medicine Principles & Technology_I
PHYSICS 225, 2 ND YEAR LAB NUCLEAR RADIATION DETECTORS G.F. West Thurs, Jan. 19.
Medical applications of particle physics General characteristics of detectors (5 th Chapter) ASLI YILDIRIM.
1 Nuclear Medicine SPECT and PET. 2 a good book! SR Cherry, JA Sorenson, ME Phelps Physics in Nuclear Medicine Saunders, 2012.
INTERACTIONS OF RADIATION WITH MATTER. twCshttp:// twCs
Lecture 12  Last Week Summary  Sources of Image Degradation  Quality Control  The Sinogram  Introduction to Image Processing.
Nuclear Medicine Physics and Equipment 243 RAD 1 Dr. Abdo Mansour Assistant Professor of radiology
Nuclear Medicine Instrumentation 242 NMT 1 Dr. Abdo Mansour Assistant Professor of radiology
Chapter-2 The Planar Imaging Gamma Camera
Medical Physics.
PHY 102: Lecture Index of Refraction 10.2 Total Internal Reflection 10.3 Prism and Rainbows 10.4 Lenses 10.5 Formation of Images 10.6 Lens Equations.
Nuclear Medicine Introduction
 Two reasons medical tracers can be placed in a body:  Diagnose disease or Treat Disease  In both cases, several factors must be accounted for:  Gamma.
PET Imaging Positron Emission Tomography
Muhammad Musaddiq.
Chapter-5 Positron emission tomography (PET)
Gamma Camera Technology
Radiation detectors Ion chamber 2. Geiger Muller counter (GM).
Nuclear Medicine Physics
P.E.T. Positron Emission Tomography
Medical physics AMMAR ALHASAN University of Central Florida
Computed Tomography Data Acquisition
Learning Objectives By the end of this lesson you should…
Image quality and Performance Characteristics
Image quality and Performance Characteristics
X-Radiation.
Lecture 1: Development of the Analog Gamma Camera
Application of Nuclear Physics
Scintillation Counter
Lecture 1—Basic Principles of Scintillation
Gamma Camera & Basic Principles
Function and Structure in
Gamma Camera Ilker Ozsahin Oct
Assist. Prof. Dr. Ilker Ozsahin Oct
Remote sensing in meteorology
Presentation transcript:

Chapter-2 The Planar Imaging Important points in chapter 2 (chapter 13 from the book) The gamma camera (the basic principles of the gamma camera) The types of gamma camera The type of image acquisitions

Chapter-2 The Planar Imaging The distinction of nuclear medicine camera

Chapter-2 The Planar Imaging Types of nuclear medicine cameras (scanners) Gamma camera (2D-imaging) SPECT scanner (Single-photon emission computed tomography) (3D-imaging) PET scanner (positron emission tomography) (3D-imaging) In this chapter

Chapter-2 The Planar Imaging The Components of gamma camera The following components of the imaging system are described in the order they are encountered by the gamma ray photons emitted from the patients body Gamma Camera Components of a standard nuclear medicine imaging system

Chapter-2 The Planar Imaging The Components of gamma camera The collimator Scintillation crystal Light guide Photo-multiplier tubes (PMT) Electronic (digital position logic circuits, pulse-height analyzer circuits) Computer monitor Gamma Camera Components of a standard nuclear medicine imaging system

Chapter-2 The Planar Imaging The collimator Most practical gamma ray imaging systems employ the principle of absorptive collimation for image formation. Most commonly collimator consists of a lead plate containing a large number of precisely aligned holes (channels). They are usually depicted in cross section

Chapter-2 The Planar Imaging The collimator (advantages) Collimator is used to define the direction of the detected gamma rays. collimator restricts the rays from the source so that each point in the image corresponds to a unique point in the source. By controlling which gamma rays are accepted the collimator forms a projected image of the gamma ray distribution on the surface of the crystal (detector) by allowing only those gamma rays travelling along certain directions to reach the detector. A collimator selects photons perpendicular to the plane of the collimator face

Chapter-2 The Planar Imaging The collimator (advantages) The gamma ray not travelling in the proper direction are absorbed by the collimator before they reach the detector A collimator selects photons perpendicular to the plane of the collimator face

Chapter-2 The Planar Imaging Collimator

Chapter-2 The Planar Imaging The collimator (Disadvantage) This projection by absorption technique is an inherently inefficient method for using radiation because most of the potentially useful radiation travelling toward the detector actually is stopped by the collimator. This is one of the underlying reasons for the relatively poor quality of radionuclide images A collimator selects photons perpendicular to the plane of the collimator face

Chapter-2 The Planar Imaging Collimator in brief Nuclide emits gamma ray photons in all directions. The collimator allows only those photons travelling directly along the long axis of each hole to reach the crystal. Photons emitted in any other direction are absorbed by the septa between the holes. Without a collimator in front of the crystal, the image would be indistinct Septa are the lead walls between the holes (septum)

Chapter-2 The Planar Imaging Collimator images Magnified view of a typical parallel hole collimator showing the hole structure

Chapter-2 The Planar Imaging Types of collimators There are several types of collimators designed to channel photons of different energies By appropriate choice of collimator it is possible to magnify or minify images and to select between imaging quality and imaging speed

Chapter-2 The Planar Imaging Converging collimator collimator Parallel collimato r Non-parallel-hole collimator Pinhole collimator Diverging collimator Type of collimators that magnify or minify the images Slant-hole collimator

Chapter-2 The Planar Imaging Type of collimators 1. Parallel hole Parallel-hole collimators

Chapter-2 The Planar Imaging Slant-hole-collimators (is a variation of the parallel-hole collimator)

Chapter-2 The Planar Imaging Slant-hole-collimators (is a variation of the parallel-hole collimator) Parallel-hole collimatorsslant-hole collimators

Chapter-2 The Planar Imaging Type of collimators 2. Non-parallel (Pinhole, Diverging and Converging Note: Non parallel hole collimator provide a wider or a narrower field of view Types of collimators What is the FOV ?

Chapter-2 The Planar Imaging Type of collimators Pinhole collimators These have a single hole- the pinhole usually 2mm to 4mm in diameter (the size of the pinhole can be varied by using removable inserts) in a piece of lead, tungsten platinum or other heavy metal absorber. The pinhole aperture is located at the end of a lead cone, typically 20 to 25 cm from the detector. Pinhole collimator generates magnified images of a small organ like the thyroid or a joint. Pinhole collimator

Chapter-2 The Planar Imaging Type of collimators Pinhole collimators The image is projected upside down and reversed right to left at the crystal. However, it is usually corrected electronically on the viewing screen. Image size changes with object to pinhole distance. Therefore the pinhole collimator provides a somewhat distorted image of 3D objects because source planes at different distance from the collimator are magnified by different amounts. Pinhole collimator

Chapter-2 The Planar Imaging Type of collimators Converging collimators The holes are not parallel but are angled inward, toward the organ, as shown in the figure Consequently the organ appears larger at the face of the crystal. The converging collimator projects a magnified, non-inverted image of the source distribution Converging collimator

Chapter-2 The Planar Imaging Type of collimators diverging collimators The holes are not parallel but are angled the opposite way, outward toward the organ This is used most often on a camera with a small crystal such as portable camera Using a diverging collimator a large organ such as the lung can be captured on the face of a smaller crystal Project a minified, non-inverted image of the source distribution onto the detector Diverging collimator What is portable camera ?

Chapter-2 The Planar Imaging

Chapter-2 The Planar Imaging Type of collimators designed to channel photons of different energies And help to select between imaging quality and imaging speed

Chapter-2 The Planar Imaging Sensitivity and resolution

Chapter-2 The Planar Imaging Sensitivity and resolution

Chapter-2 The Planar Imaging Sensitivity and resolution

Chapter-2 The Planar Imaging Sensitivity and resolution If we look at two radioactive points in a patient’s organ. The photons from each of the points are emitted in all directions, but the detector can see only those photons that pass through the holes of the collimator The relatively large hole will admit photons scattered at relatively large angles from the direct line  lower the resolution However, the larger holes and thinner septa lead to higher sensitivity by admitting a higher percentage of the photons. For the same hole diameter, the longer the bore the higher the resolution

Chapter-2 The Planar Imaging Sensitivity and resolution The high resolution collimators admits photons from a smaller fraction of the organ, because more of its face is blocked by septa. The narrower and/or longer bore of its holes better collimate those photons that do enter the collimator. As a result, relatively closely spaced details in the source are more likely to appear clearly separated in the image. For the same hole diameter, the longer the bore the higher the resolution

Chapter-2 The Planar Imaging High sensitivity collimator  increase imaging speed  more photons are collected in shorter duration High resolution collimator  increase image quality  closely spaced details in the source are more likely to appear clearly separated in the image. For the same hole diameter, the longer the bore the higher the resolution Types of collimators help to select between imaging quality and imaging speed

Chapter-2 The Planar Imaging Type of collimators 1. Low energy all purpose collimator (LEAP) 1.These collimators have relatively large holes which allow the passage of many of the photons emanating from the patients 2.As such they have relatively high sensitivity at the expense of resolution. Because the holes are larger, photons arising from a larger region of the source are accepted as a result image resolution is decreased 3.These collimators are useful for imaging low-energy photons for which thick septa are not necessary 4.They are advantageous for images of short duration 5.They have thinner septa and bigger holes

Chapter-2 The Planar Imaging Type of collimators 2. High-resolution collimators These collimators have higher resolution images than the LEAP collimators They have more holes that are both smaller in diameter and longer in length

Chapter-2 The Planar Imaging Compare the performance of a LEAP with a high-resolution collimator

Chapter-2 The Planar Imaging Type of collimators designed to channel photons of different energies Thicker septa are used to block high- and medium-energy photons

Chapter-2 The Planar Imaging High and medium energy collimator Low-energy collimators are not adequate for the higher-energy photons of nuclides, nor foe positron emitters. The photons of theses nuclides can penetrate the thinner septa of both the LEAP and the high resolution collimators, resulting in poor resolution High energy collimators with thicker septa to reduce septal penetration are used, but thicker septa also mean smaller holes and, consequently lower sensitivity.

Chapter-2 The Planar Imaging Useful links (collimator exchange)

Chapter-2 The Planar Imaging The Components of gamma camera The collimator Camera head Scintillation crystal (detector) Light guide Photo-multiplier tubes (PMT) Electronic (preamplifiers and amplifiers-digital position logic circuits, pulse-height analyzer circuits) Computer monitor Gamma Camera Components of a standard nuclear medicine imaging system

Chapter-2 The Planar Imaging Gamma Camera

Chapter-2 The Planar Imaging Camera head Scintillation crystal (detector) The detector crystal (NaI(TI)) is a single large area mostly made of sodium iodide (NaI) that are doped with small amounts of stable thallium (TI). The thallium atoms dispersed in the crystal improves its response to the gamma rays photons NaL(TI) detector crystal, usually mm thick, with sizes up to 60x40 cm In the crystal is where the gamma rays are converted into light Scintillation crystal. The sodium iodided crystal “doped” with a thallium impurity is used to convert gamma photons into light photons

Chapter-2 The Planar Imaging Camera head Scintillation crystal (detector) The crystal is surrounded by a highly reflective material  to maximize light output The crystal is sealed inside a thin aluminum casing to protect it from moisture (they are fragile and can easily be cracked. Because NaI crystal absorb moisture from the atmosphere they must be sealed) An glass window on the back surface of the casing permits the scintillation light to reach the PM tubes. Schematic cross-section of a NaI (TI)crystal assembly for gamma camera

Chapter-2 The Planar Imaging Camera head Scintillation crystal (detector) The process of converting gamma rays to light is complex It can be summarized as the following: The gamma photon transfers its energy in one or more Compton or photoelectric interactions in the crystal Each of these energetic electrons produced by the gamma interactions in turn distributes its energy among electrons in the crystal leaving them in the excited state. As these return to their original state, some of their energy is released as light photons. For each KeV of gamma ray energy absorbed by the crystal, approximately 40 light photons are emitted PM tubes detect these light photons

Chapter-2 The Planar Imaging Interaction of Photons with matter Compton scattering Photoelectric effect Pair production Predominant type of interaction for various combinations of incident photons and absorber atomic numbers

Chapter-2 The Planar Imaging What is kiloelectronvolt KeV? Events occurring at the atomic level, such as radioactive decay, involve amounts of mass and energy that are very small when described in SI or other conventional units. Therefore, they often are described in terms of specially defined units that are more convenient for atomic scale.

Chapter-2 The Planar Imaging Camera head Scintillation crystal (detector) The choice of the thickness of the crystal is a trade-off between its detection efficiency (which increase with increasing thickness) and its resolution (which deteriorates with increasing thickness) Thicker crystal, by absorbing more of the original and the scattered gamma rays, have a relatively high sensitivity in which almost all of the gamma ray energy reaching the crystal is absorbed. Thinner crystals have lower sensitivity because more photons escape Most general purpose gamma camera have crystal thicknesses of 9.5 mm

Chapter-2 The Planar Imaging The Components of gamma camera The collimator Camera head Scintillation crystal Light guide Photo-multiplier tubes (PMT) Electronic (preamplifiers and amplifiers-digital position logic circuits, pulse-height analyzer circuits) Computer monitor Gamma Camera Components of a standard nuclear medicine imaging system

Chapter-2 The Planar Imaging Camera head The light guide

Chapter-2 The Planar Imaging End of part-1