Fluke 805 Vibration Meter Redefining Vibration Screening 1.

Slides:



Advertisements
Similar presentations
Machine Condition Monitoring
Advertisements

ZonicBook/618EZ-TOMAS Rotating Machinery Monitoring and Analysis
Basic Classification and design overview
Energy Management Practices: Rolling Mills 1. Contents Introduction Energy Intensive Processes & Reduction in Energy Expenditure through Innovative Practices.
Chapter 4 Air-Conditioning Components
Adam Adgar School of Computing and Technology
Fans and Blowers.
Chapter Seven Compressible Fluid.
Purpose Body Making module is designed for bending the laminated foil film in the shape of a tube, for welding the side seam and for cutting bodies with.
Vibration Monitoring and Machine Protection Systems 1010 E. Main St., League City, TX Phone: Fax: /
Pumps CM4120 D. Caspary February, 2004.
In this presentation you will:
Air Conditioning Compressors.
Brought to you by: Demetri Preonas Greg Unverferth
Propulsion Train & Shaft Line Components
Section 4: Electric Motors
Accelerometer’s for Wind Turbines Alternative Energy Wind turbines are a growing source of alternative clean energy sources. As individual machines, or.
Vibration Sensors for Cooling Towers Challenges Cooling towers offer the vibration analyst many challenges in sensor selection, mounting and environmental.
COMMERCIAL REFRIGERATION
Section 5: Commercial Refrigeration
HVACR 317 – Refrigeration Core
Basics of Pump Vigyan Ashram, Pabal.
Application Types Variable Torque Constant Torque.
Advanced Pump Fundamentals Agenda
QUINCY ROTARY SCREW AIR COMPRESSOR QGL 15-37kW
WEATS O&M Issues Sandy Butterfield CEO Boulder Wind Power WEATS
Actuators.
Hydraulic Drives and Actuators. Description A hydraulic drive consists of three major parts: The generator (such as a hydraulic pump) driven by an electric.
Presentation On Vibration Analysis
Reciprocating Compressor
Air Compressors.
Condition Monitoring Adam Adgar School of Computing and Technology.
Vibration Monitoring & Machine Protection Systems Copyright 1999, Frank Howard, STI Vibration Monitoring, Inc. League City, Texas USA Reciprocating.
CHAPTER 4 CPB 20004: Plant Utility n Maintenance
1 PredictiveOnLine PREDICTIVE SYSTEMS ENGINEERING Vintec Knowledge Ltd.
MCS’S MAGNUM DIAGNOSTICS PACKAGE Visit us at
AIR BEARING SYSTEM.
Prepared by: Marimuthu Gurusamy Combined vibration analysis (velocity and acceleration envelope) for Prediction of rotating equipment (with rolling element.
Vibration in SAG Mill Foundation of Stream 3 - Chronological Sequence & An Update.
Pumps Unit 10. Learning Objectives TLW be able to describe the following about pumps used in the process industry: –Types –Uses –Operation –Monitoring.
Positive Displacement Pumps.
MECH1300 Pneumatic Power Supply Topics Compressor Types Compressor Sizing Vacuum Pumps Chapter 11.
Conditioned-Based Maintenance
Parul Institute of Engineering & Technology Subject Code : Name Of Subject : Fluid Power Engineering Name of Unit : Pumps Topic : Reciprocating.
Vibration & Temperature Sensor. Contents ■ Why monitor vibration? ■ Health degradation curve ■ Predictive maintenance monitoring ■ Monitor a wide range.
Parul Institute of Technology
Refrigerant compressors Akshay Kr Mishra Sharda University 4 TH YR. MECHANICAL.
Kaeser Direct Drive ESD Rotary Screw Compressor
Gas Movers and Compressors Fans Centrifugal blowers and compressors Rotary blowers and compressors Reciprocating compressors Ejectors Discharge pressure.
L.J.INSTITUTE OF ENGINEERING AND TECHNOLOGY compressors Shah Aadishkumar Aileshbhai (enrollment no ) (div A roll no. 55) Guided by Mr.hemangsir.
Fluke 376 True-rms AC/DC Clamp Meter with iFlex™ A Basic Guide to Illustrate Measurement Procedure Using the Product.
Digital Multimeter – Basic Guide
R ECIPROCATING P UMPS Prof. Shrikant M. Harle Dept of Civil Engg PRMCEAM, Badnera.
TRANSPORTATION AND METERING OF FLUIDS FFO
Prepared By Rohit G. Sorte M.Tech
RECIPROCATING COMPRESSORS
TROUBLESHOOTING ELECTRIC MOTORS
Fluke Ti 25 – Thermal Imager A brief overview of the product, its specifications and user instructions.
Miscellaneous Hydraulic Machine
Who is KME? Established in 1989, KME has been dedicated to providing the best service to our clients. We believe that quality and best value are crucial.
Linear actuator Cylinders Single acting Double acting
Level 2 Vibration Analysis
Optimum Pump Performance for Process Applications
Hydraulics Motor.
Process Equipment Design and Heuristics – Gas Compressors
Xerox Bearing Tester Systems Level Design Review
Vibration Monitoring System M14
A course in Turbomachinery Lecturer: Dr.Naseer Al-Janabi
Classification of air compressors. What are compressors? Compressors are mechanical devices that compresses gases. It is widely used in industries and.
PUMPS AND DRIVERS NCCER
Presentation transcript:

Fluke 805 Vibration Meter Redefining Vibration Screening 1

2 Types of Vibration Testing Simple vibration screening: Overall vibration/bearing measurements Use vibration screening tools to make quick “go” or “no go” decisions by checking the value against a pre-set alarm level, comparing it to ISO Standards (ISO 10816) and trending the results over time.

3 What does it measure? 805 Vibration Meter is Fluke’s multifunction vibration checker which Provides quantifiable results of bearing condition, overall vibration, temperature Assesses the severity on a severity scale Provides ability to upload the data to PC for later trending -

4 The Problem The Solution

5

6

7

8 Fluke 805 redefines vibration screening Performs in low frequency range to measure overall vibration and in high frequency range to identify bearing faults. Assesses severity on a four-level scale for both overall vibration and bearings. Uses the new and innovative Crest Factor Plus algorithm.

9 What is Crest Factor +? A proprietary, weighted calculation involving several waveform parameters, such as the Crest Factor, the Peak value, and the RMS value algorithm used to identify bearing faults.

10 Fluke 805 checks against 37 machine categories Chiller (refrigeration) Reciprocating (Open motor and compressor separate) Reciprocating (Hermetic motor and compressor) Centrifugal (Hermetic or Open Motor Fans Belt-driven Fans 1800 to 3600 RPM Belt-driven fans 600 to 1799 RPM General direct drive fans (direct coupled) Vacuum blowers (belt or direct drive) Large forced draft fans (fluid film brgs.) Large induced draft fans (fluid film brgs.) Shaft-mounted integral fan (extended motor shaft) Axial flow fans (belt or direct drive) Cooling tower drives Long, hollow drive shaft (motor) Belt drive (motor and fan - all arrangements) Direct drive (motor and fan - all arrangements Centrifugal Pumps Note: height is measured from grade to top motor bearing Vertical pumps (12’ to 20’ height) Vertical pumps (8’ to 12’ height) Vertical pumps (5’ to 8’ height) Vertical pumps (0’ to 5’ height) Horizontal centrifugal end suction pumps – direct coupled Horizontal centrifugal double suction pumps – direct coupled Boiler feed pumps (turbine or motor driven) Positive Displacement Pumps Positive displacement horizontal piston pumps (under load) Positive displacement horizontal gear pumps (under load) Air compressors Reciprocating Rotary screw Centrifugal with or without external gearbox Centrifugal – internal gear (axial meas.) Centrifugal – internal gear (radial meas.) Blowers Lobe-type rotary blowers (belt or direct drive) Multi-stage centrifugal blowers (direct drive) Generic gearboxes (rolling element bearings) Single stage gearbox Machine tools Motor Gearbox input Gearbox output Spindles – roughing operations Spindles – machine finishing Spindles – critical finishing

11 How to use the 805 Supports an optional external sensor Any standard ICP type, (100 mV/g) single channel accelerometer If external sensor is connected, the users will be able to measure only overall vibration (no CF+ and temperature measurement)

12 How to use the 805 The meter has an audio connector for headphones – useful for detection of unusual machine sounds. Press and hold the measure button to listen with sensor tip pressed against bearing.

13 Benefits of Trending with Vibration Meter Export measurements to Excel template on PC to trend overall vibration, CF+, and IR temperature. Looking at the number alone for the overall vibration or bearing condition might not be of much benefit What is normal or what indicates a problem? 805 users can use the severity assessment and trending functionality to overcome this obstacle.

14 Benefits of Trending with Vibration Meter After operator rounds, trend with preconfigured Excel plot graphs and compare to ISO Standards ( , -3 and -7). If there is an abnormality, it can be identified by using the trend charts. The user can now see a clear picture of the changing bearing condition and deteriorating health of the machine

Compare 805 and 810 Front line mechanical maintenance teams need: A quick screening tool to fit into existing rounds Reliable / repeatable measurements of rotating equipment to make imperative go/no-go maintenance decisions Ability to trend readings over time and notify a consultant or reliability engineer when something abnormal arises Quick understanding of overall machine and bearing condition, to decide on repairs and repair equipment Maintenance troubleshooters need: Quick answers on specific machine condition fault/severity Extensive setup, trending, analysis, and onsite expert not needed to get machine condition answers Ability to trend machine fault severity over time to help decide when to generate a work order for repair Majority of rotating machines are basic enough for the vibration tester to be the perfect choice Vibration Meter Vibration Tester

16 Forget the Pen… Think METER Fluke 805 is the most reliable and the user intuitive vibration screening device for frontline troubleshooting teams. FOOLPROOF instead of false alarms REPEATABLE instead of random EASY instead of confusing

Company Name : Fluke Corporation - India Website: Address: Division of DHR Holding India Pvt. Ltd. 10th Floor, Sigma Hiranandani Business Park, Powai Mumbai, Maharashtra Contact Number: